Boel Bengtsson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Boel Bengtsson has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Anders Heijl
5 shared publications- Anders Heijl
Department of Ophthalmology, Malmö University Hospital, Malmö, Sweden
4 shared publications A. Heijl
Department of Clinical Sciences, Ophthalmology, Malmö University Hospital, Malmö, Sweden
1 shared publicationE. Agardh
Department of Clinical Sciences, Ophthalmology, Malmö University Hospital, Malmö, Sweden
1 shared publicationJ Mesterton
1 shared publicationJg Walt
1 shared publication
Latest Publications
- 30 June 2008
- Published by Elsevier in Value in Health
- Vol. 11 (3) , A285-A286
PSS5 MEDICAL COST OF GLAUCOMA IN SWEDEN
- 30 June 2008
- Published by Elsevier in Value in Health
- Vol. 11 (3) , A285-A286
PSS5 MEDICAL COST OF GLAUCOMA IN SWEDEN
- 1 November 2005
- Published by Springer Nature in Diabetologia
- Vol. 48 (12) , 2494-2500
Visual fields correlate better than visual acuity to severity of diabetic retinopathy
Aims/hypothesis We compared the outcomes of perimetric and visual acuity tests in patients with diabetic retinopathy. Methods We examined 59 diabetic patients with different degrees of retinopathy using stereo fundus photography in accordance with the Early Treatment of Diabetic Retinopathy Study (ETDRS) and fluorescein angiography. Conventional white-on-white perimetry (WWP) and short wavelength automated perimetry (SWAP) were performed and analysed with reference to normal values. Visual acuity was measured with ETDRS charts. Results Regression analysis revealed that visual acuity was significantly associated with increasing severity of retinopathy according to the ETDRS scale when visual acuity was estimated by counting logarithm of minimum angle of resolution (LogMar) scores, but not when visual acuity was measured by the conventional reading of the smallest line that could be seen. Visual acuity decreased by 0.02 LogMar per ETDRS step (p=0.03). The degree of visual field loss was significantly associated with increasing severity of retinopathy according to the ETDRS scale, perimetric sensitivity decreasing by 0.44 dB per ETDRS step (p=0.0001) using WWP, and by 0.40 dB per ETDRS step (p=0.04) with SWAP. The size of the area of the foveal avascular zone and adjacent perifoveal intercapillary areas (PIAs) also affected the central visual field as obtained both by WWP (−2.6 dB/mm2, p=0.03), and by SWAP (−7.9 dB/mm2, p=0.002), but did not affect visual acuity. The regression model fit for peripheral retinopathy according to the ETDRS scale was better using WWP than SWAP or visual acuity, while SWAP testing was superior to both WWP and visual acuity when measuring effects caused by enlarged foveal avascular zones and PIAs. Conclusions/interpretation Perimetry can provide more useful information than visual acuity on functional loss in diabetic retinopathy, particularly when the perifoveal capillary network is damaged.
- 1 November 2005
- Published by Springer Nature in Diabetologia
- Vol. 48 (12) , 2494-2500
Visual fields correlate better than visual acuity to severity of diabetic retinopathy
Aims/hypothesis We compared the outcomes of perimetric and visual acuity tests in patients with diabetic retinopathy. Methods We examined 59 diabetic patients with different degrees of retinopathy using stereo fundus photography in accordance with the Early Treatment of Diabetic Retinopathy Study (ETDRS) and fluorescein angiography. Conventional white-on-white perimetry (WWP) and short wavelength automated perimetry (SWAP) were performed and analysed with reference to normal values. Visual acuity was measured with ETDRS charts. Results Regression analysis revealed that visual acuity was significantly associated with increasing severity of retinopathy according to the ETDRS scale when visual acuity was estimated by counting logarithm of minimum angle of resolution (LogMar) scores, but not when visual acuity was measured by the conventional reading of the smallest line that could be seen. Visual acuity decreased by 0.02 LogMar per ETDRS step (p=0.03). The degree of visual field loss was significantly associated with increasing severity of retinopathy according to the ETDRS scale, perimetric sensitivity decreasing by 0.44 dB per ETDRS step (p=0.0001) using WWP, and by 0.40 dB per ETDRS step (p=0.04) with SWAP. The size of the area of the foveal avascular zone and adjacent perifoveal intercapillary areas (PIAs) also affected the central visual field as obtained both by WWP (−2.6 dB/mm2, p=0.03), and by SWAP (−7.9 dB/mm2, p=0.002), but did not affect visual acuity. The regression model fit for peripheral retinopathy according to the ETDRS scale was better using WWP than SWAP or visual acuity, while SWAP testing was superior to both WWP and visual acuity when measuring effects caused by enlarged foveal avascular zones and PIAs. Conclusions/interpretation Perimetry can provide more useful information than visual acuity on functional loss in diabetic retinopathy, particularly when the perifoveal capillary network is damaged.
