CKC Kappas

C Kappas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


C Kappas has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Monte Carlo approach to electron contamination sources in the Saturne-25 and -41

    by G Malataras, C Kappas, D M J Lovelock

    The various components of the accelerator treatment head act as sources of contaminating electrons. The presence of contamination electrons increases the surface dose, which deteriorates the skin-sparing effect. The present study examines the sources of this `contamination', the influence on the surface dose and the shape of the build-up curve. The Monte Carlo simulation of two linear accelerators, Saturne-25 and -41, allowed us to study the influence of electron contamination in various therapeutic energies and in different geometries. The Saturne-25 and -41 cover a wide range of therapeutic energies with nominal energies 12/23 MV and 6/15 MV, respectively. The analysis of the results shows that at a source-to-surface distance of 100 cm and a wide opening of the collimators, the main sources of contaminating electrons are the flattening filter and the air below it. The contribution of the secondary contamination electrons on the surface dose is 16% for 6 MV and 12 MV, 6% for 15 MV and 17% for 23 MV. The energy spectra of electrons coming from the flattening filter and the air below it are completely different. The air produces electrons of low energies. The mean energies of these spectra vary from 1 MeV to 2 MeV depending on the nominal energy of the photon beam. The secondary electrons generated by the flattening filter produce a wide energy spectrum with mean energies of the same order of the bremsstrahlung spectrum. The flattening filter absorbs the secondary electrons generated in the target, the primary collimator and the air inside the head.


  • A multiobjective gradient-based dose optimization algorithm for external beam conformal radiotherapy

    by C Cotrutz, M Lahanas, C Kappas, D Baltas

    A multiobjective gradient-based algorithm has been developed for the purpose of dose distribution optimization in external beam conformal radiotherapy. This algorithm is based on the concept of gathering the values of all objectives into a single value. The weighting factors of the composite objective values are varied in different steps, allowing the reconstruction of the trade-off surfaces (three or more objectives) or curves (two objectives) which define the boundary between the feasible and non-feasible domain regions. The analysis of these curves allows the decision-maker to select the solution that best fits the clinical goals. In contrast to all the other algorithms, our method provides not a single solution but a sample of solutions representing all possible clinical importance factors (weights) for the objectives used. The application of this algorithm to two test cases shows that a correct selection for the importance factors to multiply the individual objectives in the global objective value is not trivial and that the location and shape of the boundary region between the feasible and non-feasible solution regions are case dependent. Provided that the individual objective functions are analytically differentiable and that the number of objectives is the range of two to three, the computation times are acceptable for clinical use. Furthermore, the optimization for a unique combination of importance factors within the aggregate objective function is performed in less than 1 min.


  • Intensity modulated arc therapy (IMAT) with centrally blocked rotational fields

    by C Cotrutz, C Kappas, S Webb

    A new technique for intensity-modulated beam (IMB) delivery that combines the features of intensity modulated arc therapy (IMAT) with the use of 'classical blocks' is proposed. The role of the blocks is to realize the high-gradient modulation of the intensity profile corresponding to the region to be protected within the body contour, while the MLC leaves or the secondary collimator defines the rest of the field and delivers intensity-modulated multiple rotational segments. The centrally blocked radiation fields are applied sequentially, in several rotations. Each rotation of the gantry is responsible for delivering one segment of the optimal intensity profile. The new IMAT technique is applied for a treatment geometry represented by an annular target volume centrally located within a circular body contour. The annulus encompasses a circular critical structure, which is to be protected. The beam opening and corresponding weight of each segment are determined in two ways. The first method applies a linear optimization algorithm to precalculated centrally blocked radial dose profiles. These radial profiles are calculated for a set of beam openings, ranging from the largest field that covers the whole planning target volume (PTV) to the smallest, which is 1 cm larger than the width of the central block. The optimization is subjected to dose homogeneity constraints imposed on a linear combination of these profiles and finally delivers the dimensions and weights of the rotational beams to be used in combination. The second method decomposes into several subfields the fluence profile of a rotational beam known to deliver a constant dose level to PTV. This fluence profile is determined by using the analytical method proposed by Brahme for the case of the annular PTV and the concentric organ at risk (OAR). The proper segmentation of this intensity profile provides the field sizes and corresponding weights of the subfields to be used in combination. Both methods show that for this particular treatment geometry, three to seven segments are sufficient to cover the PTV with the 95% dose level and to keep the dose level to the central critical structure under 30% of the maximum dose. These results were verified by experimentally delivering the calculated segments to radiotherapy verification films sandwiched between two cylindrical pieces of a pressed-wood phantom. The total beam time for a three-field irradiation was 77 s. The predicted and experimental dose profiles along the radius of the phantom agreed to within 5%. Generalization of this technique to real-patient treatment geometry and advantages over other conformal radiotherapy techniques are also discussed.