Marco Degidi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Marco Degidi has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Piattelli
School of Dentistry, UniCamillus-Saint Camillus International University of Health and Medical Sciences, 00131 Rome, Italy
25 shared publications - Giovanna Iezzi
Department of Medical, Oral and Biotechnological Sciences, University G. d’Annunzio of Chieti-Pescara, 66100 Chieti, Italy
12 shared publications - Vittoria Perrotti
Department of Innovative Technologies in Medicine and Dentistry, University “G. d’Annunzio” of Chieti-Pescara, Chieti, Italy
9 shared publications - Diego Nardi
Private Practice, Bologna, Italy
5 shared publications - Antonio Scarano
Department of Innovative Technologies in Medicine and Dentistry, University of Chieti-Pescara, 66100 Chieti, Italy
4 shared publications Francesco Carinci
University of Ferrara, Italy
4 shared publications
Latest Publications
- 8 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29, 346
A nine-year follow-up of full-arch immediate long-term restorations fabricated with the electric resistance welding technique
- 8 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29, 346
A nine-year follow-up of full-arch immediate long-term restorations fabricated with the electric resistance welding technique
- 13 January 2017
- Published by Bentham Science Publishers Ltd. in Current Pharmaceutical Biotechnology
- Vol. 18 (1) , 33-44
Molecular, Cellular and Pharmaceutical Aspects of Bone Grafting Materials and Membranes During Maxillary Sinus-lift Procedures. Part 2: Detailed Characteristics of the Materials
Various grafts or combination of bone substitute materials have been used in sinus lift procedures. Currently, ongoing developments in several disciplines, from molecular biology and chemistry to computer science and engineering, have contributed to the understanding of biological processes leading to bone healing after the use of bone substitute materials (BSBs) and therefore of the behavior of BSBs. The understanding of the properties of each graft enables individual treatment concepts and therefore allows shift from a simple replacement material to the modern concept of an individually created composite biomaterial. Indeed, the choice of the best BSB still remains crucial for success in maxillary sinus augmentation procedures. The present article provides an overview of most of the materials currently available for sinus lift, with a specific focus on their histological, molecular, cellular and pharmaceutical aspects.
- 13 January 2017
- Published by Bentham Science Publishers Ltd. in Current Pharmaceutical Biotechnology
- Vol. 18 (1) , 33-44
Molecular, Cellular and Pharmaceutical Aspects of Bone Grafting Materials and Membranes During Maxillary Sinus-lift Procedures. Part 2: Detailed Characteristics of the Materials
Various grafts or combination of bone substitute materials have been used in sinus lift procedures. Currently, ongoing developments in several disciplines, from molecular biology and chemistry to computer science and engineering, have contributed to the understanding of biological processes leading to bone healing after the use of bone substitute materials (BSBs) and therefore of the behavior of BSBs. The understanding of the properties of each graft enables individual treatment concepts and therefore allows shift from a simple replacement material to the modern concept of an individually created composite biomaterial. Indeed, the choice of the best BSB still remains crucial for success in maxillary sinus augmentation procedures. The present article provides an overview of most of the materials currently available for sinus lift, with a specific focus on their histological, molecular, cellular and pharmaceutical aspects.
- 1 December 2012
- Vol. 32 (6) , e189-94
Immediate rehabilitation of the edentulous mandible using Ankylos SynCone telescopic copings and intraoral welding: a pilot study.
The aim of this prospective study was to assess the suitability of immediate rehabilitation of the edentulous mandible using SynCone copings and the intraoral welding technique. Patients with an edentulous mandible were fitted with a removable restoration supported by an intraorally welded titanium bar. Copings were connected to their respective SynCone 5-degree abutments and then welded to a titanium bar using an intraoral welding unit. This framework was used to support the definitive restoration, which was delivered on the day of implant placement. Restoration success and survival, implant success, and biologic or technical complications were assessed immediately after surgery and at 6 and 12 months. Twenty-two patients were consecutively treated with 88 immediately loaded implants. No acrylic resin fractures or radiographically detectable alterations of the welded frameworks were present in the 22 restorations delivered. One implant (1.1%) failed 1 month after surgery; all remaining implants (98.9%) were clinically stable at the 12-month follow-up. Within its limitations, this pilot study demonstrated that it is possible to successfully rehabilitate the edentulous mandible on the day of surgery with a definitive restoration supported by an intraorally welded titanium framework and SynCone 5-degree abutments.
