Jean-Marc Legeais
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jean-Marc Legeais has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
G Renard
26 shared publicationsY Pouliquen
13 shared publicationsF D'Hermies
7 shared publicationsP Dighiero
7 shared publicationsP Ellies
6 shared publicationsB Briat
5 shared publications
Latest Publications
- 1 October 2003
- Vol. 26 (8) , 882-6
[Corneal edema in pseudophakia. A case report].
Pseudophakic bullous keratopathy is one of the most common complications of intraocular lenses, which explains the high rate of this condition in series of patients experiencing corneal grafts. It is caused by irreversible damage to the endothelial layer of the implanted eye involving the artificial lens, and occurs either during cataract extraction or after the operation. Intraoperative endothelial protection and the choice of an appropriate lens may contribute to decreasing this secondary disease, which can have severe consequences for many patients whose corneal graft may not restore their visual potential as well as expected. We report a clinicopathological case of a 59-year-old male, previously operated on for cataract in both eyes with an anterior chamber lens. A bilateral corneal edema occurred a few years after the operation, with a bilateral decrease in vision as a consequence. A corneal graft was performed in 2000 on the left eye in order to improve the patient's visual autonomy. The best treatment of this condition remains prevention, avoiding the use of this type of intraocular lens, whose main complication is corneal edema.
- 1 October 2003
- Vol. 26 (8) , 882-6
[Corneal edema in pseudophakia. A case report].
Pseudophakic bullous keratopathy is one of the most common complications of intraocular lenses, which explains the high rate of this condition in series of patients experiencing corneal grafts. It is caused by irreversible damage to the endothelial layer of the implanted eye involving the artificial lens, and occurs either during cataract extraction or after the operation. Intraoperative endothelial protection and the choice of an appropriate lens may contribute to decreasing this secondary disease, which can have severe consequences for many patients whose corneal graft may not restore their visual potential as well as expected. We report a clinicopathological case of a 59-year-old male, previously operated on for cataract in both eyes with an anterior chamber lens. A bilateral corneal edema occurred a few years after the operation, with a bilateral decrease in vision as a consequence. A corneal graft was performed in 2000 on the left eye in order to improve the patient's visual autonomy. The best treatment of this condition remains prevention, avoiding the use of this type of intraocular lens, whose main complication is corneal edema.
- 1 May 2001
- Vol. 24 (5) , 546-56
[Human amniotic membrane transplantation in the treatment of ocular surface diseases].
- 1 May 2001
- Vol. 24 (5) , 546-56
[Human amniotic membrane transplantation in the treatment of ocular surface diseases].
- 1 September 2000
- Vol. 23 (7) , 735-7
[Avellino dystrophy. Current diagnostic criteria].
We report a French family suffering from an Avellino corneal dystrophy diagnosed by using clinical, histological, ultrastructural and genetics findings. Our results indicate that direct corneal examination and routine histological examinations must always be associated with an assay for BIGH3 gene mutations to establish a modern and unambiguous diagnosis of a corneal dystrophy.
- 1 September 2000
- Vol. 23 (7) , 735-7
[Avellino dystrophy. Current diagnostic criteria].
We report a French family suffering from an Avellino corneal dystrophy diagnosed by using clinical, histological, ultrastructural and genetics findings. Our results indicate that direct corneal examination and routine histological examinations must always be associated with an assay for BIGH3 gene mutations to establish a modern and unambiguous diagnosis of a corneal dystrophy.
- 23 August 2000
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 238 (8) , 696-700
Inhibition of lens epithelial cell proliferation by substituted PMMA intraocular lenses
Background: Migration and proliferation of lens epithelial cells (LECs) are based on interactions between cellular integrins and extracellular matrix proteins (ECMs). We were able to design polymers substituted with COO– and SO3–groups that counteract LEC proliferation through modification of the integrin/ECM interaction. The objective of this study was to compare the cell proliferation-inhibiting properties of differently substituted copolymers with those of a homopolymer. Methods: Polymers were synthesized by radical polymerization and characterized by nuclear resonance spectroscopy. Second- passage rabbit LECs were cultured either on PMMA homopolymers (control) or on substituted PMMA copolymers. Cells were counted on days 2, 7, and 17. Cell vitality was evaluated by trypan blue staining. Experiments were run in quadruplicate. Statistical analysis was performed using the Wilcoxon test and the Mann-WhitneyU-test. Results: Compared with control, cells cultured on copolymers grew to significantly lower cell numbers. The inhibitory effect became evident at day 2 after seeding and persisted throughout the experiment. Different ratios of COO–/SO3– substitutions yielded different grades of inhibition. No toxic effect was seen on rabbit LECs. Conclusions: The tested copolymers inhibit cell proliferation and are nontoxic. Further evaluation could lead to the development of new intraocular lens materials that prevent secondary cataract.
