AKAsim Kurjak

Asim Kurjak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Asim Kurjak has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Scientific and religious controversies about the beginning of human life: the relevance of the ethical concept of the fetus as a patient

    by Asim Kurjak, Jose Maria Carrera, Laurence B. McCullough, Frank A. Chervenak

    In this paper we show that the question, "When does human life begin?", is not one question, but three. The first question is, "When does human biological life begin?", and is a scientific question. A brief review of embryology is provided to answer this question. The second question is, "When do obligations to protect human life begin?", and is a question of general theological and philosophical ethics. A brief review of major world religions and philosophy is provided to answer this question but has no settled answer and therefore involves irresolvable controversy. The third question is, "How should physicians respond to disagreement about when obligations to protect human life begin?" and is a question for professional medical ethics. A review of the ethical concept of the fetus as a patient is provided to answer this question. Physicians should manage the irresolvable controversy surrounding the second question by appealing to the ethical concept of the fetus as a patient. It is philosophically sound, respectful of all religious traditions and the personal convictions of patients and physicians alike, and clinically applicable.


  • Structural and functional early human development assessed by three-dimensional and four-dimensional sonography

    by Asim Kurjak, Ritsuko K. Pooh, Luis T. Merce, Jose M. Carrera, Aida Salihagic-Kadic, Wiku Andonotopo


    • 1 October 2005
      • Vol. 46  (5) , 757-64

    Three-dimensional ultrasonography and power Doppler in ovarian cancer screening of asymptomatic peri- and postmenopausal women.

    by Asim Kurjak, Matija Prka, Jose Manuel Bajo Arenas, Vladimir Sparac, Luis Tadeo Merce, Ante Corusic, Mirjana Ivancic-Kosuta

    To determine whether introducing three-dimensional (3D) ultrasonography with power Doppler facilities as a secondary screening test, preceded by annual transvaginal grayscale ultrasonography (TVUS) (followed by transvaginal color Doppler (TVCD) in selected cases) as a primary screening test for ovarian cancer improves the accuracy of ovarian cancer screening studies. Annual TVUS was performed on 3,201 peri- and postmenopausal asymptomatic women aged > or =50 years from March 1, 2001 to June 30, 2003. Cystic ovarian lesions in perimenopausal women were routinely reevaluated by TVUS and TVCD at 4-6 week intervals to avoid unnecessary surgical intervention for physiological cysts. Any multiloculated, complex or solid ovarian mass, as well as persistently cystic mass >5 cm in diameter, in which the echo architecture and/or blood flow pattern was not highly suggestive of a benign histology, was categorized malignant. In these cases, TVUS and TVCD findings were obtained in no more than 2 weeks and supplemented by secondary screening, including 3D ultrasonography, and 3D power Doppler, in combination with serum CA 125 determination. After detailed ultrasonographic examination, surgical removal of the tumor and pathohistological classification were completed. Twenty-five patients (0.8%) with persisting ultrasonographic abnormalities after primary and secondary screening underwent surgery to remove the ovarian tumor. Five epithelial ovarian cancers were detected: 3 stage IA, 1 stage IB, and 1 stage IC. Three stage I patients had a palpable abnormality on clinical examination. Furthermore, in three patients with stage I disease, CA 125 serum value was elevated (> or =35 U/mL). Three-dimensional ultrasonography and power Doppler, as well as TVUS findings were indicative of malignancy in all 5 patients with stage I ovarian cancer, whereas TVCD finding was false-negative in 2 patients with stage I disease. Screening test (primary+secondary screening) had the sensitivity of 100%, specificity of 99.4%, positive predictive value of 20%, and negative predictive value of 100%. Application of 3D ultrasonography and power Doppler imaging in patients with "positive" standard ultrasound tests (annual TVUS, followed by TVCD in selected cases) represents a novel approach for the early and accurate detection of ovarian cancer through screening.


