Andrea Heger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andrea Heger has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
A. Neisser‐Svae
Octapharma Pharmazeutika Produktionsges.m.b.H, Medical Affairs, Vienna, Austria
3 shared publicationsJ. Römisch
Octapharma Pharmazeutika Produktiosges.m.b.H, Research & Development, Vienna, Austria
3 shared publicationsJürgen Römisch
Octapharma Pharmazeutika Produktionsges.m.b.H, Vienna, Austria
2 shared publicationsMichelle Gareis
Octapharma Pharmazeutika Produktionsges.m.b.H Vienna Austria
2 shared publicationsT.‐E. Svae
Octapharma AG, Lachen, Switzerland
2 shared publications- Andy Bailey
ViruSure GmbH, Tech Gate Wissenschafts und Technologie Park, Vienna, Austria
1 shared publication
Latest Publications
- Open Access
- 25 November 2024
- Published by Wiley in Transfusion Medicine
- Vol. 35 (1) , 97-102
Validation of current commercially‐available devices to thaw pooled, solvent/detergent‐treated human plasma
Background: Proper thawing procedures are required to preserve the quality of human fresh frozen plasma (FFP). octaplasLG (Octapharma AG, Switzerland) is a frozen solution of solvent/detergent (S/D)‐treated human plasma, produced to improve pathogen safety. This study aimed to validate the S/D plasma thawing process using the latest‐generation of commercially‐available thawing devices and to determine S/D plasma quality after thawing.Study Design and Methods: Thawing of S/D plasma units was investigated using a microwave oven (Transfusio‐therm 3000) and dry tempering systems (SAHARA 4 and Plasmatherm V). Times to defrost plasma and reach 30°C product temperature, using the 37°C thawing programmes, were defined for all devices. Thawed S/D plasma units were tested against product release parameters, as well as for hemostatic capacity tested indirectly via global coagulation parameters, coagulation factors, protease inhibitors and markers of activated coagulation.Results: The fastest thawing was observed using the microwave oven; S/D plasma units were defrosted after 2–3 min. All S/D plasma units thawed by the different devices using optimised thawing conditions were clear and free of solid and gelatinous particles, indicating no local overheating or protein denaturation. Coagulation factor and inhibitor activities and hemostatic capacity of S/D plasma were comparable when thawed by the three different devices. With each device, all product parameters were within product release specification levels after thawing.Conclusions: S/D plasma can be thawed using the Transfusio‐therm 3000, SAHARA 4 or Plasmatherm V thawing devices using the optimised settings defined for this plasma product, with no negative influence on plasma quality.
- 25 November 2024
- Published by Wiley in Transfusion Medicine
- Vol. 35 (1) , 97-102
Open AccessValidation of current commercially‐available devices to thaw pooled, solvent/detergent‐treated human plasma
Background: Proper thawing procedures are required to preserve the quality of human fresh frozen plasma (FFP). octaplasLG (Octapharma AG, Switzerland) is a frozen solution of solvent/detergent (S/D)‐treated human plasma, produced to improve pathogen safety. This study aimed to validate the S/D plasma thawing process using the latest‐generation of commercially‐available thawing devices and to determine S/D plasma quality after thawing.Study Design and Methods: Thawing of S/D plasma units was investigated using a microwave oven (Transfusio‐therm 3000) and dry tempering systems (SAHARA 4 and Plasmatherm V). Times to defrost plasma and reach 30°C product temperature, using the 37°C thawing programmes, were defined for all devices. Thawed S/D plasma units were tested against product release parameters, as well as for hemostatic capacity tested indirectly via global coagulation parameters, coagulation factors, protease inhibitors and markers of activated coagulation.Results: The fastest thawing was observed using the microwave oven; S/D plasma units were defrosted after 2–3 min. All S/D plasma units thawed by the different devices using optimised thawing conditions were clear and free of solid and gelatinous particles, indicating no local overheating or protein denaturation. Coagulation factor and inhibitor activities and hemostatic capacity of S/D plasma were comparable when thawed by the three different devices. With each device, all product parameters were within product release specification levels after thawing.Conclusions: S/D plasma can be thawed using the Transfusio‐therm 3000, SAHARA 4 or Plasmatherm V thawing devices using the optimised settings defined for this plasma product, with no negative influence on plasma quality.