- 23 August 2000
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 238 (8) , 696-700
Inhibition of lens epithelial cell proliferation by substituted PMMA intraocular lenses
Background: Migration and proliferation of lens epithelial cells (LECs) are based on interactions between cellular integrins and extracellular matrix proteins (ECMs). We were able to design polymers substituted with COO– and SO3–groups that counteract LEC proliferation through modification of the integrin/ECM interaction. The objective of this study was to compare the cell proliferation-inhibiting properties of differently substituted copolymers with those of a homopolymer. Methods: Polymers were synthesized by radical polymerization and characterized by nuclear resonance spectroscopy. Second- passage rabbit LECs were cultured either on PMMA homopolymers (control) or on substituted PMMA copolymers. Cells were counted on days 2, 7, and 17. Cell vitality was evaluated by trypan blue staining. Experiments were run in quadruplicate. Statistical analysis was performed using the Wilcoxon test and the Mann-WhitneyU-test. Results: Compared with control, cells cultured on copolymers grew to significantly lower cell numbers. The inhibitory effect became evident at day 2 after seeding and persisted throughout the experiment. Different ratios of COO–/SO3– substitutions yielded different grades of inhibition. No toxic effect was seen on rabbit LECs. Conclusions: The tested copolymers inhibit cell proliferation and are nontoxic. Further evaluation could lead to the development of new intraocular lens materials that prevent secondary cataract.
- 1 April 2000
- Vol. 23 (4) , 345-9
[Therapeutic photokeratectomy for the treatment of band keratopathy].
This retrospective study was designed to investigate the therapeutic potential of phototherapeutic keratectomy (PTK) for the treatment of band keratopathy. PTK was performed with the Excimed UV 200, (Summit Technology, Inc) on 27 eyes of 22 patients and with the Nidek EC5000 on 11 eyes of 10 patients with band keratopathy. Mean patient age was 57 years. The mean follow-up period was 19 months (ranged from 4 to 54 months). When possible, the change in best corrected visual acuity and spherical equivalent was evaluated at 6, 12, 18 and 24 months. Almost 90% of patients with smooth bands achieved visual improvement and 85% of patients with rough bands improved ocular discomfort. The mean hyperopic shift caused by tissue ablation was less than +2.0D after one year, for smooth bands. Excimer laser PTK is a safe and effective outpatient treatment and should be used as initial treatment for band keratopathy.
- 1 April 2000
- Vol. 23 (4) , 345-9
[Therapeutic photokeratectomy for the treatment of band keratopathy].
This retrospective study was designed to investigate the therapeutic potential of phototherapeutic keratectomy (PTK) for the treatment of band keratopathy. PTK was performed with the Excimed UV 200, (Summit Technology, Inc) on 27 eyes of 22 patients and with the Nidek EC5000 on 11 eyes of 10 patients with band keratopathy. Mean patient age was 57 years. The mean follow-up period was 19 months (ranged from 4 to 54 months). When possible, the change in best corrected visual acuity and spherical equivalent was evaluated at 6, 12, 18 and 24 months. Almost 90% of patients with smooth bands achieved visual improvement and 85% of patients with rough bands improved ocular discomfort. The mean hyperopic shift caused by tissue ablation was less than +2.0D after one year, for smooth bands. Excimer laser PTK is a safe and effective outpatient treatment and should be used as initial treatment for band keratopathy.
- 1 May 1999
- Vol. 22 (4) , 492-501
[Materials for intraocular lenses. II. Silicone intraocular lenses].
- 1 May 1999
- Vol. 22 (4) , 492-501
[Materials for intraocular lenses. II. Silicone intraocular lenses].
- 1 March 1999
- Vol. 22 (2) , 176-9
[Phototherapeutic keratectomy in the treatment of Groenouw's type I corneal dystrophy].
This study was designed to investigate the therapeutic potential of phototherapeutic keratectomy (PTK) for the treatment of corneal granular dystrophy. PTK was performed with the Excimed UV 200, (Summit Technology, Inc) on a series of 27 eyes of 22 patients with corneal granular dystrophy. Mean patients' age was 34.6 years. The mean follow-up period was 31 months (ranged from 6 to 52 months). The changes in best corrected visual acuity and spherical equivalent were evaluated at 6, 12, 18 and 24 months. All of patients achieved visual improvement. Mean preoperative best corrected visual acuity (BCVA) was 20/100 and mean postoperative BCVA was 20/30 at one year. The mean hyperopic shift caused by tissue ablation was +/- 2.8 D after one year. Corneal grafting was the standard treatment for visually disabling granular dystrophy, but PTK has significant advantages over this procedure and must now be the standard method of managing corneal granular dystrophy when intervention is required.
