Ji Yi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ji Yi has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Jeremy D. Rogers
Affiliation Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, United States of America
2 shared publications - Vadim Backman
Department of Biomedical Engineering, Northwestern University, Evanston, USA
2 shared publications Xu Li
Biomedical Engineering Department, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208, USA
2 shared publications- Alex Rosenthal
Northwestern University Department of Civil and Environmental Engineering, Evanston, Illinois, USA
1 shared publication Allen Taflove
Department of Electronic Engineering and Computer Science, Northwestern University, 2145 Sheridan Rd., Evanston, IL 60208, USA
1 shared publicationAndrew J. Radosevich
Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Rd.,Evanston, IL 60208, USA
1 shared publication
Latest Publications
- 1 January 2015
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2015 (14) , 4736-4745
Quantitative Image Analysis of Mesoscale Biofilm Structure with Optical Coherence Tomography
- 1 January 2015
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2015 (14) , 4736-4745
Quantitative Image Analysis of Mesoscale Biofilm Structure with Optical Coherence Tomography
- 4 April 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (7) , 9043-9059
Can OCT be sensitive to nanoscale structural alterations in biological tissue?
Exploration of nanoscale tissue structures is crucial in understanding biological processes. Although novel optical microscopy methods have been developed to probe cellular features beyond the diffraction limit, nanometer-scale quantification remains still inaccessible for in situ tissue. Here we demonstrate that, without actually resolving specific geometrical feature, OCT can be sensitive to tissue structural properties at the nanometer length scale. The statistical mass-density distribution in tissue is quantified by its autocorrelation function modeled by the Whittle-Mateŕn functional family. By measuring the wavelength-dependent backscattering coefficient μb(λ) and the scattering coefficient μs, we introduce a technique called inverse spectroscopic OCT (ISOCT) to quantify the mass-density correlation function. We find that the length scale of sensitivity of ISOCT ranges from ~30 to ~450 nm. Although these sub-diffractional length scales are below the spatial resolution of OCT and therefore not resolvable, they are nonetheless detectable. The sub-diffractional sensitivity is validated by 1) numerical simulations; 2) tissue phantom studies; and 3) ex vivo colon tissue measurements cross-validated by scanning electron microscopy (SEM). Finally, the 3D imaging capability of ISOCT is demonstrated with ex vivo rat buccal and human colon samples.
- 4 April 2013
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (7) , 9043-9059
Can OCT be sensitive to nanoscale structural alterations in biological tissue?
Exploration of nanoscale tissue structures is crucial in understanding biological processes. Although novel optical microscopy methods have been developed to probe cellular features beyond the diffraction limit, nanometer-scale quantification remains still inaccessible for in situ tissue. Here we demonstrate that, without actually resolving specific geometrical feature, OCT can be sensitive to tissue structural properties at the nanometer length scale. The statistical mass-density distribution in tissue is quantified by its autocorrelation function modeled by the Whittle-Mateŕn functional family. By measuring the wavelength-dependent backscattering coefficient μb(λ) and the scattering coefficient μs, we introduce a technique called inverse spectroscopic OCT (ISOCT) to quantify the mass-density correlation function. We find that the length scale of sensitivity of ISOCT ranges from ~30 to ~450 nm. Although these sub-diffractional length scales are below the spatial resolution of OCT and therefore not resolvable, they are nonetheless detectable. The sub-diffractional sensitivity is validated by 1) numerical simulations; 2) tissue phantom studies; and 3) ex vivo colon tissue measurements cross-validated by scanning electron microscopy (SEM). Finally, the 3D imaging capability of ISOCT is demonstrated with ex vivo rat buccal and human colon samples.
- 11 June 2010
- Published by Optica Publishing Group in Optics Letters
- Vol. 35 (12) , 2094-2096
Estimation of oxygen saturation from erythrocytes by high-resolution spectroscopic optical coherence tomography
We demonstrate the feasibility of estimating hemoglobin oxygen saturation () from erythrocytes over a visible wavelength band using high-resolution spectroscopic optical coherence tomography (SOCT). We take SOCT spectra from individual cells on in vitro human blood phantoms and calculate by fitting the spectra to an analytical model. We also use diffusive spectroscopy (DS) measurements, which is validated by direct measurement of oxygen partial pressure, as a comparison. The result shows a reliable linear association between the derived from SOCT and the DS measurement, indicating this methodology has potential on in vivo applications to evaluate blood oxygenation.- 11 June 2010
- Published by Optica Publishing Group in Optics Letters
- Vol. 35 (12) , 2094-2096
Estimation of oxygen saturation from erythrocytes by high-resolution spectroscopic optical coherence tomography
We demonstrate the feasibility of estimating hemoglobin oxygen saturation () from erythrocytes over a visible wavelength band using high-resolution spectroscopic optical coherence tomography (SOCT). We take SOCT spectra from individual cells on in vitro human blood phantoms and calculate by fitting the spectra to an analytical model. We also use diffusive spectroscopy (DS) measurements, which is validated by direct measurement of oxygen partial pressure, as a comparison. The result shows a reliable linear association between the derived from SOCT and the DS measurement, indicating this methodology has potential on in vivo applications to evaluate blood oxygenation.- 17 July 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (15) , 13157-13167
Analyzing absorption and scattering spectra of micro-scale structures with spectroscopic optical coherence tomography
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
- 17 July 2009
- Published by Optica Publishing Group in Optics Express
- Vol. 17 (15) , 13157-13167
Analyzing absorption and scattering spectra of micro-scale structures with spectroscopic optical coherence tomography
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.