- Open Access
- 21 April 2024
- Published by Wiley in Transfusion
- Vol. 64 (6) , 1132-1153
Thirty years of experience with solvent/detergent‐treated plasma for transfusion medicine
- 21 April 2024
- Published by Wiley in Transfusion
- Vol. 64 (6) , 1132-1153
Open AccessThirty years of experience with solvent/detergent‐treated plasma for transfusion medicine
- Open Access
- 1 October 2022
- Published by Wiley in Transfusion
- Vol. 62 (12) , 2621-2630
Frozen and freeze‐dried solvent/detergent treated plasma: Two different pharmaceutical formulations with comparable quality
Background: OctaplasLG is a frozen solvent/detergent‐treated plasma product used for treating complex coagulation factor deficiencies or as substitution therapy in emergency situations where specific factor concentrates are not available. A new freeze‐dried (also known as lyophilized) form of OctaplasLG, referred as OctaplasLG Lyo (Octapharma AG, Switzerland) offers rapid reconstitution and more flexible storage conditions, improving logistics and utilization. This study compared the biochemical quality of OctaplasLG Lyo with OctaplasLG and single‐donor fresh frozen plasma units.Study Design and Methods: Three batches of OctaplasLG Lyo, manufactured for production process qualification, and 12 batches of OctaplasLG were provided by Octapharma AB (Sweden). Twelve units of fresh frozen plasma were collected by the local FDA‐licensed blood provider. All plasma samples were assessed for global coagulation parameters, coagulation factors and protease inhibitors, activation markers of coagulation and fibrinolysis, and important plasma proteins. Quality control assays were conducted in accordance with European Pharmacopeia requirements.Results: Frozen and freeze‐dried OctaplasLG demonstrated comparable quality profiles upon thawing or reconstitution. All coagulation factor and protease inhibitor activity parameters were in line with levels mandated by the European Pharmacopeia. Fresh frozen plasma units showed comparable coagulation factor activities, with higher protein S and plasmin inhibitor levels than the OctaplasLG products. Fresh frozen plasma parameters showed high lot‐to‐lot variations.Discussion: The two pharmaceutical forms of OctaplasLG (frozen and freeze‐dried) have comparable biochemical quality. Key features of OctaplasLG Lyo are rapid reconstitution time and storage flexibility, which may improve logistics and utilization, and have particular advantages in emergency situations and pre‐hospital settings.
- 1 October 2022
- Published by Wiley in Transfusion
- Vol. 62 (12) , 2621-2630
Open AccessFrozen and freeze‐dried solvent/detergent treated plasma: Two different pharmaceutical formulations with comparable quality
Background: OctaplasLG is a frozen solvent/detergent‐treated plasma product used for treating complex coagulation factor deficiencies or as substitution therapy in emergency situations where specific factor concentrates are not available. A new freeze‐dried (also known as lyophilized) form of OctaplasLG, referred as OctaplasLG Lyo (Octapharma AG, Switzerland) offers rapid reconstitution and more flexible storage conditions, improving logistics and utilization. This study compared the biochemical quality of OctaplasLG Lyo with OctaplasLG and single‐donor fresh frozen plasma units.Study Design and Methods: Three batches of OctaplasLG Lyo, manufactured for production process qualification, and 12 batches of OctaplasLG were provided by Octapharma AB (Sweden). Twelve units of fresh frozen plasma were collected by the local FDA‐licensed blood provider. All plasma samples were assessed for global coagulation parameters, coagulation factors and protease inhibitors, activation markers of coagulation and fibrinolysis, and important plasma proteins. Quality control assays were conducted in accordance with European Pharmacopeia requirements.Results: Frozen and freeze‐dried OctaplasLG demonstrated comparable quality profiles upon thawing or reconstitution. All coagulation factor and protease inhibitor activity parameters were in line with levels mandated by the European Pharmacopeia. Fresh frozen plasma units showed comparable coagulation factor activities, with higher protein S and plasmin inhibitor levels than the OctaplasLG products. Fresh frozen plasma parameters showed high lot‐to‐lot variations.Discussion: The two pharmaceutical forms of OctaplasLG (frozen and freeze‐dried) have comparable biochemical quality. Key features of OctaplasLG Lyo are rapid reconstitution time and storage flexibility, which may improve logistics and utilization, and have particular advantages in emergency situations and pre‐hospital settings.
