Martin Petriska
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Martin Petriska has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Vladimír Slugeň
Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of technology in Bratislava, Ilkovičova 3, 81219 Bratislava, Slovakia
6 shared publications - Stanislav Sojak
Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of technology in Bratislava, Ilkovičova 3, 81219 Bratislava, Slovakia
5 shared publications - Vladimir Krsjak
Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Bratislava, Slovakia
5 shared publications - Jarmila Degmová
Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of technology in Bratislava, Ilkovičova 3, 81219 Bratislava, Slovakia
3 shared publications - Pavol Noga
Slovak Univ Technol, Fac Mat Sci & Technol, Adv Technol Res Inst, Jana Bottu 2781-25, Trnava 91724, Slovakia
3 shared publications - Jana Simeg Veternikova
Institute of Nuclear and Physical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 812 19 Bratislava, Slovakia
2 shared publications
Latest Publications
- Open Access
Application of Proton Irradiation in the Study of Accelerated Radiation Ageing in a GaAs Semiconductor
Proton irradiation experiments have been used as a surrogate for studying radiation effects in numerous materials for decades. The abundance and accessibility of proton accelerators make this approach convenient for conducting accelerated radiation ageing studies. However, developing new materials with improved radiation stability requires numerous model materials, test samples, and very effective utilization of the accelerator beam time. Therefore, the question of optimal beam current, or particle flux, is critical and needs to be adequately understood. In this work, we used 5 MeV protons to introduce displacement damage in gallium arsenide samples using a wide range of flux values. Positron annihilation lifetime spectroscopy was used to quantitatively assess the concentration of radiation-induced survived vacancies. The results show that proton fluxes in range between 1011 and 1012 cm−2.s−1 lead to a similar concentration of monovacancies generated in the GaAs semiconductor material, while a further increase in the flux leads to a sharp drop in this concentration.
Open AccessApplication of Proton Irradiation in the Study of Accelerated Radiation Ageing in a GaAs Semiconductor
Proton irradiation experiments have been used as a surrogate for studying radiation effects in numerous materials for decades. The abundance and accessibility of proton accelerators make this approach convenient for conducting accelerated radiation ageing studies. However, developing new materials with improved radiation stability requires numerous model materials, test samples, and very effective utilization of the accelerator beam time. Therefore, the question of optimal beam current, or particle flux, is critical and needs to be adequately understood. In this work, we used 5 MeV protons to introduce displacement damage in gallium arsenide samples using a wide range of flux values. Positron annihilation lifetime spectroscopy was used to quantitatively assess the concentration of radiation-induced survived vacancies. The results show that proton fluxes in range between 1011 and 1012 cm−2.s−1 lead to a similar concentration of monovacancies generated in the GaAs semiconductor material, while a further increase in the flux leads to a sharp drop in this concentration.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2778 (1) , 060007
Combined triple coincidence positron lifetime and coincidence Doppler broadening measurement setup
A triple coincidence digital positron lifetime setup (PALS) was combined with a coincidence Doppler broadening system (CDBS) in our laboratory to handle both me
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2778 (1) , 060007
Open AccessCombined triple coincidence positron lifetime and coincidence Doppler broadening measurement setup
A triple coincidence digital positron lifetime setup (PALS) was combined with a coincidence Doppler broadening system (CDBS) in our laboratory to handle both me
- Open Access
Positron Annihilation Study of RPV Steels Radiation Loaded by Hydrogen Ion Implantation
Specimens of 15Kh2MFAA steel used for reactor pressure vessels V-213 (VVER-440 reactor) were studied by positron annihilation techniques in terms of their radiation resistance and structural recovery after thermal treatment. The radiation load was simulated by experimental implantation of 500 keV H+ ions. The maximum radiation damage of 1 DPA was obtained across a region of 3 µm. Radiation-induced defects were investigated by coincidence Doppler broadening spectroscopy and positron lifetime spectroscopy using a conventional positron source as well as a slow positron beam. All techniques registered an accumulation of small open-volume defects (mostly mono- and di-vacancies) due to the irradiation, with an increase of the defect volume ΔVD ≈ 2.88 × 10−8 cm−3. Finally, the irradiated specimens were gradually annealed at temperatures from 200 to 550 °C and analyzed in detail. The best defect recovery was found at a temperature between 450 and 475 °C, but the final defect concentration of about ΔCD = 0.34 ppm was still higher than in the as-received specimens.
