Brian Hilton Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brian Hilton Brown has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Dilly O. C. Anumba
Division of Clinical Medicine, School of Medicine & Population Health, Faculty of Health, The University of Sheffield, Jessop Wing, Tree Root Walk, Sheffield S10 2SF, UK
3 shared publications - Roderick Smallwood
Department of Computer Science, University of Sheffield, Sheffield, United Kingdom
3 shared publications - Andrew James Narracott
University of Sheffield
2 shared publications John A. Tidy
Department of Gynaecological Oncology, Royal Hallamshire Hospital, Glossop Road, Sheffield S10 2JF
2 shared publicationsM. J. Jackson
University of Sheffield
2 shared publicationsP. Milnes
University of Sheffield, Royal Hallamshire Hospital
2 shared publications
Latest Publications
- 1 September 2021
- Published by Springer Nature in Indian Journal of Gynecologic Oncology
- Vol. 19 (3) , 1-6
Clinical Utility of ZedScan When Used as an Adjunct to Colposcopy
- 1 September 2021
- Published by Springer Nature in Indian Journal of Gynecologic Oncology
- Vol. 19 (3) , 1-6
Clinical Utility of ZedScan When Used as an Adjunct to Colposcopy
- Open Access
- 1 January 2020
- Published by Walter de Gruyter GmbH in Journal of Electrical Bioimpedance
- Vol. 11 (1) , 81-86
Prognostic value of Electrical Impedance Spectroscopy (EIS) when used as an adjunct to Colposcopy – a longitudinal study
Objective: Colposcopy can be used with Electrical Impedance Spectroscopy (EIS) as an adjunct, to assess the presence of High Grade Cervical Intra-epithelial Neoplasia (CIN2+). This analysis of longitudinal data has used the results from women with a negative colposcopy, in order to see if the initial (index) EIS results were able to predict the women who subsequently developed CIN2+. A further objective was to investigate what tissue structural changes might be reflected in the electrical impedance spectra. Methods: 847 patients were referred with low grade cytologly. EIS measurements were made around the transformation zone of the cervix during colposcopy. Every EIS spectrum was matched to a template representing CIN2+ and the result was positive if the match exceeded a probability index threshold. The colposcopic impression was also recorded. All the women who developed biopsy proven CIN2+ within three years of the index colposcopy were identified. Results: The median follow-up was 30.5 months. Where both CI and EIS were initially positive, there was an increased prevalence (8.13%) of CIN2+ developing as opposed to 3.45% in the remaining patients (p=0.0159). In addition, if three or more EIS spectra were positive there was a higher prevalence (9.62% as opposed to 3.56% p=0.0132) of CIN2+ at three years. The index spectra recorded from the women who developed CIN2+ showed EIS changes consistent with increases in the extracellular volume and in cell size inhomogeneity. Conclusion: EIS does offer prognostic information on the risk of CIN2+ developing over the three-year period following the EIS measurements. The changes in EIS spectra are consistent with an increase in cell size diversity as pre-malignancy develops. These changes may be a consequence of increased genetic diversity as neoplasia develops.
- 1 January 2020
- Published by Walter de Gruyter GmbH in Journal of Electrical Bioimpedance
- Vol. 11 (1) , 81-86
Open AccessPrognostic value of Electrical Impedance Spectroscopy (EIS) when used as an adjunct to Colposcopy – a longitudinal study
Objective: Colposcopy can be used with Electrical Impedance Spectroscopy (EIS) as an adjunct, to assess the presence of High Grade Cervical Intra-epithelial Neoplasia (CIN2+). This analysis of longitudinal data has used the results from women with a negative colposcopy, in order to see if the initial (index) EIS results were able to predict the women who subsequently developed CIN2+. A further objective was to investigate what tissue structural changes might be reflected in the electrical impedance spectra. Methods: 847 patients were referred with low grade cytologly. EIS measurements were made around the transformation zone of the cervix during colposcopy. Every EIS spectrum was matched to a template representing CIN2+ and the result was positive if the match exceeded a probability index threshold. The colposcopic impression was also recorded. All the women who developed biopsy proven CIN2+ within three years of the index colposcopy were identified. Results: The median follow-up was 30.5 months. Where both CI and EIS were initially positive, there was an increased prevalence (8.13%) of CIN2+ developing as opposed to 3.45% in the remaining patients (p=0.0159). In addition, if three or more EIS spectra were positive there was a higher prevalence (9.62% as opposed to 3.56% p=0.0132) of CIN2+ at three years. The index spectra recorded from the women who developed CIN2+ showed EIS changes consistent with increases in the extracellular volume and in cell size inhomogeneity. Conclusion: EIS does offer prognostic information on the risk of CIN2+ developing over the three-year period following the EIS measurements. The changes in EIS spectra are consistent with an increase in cell size diversity as pre-malignancy develops. These changes may be a consequence of increased genetic diversity as neoplasia develops.
