Danai Laksameethanasan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Danai Laksameethanasan has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Lit-Hsin Loo
Bioinformatics Institute (BII) 17 Singapore, Singapore
2 shared publications - Sami Sebastian Brandt
IT University of Copenhagen, Copenhagen, Denmark
2 shared publications Adom Giffin
1 shared publicationAriel Caticha
1 shared publicationCarlos C. Rodríguez
1 shared publicationChinnachart Vootita
1 shared publication
Latest Publications
- Open Access
- 6 March 2014
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 10 (3) , e1003504
Quantitative Protein Localization Signatures Reveal an Association between Spatial and Functional Divergences of Proteins
Protein subcellular localization is a major determinant of protein function. However, this important protein feature is often described in terms of discrete and qualitative categories of subcellular compartments, and therefore it has limited applications in quantitative protein function analyses. Here, we present Protein Localization Analysis and Search Tools (PLAST), an automated analysis framework for constructing and comparing quantitative signatures of protein subcellular localization patterns based on microscopy images. PLAST produces human-interpretable protein localization maps that quantitatively describe the similarities in the localization patterns of proteins and major subcellular compartments, without requiring manual assignment or supervised learning of these compartments. Using the budding yeast Saccharomyces cerevisiae as a model system, we show that PLAST is more accurate than existing, qualitative protein localization annotations in identifying known co-localized proteins. Furthermore, we demonstrate that PLAST can reveal protein localization-function relationships that are not obvious from these annotations. First, we identified proteins that have similar localization patterns and participate in closely-related biological processes, but do not necessarily form stable complexes with each other or localize at the same organelles. Second, we found an association between spatial and functional divergences of proteins during evolution. Surprisingly, as proteins with common ancestors evolve, they tend to develop more diverged subcellular localization patterns, but still occupy similar numbers of compartments. This suggests that divergence of protein localization might be more frequently due to the development of more specific localization patterns over ancestral compartments than the occupation of new compartments. PLAST enables systematic and quantitative analyses of protein localization-function relationships, and will be useful to elucidate protein functions and how these functions were acquired in cells from different organisms or species. A public web interface of PLAST is available at http://plast.bii.a-star.edu.sg. Proteins are fundamental building blocks of cells. They perform a variety of biological functions, many of which are essential to the vitality and normal functioning of cells. Proteins have to be located at the appropriate regions inside a cell to perform their functions. Therefore, when proteins change their locations, they may acquire new or different functions. However, the relationships between the locations and functions of proteins are difficult to analyze because protein locations are often represented in distinct and manually-defined categories of subcellular regions. Many proteins have complex or subtle differences in their localization patterns that can be hardly represented by these categories. Here, we present an automated analysis tool for generating quantitative signatures of protein localization patterns without requiring manual or automated assignments of proteins into distinct categories. We show that our tool can identify proteins located at the same subcellular regions more accurately than existing categorization-based methods. Our tool allows comprehensive and more accurate studies of the relationships between protein localizations and functions. By knowing where proteins are located and how their locations were changed, we may discover their functions and better understand how they acquire these functions.
- 6 March 2014
- Published by Public Library of Science (PLoS) in PLOS Computational Biology
- Vol. 10 (3) , e1003504
Open AccessQuantitative Protein Localization Signatures Reveal an Association between Spatial and Functional Divergences of Proteins
Protein subcellular localization is a major determinant of protein function. However, this important protein feature is often described in terms of discrete and qualitative categories of subcellular compartments, and therefore it has limited applications in quantitative protein function analyses. Here, we present Protein Localization Analysis and Search Tools (PLAST), an automated analysis framework for constructing and comparing quantitative signatures of protein subcellular localization patterns based on microscopy images. PLAST produces human-interpretable protein localization maps that quantitatively describe the similarities in the localization patterns of proteins and major subcellular compartments, without requiring manual assignment or supervised learning of these compartments. Using the budding yeast Saccharomyces cerevisiae as a model system, we show that PLAST is more accurate than existing, qualitative protein localization annotations in identifying known co-localized proteins. Furthermore, we demonstrate that PLAST can reveal protein localization-function relationships that are not obvious from these annotations. First, we identified proteins that have similar localization patterns and participate in closely-related biological processes, but do not necessarily form stable complexes with each other or localize at the same organelles. Second, we found an association between spatial and functional divergences of proteins during evolution. Surprisingly, as proteins with common ancestors evolve, they tend to develop more diverged subcellular localization patterns, but still occupy similar numbers of compartments. This suggests that divergence of protein localization might be more frequently due to the development of more specific localization patterns over ancestral compartments than the occupation of new compartments. PLAST enables systematic and quantitative analyses of protein localization-function relationships, and will be useful to elucidate protein functions and how these functions were acquired in cells from different organisms or species. A public web interface of PLAST is available at http://plast.bii.a-star.edu.sg. Proteins are fundamental building blocks of cells. They perform a variety of biological functions, many of which are essential to the vitality and normal functioning of cells. Proteins have to be located at the appropriate regions inside a cell to perform their functions. Therefore, when proteins change their locations, they may acquire new or different functions. However, the relationships between the locations and functions of proteins are difficult to analyze because protein locations are often represented in distinct and manually-defined categories of subcellular regions. Many proteins have complex or subtle differences in their localization patterns that can be hardly represented by these categories. Here, we present an automated analysis tool for generating quantitative signatures of protein localization patterns without requiring manual or automated assignments of proteins into distinct categories. We show that our tool can identify proteins located at the same subcellular regions more accurately than existing categorization-based methods. Our tool allows comprehensive and more accurate studies of the relationships between protein localizations and functions. By knowing where proteins are located and how their locations were changed, we may discover their functions and better understand how they acquire these functions.