Open AccessPositron Annihilation Study of RPV Steels Radiation Loaded by Hydrogen Ion Implantation
Specimens of 15Kh2MFAA steel used for reactor pressure vessels V-213 (VVER-440 reactor) were studied by positron annihilation techniques in terms of their radiation resistance and structural recovery after thermal treatment. The radiation load was simulated by experimental implantation of 500 keV H+ ions. The maximum radiation damage of 1 DPA was obtained across a region of 3 µm. Radiation-induced defects were investigated by coincidence Doppler broadening spectroscopy and positron lifetime spectroscopy using a conventional positron source as well as a slow positron beam. All techniques registered an accumulation of small open-volume defects (mostly mono- and di-vacancies) due to the irradiation, with an increase of the defect volume ΔVD ≈ 2.88 × 10−8 cm−3. Finally, the irradiated specimens were gradually annealed at temperatures from 200 to 550 °C and analyzed in detail. The best defect recovery was found at a temperature between 450 and 475 °C, but the final defect concentration of about ΔCD = 0.34 ppm was still higher than in the as-received specimens.
- Open Access
On the Limitations of Positron Annihilation Spectroscopy in the Investigation of Ion-Implanted FeCr Samples
New materials for advanced fission/fusion nuclear facilities must inevitably demonstrate resistance to radiation embrittlement. Thermal and radiation ageing accompanied by stress corrosion cracking are dominant effects that limit the operational condition and safe lifetime of the newest nuclear facilities. To study these phenomena and improve the current understanding of various aspects of radiation embrittlement, ion bombardment experiments are widely used as a surrogate for neutron irradiation. While avoiding the induced activity, typical for neutron-irradiated samples, is a clear benefit of the ion implantation, the shallow near-surface region of the modified materials may be a complication to the post-irradiation examination (PIE). However, microstructural defects induced by ion implantation can be effectively investigated using various spectroscopic techniques, including slow-positron beam spectroscopy. This method, typically represented by techniques of positron annihilation lifetime spectroscopy and Doppler broadening spectroscopy, enables a unique depth-profile characterisation of the near-surface region affected by ion bombardment or corrosion degradation. One of the best slow-positron beam facilities is available at the pulsed low-energy positron system (PLEPS), operated at FRM-II reactor in Munich (Germany). Bulk studies (such as high energy ion implantation or neutron irradiation experiments) can be, on the other hand, effectively performed using radioisotope positron sources. In this paper, we outline some basics of the two approaches and provide some recommendations to improve the validity of the positron annihilation spectroscopy (PAS) data obtained on ion-irradiated samples using a conventional 22Na positron source.
Open AccessOn the Limitations of Positron Annihilation Spectroscopy in the Investigation of Ion-Implanted FeCr Samples
New materials for advanced fission/fusion nuclear facilities must inevitably demonstrate resistance to radiation embrittlement. Thermal and radiation ageing accompanied by stress corrosion cracking are dominant effects that limit the operational condition and safe lifetime of the newest nuclear facilities. To study these phenomena and improve the current understanding of various aspects of radiation embrittlement, ion bombardment experiments are widely used as a surrogate for neutron irradiation. While avoiding the induced activity, typical for neutron-irradiated samples, is a clear benefit of the ion implantation, the shallow near-surface region of the modified materials may be a complication to the post-irradiation examination (PIE). However, microstructural defects induced by ion implantation can be effectively investigated using various spectroscopic techniques, including slow-positron beam spectroscopy. This method, typically represented by techniques of positron annihilation lifetime spectroscopy and Doppler broadening spectroscopy, enables a unique depth-profile characterisation of the near-surface region affected by ion bombardment or corrosion degradation. One of the best slow-positron beam facilities is available at the pulsed low-energy positron system (PLEPS), operated at FRM-II reactor in Munich (Germany). Bulk studies (such as high energy ion implantation or neutron irradiation experiments) can be, on the other hand, effectively performed using radioisotope positron sources. In this paper, we outline some basics of the two approaches and provide some recommendations to improve the validity of the positron annihilation spectroscopy (PAS) data obtained on ion-irradiated samples using a conventional 22Na positron source.