- 1 September 2019
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 240, 182-186
The diagnostic accuracy of colposcopy – A review of research methodology and impact on the outcomes of quality assurance
- 1 September 2019
- Published by Elsevier in European Journal of Obstetrics & Gynecology and Reproductive Biology
- Vol. 240, 182-186
The diagnostic accuracy of colposcopy – A review of research methodology and impact on the outcomes of quality assurance
- Open Access
- 2 September 2009
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 9 (1) , 40
The role of cervical Electrical Impedance Spectroscopy in the prediction of the course and outcome of induced labour
Background: Previous work by us and others had suggested that cervical electrical impedance spectroscopy (EIS) may be predictive of the outcome of induced labour. We sought to determine which probe configuration of the EIS device is predictive of the outcome of induced labour and compare this to digital assessment by the Bishop score. Methods: In a prospective cohort of 205 women admitted for induction of labour, we used four probes of diameter 3, 6, 9 and 12 mm connected to an impedance meter to measure cervical resistivity (CR) in Ohm.meters at 14 electrical frequencies and compared their values to digital assessment of the cervix by the Bishop score for the prediction of the outcome of induced labour. We tested the association of labour characteristics and outcomes with CR and Bishop score by stepwise multilinear regression analyses, and the accuracy of prediction of categorical clinical outcomes by analysis of the area under the curves (AUC) of derived Receiver Operator Characteristic (ROC) curves. Results: Of the four CR probe dimensions studied, only the 12 mm probe was predictive of any labour indices. In the frequency range 19 - 156 kHz, CR obtained with this probe was higher in women who delivered by caesarean section (CS) than those who delivered vaginally, and in labours lasting > 24 hrs. Cervical resistivity at 78.1 kHz best predicted vaginal delivery [optimal cut-off 24 hrs [optimal cut-off 2.27 Ω.m, AUC 0.65 (95% CI 0.58, 0.72), sensitivity 71%, specificity 59%, LR+ 1.72, LR- 0.50, P < 0.05]. In contrast digital assessment by the Bishop score neither predicted vaginal delivery nor the duration of labour. However, Bishop score predicted time to onset of labour > 12 hours and induction-delivery interval < 24 hrs [optimal cut-off ≤ 4, AUC 0.8 (95% CI 0.75, 0.86), sensitivity 77%, specificity 76%, LR+ 3.3, LR- 0.3, P < 0.05] whilst CR did not. Conclusion: Cervical resistivity appears predictive of labour duration and delivery mode following induced labour. However the low predictive values obtained suggest that its current design proffers no immediate clinical utility.
- 2 September 2009
- Published by Springer Nature in BMC Pregnancy and Childbirth
- Vol. 9 (1) , 40
Open AccessThe role of cervical Electrical Impedance Spectroscopy in the prediction of the course and outcome of induced labour
Background: Previous work by us and others had suggested that cervical electrical impedance spectroscopy (EIS) may be predictive of the outcome of induced labour. We sought to determine which probe configuration of the EIS device is predictive of the outcome of induced labour and compare this to digital assessment by the Bishop score. Methods: In a prospective cohort of 205 women admitted for induction of labour, we used four probes of diameter 3, 6, 9 and 12 mm connected to an impedance meter to measure cervical resistivity (CR) in Ohm.meters at 14 electrical frequencies and compared their values to digital assessment of the cervix by the Bishop score for the prediction of the outcome of induced labour. We tested the association of labour characteristics and outcomes with CR and Bishop score by stepwise multilinear regression analyses, and the accuracy of prediction of categorical clinical outcomes by analysis of the area under the curves (AUC) of derived Receiver Operator Characteristic (ROC) curves. Results: Of the four CR probe dimensions studied, only the 12 mm probe was predictive of any labour indices. In the frequency range 19 - 156 kHz, CR obtained with this probe was higher in women who delivered by caesarean section (CS) than those who delivered vaginally, and in labours lasting > 24 hrs. Cervical resistivity at 78.1 kHz best predicted vaginal delivery [optimal cut-off 24 hrs [optimal cut-off 2.27 Ω.m, AUC 0.65 (95% CI 0.58, 0.72), sensitivity 71%, specificity 59%, LR+ 1.72, LR- 0.50, P < 0.05]. In contrast digital assessment by the Bishop score neither predicted vaginal delivery nor the duration of labour. However, Bishop score predicted time to onset of labour > 12 hours and induction-delivery interval < 24 hrs [optimal cut-off ≤ 4, AUC 0.8 (95% CI 0.75, 0.86), sensitivity 77%, specificity 76%, LR+ 3.3, LR- 0.3, P < 0.05] whilst CR did not. Conclusion: Cervical resistivity appears predictive of labour duration and delivery mode following induced labour. However the low predictive values obtained suggest that its current design proffers no immediate clinical utility.