- 1 April 2005
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 14 (2) , 135-138
A Long-Term Prospective Study of Risk Factors for Glaucomatous Visual Field Loss in Patients With Ocular Hypertension
To evaluate the importance of baseline risk factors for development of glaucomatous visual field loss in patients with high-risk ocular hypertension. In the Malmö Ocular Hypertension Study, 90 patients were randomized to topical timolol or placebo treatment and observed prospectively for up to 10 years. Patients with elevated intraocular pressure (IOP) and with open angles and normal visual fields, plus at least one extra risk factor, were eligible. Risk factors were suspect disc or known disc hemorrhage, positive family history of glaucoma, pseudoexfoliation or pigment dispersion syndrome, diabetes, and mean IOP on DTC ≥ 27 mm Hg. These risk factors and also the mean baseline IOP and IOP fluctuation, sex, age, and blood pressure were evaluated as predictors for development of reproducible glaucomatous visual field loss. In addition to the prospective data, post-study data were retrieved from patients' records extending maximum follow-up to 17 years. Thirty-seven patients developed glaucomatous visual field loss. Of all factors included in the analysis, disc appearance, older age, and higher IOP came out as significant risks. Suspect disc appearance increased the risk approximately three times, with a hazard ratio of 2.90, and CI: 1.34-6.30, the hazard ratio was 1.05 and CI: 1.03-1.09 per year of age, while mean baseline IOP increased the risk with 14% per mm Hg (CI: 1.01-1.28). Patients with ocular hypertension were at higher risk for developing glaucomatous visual field loss if discs were suspect, if IOP was high, and if the patient was older in age.
- 1 April 2005
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 14 (2) , 135-138
A Long-Term Prospective Study of Risk Factors for Glaucomatous Visual Field Loss in Patients With Ocular Hypertension
To evaluate the importance of baseline risk factors for development of glaucomatous visual field loss in patients with high-risk ocular hypertension. In the Malmö Ocular Hypertension Study, 90 patients were randomized to topical timolol or placebo treatment and observed prospectively for up to 10 years. Patients with elevated intraocular pressure (IOP) and with open angles and normal visual fields, plus at least one extra risk factor, were eligible. Risk factors were suspect disc or known disc hemorrhage, positive family history of glaucoma, pseudoexfoliation or pigment dispersion syndrome, diabetes, and mean IOP on DTC ≥ 27 mm Hg. These risk factors and also the mean baseline IOP and IOP fluctuation, sex, age, and blood pressure were evaluated as predictors for development of reproducible glaucomatous visual field loss. In addition to the prospective data, post-study data were retrieved from patients' records extending maximum follow-up to 17 years. Thirty-seven patients developed glaucomatous visual field loss. Of all factors included in the analysis, disc appearance, older age, and higher IOP came out as significant risks. Suspect disc appearance increased the risk approximately three times, with a hazard ratio of 2.90, and CI: 1.34-6.30, the hazard ratio was 1.05 and CI: 1.03-1.09 per year of age, while mean baseline IOP increased the risk with 14% per mm Hg (CI: 1.01-1.28). Patients with ocular hypertension were at higher risk for developing glaucomatous visual field loss if discs were suspect, if IOP was high, and if the patient was older in age.
- 9 March 2005
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 243 (6) , 513-518
Diurnal IOP fluctuation: not an independent risk factor for glaucomatous visual field loss in high-risk ocular hypertension
To establish whether intraocular pressure (IOP) fluctuations contribute to the risk of developing glaucoma in patients with high-risk ocular hypertension. Ninety patients included in the Malmö Ocular Hypertension Study were examined every 3 months with office-hours diurnal tension curves and computerised perimetry. Patients were followed up prospectively for 10 years or until glaucomatous visual field loss could be demonstrated. Poststudy data were included in the analyses, extending maximum follow-up to 17 years. After 17 years, 37 patients had developed glaucomatous visual field defects. When applying univariate Cox regression analyses, mean IOP of all measurements during the prospective part of the study was a significant risk factor for developing glaucoma (95% confidence interval [CI] 1.08–1.39), while IOP fluctuations were almost significant (95% CI 0.98–1.93). When separating effects of mean IOP level and mean IOP fluctuation using Cox multiple regression analysis, only IOP level came out as significant (95% CI 1.09–1.38), and IOP fluctuations did not contribute to the risk (95% CI 0.80–1.60). IOP fluctuation depended linearly on IOP level (p<0.0001), i.e. IOP fluctuation was larger in eyes with higher IOP levels. IOP fluctuations were not an independent risk factor for the incidence of glaucomatous visual field loss in subjects with ocular hypertension.
