Non-contact, scattering-independent water absorption measurement using a falling stream and integrating sphere
We have applied an integrating sphere to the measurement of optical absorption in process waters containing high levels of scattering particles. The sphere greatly reduces the effects of scattering, which appear in a conventional transmission measurement as an apparent absorption. Additionally, the water sample flows through the sphere in the form of an unconstrained falling stream, allowing non-contact measurement and removing the fouling suffered by wetted cuvette windows. Using a 430 nm LED, silicon detector and 100 mm sphere, an absorbance resolution of approximately 0.01 has been demonstrated. Errors caused in a spectrometer measurement by levels of scattering contributing an apparent unit absorbance to a 0.2 absorbance dye solution are reduced by a factor of 30 in the sphere configuration. Measurements on streams in drinking water processes are also shown. This combination of two well known techniques offers the potential for highly reliable industrial process measurements, which would otherwise require pre-treatment using sub-micron filtration.
- 1 January 1999
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 10 (7) , 612-618
Non-contact, scattering-independent water absorption measurement using a falling stream and integrating sphere
We have applied an integrating sphere to the measurement of optical absorption in process waters containing high levels of scattering particles. The sphere greatly reduces the effects of scattering, which appear in a conventional transmission measurement as an apparent absorption. Additionally, the water sample flows through the sphere in the form of an unconstrained falling stream, allowing non-contact measurement and removing the fouling suffered by wetted cuvette windows. Using a 430 nm LED, silicon detector and 100 mm sphere, an absorbance resolution of approximately 0.01 has been demonstrated. Errors caused in a spectrometer measurement by levels of scattering contributing an apparent unit absorbance to a 0.2 absorbance dye solution are reduced by a factor of 30 in the sphere configuration. Measurements on streams in drinking water processes are also shown. This combination of two well known techniques offers the potential for highly reliable industrial process measurements, which would otherwise require pre-treatment using sub-micron filtration.
- 1 April 1997
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (7) , 1279-1284
Spectroscopic Detection of Aqueous Contaminants Using in Situ Corona Reactions
An apparently novel technique to aid the detection of a variety of inorganic and organic compounds in environmental and drinking water samples is described. Background absorbance due to optical scattering, cell fouling, and a variety of contaminants is suppressed by combining UV spectroscopy with chemical reactions initiated by reactive species generated in a high-voltage corona discharge. Injection of the reactive species takes place through a free water surface from the “corona wind”. Initial measurements on aqueous chlorine in drinking water and BTEX (benzene, toluene, ethylbenzene, and xylene) in unfiltered river water down to parts-per-million concentration are given which show, by comparison with a conventional UV absorption measurement, good background suppression. The experimental arrangement is simpler than that in typical fluorescence detection systems, and the geometrical flexibility means that corona “dosing” can be applied also to Raman and other spectroscopies, to electrochemical detection schemes, and to planar and windowless geometries.
- 1 April 1997
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 69 (7) , 1279-1284
Spectroscopic Detection of Aqueous Contaminants Using in Situ Corona Reactions
An apparently novel technique to aid the detection of a variety of inorganic and organic compounds in environmental and drinking water samples is described. Background absorbance due to optical scattering, cell fouling, and a variety of contaminants is suppressed by combining UV spectroscopy with chemical reactions initiated by reactive species generated in a high-voltage corona discharge. Injection of the reactive species takes place through a free water surface from the “corona wind”. Initial measurements on aqueous chlorine in drinking water and BTEX (benzene, toluene, ethylbenzene, and xylene) in unfiltered river water down to parts-per-million concentration are given which show, by comparison with a conventional UV absorption measurement, good background suppression. The experimental arrangement is simpler than that in typical fluorescence detection systems, and the geometrical flexibility means that corona “dosing” can be applied also to Raman and other spectroscopies, to electrochemical detection schemes, and to planar and windowless geometries.
- 1 January 1996
- Published by Optica Publishing Group
- p. CWH1
Corona-Wind Electro-Reagent Spectroscopy
Ultraviolet (UV) spectroscopy is an attractive detection technique for organics and other species in environmental water samples because of its potential for contactless measurement, and because of the low absorption of pure water. However, the low absolute absorptions of ppm-concentrations are difficult to resolve in the presence of high absorptions from a wide variety of benign species, such as the nitrate ion. Hence selectivity is the real problem.
- 1 January 1996
- Published by Optica Publishing Group
- p. CWH1
Corona-Wind Electro-Reagent Spectroscopy
Ultraviolet (UV) spectroscopy is an attractive detection technique for organics and other species in environmental water samples because of its potential for contactless measurement, and because of the low absorption of pure water. However, the low absolute absorptions of ppm-concentrations are difficult to resolve in the presence of high absorptions from a wide variety of benign species, such as the nitrate ion. Hence selectivity is the real problem.