- Open Access
- 17 June 2009
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 8 (1) , 10
Reproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure
Background: The utility of cervical electrical impedance spectroscopy (EIS) as a diagnostic tool is being investigated in clinical trials. We sought to assess the reliability of two different sizes of tetrapolar probes used in measuring cervical impedance. Methods: Cervical transfer impedance was measured at 14 frequencies between 76 and 625 000 Hz from 11 pregnant subjects at term. Repeated measurements were taken with two probes (3 mm and 12 mm diameter) applied softly (approximately 0.7 Newton of force), and firmly (approximately 2.2 Newton) to the surface of the cervix by two observers. The intra-class correlation coefficient (ICC), coefficient of variation (CV) and repeatability standard deviations (SD) were derived from these measurements and compared. Results: Measurements taken by one observer were highly repeatable for both probes as demonstrated by high ICC and low CV values. Probe performance was improved further by firm application. Firm application of the 3 mm probe resulted in ICC values that ranged from 0.936 to 0.986 (p = 0.0001) and CV values between 1.0 and 3.4%. Firm pressure with the 12 mm probe resulted in ICC values that ranged between 0.914 and 0.988 (p = 0.0001) with CV values between 0.7 and 2.1%. In addition, the repeatability SD was low across all frequencies implying that there was low intra-observer variability. Measurements taken by 2 observers with firm application of the 12 mm probe demonstrated moderate reproducibility between 9.8 and 156 kHz, the frequency range in which previous clinical studies have shown predictive association between high cervical resistivity and vaginal delivery: ICC values ranged between 0.528 and 0.638 (p < 0.05), CV values were between 3.3 and 5.2% and reproducibility SD values were also low. In contrast the 3 mm probe demonstrated poor reproducibility at all study frequencies. Conclusion: Measuring cervical resistivity by a single observer with both the 3 and 12 mm probes is highly repeatable whilst inter-observer reproducibility is poor with the 3 mm probe but moderately good when the 12 mm probe is firmly applied to the cervix in the frequency range 9.8 to 156 kHz, consistent with our observations of probe performance in clinical trials.
- 17 June 2009
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 8 (1) , 10
Open AccessReproducibility and repeatability of measuring the electrical impedance of the pregnant human cervix-the effect of probe size and applied pressure
Background: The utility of cervical electrical impedance spectroscopy (EIS) as a diagnostic tool is being investigated in clinical trials. We sought to assess the reliability of two different sizes of tetrapolar probes used in measuring cervical impedance. Methods: Cervical transfer impedance was measured at 14 frequencies between 76 and 625 000 Hz from 11 pregnant subjects at term. Repeated measurements were taken with two probes (3 mm and 12 mm diameter) applied softly (approximately 0.7 Newton of force), and firmly (approximately 2.2 Newton) to the surface of the cervix by two observers. The intra-class correlation coefficient (ICC), coefficient of variation (CV) and repeatability standard deviations (SD) were derived from these measurements and compared. Results: Measurements taken by one observer were highly repeatable for both probes as demonstrated by high ICC and low CV values. Probe performance was improved further by firm application. Firm application of the 3 mm probe resulted in ICC values that ranged from 0.936 to 0.986 (p = 0.0001) and CV values between 1.0 and 3.4%. Firm pressure with the 12 mm probe resulted in ICC values that ranged between 0.914 and 0.988 (p = 0.0001) with CV values between 0.7 and 2.1%. In addition, the repeatability SD was low across all frequencies implying that there was low intra-observer variability. Measurements taken by 2 observers with firm application of the 12 mm probe demonstrated moderate reproducibility between 9.8 and 156 kHz, the frequency range in which previous clinical studies have shown predictive association between high cervical resistivity and vaginal delivery: ICC values ranged between 0.528 and 0.638 (p < 0.05), CV values were between 3.3 and 5.2% and reproducibility SD values were also low. In contrast the 3 mm probe demonstrated poor reproducibility at all study frequencies. Conclusion: Measuring cervical resistivity by a single observer with both the 3 and 12 mm probes is highly repeatable whilst inter-observer reproducibility is poor with the 3 mm probe but moderately good when the 12 mm probe is firmly applied to the cervix in the frequency range 9.8 to 156 kHz, consistent with our observations of probe performance in clinical trials.