- Open Access
- 22 October 2013
- Published by Springer Nature in BMC Bioinformatics
- Vol. 14 (S16) , S4
cellXpress: a fast and user-friendly software platform for profiling cellular phenotypes
High-throughput, image-based screens of cellular responses to genetic or chemical perturbations generate huge numbers of cell images. Automated analysis is required to quantify and compare the effects of these perturbations. However, few of the current freely-available bioimage analysis software tools are optimized for efficient handling of these images. Even fewer of them are designed to transform the phenotypic features measured from these images into discriminative profiles that can reveal biologically meaningful associations among the tested perturbations.
- 22 October 2013
- Published by Springer Nature in BMC Bioinformatics
- Vol. 14 (S16) , S4
Open AccesscellXpress: a fast and user-friendly software platform for profiling cellular phenotypes
High-throughput, image-based screens of cellular responses to genetic or chemical perturbations generate huge numbers of cell images. Automated analysis is required to quantify and compare the effects of these perturbations. However, few of the current freely-available bioimage analysis software tools are optimized for efficient handling of these images. Even fewer of them are designed to transform the phenotypic features measured from these images into discriminative profiles that can reveal biologically meaningful associations among the tested perturbations.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 100-105
A Computational Method for Tracking and Analysing Dynamic Phenotypes of Individual Macromolecules
Fluorescence time-lapse microscopic imaging is a powerful tool for investigating dynamic cellular processes. To date, automated fluorescence microscopes are increasingly used to generate high-content spatial-temporal image data at high-throughput. Such large-scale data require much computational effort to quantify complex macromolecular dynamics such as temporal changes in fluorescence intensity, spatial locations, trajectory and velocity. Here, we propose a semi-automated method for tracking dynamics of individual macromolecules and performed quantitative analysis of the extracted phenotypes. We compared our proposed method with the manual identification of macromolecules and with a particle tracking method provided by the image analysis software, ImageJ. Our results clearly provide more object trajectories than the ImageJ method and our phenotypic analysis illustrates the relationship between two significant features with human-interpretable visualization.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 100-105
A Computational Method for Tracking and Analysing Dynamic Phenotypes of Individual Macromolecules
Fluorescence time-lapse microscopic imaging is a powerful tool for investigating dynamic cellular processes. To date, automated fluorescence microscopes are increasingly used to generate high-content spatial-temporal image data at high-throughput. Such large-scale data require much computational effort to quantify complex macromolecular dynamics such as temporal changes in fluorescence intensity, spatial locations, trajectory and velocity. Here, we propose a semi-automated method for tracking dynamics of individual macromolecules and performed quantitative analysis of the extracted phenotypes. We compared our proposed method with the manual identification of macromolecules and with a particle tracking method provided by the image analysis software, ImageJ. Our results clearly provide more object trajectories than the ImageJ method and our phenotypic analysis illustrates the relationship between two significant features with human-interpretable visualization.
- 1 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (7) , 1719-1728
A Bayesian Reconstruction Method with Marginalized Uncertainty Model for Camera Motion in Microrotation Imaging
Reconstruction of a 3-D structure from multiple projection images requires prior knowledge of projection directions or camera motion parameters that describe the relative positions and orientations of 3-D structure with respect to the camera. These parameters can be estimated using, for instance, the conventional correlation alignment and feature-based methods. However, the alignment methods are not perfect, where the inaccuracy of the estimated motion parameters causes artifacts in the reconstruction. To overcome this problem, we propose a Bayesian approach to reconstruct the object that takes the motion uncertainty distribution into account. Moreover, we consider the motion parameters as nuisance parameters and integrate them out from the posterior distribution, assuming a Gaussian uncertainty model, which yields a statistical cost function to be minimized. The proposed method is applied in microrotation fluorescence imaging, where we aim at 3-D reconstruction of a rotating object from an image series, acquired by an optical microscope. The experiments with simulated and real microrotation datasets demonstrate that the proposed method provides visually and numerically better results than the traditional reconstruction methods, which ignore the uncertainty of the motion estimates.