    • 1 October 2005
      • Vol. 46  (5) , 772-80

    Fetal behavior assessed in all three trimesters of normal pregnancy by four-dimensional ultrasonography.

    by Asim Kurjak, Milan Stanojevic, Wiku Andonotopo, Elena Scazzocchio-Duenas, Guillermo Azumendi, Jose Maria Carrera

    To assess fetal behavior in all three trimesters of normal pregnancy and to investigate the continuation of behavior from fetal to neonatal period. One hundred out of 130 pregnant women in all trimesters with singleton pregnancy were assigned for the investigation. All recordings were performed in the morning, after two hours of fasting. Video recordings of newborns were made while the newborns were in bed, separated from other infants in the nursery, dressed, and lying on their backs in a supine position with unrestrained hands. Recording was not performed during prolonged episodes of fussing and crying, during drowsiness, and episodes of hiccupping. All observed facial expressions and movement patterns were presented collectively with maximum, minimum, and median frequencies during 30-minute observation period. We noted a tendency towards decreased frequency of facial expressions and movement patterns with increasing gestational age. In the first trimester, we observed the highest incidence of general movements ranging between 5 and 147, and with a median value of 47. In the second trimester, the number of head and hand movements decreased gradually, compared with the first trimester. The highest range was registered for head retroflexion pattern, ranging from 15 to 42 with a median of 25. The most frequent facial pattern in the second trimester was sucking (3 and 30 movements per infant with a median value of 9). Wilcoxon rank-sum test showed statistically significant differences between the fetuses in the third trimester and the newborns (P<0.05) in hand to head, hand to mouth, hand to eye, hand to ear movement), tongue expulsion, and smiling, whereas the differences between the rest of the movements were not statistically significant. Spearman rank order correlation reached statistical significance (P<0.05) in isolated eye blinking, smiling, grimacing, hand to head, hand to mouth, hand to eye, hand to face, and in hand to ear movement, whereas the differences between the rest of the facial expressions were not statistically significant. Fetal behavioral patterns directly reflect the developmental and maturational processes of the central nervous system. 4D observation of fetal and early neonatal period may add to better understanding of the neurological development of the fetus.


  • The antenatal development of fetal behavioral patterns assessed by four-dimensional sonography

    by A Kurjak, Jm Carrera, M Medic, G Azumendi, W Andonotopo, M Stanojevic

    The investigation of fetal intrauterine activities has been enabled by the development of two-dimensional ultrasound. It has been shown that the earliest signs of fetal motor activity can be in the late embryonic period, and that the characteristics of fetal motor patterns change constantly throughout gestation. During the first trimester of pregnancy, the repertoire and frequency fetal movement patterns constantly expand, whereas the second and third trimesters are characterized by the progressive organization of fetal activities into complex and clearly distinct behavioral patterns. The comparison of real time ultrasonic studies of fetal behavior with the morphological studies of fetal brains has revealed that the appearance of new behavioral patterns or the transition of existing patterns directly reflect the complex neurodevelopment processes. It has been suggested that the assessment of fetal behavioral patterns could give us insight into the integrity of fetal central nervous system and enable the early detection of cerebral dysfunctions. The development of a new ultrasonic technique, four dimensional sonography, could represent a significant improvement in the assessment of fetal behavior. According to the preliminary results, this new technique could open a new perspective for the investigations of fetal behavioral patterns and contribute significantly to our better understanding of complex neurodevelopmental events. The most important neurodevelopmental events, the basic technology of 4D ultrasound and its application in the assessment of functional development of fetal central nervous system will be the subject of this review.


  • The potential of four-dimensional (4D) ultrasonography in the assessment of fetal awareness