- Open Access
Application of Positron Annihilation Spectroscopy in Accelerator-Based Irradiation Experiments
Positron annihilation spectroscopy (PAS) is widely recognized as a powerful characterization technique in all types of radiation damage studies in nuclear materials. In the past, fission reactor irradiation of reactor pressure vessel (RPV) steels was a primary aim in most studies, while today’s applications of PAS in this field are centered around ion implantation experiments in advanced structural materials. These experiments use hydrogen, helium, heavy ions, and their combination to simulate various radiation environments of future nuclear reactors or nuclear research facilities. The spectrum of ion energies used ranges from a few tens of keV to tens or even hundreds of MeV in proton irradiation or spallation neutron source irradiation experiments. The variety of ion energies, irradiation temperatures, and other experimental conditions poses a major challenge to researchers, who often fail to successfully incorporate the lessons learned from their research. In this paper, we review and supplement recent PAS studies in which structural materials irradiated under a variety of irradiation conditions were investigated using positron annihilation spectroscopy. It summarizes the most important conclusions and lessons learned from the application of PAS in accelerator-based irradiation experiments.
Open AccessApplication of Positron Annihilation Spectroscopy in Accelerator-Based Irradiation Experiments
Positron annihilation spectroscopy (PAS) is widely recognized as a powerful characterization technique in all types of radiation damage studies in nuclear materials. In the past, fission reactor irradiation of reactor pressure vessel (RPV) steels was a primary aim in most studies, while today’s applications of PAS in this field are centered around ion implantation experiments in advanced structural materials. These experiments use hydrogen, helium, heavy ions, and their combination to simulate various radiation environments of future nuclear reactors or nuclear research facilities. The spectrum of ion energies used ranges from a few tens of keV to tens or even hundreds of MeV in proton irradiation or spallation neutron source irradiation experiments. The variety of ion energies, irradiation temperatures, and other experimental conditions poses a major challenge to researchers, who often fail to successfully incorporate the lessons learned from their research. In this paper, we review and supplement recent PAS studies in which structural materials irradiated under a variety of irradiation conditions were investigated using positron annihilation spectroscopy. It summarizes the most important conclusions and lessons learned from the application of PAS in accelerator-based irradiation experiments.
- Open Access
Radiation Damage of Reactor Pressure Vessel Steels Studied by Positron Annihilation Spectroscopy—A Review
Safe and long term operation of nuclear reactors is one of the most discussed challenges in nuclear power engineering. The radiation degradation of nuclear design materials limits the operational lifetime of all nuclear installations or at least decreases its safety margin. This paper is a review of experimental PALS/PLEPS studies of different nuclear reactor pressure vessel (RPV) steels investigated over last twenty years in our laboratories. Positron annihilation lifetime spectroscopy (PALS) via its characteristics (lifetimes of positrons and their intensities) provides useful information about type and density of radiation induced defects. The new results obtained on neutron-irradiated and hydrogen ions implanted German steels were compared to those from the previous studies with the aim to evaluate different processes (neutron flux/fluence, thermal treatment or content of selected alloying elements) to the microstructural changes of neutron irradiated RPV steel specimens. The possibility of substitution of neutron treatment (connected to new defects creation) via hydrogen ions implantation was analyzed as well. The same materials exposed to comparable displacement damage (dpa) introduced by neutrons and accelerated hydrogen ions shown that in the results interpretation the effect of hydrogen as a vacancy-stabilizing gas must be considered, too. This approach could contribute to future studies of nuclear fission/fusion design steels treated by high levels of neutron irradiation.
Open AccessRadiation Damage of Reactor Pressure Vessel Steels Studied by Positron Annihilation Spectroscopy—A Review
Safe and long term operation of nuclear reactors is one of the most discussed challenges in nuclear power engineering. The radiation degradation of nuclear design materials limits the operational lifetime of all nuclear installations or at least decreases its safety margin. This paper is a review of experimental PALS/PLEPS studies of different nuclear reactor pressure vessel (RPV) steels investigated over last twenty years in our laboratories. Positron annihilation lifetime spectroscopy (PALS) via its characteristics (lifetimes of positrons and their intensities) provides useful information about type and density of radiation induced defects. The new results obtained on neutron-irradiated and hydrogen ions implanted German steels were compared to those from the previous studies with the aim to evaluate different processes (neutron flux/fluence, thermal treatment or content of selected alloying elements) to the microstructural changes of neutron irradiated RPV steel specimens. The possibility of substitution of neutron treatment (connected to new defects creation) via hydrogen ions implantation was analyzed as well. The same materials exposed to comparable displacement damage (dpa) introduced by neutrons and accelerated hydrogen ions shown that in the results interpretation the effect of hydrogen as a vacancy-stabilizing gas must be considered, too. This approach could contribute to future studies of nuclear fission/fusion design steels treated by high levels of neutron irradiation.