- 1 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 57 (7) , 1719-1728
A Bayesian Reconstruction Method with Marginalized Uncertainty Model for Camera Motion in Microrotation Imaging
Reconstruction of a 3-D structure from multiple projection images requires prior knowledge of projection directions or camera motion parameters that describe the relative positions and orientations of 3-D structure with respect to the camera. These parameters can be estimated using, for instance, the conventional correlation alignment and feature-based methods. However, the alignment methods are not perfect, where the inaccuracy of the estimated motion parameters causes artifacts in the reconstruction. To overcome this problem, we propose a Bayesian approach to reconstruct the object that takes the motion uncertainty distribution into account. Moreover, we consider the motion parameters as nuisance parameters and integrate them out from the posterior distribution, assuming a Gaussian uncertainty model, which yields a statistical cost function to be minimized. The proposed method is applied in microrotation fluorescence imaging, where we aim at 3-D reconstruction of a rotating object from an image series, acquired by an optical microscope. The experiments with simulated and real microrotation datasets demonstrate that the proposed method provides visually and numerically better results than the traditional reconstruction methods, which ignore the uncertainty of the motion estimates.
- 13 November 2008
- Published by IOP Publishing in Inverse Problems
- Vol. 25 (1)
Dual filtered backprojection for micro-rotation confocal microscopy
Micro-rotation confocal microscopy is a novel optical imaging technique which employs dielectric fields to trap and rotate individual cells to facilitate 3D fluorescence imaging using a confocal microscope. In contrast to computed tomography (CT) where an image can be modelled as parallel projection of an object, the ideal confocal image is recorded as a central slice of the object corresponding to the focal plane. In CT, the projection images and the 3D object are related by the Fourier slice theorem which states that the Fourier transform of a CT image is equal to the central slice of the Fourier transform of the 3D object. In the micro-rotation application, we have a dual form of this setting, i.e. the Fourier transform of the confocal image equals the parallel projection of the Fourier transform of the 3D object. Based on the observed duality, we present here the dual of the classical filtered back projection (FBP) algorithm and apply it in micro-rotation confocal imaging. Our experiments on real data demonstrate that the proposed method is a fast and reliable algorithm for the micro-rotation application, as FBP is for CT application.
- 13 November 2008
- Published by IOP Publishing in Inverse Problems
- Vol. 25 (1)
Dual filtered backprojection for micro-rotation confocal microscopy
Micro-rotation confocal microscopy is a novel optical imaging technique which employs dielectric fields to trap and rotate individual cells to facilitate 3D fluorescence imaging using a confocal microscope. In contrast to computed tomography (CT) where an image can be modelled as parallel projection of an object, the ideal confocal image is recorded as a central slice of the object corresponding to the focal plane. In CT, the projection images and the 3D object are related by the Fourier slice theorem which states that the Fourier transform of a CT image is equal to the central slice of the Fourier transform of the 3D object. In the micro-rotation application, we have a dual form of this setting, i.e. the Fourier transform of the confocal image equals the parallel projection of the Fourier transform of the 3D object. Based on the observed duality, we present here the dual of the classical filtered back projection (FBP) algorithm and apply it in micro-rotation confocal imaging. Our experiments on real data demonstrate that the proposed method is a fast and reliable algorithm for the micro-rotation application, as FBP is for CT application.
- 28 November 2007
- Published by Wiley in Microscopy Research and Technique
- Vol. 71 (2) , 158-167
A Bayesian reconstruction method for micro‐rotation imaging in light microscopy
The authors present a three‐dimensional (3D) reconstruction algorithm and reconstruction‐based deblurring method for light microscopy using a micro‐rotation device. In contrast to conventional 3D optical imaging where the focal plane is shifted along the optical axis, micro‐rotation imaging employs dielectric fields to rotate the object inside a fixed optical set‐up. To address this entirely new 3D‐imaging modality, the authors present a reconstruction algorithm based on Bayesian inversion theory and use the total variation function as a structure prior. The spectral properties of the reconstruction by simulations that illustrate the strengths and the weaknesses of the micro‐rotation approach, compared with conventional 3D optical imaging, were studied. The reconstruction from real data sets shows that this method is promising for 3D reconstruction and offers itself as a deblurring method using a reconstruction‐based procedure for removing out‐of‐focus light from the micro‐rotation image series. Microsc. Res. Tech., 2008.
