Claudio Mucchino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Claudio Mucchino has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Monica Maffini
Dipartimento di Chimica Generale ed Inorganica, Chimica Analitica, Chimica Fisica, Università degli Studi di Parma, Parco Area delle Scienze 17/A, 43100 Parma, Italy
4 shared publications Alessandro Mangia
3 shared publications- Maria Careri
University of Parma
3 shared publications - Federica Bianchi
University of Parma
2 shared publications A. Mangia
Dipartimento di Chimica Generale ed Inorganica, Chimica Analitica, Chimica Fisica, Università degli Studi di Parma, Viale Usberti 17/A, 43100 Parma, Italy
1 shared publicationLisa Elviri
Dipartimento di Chimica Generale ed Inorganica, Chimica Analitica, Chimica Fisica, Università degli Studi di Parma, Viale G.P. Usberti 17/A, I‐43100 Parma, Italy
1 shared publication
Latest Publications
- 1 July 2010
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 6 (3) , 223-227
A Fast and Effective Routine Method Based on SPME and GC/ICP-MS for the Monitoring of Organotin Compounds in Surface and Sea Water
Abstract: The quality assessment of water in term of organometallic compounds is one of the key tasks of modern environmental analytical chemistry. For this purpose a rapid and very sensitive method based on solid-phase microextraction (SPME) followed by gas chromatography-inductively coupled plasma-mass spectrometry (GC-ICP-MS) was developed and validated aimed at the determination of dimethyl-, dibutyl- and tributyltin in water samples. A divinylbenzene/ carboxen/polidimethylsiloxane fiber was used for the SPME sample treatment. Coupling of the ICP-MS with GC was accomplished developing an easy-to-fit in-house interface. In general optimal conditions were found by using the enhanced “hot plasma/protective ion extraction” introduction system. Validation was carried out in terms of limit of detection, limit of quantitation, linearity, precision and trueness. GC-ICPMS made possible the detection of the organotin compounds at ultratrace levels, quantitation limits ranging from 0.04 to 5 ng l-1. Linearity was established over two orders of magnitude for all the investigated compounds. Good precision was obtained both in terms of intra-day repeatability and between-day precision on two concentration levels (RSD lower than 15%). Recovery values ranging from 75±2% to 99±1.2% (n = 3) were calculated. The method was proved rapid, GC-ICPMS allowing for the separation of organotin species in less than 7 minutes. The method was used in routine analysis of environmental samples (fresh and marine water samples).
- 1 July 2010
- Published by Bentham Science Publishers Ltd. in Current Analytical Chemistry
- Vol. 6 (3) , 223-227
A Fast and Effective Routine Method Based on SPME and GC/ICP-MS for the Monitoring of Organotin Compounds in Surface and Sea Water
Abstract: The quality assessment of water in term of organometallic compounds is one of the key tasks of modern environmental analytical chemistry. For this purpose a rapid and very sensitive method based on solid-phase microextraction (SPME) followed by gas chromatography-inductively coupled plasma-mass spectrometry (GC-ICP-MS) was developed and validated aimed at the determination of dimethyl-, dibutyl- and tributyltin in water samples. A divinylbenzene/ carboxen/polidimethylsiloxane fiber was used for the SPME sample treatment. Coupling of the ICP-MS with GC was accomplished developing an easy-to-fit in-house interface. In general optimal conditions were found by using the enhanced “hot plasma/protective ion extraction” introduction system. Validation was carried out in terms of limit of detection, limit of quantitation, linearity, precision and trueness. GC-ICPMS made possible the detection of the organotin compounds at ultratrace levels, quantitation limits ranging from 0.04 to 5 ng l-1. Linearity was established over two orders of magnitude for all the investigated compounds. Good precision was obtained both in terms of intra-day repeatability and between-day precision on two concentration levels (RSD lower than 15%). Recovery values ranging from 75±2% to 99±1.2% (n = 3) were calculated. The method was proved rapid, GC-ICPMS allowing for the separation of organotin species in less than 7 minutes. The method was used in routine analysis of environmental samples (fresh and marine water samples).
