Wiesław Hędzelek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wiesław Hędzelek has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Przemysław Gajdus
4 shared publicationsAdam Piosik
2 shared publicationsPrzemyslaw Gajdus
2 shared publicationsBartosz Leda
1 shared publication- Beata Czarnecka
Department of Biomaterials and Experimental Dentistry, Poznan University of Medical Sciences, 60-812 Poznan, Poland
1 shared publication Krystian Szumiński
1 shared publication
Latest Publications
- 14 December 2015
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 65 (6) , 528-539
The analysis of primary and secondary stability of implants with modified surfaces based on Osstell Mentor and Periotest S comparison: An animal study
- 14 December 2015
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 65 (6) , 528-539
The analysis of primary and secondary stability of implants with modified surfaces based on Osstell Mentor and Periotest S comparison: An animal study
- 14 February 2014
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 64 (1) , 11-18
Assessment of tension and intensity of electrogalvanic currents in patients’ oral cavity
- 14 February 2014
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 64 (1) , 11-18
Assessment of tension and intensity of electrogalvanic currents in patients’ oral cavity
- 13 December 2013
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 63 (6) , 441-449
Analysis of some mechanical proprieties of bar-connection supported on two implants: A preliminary examination
- 13 December 2013
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 63 (6) , 441-449
Analysis of some mechanical proprieties of bar-connection supported on two implants: A preliminary examination
- 13 December 2013
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 63 (6) , 459-465
Implementation of zirconia-based implant abutments in implant prosthodontics treatment. Part 1. A systematic review
- 13 December 2013
- Published by Termedia Sp. z.o.o. in Prosthodontics
- Vol. 63 (6) , 459-465
Implementation of zirconia-based implant abutments in implant prosthodontics treatment. Part 1. A systematic review
- 15 September 2010
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 38 (6) , 462-468
Evaluation of the retentive characteristics of semi-precision extracoronal attachments
The aims of this in vitro study were: to evaluate the repeatability of producing the semi-precision attachment; to establish their estimated longevity by a simulated, repeated denture placement/removal procedure of denture; and to investigate the wear of their components. Four types of semi-precision attachments were evaluated. The attachments represented polymer-to-metal type of friction: Vario-Kugel-Snap, Vario-Soft, Strategy OT and ASC-52, which exhibited metal-to-metal type of friction. Tensile dislodging force was applied to sample to register peak load-to-dislodgment and also to determine the displacement curve. Then the cyclic axial loading tests were performed with insertion/separation machine. To detect worn areas, the surface of each sample was examined under a scanning electron microscope. The large variability of initial retentive force and shape of displacement curves was noted within Vario-Soft and Vario-Kugel-Snap group. After the first period of loading (up to 300 cycles), the mechanical properties of all samples were stabilised. The mean retention force of attachments with polymer matrix after 3000 cycles was approximately half the recommended value, while samples of ASC-52 (with metal-to-metal friction) withstood 8000 cycles. Results suggest that the inaccuracies of casting and laboratory procedure have only limited influence on the fit of the semi-precision attachments. The attachment with metal-to-metal type of friction exhibits the highest wear resistance (simulated up to 8 years of usage) compared to attachments with polymeric matrix (up to 3 years). All attachments exhibited wear of metal patrix, what can minimise the chance of re-activation in a long run.
- 15 September 2010
- Published by Wiley in Journal of Oral Rehabilitation
- Vol. 38 (6) , 462-468
Evaluation of the retentive characteristics of semi-precision extracoronal attachments
The aims of this in vitro study were: to evaluate the repeatability of producing the semi-precision attachment; to establish their estimated longevity by a simulated, repeated denture placement/removal procedure of denture; and to investigate the wear of their components. Four types of semi-precision attachments were evaluated. The attachments represented polymer-to-metal type of friction: Vario-Kugel-Snap, Vario-Soft, Strategy OT and ASC-52, which exhibited metal-to-metal type of friction. Tensile dislodging force was applied to sample to register peak load-to-dislodgment and also to determine the displacement curve. Then the cyclic axial loading tests were performed with insertion/separation machine. To detect worn areas, the surface of each sample was examined under a scanning electron microscope. The large variability of initial retentive force and shape of displacement curves was noted within Vario-Soft and Vario-Kugel-Snap group. After the first period of loading (up to 300 cycles), the mechanical properties of all samples were stabilised. The mean retention force of attachments with polymer matrix after 3000 cycles was approximately half the recommended value, while samples of ASC-52 (with metal-to-metal friction) withstood 8000 cycles. Results suggest that the inaccuracies of casting and laboratory procedure have only limited influence on the fit of the semi-precision attachments. The attachment with metal-to-metal type of friction exhibits the highest wear resistance (simulated up to 8 years of usage) compared to attachments with polymeric matrix (up to 3 years). All attachments exhibited wear of metal patrix, what can minimise the chance of re-activation in a long run.
