L. Pruitt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
L. Pruitt has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
C. Li
Department of Bioengineering, University of California, Berkeley, California 94720, USA
1 shared publicationC. Xu
Department of Surgery, Stanford University, Palo Alto, California 94305
1 shared publication- Catherine M. Klapperich
Department of Biomedical Engineering
1 shared publication D. Saloner
Department of Radiology, University of California, San Francisco, California 94143
1 shared publication- Donna M. Ebenstein
Bucknell University
1 shared publication J. Chapman
Department of Bioengineering, University of California, Berkeley, California 94720
1 shared publication
Latest Publications
- 7 March 2003
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 65A (2) , 126-135
Structural degradation of acrylic bone cements due to in vivo and simulated aging
Acrylic bone cement is the primary load‐bearing material used for the attachment of orthopedic devices to adjoining bone. Degradation of acrylic‐based cements in vivo results in a loss of structural integrity of the bone‐cement‐prosthesis interface and limits the longevity of cemented orthopedic implants. The purpose of this study is to investigate the effect of in vivo aging on the structure of the acrylic bone cement and to develop an in vitro artificial aging protocol that mimics the observed degradation. Three sets of retrievals are examined in this study: Palacos® brand cement retrieved from hip replacements, and Simplex® brand cement retrieved from both hip and knee replacement surgeries. In vitro aging is performed using oxidative and acidic environments on three acrylic‐based cements: Palacos®, Simplex®, and CORE®. Gel permeation chromatography (GPC) and Fourier transform infrared spectroscopy (FTIR) are used to examine the evolution of molecular weight and chemical species within the acrylic cements due to both in vivo and simulated aging. GPC analysis indicates that molecular weight is degraded in the hip retrievals but not in the knee retrievals. Artificial aging in an oxidative environment best reproduces this degradation mechanism. FTIR analysis indicates that there exists a chemical evolution within the cement due to in vivo and in vitro aging. These findings are consistent with scission‐based degradation schemes in the cement. Based on the results of this study, a pathway for structural degradation of acrylic bone cement is proposed. The findings from this investigation have broad applicability to acrylic‐based cements and may provide guidance for the development of new bone cements that resist degradation in the body. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 126–135, 2003
- 7 March 2003
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 65A (2) , 126-135
Structural degradation of acrylic bone cements due to in vivo and simulated aging
Acrylic bone cement is the primary load‐bearing material used for the attachment of orthopedic devices to adjoining bone. Degradation of acrylic‐based cements in vivo results in a loss of structural integrity of the bone‐cement‐prosthesis interface and limits the longevity of cemented orthopedic implants. The purpose of this study is to investigate the effect of in vivo aging on the structure of the acrylic bone cement and to develop an in vitro artificial aging protocol that mimics the observed degradation. Three sets of retrievals are examined in this study: Palacos® brand cement retrieved from hip replacements, and Simplex® brand cement retrieved from both hip and knee replacement surgeries. In vitro aging is performed using oxidative and acidic environments on three acrylic‐based cements: Palacos®, Simplex®, and CORE®. Gel permeation chromatography (GPC) and Fourier transform infrared spectroscopy (FTIR) are used to examine the evolution of molecular weight and chemical species within the acrylic cements due to both in vivo and simulated aging. GPC analysis indicates that molecular weight is degraded in the hip retrievals but not in the knee retrievals. Artificial aging in an oxidative environment best reproduces this degradation mechanism. FTIR analysis indicates that there exists a chemical evolution within the cement due to in vivo and in vitro aging. These findings are consistent with scission‐based degradation schemes in the cement. Based on the results of this study, a pathway for structural degradation of acrylic bone cement is proposed. The findings from this investigation have broad applicability to acrylic‐based cements and may provide guidance for the development of new bone cements that resist degradation in the body. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 65A: 126–135, 2003
- 20 December 2002
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 64A (2) , 197-206
Biochemical characterization of atherosclerotic plaque constituents using FTIR spectroscopy and histology
- 20 December 2002
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 64A (2) , 197-206
Biochemical characterization of atherosclerotic plaque constituents using FTIR spectroscopy and histology
- 23 April 2001
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 56 (2) , 245-249
Comparison of three joint simulator wear debris isolation techniques: Acid digestion, base digestion, and enzyme cleavage
Quantification of ultrahigh molecular weight polyethylene (UHMWPE) wear debris remains a challenging task in orthopedic device analysis. Currently, the weight loss method is the only accepted practice for quantifying the amount of wear generated from a PE component. This technique utilizes loaded soak controls and weight differences to account for polymeric material lost through wear mechanisms. This method enables the determination of the amount of wear in the orthopedic device, but it provides no information about debris particulate size distribution. In order to shed light on wear mechanisms, information about the wear debris and its size distribution is necessary. To date, particulate isolation has been performed using the base digestion technique. The method uses a strong base, ultracentrifugation, and filtration to digest serum constituents and to isolate PE debris from sera. It should be noted that particulate isolation methods provide valuable information about particulate size distribution and may elucidate the mechanisms of wear associated with polymeric orthopedic implants; however, these techniques do not yet provide a direct measure of the amount of wear. The aim of this study is to present alternative approaches to wear particle isolation for analysis of polymer wear in total joint replacements without recourse to ultracentrifugation. Three polymer wear debris isolation techniques (the base method, an acid treatment, and an enzymatic digestion technique) are compared for effectiveness in simulator studies. A requirement of each technique is that the wear particulate must be completely devoid of serum proteins in order to effectively image and count these particles. In all methods the isolation is performed through filtration and chemical treatment. Subsequently, the isolated polymer particles are imaged using scanning electron microscopy and quantified with digital image analysis. The results from this study clearly show that isolation can be performed without the use of ultracentrifugation and that these methods provide a viable option for wear debris analysis. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 56: 245–249, 2001
- 23 April 2001
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 56 (2) , 245-249
Comparison of three joint simulator wear debris isolation techniques: Acid digestion, base digestion, and enzyme cleavage
Quantification of ultrahigh molecular weight polyethylene (UHMWPE) wear debris remains a challenging task in orthopedic device analysis. Currently, the weight loss method is the only accepted practice for quantifying the amount of wear generated from a PE component. This technique utilizes loaded soak controls and weight differences to account for polymeric material lost through wear mechanisms. This method enables the determination of the amount of wear in the orthopedic device, but it provides no information about debris particulate size distribution. In order to shed light on wear mechanisms, information about the wear debris and its size distribution is necessary. To date, particulate isolation has been performed using the base digestion technique. The method uses a strong base, ultracentrifugation, and filtration to digest serum constituents and to isolate PE debris from sera. It should be noted that particulate isolation methods provide valuable information about particulate size distribution and may elucidate the mechanisms of wear associated with polymeric orthopedic implants; however, these techniques do not yet provide a direct measure of the amount of wear. The aim of this study is to present alternative approaches to wear particle isolation for analysis of polymer wear in total joint replacements without recourse to ultracentrifugation. Three polymer wear debris isolation techniques (the base method, an acid treatment, and an enzymatic digestion technique) are compared for effectiveness in simulator studies. A requirement of each technique is that the wear particulate must be completely devoid of serum proteins in order to effectively image and count these particles. In all methods the isolation is performed through filtration and chemical treatment. Subsequently, the isolated polymer particles are imaged using scanning electron microscopy and quantified with digital image analysis. The results from this study clearly show that isolation can be performed without the use of ultracentrifugation and that these methods provide a viable option for wear debris analysis. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 56: 245–249, 2001