- 1 December 2012
- Vol. 32 (6) , e189-94
Immediate rehabilitation of the edentulous mandible using Ankylos SynCone telescopic copings and intraoral welding: a pilot study.
The aim of this prospective study was to assess the suitability of immediate rehabilitation of the edentulous mandible using SynCone copings and the intraoral welding technique. Patients with an edentulous mandible were fitted with a removable restoration supported by an intraorally welded titanium bar. Copings were connected to their respective SynCone 5-degree abutments and then welded to a titanium bar using an intraoral welding unit. This framework was used to support the definitive restoration, which was delivered on the day of implant placement. Restoration success and survival, implant success, and biologic or technical complications were assessed immediately after surgery and at 6 and 12 months. Twenty-two patients were consecutively treated with 88 immediately loaded implants. No acrylic resin fractures or radiographically detectable alterations of the welded frameworks were present in the 22 restorations delivered. One implant (1.1%) failed 1 month after surgery; all remaining implants (98.9%) were clinically stable at the 12-month follow-up. Within its limitations, this pilot study demonstrated that it is possible to successfully rehabilitate the edentulous mandible on the day of surgery with a definitive restoration supported by an intraorally welded titanium framework and SynCone 5-degree abutments.
- 1 October 2012
- Vol. 32 (5) , e154-61
Immediate loading of zygomatic implants using the intraoral welding technique: a 12-month case series.
The aim of this prospective study was to evaluate the concept of intraoral welding as a suitable technique for fabricating a fixed restoration for the edentulous maxilla the day of surgery using standard and zygomatic implants. Ten consecutive patients (four men, six women; mean age, 62.3 ± 11.6 years) were involved in this study, each of whom had an edentulous atrophic maxilla and received two standard and two zygomatic implants. All implants were loaded immediately with a fixed prosthesis supported by an intraorally welded titanium framework. Definitive abutments were connected to the implants, and a titanium bar was welded to them using an intraoral welding unit. This framework was used to support the definitive prosthesis, which was fitted the day of implant placement. Patients were checked for swelling, pain, and framework stability at 1, 3, 6, and 12 months. A total of 20 immediately loaded standard and 20 zygomatic implants were used. The cases included in this study achieved a 100% prosthetic success rate at the 12-month follow-up. No fracture or radiographically detectable alteration of the welded frameworks was noticed. It is possible to successfully rehabilitate the edentulous atrophic maxilla with a permanently fixed prosthesis supported by an intraorally welded titanium framework attached to standard and zygomatic implants the day of surgery.
- 1 October 2012
- Vol. 32 (5) , e154-61
Immediate loading of zygomatic implants using the intraoral welding technique: a 12-month case series.
The aim of this prospective study was to evaluate the concept of intraoral welding as a suitable technique for fabricating a fixed restoration for the edentulous maxilla the day of surgery using standard and zygomatic implants. Ten consecutive patients (four men, six women; mean age, 62.3 ± 11.6 years) were involved in this study, each of whom had an edentulous atrophic maxilla and received two standard and two zygomatic implants. All implants were loaded immediately with a fixed prosthesis supported by an intraorally welded titanium framework. Definitive abutments were connected to the implants, and a titanium bar was welded to them using an intraoral welding unit. This framework was used to support the definitive prosthesis, which was fitted the day of implant placement. Patients were checked for swelling, pain, and framework stability at 1, 3, 6, and 12 months. A total of 20 immediately loaded standard and 20 zygomatic implants were used. The cases included in this study achieved a 100% prosthetic success rate at the 12-month follow-up. No fracture or radiographically detectable alteration of the welded frameworks was noticed. It is possible to successfully rehabilitate the edentulous atrophic maxilla with a permanently fixed prosthesis supported by an intraorally welded titanium framework attached to standard and zygomatic implants the day of surgery.
- 1 August 2012
- Vol. 32 (4) , 451-7
Histologic and histomorphometric evaluation of an implant retrieved 8 years after insertion in a sinus augmented with anorganic bovine bone and anorganic bovine matrix associated with a cell-binding peptide: a case report.