- 1 September 2008
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 48 (2) , 435-439
Development and validation of an inductively coupled plasma mass spectrometry method with optimized microwave-assisted sample digestion for the determination of platinum at ultratrace levels in plasma and ultrafiltrate plasma
- 1 September 2008
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 48 (2) , 435-439
Development and validation of an inductively coupled plasma mass spectrometry method with optimized microwave-assisted sample digestion for the determination of platinum at ultratrace levels in plasma and ultrafiltrate plasma
- 21 February 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (6) , 807-811
Determination of peanut allergens in cereal‐chocolate‐based snacks: metal‐tag inductively coupled plasma mass spectrometry immunoassay versus liquid chromatography/electrospray ionization tandem mass spectrometry
A comparison of two methods for the identification and determination of peanut allergens based on europium (Eu)‐tagged inductively coupled plasma mass spectrometry (ICP‐MS) immunoassay and on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) with a triple quadrupole mass analyzer was carried out on a complex food matrix like a chocolate rice crispy‐based snack. The LC/MS/MS method was based on the determination of four different peptide biomarkers selective for the Ara h2 and Ara h3/4 peanut proteins. The performance of this method was compared with that of a non‐competitive sandwich enzyme‐linked immunosorbent assay (ELISA) method with ICP‐MS detection of the metal used to tag the antibody for the quantitative peanut protein analysis in food. The limit of detection (LOD) and quantitation of the ICP‐MS immunoassay were 2.2 and 5 µg peanuts g −1 matrix, respectively, the recovery ranged from 86 ± 18% to 110 ± 4% and linearity was proved in the 5–50 µg g −1 range. The LC/MS/MS method allowed us to obtain LODs of 1 and 5 µg protein g −1 matrix for Ara h3/4 and Ara h2, respectively, thus obtaining significantly higher values with respect to the ELISA ICP‐MS method, taking into account the different expression for concentrations. Linearity was established in the 10–200 µg g −1 range of peanut proteins in the food matrix investigated and good precision (RSD <10%) was demonstrated. Both the two approaches, used for screening or confirmative purposes, showed the power of mass spectrometry when used as a very selective detector in difficult matrices even if some limitations still exist, i.e. matrix suppression in the LC/ESI‐MS/MS procedure and the change of the Ag/Ab binding with matrix in the ICP‐MS method. Copyright © 2008 John Wiley & Sons, Ltd.
- 21 February 2008
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 22 (6) , 807-811
Determination of peanut allergens in cereal‐chocolate‐based snacks: metal‐tag inductively coupled plasma mass spectrometry immunoassay versus liquid chromatography/electrospray ionization tandem mass spectrometry
A comparison of two methods for the identification and determination of peanut allergens based on europium (Eu)‐tagged inductively coupled plasma mass spectrometry (ICP‐MS) immunoassay and on liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI‐MS/MS) with a triple quadrupole mass analyzer was carried out on a complex food matrix like a chocolate rice crispy‐based snack. The LC/MS/MS method was based on the determination of four different peptide biomarkers selective for the Ara h2 and Ara h3/4 peanut proteins. The performance of this method was compared with that of a non‐competitive sandwich enzyme‐linked immunosorbent assay (ELISA) method with ICP‐MS detection of the metal used to tag the antibody for the quantitative peanut protein analysis in food. The limit of detection (LOD) and quantitation of the ICP‐MS immunoassay were 2.2 and 5 µg peanuts g −1 matrix, respectively, the recovery ranged from 86 ± 18% to 110 ± 4% and linearity was proved in the 5–50 µg g −1 range. The LC/MS/MS method allowed us to obtain LODs of 1 and 5 µg protein g −1 matrix for Ara h3/4 and Ara h2, respectively, thus obtaining significantly higher values with respect to the ELISA ICP‐MS method, taking into account the different expression for concentrations. Linearity was established in the 10–200 µg g −1 range of peanut proteins in the food matrix investigated and good precision (RSD <10%) was demonstrated. Both the two approaches, used for screening or confirmative purposes, showed the power of mass spectrometry when used as a very selective detector in difficult matrices even if some limitations still exist, i.e. matrix suppression in the LC/ESI‐MS/MS procedure and the change of the Ag/Ab binding with matrix in the ICP‐MS method. Copyright © 2008 John Wiley & Sons, Ltd.
- 7 August 2006
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 21 (9) , 970-973
Optimization of the solid phase microextraction procedure for the ultra-trace determination of organotin compounds by gas chromatography-inductively coupled plasma-mass spectrometry
A chemometric approach based on experimental design and desirability functions was used to develop and validate a SPME-GC-ICP-MS method for the determination of the organotin compounds dimethyltin, tributyltin and dibuthyltin. Three different SPME coatings were evaluated, obtaining the best results by using the divinylbenzene/carboxen/polydimethylsiloxane 2 cm 50/30 μm fibre. The optimal extraction conditions were found to be the following: T = 30 °C, t = 40 min and pH = 4. Method validation was performed by determining the most relevant quality parameters such as detection limit, quantitation limit, repeatability and intermediate precision. LOD values in the 0.2–8 ng L−1 were obtained.
- 7 August 2006
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 21 (9) , 970-973
Optimization of the solid phase microextraction procedure for the ultra-trace determination of organotin compounds by gas chromatography-inductively coupled plasma-mass spectrometry
A chemometric approach based on experimental design and desirability functions was used to develop and validate a SPME-GC-ICP-MS method for the determination of the organotin compounds dimethyltin, tributyltin and dibuthyltin. Three different SPME coatings were evaluated, obtaining the best results by using the divinylbenzene/carboxen/polydimethylsiloxane 2 cm 50/30 μm fibre. The optimal extraction conditions were found to be the following: T = 30 °C, t = 40 min and pH = 4. Method validation was performed by determining the most relevant quality parameters such as detection limit, quantitation limit, repeatability and intermediate precision. LOD values in the 0.2–8 ng L−1 were obtained.