Dimitris Katsenis
Research Subjects
Dimitris Katsenis has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
George Dendrinos
Orthopaedic Department, Euroclinic Athens, Argos, Greece
2 shared publicationsAntonis Kouris
From the *Orthopaedic Department, Argos General Hospital, Argos, Greece; and †1st Orthopaedic Department, Euroclinic Athens, Athens, Greece
1 shared publicationAthanasiou Vasilis
From the *Orthopaedic Department, General Hospital Argos, Argos, Greece; and †Orthopaedic Department, Patras University Rio, Patras, Greece
1 shared publicationDimitris Begkas
1 shared publicationDimitris Stamoulis
1 shared publicationElias Lambiris
From the *Orthopaedic Department, General Hospital Argos, Argos, Greece; and †Orthopaedic Department, Patras University Rio, Patras, Greece
1 shared publication
Latest Publications
- 1 April 2015
- Published by SLACK, Inc. in Orthopedics
- Vol. 38 (4) , e324-e330
Minimally Invasive Reconstruction of Acute Type IV and Type V Acromioclavicular Separations
The goal of this study was to evaluate the midterm radiologic, clinical, and functional results of the early reconstruction of the severe acromioclavicular joint dislocation using the flipptack fixation button technique. Between December 2006 and December 2009, one hundred thirty-five consecutive patients with acromioclavicular joint separations were admitted to the authors’ institution. Fifty patients were included in the study. According to Rockwood classification, 29 (58%) dislocations were type IV and 21 (42%) were type V. Surgery was performed at an average of 4.2 days (range, 0–12 days) after dislocation. All dislocations were treated with the flipptack fixation button technique. All patients were evaluated at a final postoperative follow-up of 42 months (range, 36–49 months). The clinical outcome was assessed using the Constant score. The functional limitation was assessed using the bother index of the short Musculoskeletal Function Assessment. Radiographs taken immediately postoperatively and at the final follow-up assessed acromioclavicular joint reduction, coracoclavicular distance, and joint arthrosis. At the final follow-up, mean Constant score was 93.04 (range, 84–100). The average (±SD) short Musculoskeletal Function Assessment bother index was 20.88±8.95 (range, 2.0–49). No statistically significant difference was found between the acromioclavicular joint dislocation type and the clinical result ( P =.227; chi-square, 6.910, Kruskal Wallis test). The regression of the coracoclavicular distance at final follow-up was not statistically significant ( P =.276; chi-square, 6.319, Kruskal Wallis test). The flipptack fixation button technique is an effective alternative for the treatment of severe acromioclavicular joint dislocation. Because all objectives of the treatment were obtained, the results do not deteriorate over time. [ Orthopedics. 2015; 38(4):e324–e330.]
- 1 April 2015
- Published by SLACK, Inc. in Orthopedics
- Vol. 38 (4) , e324-e330
Minimally Invasive Reconstruction of Acute Type IV and Type V Acromioclavicular Separations
The goal of this study was to evaluate the midterm radiologic, clinical, and functional results of the early reconstruction of the severe acromioclavicular joint dislocation using the flipptack fixation button technique. Between December 2006 and December 2009, one hundred thirty-five consecutive patients with acromioclavicular joint separations were admitted to the authors’ institution. Fifty patients were included in the study. According to Rockwood classification, 29 (58%) dislocations were type IV and 21 (42%) were type V. Surgery was performed at an average of 4.2 days (range, 0–12 days) after dislocation. All dislocations were treated with the flipptack fixation button technique. All patients were evaluated at a final postoperative follow-up of 42 months (range, 36–49 months). The clinical outcome was assessed using the Constant score. The functional limitation was assessed using the bother index of the short Musculoskeletal Function Assessment. Radiographs taken immediately postoperatively and at the final follow-up assessed acromioclavicular joint reduction, coracoclavicular distance, and joint arthrosis. At the final follow-up, mean Constant score was 93.04 (range, 84–100). The average (±SD) short Musculoskeletal Function Assessment bother index was 20.88±8.95 (range, 2.0–49). No statistically significant difference was found between the acromioclavicular joint dislocation type and the clinical result ( P =.227; chi-square, 6.910, Kruskal Wallis test). The regression of the coracoclavicular distance at final follow-up was not statistically significant ( P =.276; chi-square, 6.319, Kruskal Wallis test). The flipptack fixation button technique is an effective alternative for the treatment of severe acromioclavicular joint dislocation. Because all objectives of the treatment were obtained, the results do not deteriorate over time. [ Orthopedics. 2015; 38(4):e324–e330.]