Few histologic and histomorphometric reports are present in the literature regarding the peri-implant bone response around implants inserted in sinuses grafted with different biomaterials. Anorganic bovine bone (ABB) and anorganic bovine matrix with the addition of an active cell-binding peptide (PepGen P-15) are xenogenic materials that have been reported to present biocompatibility and osteoconductivity. A monolateral sinus augmentation procedure with ABB (50%) and PepGen P-15 (50%) was performed in a 54-year-old man. Two titanium implants with a sandblasted and acid-etched surface were inserted after 6 months. After an additional 6 months, a fixed prosthetic restoration was fabricated. One implant fractured in the coronal portion after an 8-year loading period and was removed using a 5-mm trephine bur. Few particles of both grafting materials were present in the peri-implant bone. No graft material particles were found in contact with the implant surface, and bone was always interposed between the graft materials and surface. No inflammatory cell infiltrate, multinucleated giant cells, or foreign body reaction cells were found. The tissues around the implant were composed of 51.4% ± 4.8% bone, 6.2% ± 0.7% ABB particles, 2.4% ± 0.5% PepGen P-15, and 40.0% ± 7.1% marrow spaces. The bone-implant contact percentage was 78.4% ± 4.1%. A sinus augmentation procedure using ABB and PepGen P-15 produced bone formation with subsequent implant osseointegration, which was still present after 8 years of implant loading.
- 1 August 2012
- Vol. 32 (4) , 451-7
Histologic and histomorphometric evaluation of an implant retrieved 8 years after insertion in a sinus augmented with anorganic bovine bone and anorganic bovine matrix associated with a cell-binding peptide: a case report.
Few histologic and histomorphometric reports are present in the literature regarding the peri-implant bone response around implants inserted in sinuses grafted with different biomaterials. Anorganic bovine bone (ABB) and anorganic bovine matrix with the addition of an active cell-binding peptide (PepGen P-15) are xenogenic materials that have been reported to present biocompatibility and osteoconductivity. A monolateral sinus augmentation procedure with ABB (50%) and PepGen P-15 (50%) was performed in a 54-year-old man. Two titanium implants with a sandblasted and acid-etched surface were inserted after 6 months. After an additional 6 months, a fixed prosthetic restoration was fabricated. One implant fractured in the coronal portion after an 8-year loading period and was removed using a 5-mm trephine bur. Few particles of both grafting materials were present in the peri-implant bone. No graft material particles were found in contact with the implant surface, and bone was always interposed between the graft materials and surface. No inflammatory cell infiltrate, multinucleated giant cells, or foreign body reaction cells were found. The tissues around the implant were composed of 51.4% ± 4.8% bone, 6.2% ± 0.7% ABB particles, 2.4% ± 0.5% PepGen P-15, and 40.0% ± 7.1% marrow spaces. The bone-implant contact percentage was 78.4% ± 4.1%. A sinus augmentation procedure using ABB and PepGen P-15 produced bone formation with subsequent implant osseointegration, which was still present after 8 years of implant loading.
- 1 June 2012
- Vol. 32 (3) , 323-8
Peri-implant collagen fibers around human cone Morse connection implants under polarized light: a report of three cases.
Most of the histologic studies found in the literature on the peri-implant soft tissues have been done in animals and usually have been confined to mandibular implants fitted with healing or standard abutments. Few studies have investigated human peri-implant soft tissues. Moreover, the structure and dimensions of the peri-implant soft tissues in immediately loaded implants have not been investigated in depth. Human histologic data are valuable to validate animal models. This histologic and histomorphometric study evaluated the peri-implant soft tissues around three immediately loaded implants in humans. The implants were retrieved using a trephine and treated to obtain thin, ground sections. The sulcular epithelium was composed of approximately four to five layers of parakeratinized epithelial cells and had a length of approximately 1.2 to 1.3 mm. The junctional epithelium was composed of approximately three to four layers of epithelial cells and had a length of approximately 1.0 to 1.5 mm. Connective tissue attachment had a width of between 400 and 800 μm. Peri-implant collagen fibers, in the form of bundles (1- to 5-μm thick), began at the crestal bone and were oriented perpendicular to the abutment surface until 200 μm from the surface, where they became parallel running in several directions. Collagen fibers appeared to form a three-dimensional network around the abutment. No acute or chronic inflammatory cell infiltrate was present. Collagen fibers oriented in a perpendicular manner and in direct contact with the abutment surface were not observed in any of the specimens. This differentiated network of fibers may have clinical relevance as a mechanical protection of the underlying bone. These human histologic data are extremely valuable to validate and confirm those obtained from studies performed on animal models. Moreover, immediate loading of the implants did not compromise soft tissue integration.