- 23 April 2018
- Published by Wiley in Vox Sanguinis
- Vol. 113 (5) , 485-488
Thrombin generation potential and clot‐forming capacity of thawed fresh‐frozen plasma, plasma frozen within 24 h and solvent/detergent‐treated plasma (octaplasLG®), during 5‐day storage at 1–6°C
To enable rapid availability of plasma in emergency situations, the shelf‐life of thawed fresh‐frozen plasma (FFP) has been extended from 24 h to 5 days. The aim of this study was to evaluate the thrombin generation (TG) potential and clot‐forming ability during 5 days of refrigerated storage of thawed FFP, plasma frozen within 24 h and solvent/detergent‐treated plasma octaplasLG®. During storage for 5 days, TG capacity decreased significantly over time, and rotational thromboelastometry showed significantly prolonged clotting times. However, the stability studies confirmed comparable in vitro haemostatic potentials of all three thawed plasma products at day 5.
- 23 April 2018
- Published by Wiley in Vox Sanguinis
- Vol. 113 (5) , 485-488
Thrombin generation potential and clot‐forming capacity of thawed fresh‐frozen plasma, plasma frozen within 24 h and solvent/detergent‐treated plasma (octaplasLG®), during 5‐day storage at 1–6°C
To enable rapid availability of plasma in emergency situations, the shelf‐life of thawed fresh‐frozen plasma (FFP) has been extended from 24 h to 5 days. The aim of this study was to evaluate the thrombin generation (TG) potential and clot‐forming ability during 5 days of refrigerated storage of thawed FFP, plasma frozen within 24 h and solvent/detergent‐treated plasma octaplasLG®. During storage for 5 days, TG capacity decreased significantly over time, and rotational thromboelastometry showed significantly prolonged clotting times. However, the stability studies confirmed comparable in vitro haemostatic potentials of all three thawed plasma products at day 5.
- Open Access
- 14 March 2017
- Published by S. Karger AG in Transfusion Medicine and Hemotherapy
- Vol. 44 (2) , 94-98
Thawing of Pooled, Solvent/Detergent-Treated Plasma octaplasLG®: Validation Studies Using Different Thawing Devices
Background: The aim of this study was to perform validation of the thawing process for solvent/detergent-treated plasma octaplasLG® using different thawing devices. Optimized settings for temperature and thawing time should be defined based on the results of both temperature measurements and extensive biochemical characterization studies. Methods: octaplasLG units were thawed using water bath systems (i.e. MB-13A, QuickThaw® DH4), dry tempering systems (i.e. plasmatherm, SAHARA-III), and microwave oven (i.e. transfusio-therm® 2000). Optimized thawing conditions were defined. Subsequently, using the selected thawing conditions, octaplasLG units were thawed and tested on product release parameters. Results: The fastest thawing was observed for the microwave oven. All octaplasLG units thawed by different devices and optimized thawing conditions were clear and free of solid and gelatinous particles, indicating no protein denaturation or overheating. In addition, no significant differences were found in the coagulation and inhibition activity and hemostatic potency of octaplasLG when thawed by the different devices tested. All parameters after thawing were within the product release specification levels. Conclusion: Our study demonstrated that octaplasLG can be thawed using all above listed devices without any negative influence on the plasma quality, presupposed that optimized settings defined for this plasma product are used.