- 9 March 2005
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 243 (6) , 513-518
Diurnal IOP fluctuation: not an independent risk factor for glaucomatous visual field loss in high-risk ocular hypertension
To establish whether intraocular pressure (IOP) fluctuations contribute to the risk of developing glaucoma in patients with high-risk ocular hypertension. Ninety patients included in the Malmö Ocular Hypertension Study were examined every 3 months with office-hours diurnal tension curves and computerised perimetry. Patients were followed up prospectively for 10 years or until glaucomatous visual field loss could be demonstrated. Poststudy data were included in the analyses, extending maximum follow-up to 17 years. After 17 years, 37 patients had developed glaucomatous visual field defects. When applying univariate Cox regression analyses, mean IOP of all measurements during the prospective part of the study was a significant risk factor for developing glaucoma (95% confidence interval [CI] 1.08–1.39), while IOP fluctuations were almost significant (95% CI 0.98–1.93). When separating effects of mean IOP level and mean IOP fluctuation using Cox multiple regression analysis, only IOP level came out as significant (95% CI 1.09–1.38), and IOP fluctuations did not contribute to the risk (95% CI 0.80–1.60). IOP fluctuation depended linearly on IOP level (p<0.0001), i.e. IOP fluctuation was larger in eyes with higher IOP levels. IOP fluctuations were not an independent risk factor for the incidence of glaucomatous visual field loss in subjects with ocular hypertension.
- 1 November 2003
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 44 (11) , 5029-5034
Normal Intersubject Threshold Variability and Normal Limits of the SITA SWAP and Full Threshold SWAP Perimetric Programs
Purpose. To compare intersubject variability and normal limits of threshold values between the new Swedish interactive test algorithm short wavelength automated perimetry (SITA SWAP) and the older Full Threshold SWAP programs (Carl Zeiss Meditec, Dublin, CA). methods. Normal reduction of differential light sensitivity with age, age-corrected thresholds, intersubject variability, and normal limits of sensitivity were calculated from SITA SWAP and Full Threshold SWAP fields obtained in 53 normal subjects between 20 and 72 years of age. results. Age influence on threshold sensitivity was the same with the two SWAP programs. On average, sensitivity decreased by 0.13 dB per year of age. Age-corrected normal threshold sensitivity was significantly higher (P < 0.0001) for SITA SWAP than for Full Threshold SWAP. The means for a subject 45.4 years of age were 28.8 dB with SITA SWAP and 24.4 dB with Full Threshold SWAP. Intersubject variance was 22% smaller with SITA SWAP than with Full Threshold SWAP. Normal limits at the P < 5% significance level were, on average, 14% narrower with SITA SWAP than with Full Threshold SWAP using Total Deviations from age-corrected normal thresholds and 11% narrower when applying Pattern Deviation, which is intended to adjust for general depression or elevation of the field. conclusions. SITA SWAP test results from normal eyes showed higher sensitivities than results from the older Full Threshold SWAP. This represents an increase of the dynamic range, which implies that more patients can be tested with SWAP. The smaller intersubject variability with SITA SWAP means narrower normal limits and may be associated with more sensitive probability maps.