- 1 June 2012
- Vol. 32 (3) , 323-8
Peri-implant collagen fibers around human cone Morse connection implants under polarized light: a report of three cases.
Most of the histologic studies found in the literature on the peri-implant soft tissues have been done in animals and usually have been confined to mandibular implants fitted with healing or standard abutments. Few studies have investigated human peri-implant soft tissues. Moreover, the structure and dimensions of the peri-implant soft tissues in immediately loaded implants have not been investigated in depth. Human histologic data are valuable to validate animal models. This histologic and histomorphometric study evaluated the peri-implant soft tissues around three immediately loaded implants in humans. The implants were retrieved using a trephine and treated to obtain thin, ground sections. The sulcular epithelium was composed of approximately four to five layers of parakeratinized epithelial cells and had a length of approximately 1.2 to 1.3 mm. The junctional epithelium was composed of approximately three to four layers of epithelial cells and had a length of approximately 1.0 to 1.5 mm. Connective tissue attachment had a width of between 400 and 800 μm. Peri-implant collagen fibers, in the form of bundles (1- to 5-μm thick), began at the crestal bone and were oriented perpendicular to the abutment surface until 200 μm from the surface, where they became parallel running in several directions. Collagen fibers appeared to form a three-dimensional network around the abutment. No acute or chronic inflammatory cell infiltrate was present. Collagen fibers oriented in a perpendicular manner and in direct contact with the abutment surface were not observed in any of the specimens. This differentiated network of fibers may have clinical relevance as a mechanical protection of the underlying bone. These human histologic data are extremely valuable to validate and confirm those obtained from studies performed on animal models. Moreover, immediate loading of the implants did not compromise soft tissue integration.
- 24 March 2012
- Vol. 27 (2) , 336-40
Bone regeneration with algae-derived hydroxyapatite: a pilot histologic and histomorphometric study in rabbit tibia defects.
Algipore is a biologic hydroxyapatite derived from calcifying maritime algae. The present study evaluated this material histologically and histomorphometrically after implantation in rabbit tibia defects for 4 weeks. Six New Zealand rabbits were used in this study. In each rabbit tibia, two 7-mm defects were prepared. Control defects were left empty, and test defects were filled with Algipore. Twenty-four specimens (12 test and 12 control) were retrieved and processed for histology. In control sites, newly formed trabecular bone with large marrow spaces was plentiful in the most peripheral areas of the defects but sparse elsewhere. In contrast, in test sites, a large quantity of newly formed bone around the biomaterial particles was detected in the central medullary portion of the defect. In addition, in several areas, the biomaterial particles were bridged by newly formed bone. The percentage of contact between newly formed bone and biomaterial particles was 71.2% ± 9.8%. Inside the central portion of the biomaterial particles, it was possible to see newly formed bone (about 35.3% ± 4.8% in each particle). In test sites, newly formed bone represented 31.1% ± 1.9% of the material, with residual biomaterial particles occupying 33.4% ± 2.8% and marrow spaces another 34.7% ± 4.3%. In the control sites, the values were 30.2% ± 2.2% for newly formed bone and 68.7% ± 4.1% for marrow spaces. A statistically significant difference was found in the percentage of marrow space between the two groups, but no significant difference was observed in the percentage of newly formed bone. The present rabbit study confirmed the high osteoconductivity and resorbability of this biomaterial.
- 24 March 2012
- Vol. 27 (2) , 336-40
Bone regeneration with algae-derived hydroxyapatite: a pilot histologic and histomorphometric study in rabbit tibia defects.