- 14 March 2017
- Published by S. Karger AG in Transfusion Medicine and Hemotherapy
- Vol. 44 (2) , 94-98
Open AccessThawing of Pooled, Solvent/Detergent-Treated Plasma octaplasLG®: Validation Studies Using Different Thawing Devices
Background: The aim of this study was to perform validation of the thawing process for solvent/detergent-treated plasma octaplasLG® using different thawing devices. Optimized settings for temperature and thawing time should be defined based on the results of both temperature measurements and extensive biochemical characterization studies. Methods: octaplasLG units were thawed using water bath systems (i.e. MB-13A, QuickThaw® DH4), dry tempering systems (i.e. plasmatherm, SAHARA-III), and microwave oven (i.e. transfusio-therm® 2000). Optimized thawing conditions were defined. Subsequently, using the selected thawing conditions, octaplasLG units were thawed and tested on product release parameters. Results: The fastest thawing was observed for the microwave oven. All octaplasLG units thawed by different devices and optimized thawing conditions were clear and free of solid and gelatinous particles, indicating no protein denaturation or overheating. In addition, no significant differences were found in the coagulation and inhibition activity and hemostatic potency of octaplasLG when thawed by the different devices tested. All parameters after thawing were within the product release specification levels. Conclusion: Our study demonstrated that octaplasLG can be thawed using all above listed devices without any negative influence on the plasma quality, presupposed that optimized settings defined for this plasma product are used.
- 27 May 2016
- Published by Wiley in Vox Sanguinis
- Vol. 111 (3) , 266-273
Comparative biochemical studies of fresh frozen plasma and pooled solvent/detergent‐treated plasma (octaplasLG®) with focus on protein S and its impact in different thrombin generation assay set‐ups
Background and Objectives: The solvent/detergent treatment enables effective and robust inactivation of all lipid‐enveloped viruses, but also inactivates partly sensitive plasma proteins such as protein S. The aim of this study was to investigate the thrombin generation capacity of octaplasLG®, in particular focusing on the function of protein S in thrombin generation assay and the impact of assay settings.Materials and Methods: Sixteen octaplasLG® batches and 32 units of single donor fresh frozen plasma (FFP) were investigated. For protein S, both functional activity and free antigen levels were measured. Thrombin generation assay was performed using two fluorogenic tests with different triggers. Finally, rotational thromboelastometry was performed.Results: Mean protein S levels were lower in octaplasLG®, but a wider range of values was found for FFP. Clotting parameters and thrombin generation capacities overlapped between the two plasma groups as demonstrated using both thrombin generation assays and different triggers. Spiking studies with protein S‐depleted plasma, human purified protein S or antibodies against protein S confirmed a correlation between protein S and thrombin generation capacity under specific assay conditions, especially in an assay with low tissue factor concentration.Conclusion: Correlation between protein S and thrombin generation capacity was demonstrated in the TGA. Due to higher variability in protein S content in the FFP group, overlapping haemostatic potentials of the two plasma groups were found.
- 27 May 2016
- Published by Wiley in Vox Sanguinis
- Vol. 111 (3) , 266-273
Comparative biochemical studies of fresh frozen plasma and pooled solvent/detergent‐treated plasma (octaplasLG®) with focus on protein S and its impact in different thrombin generation assay set‐ups
Background and Objectives: The solvent/detergent treatment enables effective and robust inactivation of all lipid‐enveloped viruses, but also inactivates partly sensitive plasma proteins such as protein S. The aim of this study was to investigate the thrombin generation capacity of octaplasLG®, in particular focusing on the function of protein S in thrombin generation assay and the impact of assay settings.Materials and Methods: Sixteen octaplasLG® batches and 32 units of single donor fresh frozen plasma (FFP) were investigated. For protein S, both functional activity and free antigen levels were measured. Thrombin generation assay was performed using two fluorogenic tests with different triggers. Finally, rotational thromboelastometry was performed.Results: Mean protein S levels were lower in octaplasLG®, but a wider range of values was found for FFP. Clotting parameters and thrombin generation capacities overlapped between the two plasma groups as demonstrated using both thrombin generation assays and different triggers. Spiking studies with protein S‐depleted plasma, human purified protein S or antibodies against protein S confirmed a correlation between protein S and thrombin generation capacity under specific assay conditions, especially in an assay with low tissue factor concentration.Conclusion: Correlation between protein S and thrombin generation capacity was demonstrated in the TGA. Due to higher variability in protein S content in the FFP group, overlapping haemostatic potentials of the two plasma groups were found.