- 1 March 2013
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 27 (3) , 153-157
The Reconstruction of Tibial Metaphyseal Comminution Using Hybrid Frames in Severe Tibial Plafond Fractures
Objectives: To evaluate the treatment alternatives for the management of the metaphyseal tibial comminution in severe plafond fractures, and to investigate the role of the fibula fracture fixation. Design: Retrospective clinical study. Setting: Level-2 trauma hospital. Participants: Patients with highly comminuted tibial plafond fractures. Intervention: All patients were treated with open reduction and internal fixation of the articular surface and external fixation of the metaphyseal fracture. If metaphyseal comminution was minimal, bone graft was applied and the fibular was plated (group 1); if comminution was between 1 and 3 cm, acute shortening and distraction osteogenesis was performed (group 2); and if comminution was >3 cm, distraction osteogenesis without acute shortening was performed (group 3). Main Outcome Measurements: Radiographic union, AOFAS ankle score. Results: Of 30 fractures, 15 fractures (50%) had an anatomic reduction of the joint. Union occurred in all but 2 fractures. Group 1 fractures healed at an average of 19 weeks (16–22). Four fractures had associated malalignment problems. The mean AOFAS score was 72.5 (range 45–100). Group 2 fractures healed at an average of 18.3 weeks (16–21). One fracture healed with 5-degrees of angulation. Group 3 fractures healed at an average of 17.5 weeks (14–24). Two fractures healed with malalignment. When groups 2 and 3 were combined to evaluate the AOFAS outcome for fractures treated with distraction osteogenesis, a score of 75.83 was obtained (45–90). There was no difference between the Group 1 versus combined Groups 2/3 with regard to this latter score (P = 0.372). Additionally, when fibula fixation (Group 1) was compared with those fractures where it was not performed (groups 2/3), no difference was seen (P = 0.276). Conclusions: The reconstruction of severe tibial plafond fractures treated with small wire hybrid fixation may be achieved by different techniques leading to a satisfactory result. The fixation of the fibula fracture is dependent mainly on the treatment chosen for the management of the metaphyseal lesion. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 March 2013
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 27 (3) , 153-157
The Reconstruction of Tibial Metaphyseal Comminution Using Hybrid Frames in Severe Tibial Plafond Fractures
Objectives: To evaluate the treatment alternatives for the management of the metaphyseal tibial comminution in severe plafond fractures, and to investigate the role of the fibula fracture fixation. Design: Retrospective clinical study. Setting: Level-2 trauma hospital. Participants: Patients with highly comminuted tibial plafond fractures. Intervention: All patients were treated with open reduction and internal fixation of the articular surface and external fixation of the metaphyseal fracture. If metaphyseal comminution was minimal, bone graft was applied and the fibular was plated (group 1); if comminution was between 1 and 3 cm, acute shortening and distraction osteogenesis was performed (group 2); and if comminution was >3 cm, distraction osteogenesis without acute shortening was performed (group 3). Main Outcome Measurements: Radiographic union, AOFAS ankle score. Results: Of 30 fractures, 15 fractures (50%) had an anatomic reduction of the joint. Union occurred in all but 2 fractures. Group 1 fractures healed at an average of 19 weeks (16–22). Four fractures had associated malalignment problems. The mean AOFAS score was 72.5 (range 45–100). Group 2 fractures healed at an average of 18.3 weeks (16–21). One fracture healed with 5-degrees of angulation. Group 3 fractures healed at an average of 17.5 weeks (14–24). Two fractures healed with malalignment. When groups 2 and 3 were combined to evaluate the AOFAS outcome for fractures treated with distraction osteogenesis, a score of 75.83 was obtained (45–90). There was no difference between the Group 1 versus combined Groups 2/3 with regard to this latter score (P = 0.372). Additionally, when fibula fixation (Group 1) was compared with those fractures where it was not performed (groups 2/3), no difference was seen (P = 0.276). Conclusions: The reconstruction of severe tibial plafond fractures treated with small wire hybrid fixation may be achieved by different techniques leading to a satisfactory result. The fixation of the fibula fracture is dependent mainly on the treatment chosen for the management of the metaphyseal lesion. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 August 2009
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 23 (7) , 493-501
Combination of Fine Wire Fixation and Limited Internal Fixation for High-Energy Tibial Plateau Fractures: Functional Results at Minimum 5-Year Follow-up
Objectives: To assess knee function and the development of knee arthrosis, at 3 and 5 years postoperatively, in high-energy tibial plateau fractures that were treated with minimal internal fixation augmented by small wire circular frames. Setting: Level II trauma hospital. Design: Retrospective study. Patients and Methods: Between October 1988 and December 1999, 145 consecutive high-energy tibial plateau fractures were treated with hybrid fixation including small wire circular or hybrid frames, minimal internal fixation, and occasionally provisional extension of the external fixation to the distal femur. One hundred twenty-seven patients with 129 fractures (89%) were included in the study. There were 68 (53%) C1, 20 (15%) C2, and 41 (32%) C3 fractures. Forty-seven (36.5%) of the total were open fractures. Clinical, subjective, objective, and radiographic results were evaluated at the time of union, at a minimum 3 years postoperatively, and at final minimum follow-up of 5 years. Results: Results were assessed according to the Honkonen-Jarvinen criteria. An excellent or good subjective result was noted in 106 fractures (82%) at a minimum 3-year follow-up, whereas an excellent or good score was achieved in 101 fractures (78%) at a minimum 5 years. A statistically significant deterioration (P = 0.001) of the post-traumatic radiographic arthritis was recorded at 5 years postoperatively. Conclusions: High-energy tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames yielded a high percentage of cases exhibiting radiographic post-traumatic arthritis. However, because all the objectives of fracture treatment seemed to be obtained, the functional results remain satisfactory over time.