- 1 November 2003
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 44 (11) , 5029-5034
Normal Intersubject Threshold Variability and Normal Limits of the SITA SWAP and Full Threshold SWAP Perimetric Programs
Purpose. To compare intersubject variability and normal limits of threshold values between the new Swedish interactive test algorithm short wavelength automated perimetry (SITA SWAP) and the older Full Threshold SWAP programs (Carl Zeiss Meditec, Dublin, CA). methods. Normal reduction of differential light sensitivity with age, age-corrected thresholds, intersubject variability, and normal limits of sensitivity were calculated from SITA SWAP and Full Threshold SWAP fields obtained in 53 normal subjects between 20 and 72 years of age. results. Age influence on threshold sensitivity was the same with the two SWAP programs. On average, sensitivity decreased by 0.13 dB per year of age. Age-corrected normal threshold sensitivity was significantly higher (P < 0.0001) for SITA SWAP than for Full Threshold SWAP. The means for a subject 45.4 years of age were 28.8 dB with SITA SWAP and 24.4 dB with Full Threshold SWAP. Intersubject variance was 22% smaller with SITA SWAP than with Full Threshold SWAP. Normal limits at the P < 5% significance level were, on average, 14% narrower with SITA SWAP than with Full Threshold SWAP using Total Deviations from age-corrected normal thresholds and 11% narrower when applying Pattern Deviation, which is intended to adjust for general depression or elevation of the field. conclusions. SITA SWAP test results from normal eyes showed higher sensitivities than results from the older Full Threshold SWAP. This represents an increase of the dynamic range, which implies that more patients can be tested with SWAP. The smaller intersubject variability with SITA SWAP means narrower normal limits and may be associated with more sensitive probability maps.
- Open Access
- 1 December 2002
- Published by Wiley in Acta Ophthalmologica Scandinavica
- Vol. 80 (6) , 620-626
Evaluation of VEP perimetry in normal subjects and glaucoma patients
: Purpose: To estimate sensitivity to glaucomatous visual field loss using multifocal visual evoked potential (VEP) perimetry, to compare these findings to those of conventional achromatic perimetry and to determine specificity of VEP perimetry in normal subjects.Methods: A total of 33 glaucoma patients with known visual field defects in at least one eye on standard computerized perimetry and 33 healthy subjects were tested with VEP perimetry. The glaucoma patients were also tested with standard computerized perimetry using the 30–2 SITA Fast program of the Humphrey Field Analyzer (HFA). Visual evoked potential perimetry classification and VEP probability maps were used to determine the sensitivity and specificity of the technique.Results: Visual evoked potential perimetry classified 68% of all eyes in the glaucoma group (45/66) as pathological; sensitivity increased to 81% (38/47) when considering only those eyes with HFA field defects. It also identified more test locations with significant loss at the p < 5% level in both groups (48% and 37%, respectively) than did HFA, while HFA identified more loss at the higher significance levels p < 2%, and p < 1%. Visual evoked potential perimetry showed more significant loss in eyes with almost normal or slightly damaged standard fields, while HFA identified more significant field loss in eyes with severe conventional field damage. The mean VEP amplitude of the 66 glaucoma eyes was 1.461e−7 V; it was 1.676e−7 V for the 66 control eyes. This difference was significant (p = 0.0033), but the overlap between groups was large. Visual evoked potential perimetry classified 42% of the control eyes as ‘outside normal limits’, and VEP probability maps showed 30.0% of test segments as significantly depressed at the p < 5% level, 10.8% of sites at p < 2%, and 4.6% at the p < 1% level.Conclusion: Mean VEP amplitude differed significantly between normal and glaucoma eyes, but the overlap was considerable. Visual evoked potential perimetry falsely classified a large number of normal eyes as pathological and showed many more significantly depressed test locations than expected. Agreement between VEP and standard perimetry was relatively poor for the glaucoma group. Further refinements are needed before VEP perimetry can be regarded as a reliable clinical method of mapping glaucomatous visual fields.
- 1 December 2002
- Published by Wiley in Acta Ophthalmologica Scandinavica
- Vol. 80 (6) , 620-626
Open AccessEvaluation of VEP perimetry in normal subjects and glaucoma patients
: Purpose: To estimate sensitivity to glaucomatous visual field loss using multifocal visual evoked potential (VEP) perimetry, to compare these findings to those of conventional achromatic perimetry and to determine specificity of VEP perimetry in normal subjects.Methods: A total of 33 glaucoma patients with known visual field defects in at least one eye on standard computerized perimetry and 33 healthy subjects were tested with VEP perimetry. The glaucoma patients were also tested with standard computerized perimetry using the 30–2 SITA Fast program of the Humphrey Field Analyzer (HFA). Visual evoked potential perimetry classification and VEP probability maps were used to determine the sensitivity and specificity of the technique.Results: Visual evoked potential perimetry classified 68% of all eyes in the glaucoma group (45/66) as pathological; sensitivity increased to 81% (38/47) when considering only those eyes with HFA field defects. It also identified more test locations with significant loss at the p < 5% level in both groups (48% and 37%, respectively) than did HFA, while HFA identified more loss at the higher significance levels p < 2%, and p < 1%. Visual evoked potential perimetry showed more significant loss in eyes with almost normal or slightly damaged standard fields, while HFA identified more significant field loss in eyes with severe conventional field damage. The mean VEP amplitude of the 66 glaucoma eyes was 1.461e−7 V; it was 1.676e−7 V for the 66 control eyes. This difference was significant (p = 0.0033), but the overlap between groups was large. Visual evoked potential perimetry classified 42% of the control eyes as ‘outside normal limits’, and VEP probability maps showed 30.0% of test segments as significantly depressed at the p < 5% level, 10.8% of sites at p < 2%, and 4.6% at the p < 1% level.Conclusion: Mean VEP amplitude differed significantly between normal and glaucoma eyes, but the overlap was considerable. Visual evoked potential perimetry falsely classified a large number of normal eyes as pathological and showed many more significantly depressed test locations than expected. Agreement between VEP and standard perimetry was relatively poor for the glaucoma group. Further refinements are needed before VEP perimetry can be regarded as a reliable clinical method of mapping glaucomatous visual fields.