    by Asim Kurjak, Milan Stanojevic, Guillermo Azumendi, José M. Carrera

    Aim : The aim of the study was to observe different expressions and movements of a fetal face during investigation of fetal behavior in the second and the third trimester of normal pregnancies, as a probable manifestation of fetal awareness. Subjects and methods : Over a 6-month period a study was conducted in three centers in Zagreb, Croatia and in Barcelona and Malaga, Spain. Women with singleton pregnancies (16–33 weeks) who were referred for ultrasound check-up for determination of gestational age, suspicious fetal malformations, polyhydramnios, and/or the assessment of biophysical profile or other possible pathology, were assigned to the study. After regular two-dimensional (2D) ultrasound assessment at an antenatal clinic, pregnant women were offered the possibility of undergoing 4D ultrasound examination if the fetus and the mother were considered “normal”, i.e., if ultrasound and clinical assessment were uneventful. If the newborn delivered at term had 1- and 5-min Apgar scores of 7 and 10, respectively, and if the newborn was considered “term and normal” (normal spontaneous activity, normal posture and tone, and presence of some primitive reflexes) at the first and subsequent regular check-ups, the inclusion criteria were deemed to have been met. Out of 119 patients, 99 fulfilled the inclusion criteria, 40 of whom were in the second, and 59 in the third trimester of pregnancy. A Voluson 730 Expert system with a transabdominal 5-MHz transducer was used for 4D ultra- sonography. After regular 2D scanning, the 4D mode was switched on, and a live 3D image was reconstructed by selecting ideal 2D mid-sagittal images of the face (the region of interest). The volume was automatically scanned every 2 s while the surface-rendered mode was switched on, and 4D images were displayed on the screen and recorded on videotape during a 30-min observation period. Movements of the following fetal face structures were analyzed: forehead, brows, nasal soft tissue and nasolabial folds, upper lip, oral cavity and tongue, lower lip and chin, eyelids and eyes, mouth and mouth angles, and facial expression. 4D ultrasonography allowed in utero observations of fetal facial expressions such as smiling, yawning, and swallowing. Results : The quality of 4D depiction of fetal facial expressions increased with gestational age. The frequency of fetal facial expressions such as yawning ranged from 1 and 6 with a median of 1.5 per 30-min observation period; smiling ranged from 2 and 8 with the median of 2; tongue expulsion ranged from 2 to 6, median 3; mouth and eye squeezing ranged from 5 to 10, median 6; scowling ranged from 1 to 3, median 0.5; and isolated eye blinking ranged from 4 to 12 with a median of 5. Conclusions : Our study shows the ability of 4D sonography to depict different facial expressions and movements, which might represent fetal awareness. Never-theless, long, precise and thorough observation of fetal faces by 4D sonography was hampered as the images were only near real-time. Thus, we were only able to study the quality and not the quantity of facial movement patterns.


    • 1 December 2003
      • Vol. 44  (6) , 734-9

    Monochorionic twin pregnancy: retrospective analysis of predicted pregnancy outcome.

    by Ratko Matijević, Meliha Solak, Nika Kalogjera, Asim Kurjak

    To assess the accurate establishment of chorionicity, perinatal complications, and outcome of monochorionic twin pregnancies managed in a tertiary referral center in Croatia and compare the findings with data published for other countries. The retrospective analysis included data on a total of 24 monochorionic twin pregnancies delivered at the Department between January 1998 and May 2002. The data retrieved from the maternity ward birth register included the ultrasound establishment of chorionicity, demographic data, complications of the pregnancy (presence of twin-to-twin-transfusion syndrome, intrauterine growth restriction, and threatened or actual preterm labor rate), and pregnancy outcome. Perinatal morbidity and mortality were also analyzed. The establishment of chorionicity by ultrasound was accurate in all 24 monochorionic twin pregnancies. Five twins died in the perinatal period, and two in early neonatal period. The median gestational age at delivery was 35 weeks, ranging 29 to 38 weeks, and median birth weight was 1,990 g, ranging from 740 to 3,000 g. Intrauterine growth restriction was present in 18 cases, whereas twin-to-twin-transfusion syndrome complicated 2 monochorionic twin pregnancies. Symptoms of threatened preterm labor were present in 19 women, whereas actual preterm delivery rate was 16 out of 24. The diagnosis of monochorionic twin pregnancy can be reliably made by ultrasound. Monochorionic twin pregnancies are characterized by a high complication rate, with threatened and actual preterm labor and delivery as the most common complications. These pregnancies are also accompanied with high perinatal mortality and morbidity.


  • The detection of stage I ovarian cancer by three-dimensional sonography and power Doppler

    by Asim Kurjak, Sanja Kupesic, Vladimir Sparac, Matija Prka, Ivanka Bekavac