- 1 August 2009
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 23 (7) , 493-501
Combination of Fine Wire Fixation and Limited Internal Fixation for High-Energy Tibial Plateau Fractures: Functional Results at Minimum 5-Year Follow-up
Objectives: To assess knee function and the development of knee arthrosis, at 3 and 5 years postoperatively, in high-energy tibial plateau fractures that were treated with minimal internal fixation augmented by small wire circular frames. Setting: Level II trauma hospital. Design: Retrospective study. Patients and Methods: Between October 1988 and December 1999, 145 consecutive high-energy tibial plateau fractures were treated with hybrid fixation including small wire circular or hybrid frames, minimal internal fixation, and occasionally provisional extension of the external fixation to the distal femur. One hundred twenty-seven patients with 129 fractures (89%) were included in the study. There were 68 (53%) C1, 20 (15%) C2, and 41 (32%) C3 fractures. Forty-seven (36.5%) of the total were open fractures. Clinical, subjective, objective, and radiographic results were evaluated at the time of union, at a minimum 3 years postoperatively, and at final minimum follow-up of 5 years. Results: Results were assessed according to the Honkonen-Jarvinen criteria. An excellent or good subjective result was noted in 106 fractures (82%) at a minimum 3-year follow-up, whereas an excellent or good score was achieved in 101 fractures (78%) at a minimum 5 years. A statistically significant deterioration (P = 0.001) of the post-traumatic radiographic arthritis was recorded at 5 years postoperatively. Conclusions: High-energy tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames yielded a high percentage of cases exhibiting radiographic post-traumatic arthritis. However, because all the objectives of fracture treatment seemed to be obtained, the functional results remain satisfactory over time.
- 1 April 2005
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 19 (4) , 241-248
Minimal Internal Fixation Augmented by Small Wire Transfixion Frames for High-Energy Tibial Plateau Fractures
Purpose: To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. Methods: This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Results: Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Conclusions: Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.
- 1 April 2005
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 19 (4) , 241-248
Minimal Internal Fixation Augmented by Small Wire Transfixion Frames for High-Energy Tibial Plateau Fractures
Purpose: To evaluate the outcome of bicondylar tibial plateau fractures treated with minimal internal fixation augmented by small wire external fixation frames and to assess the necessity of bridging the knee joint by extending the external fixation to the distal femur. Methods: This is a retrospective study of 48 tibial plateau fractures. There were 40 (83.5%) Schatzker type VI fractures, 8 Schatzker type V fractures, and 18 (37.5%) fractures were open. A complex injury according to the Tscherne-Lobenhoffer classification was recorded in 30 (62.5%) patients. All fractures were treated with combined minimally invasive internal and external fixation. Closed reduction was achieved in 32 (66.6%) of the fractures. Extension of the external fixation to the distal femur was done in 30 (62.5%) fractures. Results were assessed according to the criteria of Honkonen-Jarvinen. Results: Follow-up ranged from 28 to 60 months with an average of 38 months. All fractures but 1 united at an average of 13.5 weeks (range 11-18 weeks). One patient developed an infected nonunion of the diaphyseal segment of his fracture. Thirty-nine (81%) patients achieved an excellent or good radiologic result. An excellent or good final clinical result was recorded in 36 patients (76%). Bridging the knee joint did not affect significantly the result (P < 0.418). No significant correlation was found between the type of fracture and the final score (P < 0.458). Conclusions: Hybrid internal and external fixation combined with tibiofemoral extension of the fixation is an attractive treatment option for complex tibial plateau fractures.