- 1 November 2001
- Vol. 42 (12) , 2839-42
Lack of long-term drift in timolol's effectiveness in patients with ocular hypertension.
To report the change over time in intraocular pressure in patients treated with topical timolol or placebo. Ninety patients with untreated ocular hypertension, defined as elevated intraocular pressure and normal visual fields, were randomly assigned to treatment and prospectively observed at 3-month intervals for up to 10 years in a double-masked fashion. The study end point was one eye showing reproducible glaucomatous field defects; patients were also withdrawn if one eye showed intraocular pressure of 35 mm Hg or higher. For each treatment group and visit, the mean and median of all intraocular pressure measurements were calculated. Medians were also calculated for the timolol group, assuming a worst-case scenario in which all patients who reached the end point, or intraocular pressure of 35 mm Hg or more, were assumed to show higher intraocular pressure than those remaining in the study. Distributions of slopes for intraocular pressure over time were compared between treatment groups. Means and medians of follow-up intraocular pressure over time did not differ between timolol- and placebo-treated patients. This was also true when assuming a worst-case scenario. Slopes of intraocular pressure over time did not differ statistically between treatment groups. In agreement with other masked and controlled studies and in conflict with uncontrolled ones, the present study did not demonstrate long-term drift of intraocular pressure in patients with ocular hypertension treated with topical timolol.
- 1 November 2001
- Vol. 42 (12) , 2839-42
Lack of long-term drift in timolol's effectiveness in patients with ocular hypertension.
To report the change over time in intraocular pressure in patients treated with topical timolol or placebo. Ninety patients with untreated ocular hypertension, defined as elevated intraocular pressure and normal visual fields, were randomly assigned to treatment and prospectively observed at 3-month intervals for up to 10 years in a double-masked fashion. The study end point was one eye showing reproducible glaucomatous field defects; patients were also withdrawn if one eye showed intraocular pressure of 35 mm Hg or higher. For each treatment group and visit, the mean and median of all intraocular pressure measurements were calculated. Medians were also calculated for the timolol group, assuming a worst-case scenario in which all patients who reached the end point, or intraocular pressure of 35 mm Hg or more, were assumed to show higher intraocular pressure than those remaining in the study. Distributions of slopes for intraocular pressure over time were compared between treatment groups. Means and medians of follow-up intraocular pressure over time did not differ between timolol- and placebo-treated patients. This was also true when assuming a worst-case scenario. Slopes of intraocular pressure over time did not differ statistically between treatment groups. In agreement with other masked and controlled studies and in conflict with uncontrolled ones, the present study did not demonstrate long-term drift of intraocular pressure in patients with ocular hypertension treated with topical timolol.
- Open Access
- 1 October 2000
- Published by Wiley in Acta Ophthalmologica Scandinavica
- Vol. 78 (5) , 519-522
Reliability of computerized perimetric threshold tests as assessed by reliability indices and threshold reproducibility in patients with suspect and manifest glaucoma
: Background: High reproducibility of test measurements is often considered an indication of high reliability of test results. The aim of the current study was to analyse the role of the traditional perimetric reliability indices, False Negative and False Positive responses, and Fixation Losses, as indicators of test reliability in comparison with threshold reproducibility in patients with suspect or manifest glaucoma.Methods: Perimetry was performed in one eye in each of 76 patients. Each eye was tested twice within approximately one week using the Humphrey II 30‐2 S ita S tandard program. Frequencies of False Positive and False Negative answers, and rates of Fixation Losses were related to threshold reproducibility and to general field status as expressed by Mean Deviation from age‐normal threshold values using stepwise multiple linear regression analysis.Results: Substantial field loss was associated both with low threshold reproducibility (pConclusion: Reliability of visual field test results in patients with glaucoma expressed as threshold reproducibility, can be predicted by amount of field loss alone, and traditional patient reliability indices contribute surprisingly little in this regard.