- Open Access
- 24 November 2006
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 5 (1) , 62
Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes
Background: We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. Methods: Cervical impedance was measured in 12 subjects during early pregnancy using 2 different sizes of the probes on each subject. Results: Mean cervical resistivity was significantly higher (5.4 vs. 2.8 Ωm; p < 0.001) with the smaller probe in the frequency rage of 4–819 kHz. There was no difference in the short-term intra-observer variability between the two probes. The cervical impedance measurements derived in vivo followed the pattern predicted by the finite element model. Conclusion: Inter-electrode distance on the probes for measuring cervical impedance influences the tissue resistivity values obtained. Determining the appropriate probe size is necessary when conducting clinical studies of resistivity of the cervix and other human tissues.
- 24 November 2006
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 5 (1) , 62
Open AccessComparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes
Background: We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. Methods: Cervical impedance was measured in 12 subjects during early pregnancy using 2 different sizes of the probes on each subject. Results: Mean cervical resistivity was significantly higher (5.4 vs. 2.8 Ωm; p < 0.001) with the smaller probe in the frequency rage of 4–819 kHz. There was no difference in the short-term intra-observer variability between the two probes. The cervical impedance measurements derived in vivo followed the pattern predicted by the finite element model. Conclusion: Inter-electrode distance on the probes for measuring cervical impedance influences the tissue resistivity values obtained. Determining the appropriate probe size is necessary when conducting clinical studies of resistivity of the cervix and other human tissues.
- 9 November 2006
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 44 (12) , 1085-1091
Impedance spectral measurements made through a membrane infection barrier
Impedance spectra of superficial tissues can be used to detect pre-malignant changes in the cervix but require electrical contact to be made between a probe and the tissue. Using a membrane which is permeable to ions but forms a barrier to agents of infection should enable impedance spectra to be measured without causing an infection risk to the patient. The properties required of such a membrane are considered and measurements on two suitable membranes are presented. It is shown that impedance spectra can be measured through a thin natural cellulose based membrane (Cuprophan) and that these are not significantly different from directly measured spectra. The ability of the membranes to block a virus is tested using expired polio virus vaccine.
- 9 November 2006
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 44 (12) , 1085-1091
Impedance spectral measurements made through a membrane infection barrier
Impedance spectra of superficial tissues can be used to detect pre-malignant changes in the cervix but require electrical contact to be made between a probe and the tissue. Using a membrane which is permeable to ions but forms a barrier to agents of infection should enable impedance spectra to be measured without causing an infection risk to the patient. The properties required of such a membrane are considered and measurements on two suitable membranes are presented. It is shown that impedance spectra can be measured through a thin natural cellulose based membrane (Cuprophan) and that these are not significantly different from directly measured spectra. The ability of the membranes to block a virus is tested using expired polio virus vaccine.
- 1 September 2002
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 40 (5) , 506-511
Neonatal lungs: Maturational changes in lung resistivity spectra
The electrical resistivity of lung tissue can be related to the structure and composition of the tissue and also to the air content. Electrical impedance tomographic measurements have been used on 155 normal children over the first three years of life and 25 pre-term infants, to determine the absolute resistivity of lung tissue as a function of frequency. The results show consistent changes with increasing age in both lung tissue resistivity (5.8Ωm at birth to 20.9Ωm at 3 years of age) and in the changes of resistivity with frequency (Cole parameter ratio R/S=0.41 at birth and 0.84 at 3 years of age). Comparison with a lung model showed that the measurements are consistent with maturational changes in the number and size of alveoli, the extracapillary blood volume and the size of the extracapillary vessels. However, the results show that the process of maturation is not complete at the age of three years.
- 1 September 2002
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 40 (5) , 506-511
Neonatal lungs: Maturational changes in lung resistivity spectra
The electrical resistivity of lung tissue can be related to the structure and composition of the tissue and also to the air content. Electrical impedance tomographic measurements have been used on 155 normal children over the first three years of life and 25 pre-term infants, to determine the absolute resistivity of lung tissue as a function of frequency. The results show consistent changes with increasing age in both lung tissue resistivity (5.8Ωm at birth to 20.9Ωm at 3 years of age) and in the changes of resistivity with frequency (Cole parameter ratio R/S=0.41 at birth and 0.84 at 3 years of age). Comparison with a lung model showed that the measurements are consistent with maturational changes in the number and size of alveoli, the extracapillary blood volume and the size of the extracapillary vessels. However, the results show that the process of maturation is not complete at the age of three years.
- 1 July 2002
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 40 (4) , 388-394
Neonatal lungs--can absolute lung resistivity be determined non-invasively?
- 1 July 2002
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 40 (4) , 388-394
Neonatal lungs--can absolute lung resistivity be determined non-invasively?
- 18 July 2001
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 12 (8) , 991-996
Medical impedance tomography and process impedance tomography: a brief review
- 18 July 2001
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 12 (8) , 991-996
Medical impedance tomography and process impedance tomography: a brief review