Dominique Blin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Dominique Blin has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Olivier Chavanon
Department of Cardiac Surgery, Grenoble University Hospital, Grenoble, France
4 shared publications Alexandre Moreau-Gaudry
Département de Méthodologie et de l'Information de Santé, University Hospital Grenoble, Grenoble, France
2 shared publicationsChristelle Akret
CH Annecy, Annecy, France
1 shared publication- Françoise Stanke-Labesque
Laboratory of Pharmacology, Pharmacogenetics and Toxicology, Grenoble Alpes University Hospital, 38000 Grenoble, France
1 shared publication Frédéric Thony
Department of Interventional Radiology, Grenoble University Hospital, BP 217 Grenoble cedex 9, France
1 shared publicationGerald Vanzetto
CHU de Grenoble, unité de soins intensifs cardiologiques, Grenoble, France
1 shared publication
Latest Publications
- Open Access
- 7 May 2012
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 15 (2) , 294-296
Haemostasis of a right ventricle-gunshot wound using a novel haemostatic vacuum device
Heart wounds are frequently fatal. The haemorrhage from a right ventricle-gunshot wound in a male patient was successfully controlled using a novel haemostatic vacuum device. This case report shows how this simple, quick and efficient method can be used to control critical bleedings.
- 7 May 2012
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 15 (2) , 294-296
Open AccessHaemostasis of a right ventricle-gunshot wound using a novel haemostatic vacuum device
Heart wounds are frequently fatal. The haemorrhage from a right ventricle-gunshot wound in a male patient was successfully controlled using a novel haemostatic vacuum device. This case report shows how this simple, quick and efficient method can be used to control critical bleedings.
- 1 June 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 39 (6) , 1070-1072
An innovative technique to control bleeding with vacuum device
Bleeding is one of the major problems during surgery as well as in cases of accidental vascular injury. Control of bleeding can be life threatening in two surgical circumstances: when the wound is difficult to expose, and when the tissue too fragile to suture. Following more than 100 animal tests, we developed an innovative vacuum-based suction device, which enables us to address this challenge. We set up a proof-of-concept protocol in humans and report here our first clinical experience.
- 1 June 2011
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 39 (6) , 1070-1072
An innovative technique to control bleeding with vacuum device
Bleeding is one of the major problems during surgery as well as in cases of accidental vascular injury. Control of bleeding can be life threatening in two surgical circumstances: when the wound is difficult to expose, and when the tissue too fragile to suture. Following more than 100 animal tests, we developed an innovative vacuum-based suction device, which enables us to address this challenge. We set up a proof-of-concept protocol in humans and report here our first clinical experience.
- 31 January 2010
- Published by Elsevier in Archives of Cardiovascular Diseases Supplements
- Vol. 2 (1) , 111
337 Extra Corporeal Life Support: A hope in refractory cardiac cardiac arrest?
- 31 January 2010
- Published by Elsevier in Archives of Cardiovascular Diseases Supplements
- Vol. 2 (1) , 111
337 Extra Corporeal Life Support: A hope in refractory cardiac cardiac arrest?
- Open Access
- 1 August 2005
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 28 (2) , 340-342
Aortic arch embolization of an Amplatzer® occluder after an atrial septal defect closure: hybrid operative approach without circulatory arrest
Percutaneous closure of the secundum type atrial septal defects is becoming increasingly popular. We report the case of a 49-year-old man who presented for an unusual embolization of an Amplatzer® occluder (AO) 6 weeks after a percutaneous closure of his secundum type atrial septal defect. Emergency cardiac surgery was performed and the device was safely removed by a combined surgical and endovascular approach with no need of circulatory arrest or of profound hypothermia.
- 1 August 2005
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 28 (2) , 340-342
Open AccessAortic arch embolization of an Amplatzer® occluder after an atrial septal defect closure: hybrid operative approach without circulatory arrest
Percutaneous closure of the secundum type atrial septal defects is becoming increasingly popular. We report the case of a 49-year-old man who presented for an unusual embolization of an Amplatzer® occluder (AO) 6 weeks after a percutaneous closure of his secundum type atrial septal defect. Emergency cardiac surgery was performed and the device was safely removed by a combined surgical and endovascular approach with no need of circulatory arrest or of profound hypothermia.
- 1 September 1999
- Published by Georg Thieme Verlag KG in International Journal of Angiology
- Vol. 8 (04) , 187-192
Reactivity of the human internal mammary artery and the gastroepiploic artery to constrictor substances
The internal mammary artery (IMA) and the gastroepiploic artery (GEA) are frequently used to construct coronary artery bypass grafts. In order to determine and to compare their contractile properties, we studied the effects of constricting agents which are liberated or infused during coronary bypass surgery. IMA and GEA were arranged as ring segments and suspended in organ baths at optimal stretch using a normalization procedure. Concentration-contraction curves to angiotensin II, norepinephrine, U-46619, endothelin-1, leukotriene C4 and KCl were performed. The sensitivity (pD2) of GEA and IMA to all the agents did not differ. However, GEA developed stronger maximal contraction force than IMA to angiotensin II (P < 0.001), norepinephrine (P < 0.05), U-46619 (P=0.06), endothelin-1 (P < 0.01), and KCl (P < 0.01), whereas leukotriene C4 did not induce a significant contraction on GEA and IMA. The higher contractility of GEA may explain that it is more prone to spasm than IMA in the clinical setting. This study reinforces IMA as a first-choice conduit for coronary artery bypass and emphasizes the need for antispastic drugs particularly when GEA is used as bypass vessel.
- 1 September 1999
- Published by Georg Thieme Verlag KG in International Journal of Angiology
- Vol. 8 (04) , 187-192
Reactivity of the human internal mammary artery and the gastroepiploic artery to constrictor substances
The internal mammary artery (IMA) and the gastroepiploic artery (GEA) are frequently used to construct coronary artery bypass grafts. In order to determine and to compare their contractile properties, we studied the effects of constricting agents which are liberated or infused during coronary bypass surgery. IMA and GEA were arranged as ring segments and suspended in organ baths at optimal stretch using a normalization procedure. Concentration-contraction curves to angiotensin II, norepinephrine, U-46619, endothelin-1, leukotriene C4 and KCl were performed. The sensitivity (pD2) of GEA and IMA to all the agents did not differ. However, GEA developed stronger maximal contraction force than IMA to angiotensin II (P < 0.001), norepinephrine (P < 0.05), U-46619 (P=0.06), endothelin-1 (P < 0.01), and KCl (P < 0.01), whereas leukotriene C4 did not induce a significant contraction on GEA and IMA. The higher contractility of GEA may explain that it is more prone to spasm than IMA in the clinical setting. This study reinforces IMA as a first-choice conduit for coronary artery bypass and emphasizes the need for antispastic drugs particularly when GEA is used as bypass vessel.