- 28 November 2007
- Published by Wiley in Microscopy Research and Technique
- Vol. 71 (2) , 158-167
A Bayesian reconstruction method for micro‐rotation imaging in light microscopy
The authors present a three‐dimensional (3D) reconstruction algorithm and reconstruction‐based deblurring method for light microscopy using a micro‐rotation device. In contrast to conventional 3D optical imaging where the focal plane is shifted along the optical axis, micro‐rotation imaging employs dielectric fields to rotate the object inside a fixed optical set‐up. To address this entirely new 3D‐imaging modality, the authors present a reconstruction algorithm based on Bayesian inversion theory and use the total variation function as a structure prior. The spectral properties of the reconstruction by simulations that illustrate the strengths and the weaknesses of the micro‐rotation approach, compared with conventional 3D optical imaging, were studied. The reconstruction from real data sets shows that this method is promising for 3D reconstruction and offers itself as a deblurring method using a reconstruction‐based procedure for removing out‐of‐focus light from the micro‐rotation image series. Microsc. Res. Tech., 2008.
- 1 January 2007
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 954 (1) , 354-361
Generalised Skilling–Bryan Minimisation for Micro-Rotation Imaging in Light Microscopy
The original Skilling–Bryan method, first introduced in the field of astronomy, minimises the statistical cost function assuming Gaussian noise and the entropy prior functional. In contrast to the conventional trust region methods, where the solution search in a high‐dimensional space may be very expensive, the Skilling–Bryan scheme minimises the cost function in a subspace instead, yielding much more efficient computation. However, in low‐photon‐count processes, such as image formation in confocal microscopy, Poisson noise assumption is more suitable. In addition, it would be desirable to use the 2nd order, Skilling–Bryan optimisation framework in applications where general prior functionals with the positivity constraint is required. In this work, we hence generalise the Skilling–Bryan method to be used with the Poisson noise model as well as with various kinds of prior functions including the total variation prior. The proposed method is generic whereas here it is applied in the micro‐rotation imaging, where we aim at 3D reconstruction of a rotating object from 2D projections taken by a light microscope. On the basis of our investigation, the extended Skilling–Bryan method is promising for computing estimates in high‐dimensional problems efficiently.
- 1 January 2007
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 954 (1) , 354-361
Generalised Skilling–Bryan Minimisation for Micro-Rotation Imaging in Light Microscopy
The original Skilling–Bryan method, first introduced in the field of astronomy, minimises the statistical cost function assuming Gaussian noise and the entropy prior functional. In contrast to the conventional trust region methods, where the solution search in a high‐dimensional space may be very expensive, the Skilling–Bryan scheme minimises the cost function in a subspace instead, yielding much more efficient computation. However, in low‐photon‐count processes, such as image formation in confocal microscopy, Poisson noise assumption is more suitable. In addition, it would be desirable to use the 2nd order, Skilling–Bryan optimisation framework in applications where general prior functionals with the positivity constraint is required. In this work, we hence generalise the Skilling–Bryan method to be used with the Poisson noise model as well as with various kinds of prior functions including the total variation prior. The proposed method is generic whereas here it is applied in the micro‐rotation imaging, where we aim at 3D reconstruction of a rotating object from 2D projections taken by a light microscope. On the basis of our investigation, the extended Skilling–Bryan method is promising for computing estimates in high‐dimensional problems efficiently.
- 25 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 30, 1276-1279
A Three-Dimensional Bayesian Reconstruction Method with the Point Spread Function for Micro-Rotation Sequences in Wide-Field Microscopy
In this paper, we present a three-dimensional (3D) reconstruc- tion algorithm for light microscopy supplied with a micro- rotation device. In contrast to the traditional optical section- ing techniques where the focal plane is shifted along the op- tical axis, in micro-rotation imaging, the object rotates where the focal plane is kept in a fixed position. Our reconstruction algorithm is based on Bayesian inversion theory where the imaging model is described by the 3D point spread function (PSF). The results show that the approach is promising for 3D reconstruction of rotating objects in wide-field light mi- croscopy, as an improvement for the effective 3D resolution is provided.
- 25 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 30, 1276-1279
A Three-Dimensional Bayesian Reconstruction Method with the Point Spread Function for Micro-Rotation Sequences in Wide-Field Microscopy
In this paper, we present a three-dimensional (3D) reconstruc- tion algorithm for light microscopy supplied with a micro- rotation device. In contrast to the traditional optical section- ing techniques where the focal plane is shifted along the op- tical axis, in micro-rotation imaging, the object rotates where the focal plane is kept in a fixed position. Our reconstruction algorithm is based on Bayesian inversion theory where the imaging model is described by the 3D point spread function (PSF). The results show that the approach is promising for 3D reconstruction of rotating objects in wide-field light mi- croscopy, as an improvement for the effective 3D resolution is provided.