- 1 January 2010
- Published by Springer Nature
- p. 391-422
Tooth-Implant Life Cycle Design
- 22 June 2007
- Vol. 20 (3) , 311-2
Mechanical strength of an acrylic resin palatal denture base reinforced with a mesh or bundle of glass fibers.
The aim of this pilot study was to evaluate the mechanical strength of an acrylic resin palatal denture base reinforced with a mesh or bundle of glass fibers. Silicon and stone casts of an edentulous maxilla (Frasaco) were used to manufacture palatal denture bases (n = 20) using heat-polymerized acrylic resin (SR Triplex Hot). The denture bases were reinforced with either 1 or 3 layers of glass-fiber mesh (Stick Net) or with a bundle of unidirectional glass fibers (Stick). Denture bases without reinforcement served as the control group. Fracture tests were carried out on a universal testing machine to determine each material's mechanical strength. The highest mean fracture values of 919 N were obtained in samples with 3 layers of Stick Net, with mean values of 677 N in the control samples. The differences between these 2 groups were statistically significant (P < .05). The applied glass-fiber reinforcement increased the mechanical strength of the acrylic resin palatal denture bases.
- 22 June 2007
- Vol. 20 (3) , 311-2
Mechanical strength of an acrylic resin palatal denture base reinforced with a mesh or bundle of glass fibers.
The aim of this pilot study was to evaluate the mechanical strength of an acrylic resin palatal denture base reinforced with a mesh or bundle of glass fibers. Silicon and stone casts of an edentulous maxilla (Frasaco) were used to manufacture palatal denture bases (n = 20) using heat-polymerized acrylic resin (SR Triplex Hot). The denture bases were reinforced with either 1 or 3 layers of glass-fiber mesh (Stick Net) or with a bundle of unidirectional glass fibers (Stick). Denture bases without reinforcement served as the control group. Fracture tests were carried out on a universal testing machine to determine each material's mechanical strength. The highest mean fracture values of 919 N were obtained in samples with 3 layers of Stick Net, with mean values of 677 N in the control samples. The differences between these 2 groups were statistically significant (P < .05). The applied glass-fiber reinforcement increased the mechanical strength of the acrylic resin palatal denture bases.
- 11 April 2006
- Vol. 19 (2) , 193-4
Comparison of mechanical strength of palatal denture bases made from various plastic materials.
The aim of the study was to compare the mechanical strength of palatal denture bases made from various plastic materials. A form and models of an edentulous jaw (Frasaco) were used in the study. The denture bases were made from Zhermacryl H Plus and SR Ivocap Plus (both acrylic resins) and the polyurethane Microbase. Five samples were fabricated for each of the studied polymers. The fracture tests were carried out on a universal testing machine (Hounsfield H5KS). The highest fracture values were assessed on Ivocap specimens. The indicated differences between acrylic resin specimens made of Ivocap and Zhermacryl were not statistically significant. In turn, the differences shown between 2 acrylic resin palatal denture bases and the Microbase were statistically significant (P < .05). In this study, samples made from an alternative denture base polymer showed poorer mechanical strength as compared with those made of polymethylmethacrylate.
- 11 April 2006
- Vol. 19 (2) , 193-4
Comparison of mechanical strength of palatal denture bases made from various plastic materials.
The aim of the study was to compare the mechanical strength of palatal denture bases made from various plastic materials. A form and models of an edentulous jaw (Frasaco) were used in the study. The denture bases were made from Zhermacryl H Plus and SR Ivocap Plus (both acrylic resins) and the polyurethane Microbase. Five samples were fabricated for each of the studied polymers. The fracture tests were carried out on a universal testing machine (Hounsfield H5KS). The highest fracture values were assessed on Ivocap specimens. The indicated differences between acrylic resin specimens made of Ivocap and Zhermacryl were not statistically significant. In turn, the differences shown between 2 acrylic resin palatal denture bases and the Microbase were statistically significant (P < .05). In this study, samples made from an alternative denture base polymer showed poorer mechanical strength as compared with those made of polymethylmethacrylate.