- 1 February 2015
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 52 (1) , 128-135
Universal pooled plasma (Uniplas®) does not induce complement-mediated hemolysis of human red blood cells in vitro
- 1 February 2015
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 52 (1) , 128-135
Universal pooled plasma (Uniplas®) does not induce complement-mediated hemolysis of human red blood cells in vitro
- 10 November 2011
- Published by Wiley in Vox Sanguinis
- Vol. 102 (4) , 294-301
Removal of prion infectivity by affinity ligand chromatography during OctaplasLG® manufacturing – results from animal bioassay studies
Background OctaplasLG® is a 2nd‐generation virus inactivated pooled plasma for infusion. Prions are removed by the principle of chromatography, utilizing an affinity ligand gel (LG) developed for binding of prion proteins and their infectivity. The goal of this study was to verify, using the gold standard animal bioassay system, whether or not prion infectivity can be removed by the LG affinity step under conditions used in the routine manufacturing process. Materials and methods Aliquots of pooled plasma were spiked with a microsomal/cytosolic (MIC) fraction of brain‐derived hamster‐adapted scrapie 263K and subjected to the OctaplasLG® manufacturing process. Validated Western blot tests and animal bioassays studies were performed to determine the logarithmic reduction factors (RF) and the prion infectivity binding capacity. Results Bioassay studies demonstrated different logarithmic RFs (i.e. 1·73 and 0·76 log10) at two different plasma‐to‐resin ratios, the latter one representing the actual manufacturing ratio of 100:1, which can be explained by the differences in the study design. However, both bioassay studies showed a reproducible and high prion infectivity binding capacity of ≥5·64 log10 ID50/ml gel. Conclusion Bioassay studies confirmed the capacity of the LG to bind brain‐derived MIC prion proteins spiked into plasma. Even through infectivity was still detected following passage over the LG, this can be attributed to the high loads used in the study design, and the binding capacity of the LG still ensures a significant safety margin – binding the prion agents at the levels of prion infectivity that might be present in plasma and beyond.
- 10 November 2011
- Published by Wiley in Vox Sanguinis
- Vol. 102 (4) , 294-301
Removal of prion infectivity by affinity ligand chromatography during OctaplasLG® manufacturing – results from animal bioassay studies
Background OctaplasLG® is a 2nd‐generation virus inactivated pooled plasma for infusion. Prions are removed by the principle of chromatography, utilizing an affinity ligand gel (LG) developed for binding of prion proteins and their infectivity. The goal of this study was to verify, using the gold standard animal bioassay system, whether or not prion infectivity can be removed by the LG affinity step under conditions used in the routine manufacturing process. Materials and methods Aliquots of pooled plasma were spiked with a microsomal/cytosolic (MIC) fraction of brain‐derived hamster‐adapted scrapie 263K and subjected to the OctaplasLG® manufacturing process. Validated Western blot tests and animal bioassays studies were performed to determine the logarithmic reduction factors (RF) and the prion infectivity binding capacity. Results Bioassay studies demonstrated different logarithmic RFs (i.e. 1·73 and 0·76 log10) at two different plasma‐to‐resin ratios, the latter one representing the actual manufacturing ratio of 100:1, which can be explained by the differences in the study design. However, both bioassay studies showed a reproducible and high prion infectivity binding capacity of ≥5·64 log10 ID50/ml gel. Conclusion Bioassay studies confirmed the capacity of the LG to bind brain‐derived MIC prion proteins spiked into plasma. Even through infectivity was still detected following passage over the LG, this can be attributed to the high loads used in the study design, and the binding capacity of the LG still ensures a significant safety margin – binding the prion agents at the levels of prion infectivity that might be present in plasma and beyond.