- 1 March 1999
- Vol. 22 (2) , 176-9
[Phototherapeutic keratectomy in the treatment of Groenouw's type I corneal dystrophy].
This study was designed to investigate the therapeutic potential of phototherapeutic keratectomy (PTK) for the treatment of corneal granular dystrophy. PTK was performed with the Excimed UV 200, (Summit Technology, Inc) on a series of 27 eyes of 22 patients with corneal granular dystrophy. Mean patients' age was 34.6 years. The mean follow-up period was 31 months (ranged from 6 to 52 months). The changes in best corrected visual acuity and spherical equivalent were evaluated at 6, 12, 18 and 24 months. All of patients achieved visual improvement. Mean preoperative best corrected visual acuity (BCVA) was 20/100 and mean postoperative BCVA was 20/30 at one year. The mean hyperopic shift caused by tissue ablation was +/- 2.8 D after one year. Corneal grafting was the standard treatment for visually disabling granular dystrophy, but PTK has significant advantages over this procedure and must now be the standard method of managing corneal granular dystrophy when intervention is required.
- 1 March 1999
- Vol. 22 (2) , 226-33
[Review on corneal dystrophies].
- 1 January 1999
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 48 (6) , 807-813
e‐PTFE as scleral buckling episcleral implants: An experimental and histopathologic study
- 1 January 1999
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 48 (6) , 807-813
e‐PTFE as scleral buckling episcleral implants: An experimental and histopathologic study
- 1 January 1999
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 48 (6) , 814-819
Neutral red assay of the cytotoxicity of fluorocarbon-coated polymethylmethacrylate intraocular lenses in vitro
Polymethylmethacrylate (PMMA) intraocular lenses (IOLs) were coated with Teflon AF, an amorphous, transparent Teflon, to render them highly hydrophobic. Teflon-coated PMMA IOLs were immersed in culture medium for 30 days at 37°C. Four concentrations of the IOL leachables, 2 concentrations of a toxic control (phenol), and complete liquid culture medium (nontoxic control) were incubated for 24 h in a 96-well plate containing confluent L-929 fibroblasts. The cytotoxic effect of each solution on the fibroblasts was quantitatively assessed by measuring the uptake of neutral red by the viable cells. After the extraction of the neutral red using 1% acetic acid–50% ethanol, the optical densities were measured with a microplate reader at 550 nm. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) were used to analyze the surfaces of the IOLs. Only the optical densities in the wells containing fibroblasts that had been in contact with the phenol solutions were significantly lower than those in the wells incubated with the nontoxic control solution (p < 0.01). There were no signs of surface alteration by SEM, apart from some crystals on the IOLs. The crystals were composed of Na and Cl, as demonstrated by XPS. Aqueous extractables from the Teflon-coated IOLs produced no cytotoxic effects in the neutral red assay used. © 1999 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 48: 814–819, 1999
- 1 January 1999
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 48 (6) , 814-819
Neutral red assay of the cytotoxicity of fluorocarbon-coated polymethylmethacrylate intraocular lenses in vitro
Polymethylmethacrylate (PMMA) intraocular lenses (IOLs) were coated with Teflon AF, an amorphous, transparent Teflon, to render them highly hydrophobic. Teflon-coated PMMA IOLs were immersed in culture medium for 30 days at 37°C. Four concentrations of the IOL leachables, 2 concentrations of a toxic control (phenol), and complete liquid culture medium (nontoxic control) were incubated for 24 h in a 96-well plate containing confluent L-929 fibroblasts. The cytotoxic effect of each solution on the fibroblasts was quantitatively assessed by measuring the uptake of neutral red by the viable cells. After the extraction of the neutral red using 1% acetic acid–50% ethanol, the optical densities were measured with a microplate reader at 550 nm. Scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) were used to analyze the surfaces of the IOLs. Only the optical densities in the wells containing fibroblasts that had been in contact with the phenol solutions were significantly lower than those in the wells incubated with the nontoxic control solution (p < 0.01). There were no signs of surface alteration by SEM, apart from some crystals on the IOLs. The crystals were composed of Na and Cl, as demonstrated by XPS. Aqueous extractables from the Teflon-coated IOLs produced no cytotoxic effects in the neutral red assay used. © 1999 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 48: 814–819, 1999