- 1 October 2000
- Published by Wiley in Acta Ophthalmologica Scandinavica
- Vol. 78 (5) , 519-522
Open AccessReliability of computerized perimetric threshold tests as assessed by reliability indices and threshold reproducibility in patients with suspect and manifest glaucoma
: Background: High reproducibility of test measurements is often considered an indication of high reliability of test results. The aim of the current study was to analyse the role of the traditional perimetric reliability indices, False Negative and False Positive responses, and Fixation Losses, as indicators of test reliability in comparison with threshold reproducibility in patients with suspect or manifest glaucoma.Methods: Perimetry was performed in one eye in each of 76 patients. Each eye was tested twice within approximately one week using the Humphrey II 30‐2 S ita S tandard program. Frequencies of False Positive and False Negative answers, and rates of Fixation Losses were related to threshold reproducibility and to general field status as expressed by Mean Deviation from age‐normal threshold values using stepwise multiple linear regression analysis.Results: Substantial field loss was associated both with low threshold reproducibility (pConclusion: Reliability of visual field test results in patients with glaucoma expressed as threshold reproducibility, can be predicted by amount of field loss alone, and traditional patient reliability indices contribute surprisingly little in this regard.
- 1 July 2000
- Vol. 41 (8) , 2201-4
False-negative responses in glaucoma perimetry: indicators of patient performance or test reliability?
To study whether false-negative answers in computerized glaucoma perimetry indicate the patient's ability to perform perimetry or test result reliability. A retrospective evaluation was performed of visual field test results obtained with a perimetry program (Humphrey 30-2 Sita Standard; Humphrey Instruments, San Leandro, CA) in 70 consecutive patients with unilateral glaucomatous field loss. Frequencies of false-negative answers were compared between the two eyes of each patient and related to amount of visual field damage in the glaucomatous eyes using linear regression analysis. Frequencies of false-negative answers were higher in eyes with field loss. The intrapatient intereye difference was 6.6% on average (P < 0.0001). In seven subjects with false-negative frequency of 5% or more in both eyes, the mean difference was 12.7% between eyes. The differences in false-negative answers depended significantly on the amount of field loss in the glaucomatous eyes (P = 0.0003). Larger differences were seen in patients with advanced field loss in the affected eye. The increased frequencies of false-negative answers in eyes with field loss were strongly associated with field status. The higher false-negative frequencies in eyes with glaucomatous field loss compared with unaffected eyes may be explained by the increased variability in threshold values typically found in such eyes. False-negative answers in patients with glaucoma therefore represent eye rather than patient status.
- 1 July 2000
- Vol. 41 (8) , 2201-4
False-negative responses in glaucoma perimetry: indicators of patient performance or test reliability?
To study whether false-negative answers in computerized glaucoma perimetry indicate the patient's ability to perform perimetry or test result reliability. A retrospective evaluation was performed of visual field test results obtained with a perimetry program (Humphrey 30-2 Sita Standard; Humphrey Instruments, San Leandro, CA) in 70 consecutive patients with unilateral glaucomatous field loss. Frequencies of false-negative answers were compared between the two eyes of each patient and related to amount of visual field damage in the glaucomatous eyes using linear regression analysis. Frequencies of false-negative answers were higher in eyes with field loss. The intrapatient intereye difference was 6.6% on average (P < 0.0001). In seven subjects with false-negative frequency of 5% or more in both eyes, the mean difference was 12.7% between eyes. The differences in false-negative answers depended significantly on the amount of field loss in the glaucomatous eyes (P = 0.0003). Larger differences were seen in patients with advanced field loss in the affected eye. The increased frequencies of false-negative answers in eyes with field loss were strongly associated with field status. The higher false-negative frequencies in eyes with glaucomatous field loss compared with unaffected eyes may be explained by the increased variability in threshold values typically found in such eyes. False-negative answers in patients with glaucoma therefore represent eye rather than patient status.