Algipore is a biologic hydroxyapatite derived from calcifying maritime algae. The present study evaluated this material histologically and histomorphometrically after implantation in rabbit tibia defects for 4 weeks. Six New Zealand rabbits were used in this study. In each rabbit tibia, two 7-mm defects were prepared. Control defects were left empty, and test defects were filled with Algipore. Twenty-four specimens (12 test and 12 control) were retrieved and processed for histology. In control sites, newly formed trabecular bone with large marrow spaces was plentiful in the most peripheral areas of the defects but sparse elsewhere. In contrast, in test sites, a large quantity of newly formed bone around the biomaterial particles was detected in the central medullary portion of the defect. In addition, in several areas, the biomaterial particles were bridged by newly formed bone. The percentage of contact between newly formed bone and biomaterial particles was 71.2% ± 9.8%. Inside the central portion of the biomaterial particles, it was possible to see newly formed bone (about 35.3% ± 4.8% in each particle). In test sites, newly formed bone represented 31.1% ± 1.9% of the material, with residual biomaterial particles occupying 33.4% ± 2.8% and marrow spaces another 34.7% ± 4.3%. In the control sites, the values were 30.2% ± 2.2% for newly formed bone and 68.7% ± 4.1% for marrow spaces. A statistically significant difference was found in the percentage of marrow space between the two groups, but no significant difference was observed in the percentage of newly formed bone. The present rabbit study confirmed the high osteoconductivity and resorbability of this biomaterial.
- 6 December 2011
- Vol. 31 (6) , 633-9
Fractal analysis: a novel method to assess roughness organization of implant surface topography.
Surface roughness is important for implant osseointegration. It has mostly been assessed by amplitude and height descriptors. Fractal analysis is derived from fractal geometry and is used to describe the organization of objects found in nature, quantifying their shape complexity with a value. Fractal dimension (Df?) is an index of the space-filling properties of an object and can be used as a parameter that describes the organization of surface roughness. The greater the Df value, the more chaotic the surface topography. The aim of this study was to assess the Df of implants with three different surface topographies to evaluate whether a novel method to measure roughness of implant surface topography could be developed. Forty-five disk-shaped samples (10 x 2 mm) with three different surface topographies were analyzed by scanning electron microscopy: group A, machined surface; group B, sandblasted and acid-etched surface; and group C, sandblasted, acid-etched, and neutralized surface. Images at 20,000x and 50,000x magnification were processed for quantitative analysis of Df using the box-counting method. Df values were correlated to the image magnification. At 20,000x magnification, Df for groups A, B, and C was 1.81, 1.67, and 1.59, respectively. At 50,000x magnification, Df was lower for all examined groups; more specifically, Df was 1.77, 1.59, and 1.42 for groups A, B, and C, respectively. Statistically significant differences were found between groups A and C at both magnifications. Df is used widely and successfully as a measurement to characterize anatomical structures and physiologic and pathologic processes. Df not only provides an index of roughness size values, but also a measure of roughness spatial organization; therefore, it could be a promising method to differentiate between rough surfaces capable of supporting osseointegration.
- 6 December 2011
- Vol. 31 (6) , 633-9
Fractal analysis: a novel method to assess roughness organization of implant surface topography.
Surface roughness is important for implant osseointegration. It has mostly been assessed by amplitude and height descriptors. Fractal analysis is derived from fractal geometry and is used to describe the organization of objects found in nature, quantifying their shape complexity with a value. Fractal dimension (Df?) is an index of the space-filling properties of an object and can be used as a parameter that describes the organization of surface roughness. The greater the Df value, the more chaotic the surface topography. The aim of this study was to assess the Df of implants with three different surface topographies to evaluate whether a novel method to measure roughness of implant surface topography could be developed. Forty-five disk-shaped samples (10 x 2 mm) with three different surface topographies were analyzed by scanning electron microscopy: group A, machined surface; group B, sandblasted and acid-etched surface; and group C, sandblasted, acid-etched, and neutralized surface. Images at 20,000x and 50,000x magnification were processed for quantitative analysis of Df using the box-counting method. Df values were correlated to the image magnification. At 20,000x magnification, Df for groups A, B, and C was 1.81, 1.67, and 1.59, respectively. At 50,000x magnification, Df was lower for all examined groups; more specifically, Df was 1.77, 1.59, and 1.42 for groups A, B, and C, respectively. Statistically significant differences were found between groups A and C at both magnifications. Df is used widely and successfully as a measurement to characterize anatomical structures and physiologic and pathologic processes. Df not only provides an index of roughness size values, but also a measure of roughness spatial organization; therefore, it could be a promising method to differentiate between rough surfaces capable of supporting osseointegration.