- 1 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1996 (1) , 020040
Performance of LYSO and BC420 coupled with Ketek and Sensl SiPM for needs of PALS
Material research of structural steels used in extreme conditions is important for the safe and reliable operation of individual components of nuclear installations. One of the effective methods of examining their microstructure is positron annihilation lifetime spectroscopy (PALS). For the needs of PALS, new types of detectors are currently being used compared to conventional photomultipliers. These types of detectors, however, are not sensitive to fast ultraviolent component of emission spectrum of the most commonly used scintillation material in this area - barium fluoride. This paper analyses the effect of the usage of LYSO and plastic scintillators on the properties of the spectrometric apparatus. These scintillation materials were linked to the SiPM detectors Sensl MicroFJ-SMA-30035 and Ketek PE6650-EB-AX as well as to the conventional Photonis XP2020Q photomultiplier.
- 1 August 2018
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1996 (1) , 020040
Performance of LYSO and BC420 coupled with Ketek and Sensl SiPM for needs of PALS
Material research of structural steels used in extreme conditions is important for the safe and reliable operation of individual components of nuclear installations. One of the effective methods of examining their microstructure is positron annihilation lifetime spectroscopy (PALS). For the needs of PALS, new types of detectors are currently being used compared to conventional photomultipliers. These types of detectors, however, are not sensitive to fast ultraviolent component of emission spectrum of the most commonly used scintillation material in this area - barium fluoride. This paper analyses the effect of the usage of LYSO and plastic scintillators on the properties of the spectrometric apparatus. These scintillation materials were linked to the SiPM detectors Sensl MicroFJ-SMA-30035 and Ketek PE6650-EB-AX as well as to the conventional Photonis XP2020Q photomultiplier.
- 8 October 2009
- Published by Wiley in physica status solidi (c)
- Vol. 6 (11) , 2465-2467
Application of fast‐digitizer card Acqiris DP‐240 in positron lifetime spectroscopy
Based on the available knowledge base in positron annihilation measurements, new software for digital positron lifetime spectrometry has been designed within the frame of joint activity between STU Bratislava and JRC Petten. The tests of the new positron digital‐life time setup have been carried out. Detectors with BaF2 scintillators and fast‐dynode outputs were chosen for such studies. As the digitiser unit, the card Acqiris DP240 was fully tested. Originally, start and stop timing signals were sampled to digital waveforms separately at a rate of 1 GS/s in 8 bit resolution. However, due to limited quality of collected waveforms which significantly affected post‐processing of data, the joined delayed channel mode with 2 GS/s sampling rate was applied for further studies. The full setup was benchmarked by a series of calibration measurements of two high purity materials, specifically Si and Ni. The inter‐comparison of conventional analogue‐ and digital‐based processing are discussed in detail. Further, the optimisation of main parameters for waveform‐processing are analysed too. Such a new approach in the digital life‐time spectroscopy will help to improve the resolution of existing methodology which might enhance the capabilities of this technique for further applications, especially in materials science.
- 8 October 2009
- Published by Wiley in physica status solidi (c)
- Vol. 6 (11) , 2465-2467
Application of fast‐digitizer card Acqiris DP‐240 in positron lifetime spectroscopy
Based on the available knowledge base in positron annihilation measurements, new software for digital positron lifetime spectrometry has been designed within the frame of joint activity between STU Bratislava and JRC Petten. The tests of the new positron digital‐life time setup have been carried out. Detectors with BaF2 scintillators and fast‐dynode outputs were chosen for such studies. As the digitiser unit, the card Acqiris DP240 was fully tested. Originally, start and stop timing signals were sampled to digital waveforms separately at a rate of 1 GS/s in 8 bit resolution. However, due to limited quality of collected waveforms which significantly affected post‐processing of data, the joined delayed channel mode with 2 GS/s sampling rate was applied for further studies. The full setup was benchmarked by a series of calibration measurements of two high purity materials, specifically Si and Ni. The inter‐comparison of conventional analogue‐ and digital‐based processing are discussed in detail. Further, the optimisation of main parameters for waveform‐processing are analysed too. Such a new approach in the digital life‐time spectroscopy will help to improve the resolution of existing methodology which might enhance the capabilities of this technique for further applications, especially in materials science.