Stephen E. Russek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stephen E. Russek has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Michael J. Donahue
National Institute of Standards and Technology (NIST)
2 shared publicationsShehzaad Kaka
National Institute of Standards and Technology (NIST)
2 shared publicationsAlina M. Deac
1 shared publication- Ciaran Fowley
Helmholtz-Zentrum Dresden—Rossendorf
1 shared publication Elizabeth Mirowski
Electronics and Electrical Engineering Laboratory, National Institute of Standards and Technology, Boulder, Colorado 80305
1 shared publicationJohn Moreland
Electronics and Electrical Engineering Laboratory, National Institute of Standards and Technology, Boulder, Colorado 80305
1 shared publication
Latest Publications
- 20 March 2014
- Published by IOP Publishing in Applied Physics Express
- Vol. 7 (4)
Zero-field spin-transfer oscillators combining in-plane and out-of-plane magnetized layers
- 20 March 2014
- Published by IOP Publishing in Applied Physics Express
- Vol. 7 (4)
Zero-field spin-transfer oscillators combining in-plane and out-of-plane magnetized layers
- 14 November 2007
- Published by Springer Nature
- p. 93-156
High Speed Switching and Rotational Dynamics in Small Magnetic Thin Film Devices
- 14 November 2007
- Published by Springer Nature
- p. 93-156
High Speed Switching and Rotational Dynamics in Small Magnetic Thin Film Devices
- 8 March 2004
- Published by AIP Publishing in Applied Physics Letters
- Vol. 84 (10) , 1786-1788
Integrated microfluidic isolation platform for magnetic particle manipulation in biological systems
We have developed a micromachined fluid-cell platform that consists of patterned magnetic thin-film elements supported on a thin silicon–nitride membrane. In the presence of an external magnetic field, the field gradients near the magnetic elements are sufficiently large to trap magnetic particles that are separated from the patterned films by a 200 nm thick nitride membrane. The two main applications of this fluid-cell platform are to provide a means to control and position magnetic microparticles, which can be tethered to biological molecules, and also to sort superparamagnetic microparticles based on their size and magnetic susceptibility. We determine the characteristic trapping forces of each trap in the array by measuring the Brownian motion of the microparticle as a function of applied external field. Typical force constants and forces on the superparamagnetic particles are 4.8×10 −4 ±0.7×10 −4 N/m and 97±15 pN , respectively.
- 8 March 2004
- Published by AIP Publishing in Applied Physics Letters
- Vol. 84 (10) , 1786-1788
Integrated microfluidic isolation platform for magnetic particle manipulation in biological systems
We have developed a micromachined fluid-cell platform that consists of patterned magnetic thin-film elements supported on a thin silicon–nitride membrane. In the presence of an external magnetic field, the field gradients near the magnetic elements are sufficiently large to trap magnetic particles that are separated from the patterned films by a 200 nm thick nitride membrane. The two main applications of this fluid-cell platform are to provide a means to control and position magnetic microparticles, which can be tethered to biological molecules, and also to sort superparamagnetic microparticles based on their size and magnetic susceptibility. We determine the characteristic trapping forces of each trap in the array by measuring the Brownian motion of the microparticle as a function of applied external field. Typical force constants and forces on the superparamagnetic particles are 4.8×10 −4 ±0.7×10 −4 N/m and 97±15 pN , respectively.
- 15 May 2003
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 93 (10) , 7539-7544
High-frequency measurements of spin-valve films and devices (invited)
High-frequency measurements of spin-valve films and devices, made using several different measurement techniques, are presented and compared. Pulsed inductive measurements were made on sheet films and provide insight into the intrinsic dynamical properties of the component films and multilayer stacks. The damping parameter, in the completed spin-valve stack, is larger than in the constituent films. Direct time and frequency domain measurements of the dynamical response of micrometer-size spin-valve devices, made using high-bandwidth magnetoresistance techniques, showed damping parameters comparable to these measured on spin-valve sheet films. The small-angle magnetization response was also determined by high-frequency magnetic noise measurements. The damping parameters were smaller than those obtained by direct susceptibility measurements. The device-level measurements show a different dependence of the damping parameter on the easy-axis field as compared to sheet-level measurements. In addition to the uniform rotation mode, other peaks can be observed in the noise spectra that correspond to fluctuation modes arising from the micromagnetic structure. Electrical device measurements have much greater sensitivity than other high-frequency magnetic measurement techniques, which allow the direct observation of magnetization motion in submicrometer elements without averaging. This technique is used to directly examine thermally activated events and nonrepetitive dynamical motions.
- 15 May 2003
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 93 (10) , 7539-7544
High-frequency measurements of spin-valve films and devices (invited)
High-frequency measurements of spin-valve films and devices, made using several different measurement techniques, are presented and compared. Pulsed inductive measurements were made on sheet films and provide insight into the intrinsic dynamical properties of the component films and multilayer stacks. The damping parameter, in the completed spin-valve stack, is larger than in the constituent films. Direct time and frequency domain measurements of the dynamical response of micrometer-size spin-valve devices, made using high-bandwidth magnetoresistance techniques, showed damping parameters comparable to these measured on spin-valve sheet films. The small-angle magnetization response was also determined by high-frequency magnetic noise measurements. The damping parameters were smaller than those obtained by direct susceptibility measurements. The device-level measurements show a different dependence of the damping parameter on the easy-axis field as compared to sheet-level measurements. In addition to the uniform rotation mode, other peaks can be observed in the noise spectra that correspond to fluctuation modes arising from the micromagnetic structure. Electrical device measurements have much greater sensitivity than other high-frequency magnetic measurement techniques, which allow the direct observation of magnetization motion in submicrometer elements without averaging. This technique is used to directly examine thermally activated events and nonrepetitive dynamical motions.