- 24 September 2009
- Published by Wiley in Vox Sanguinis
- Vol. 97 (3) , 219-225
Biochemical quality of the pharmaceutically licensed plasma OctaplasLG® after implementation of a novel prion protein (PrPSc) removal technology and reduction of the solvent/detergent (S/D) process time
Background and Objectives A new chromatographic step for the selective binding of pathological prion proteins (PrPSc) to an affinity ligand, developed and optimized for PrPSc capture and attached to synthetic resin particles (PRDT, USA; ProMetic BioSciences Ltd, Isle of Man, UK) was implemented into the manufacturing process of the solvent/detergent (S/D) treated biopharmaceutical quality plasma Octaplas®.Materials and Methods Pilot batches of Octaplas® with the implemented chromatographic step [labelled as OctaplasLG® (ligand gel)] were manufactured by Octapharma PPGmbH, Vienna, Austria. The biochemical quality was compared directly after manufacturing as well as after 18 months storage. All samples were tested on global coagulation parameters, fibrinogen levels, activities of coagulation factors and protease inhibitors, ADAMTS13 levels, as well as markers of activated coagulation and fibrinolysis. In addition, von Willebrand factor multimeric analysis was performed.Results The incorporation of this novel chromatography into the large‐scale routine manufacturing process was shown to be technically feasible and the performance of the column was assessed to be excellent. The biochemical studies showed that Octaplas® and OctaplasLG® produced without and with the new column, respectively, demonstrate an identical biochemical quality. OctaplasLG® remained stable over a period of 18 months stored frozen. A parallel reduction of the S/D virus inactivation step from 4–4·5 to 1–1·5 h led to significantly higher activities of plasmin inhibitor.Conclusion The studies confirmed that the affinity ligand chromatography under the developed conditions can be introduced into the Octaplas® manufacturing process, as a mean to reduce potentially present PrPSc, without hampering the proven quality of this product.
- 24 September 2009
- Published by Wiley in Vox Sanguinis
- Vol. 97 (3) , 219-225
Biochemical quality of the pharmaceutically licensed plasma OctaplasLG® after implementation of a novel prion protein (PrPSc) removal technology and reduction of the solvent/detergent (S/D) process time
Background and Objectives A new chromatographic step for the selective binding of pathological prion proteins (PrPSc) to an affinity ligand, developed and optimized for PrPSc capture and attached to synthetic resin particles (PRDT, USA; ProMetic BioSciences Ltd, Isle of Man, UK) was implemented into the manufacturing process of the solvent/detergent (S/D) treated biopharmaceutical quality plasma Octaplas®.Materials and Methods Pilot batches of Octaplas® with the implemented chromatographic step [labelled as OctaplasLG® (ligand gel)] were manufactured by Octapharma PPGmbH, Vienna, Austria. The biochemical quality was compared directly after manufacturing as well as after 18 months storage. All samples were tested on global coagulation parameters, fibrinogen levels, activities of coagulation factors and protease inhibitors, ADAMTS13 levels, as well as markers of activated coagulation and fibrinolysis. In addition, von Willebrand factor multimeric analysis was performed.Results The incorporation of this novel chromatography into the large‐scale routine manufacturing process was shown to be technically feasible and the performance of the column was assessed to be excellent. The biochemical studies showed that Octaplas® and OctaplasLG® produced without and with the new column, respectively, demonstrate an identical biochemical quality. OctaplasLG® remained stable over a period of 18 months stored frozen. A parallel reduction of the S/D virus inactivation step from 4–4·5 to 1–1·5 h led to significantly higher activities of plasmin inhibitor.Conclusion The studies confirmed that the affinity ligand chromatography under the developed conditions can be introduced into the Octaplas® manufacturing process, as a mean to reduce potentially present PrPSc, without hampering the proven quality of this product.