Matteo Baldisserotto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Matteo Baldisserotto has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Matias Epifanio
Pontifícia Universidade Católica do Rio Grande do Sul
5 shared publications - Bruno Hochhegger
Department of Radiology, University of Florida, Gainesville, USA
4 shared publications - Edson Marchiori
Department of Radiology, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil
4 shared publications - Gabriel Sartori Pacini
Medical Imaging Research Lab, LABIMED, Department of Radiology, Pavilhão Pereira Filho Hospital, Irmandade Santa Casa de Misericórdia de Porto Alegre - Av, Independência, 75, Porto Alegre, 90020160, Brazil
3 shared publications - Guilherme Watte
Department of Respiratory Medicine and Thoracic Surgery, Irmandade da Santa Casa de Misericordia de Porto Alegre, R. Sarmento Leite, 245, Porto Alegre, 90050-170, Brazil
3 shared publications - Stephan Altmayer
Department of Radiology, Stanford University School of Medicine, Stanford, CA
3 shared publications
Latest Publications
- Open Access
- 1 January 2020
- Published by Elsevier in Jornal de Pediatria (Versão em Português)
- Vol. 96 (1) , 92-99
Ultra‐low‐dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases
- 1 January 2020
- Published by Elsevier in Jornal de Pediatria (Versão em Português)
- Vol. 96 (1) , 92-99
Open AccessUltra‐low‐dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases
- Open Access
- 1 December 2019
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 52 (6) , 361-367
Diffusion-weighted imaging and apparent diffusion coefficient values for evaluating terminal ileitis in patients with Crohn’s disease
Objective: To determine the accuracy of diffusion-weighted imaging (DWI) in identifying terminal ileitis in patients with Crohn’s disease. Materials and Methods: This was a retrospective study of 38 consecutive patients with Crohn’s disease who underwent magnetic resonance enterography with DWI in a 3.0 T scanner. The patients were divided into two groups, on the basis of colonoscopy and biopsy findings: active inflammation; and inactive disease. Apparent diffusion coefficient (ADC) values were determined, as were the magnetic resonance index of activity (MaRIA) and the Clermont score. Results: Of the 38 patients evaluated, 18 (47%) had active inflammation. The patients with active inflammation showed greater restricted diffusion, more pronounced mucosal edema, greater wall thickening, a higher MaRIA, and a higher Clermont score than did those with inactive disease. The level of interobserver agreement (intraclass correlation coefficient) was excellent for the MaRIA and the Clermont score, whereas it was substantial for the ADC values. For identifying colonoscopy-proven inflammation, the best ADC cut-off point was 2.1 × 10−3 mm2/s, which had a sensitivity of 88.8% and a specificity of 95.0%, whereas DWI presented an overall accuracy of 89.4%, with a sensitivity of 88.9% and a specificity of 90.0%. Conclusion: Visual analysis of the DWI sequence has good accuracy in detecting terminal ileitis in patients with Crohn’s disease. In addition, low ADC values have good sensitivity for detecting colonoscopy-proven inflammation.
- 1 December 2019
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 52 (6) , 361-367
Open AccessDiffusion-weighted imaging and apparent diffusion coefficient values for evaluating terminal ileitis in patients with Crohn’s disease
Objective: To determine the accuracy of diffusion-weighted imaging (DWI) in identifying terminal ileitis in patients with Crohn’s disease. Materials and Methods: This was a retrospective study of 38 consecutive patients with Crohn’s disease who underwent magnetic resonance enterography with DWI in a 3.0 T scanner. The patients were divided into two groups, on the basis of colonoscopy and biopsy findings: active inflammation; and inactive disease. Apparent diffusion coefficient (ADC) values were determined, as were the magnetic resonance index of activity (MaRIA) and the Clermont score. Results: Of the 38 patients evaluated, 18 (47%) had active inflammation. The patients with active inflammation showed greater restricted diffusion, more pronounced mucosal edema, greater wall thickening, a higher MaRIA, and a higher Clermont score than did those with inactive disease. The level of interobserver agreement (intraclass correlation coefficient) was excellent for the MaRIA and the Clermont score, whereas it was substantial for the ADC values. For identifying colonoscopy-proven inflammation, the best ADC cut-off point was 2.1 × 10−3 mm2/s, which had a sensitivity of 88.8% and a specificity of 95.0%, whereas DWI presented an overall accuracy of 89.4%, with a sensitivity of 88.9% and a specificity of 90.0%. Conclusion: Visual analysis of the DWI sequence has good accuracy in detecting terminal ileitis in patients with Crohn’s disease. In addition, low ADC values have good sensitivity for detecting colonoscopy-proven inflammation.
- 21 March 2019
- Published by Springer Nature in Lung
- Vol. 197 (3) , 259-265
Pulmonary Acinus: Understanding the Computed Tomography Findings from an Acinar Perspective
The lung acinus is the most distal portion of the airway responsible for the gas exchange. The normal acini are not visible on conventional computed tomography (CT), but the advent of micro-CT improved the understanding of the microarchitecture of healthy acini. The comprehension of the acinar architecture is pivotal for the understanding of CT findings of diseases that involve the acini. Centriacinar emphysema, for example, presents as round areas of low attenuation due to the destruction of the most central acini with compensatory enlargement of proximal acini due to alveolar wall destruction. In pulmonary fibrosis, intralobular septal fibrosis manifests as acinar wall thickening with an overlap of acinar collapse and compensatory dilation of surrounding acini constituting the cystic disease typical of the usual interstitial pneumonia pattern. This is a state-of-the-art review to describe the acinar structure from the micro-CT perspective and display how the comprehension of the acinar structure can aid in the interpretation of its microarchitecture disruption on conventional CT.
- 21 March 2019
- Published by Springer Nature in Lung
- Vol. 197 (3) , 259-265
Pulmonary Acinus: Understanding the Computed Tomography Findings from an Acinar Perspective
The lung acinus is the most distal portion of the airway responsible for the gas exchange. The normal acini are not visible on conventional computed tomography (CT), but the advent of micro-CT improved the understanding of the microarchitecture of healthy acini. The comprehension of the acinar architecture is pivotal for the understanding of CT findings of diseases that involve the acini. Centriacinar emphysema, for example, presents as round areas of low attenuation due to the destruction of the most central acini with compensatory enlargement of proximal acini due to alveolar wall destruction. In pulmonary fibrosis, intralobular septal fibrosis manifests as acinar wall thickening with an overlap of acinar collapse and compensatory dilation of surrounding acini constituting the cystic disease typical of the usual interstitial pneumonia pattern. This is a state-of-the-art review to describe the acinar structure from the micro-CT perspective and display how the comprehension of the acinar structure can aid in the interpretation of its microarchitecture disruption on conventional CT.
- Open Access
- 17 September 2018
- Published by Elsevier in Jornal de Pediatria
- Vol. 96 (1) , 92-99
Ultra-low-dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases
- 17 September 2018
- Published by Elsevier in Jornal de Pediatria
- Vol. 96 (1) , 92-99
Open AccessUltra-low-dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases
- Open Access
- 27 January 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (1) , e0167625
Quantification of Abdominal Fat in Obese and Healthy Adolescents Using 3 Tesla Magnetic Resonance Imaging and Free Software for Image Analysis
Computed tomography, which uses ionizing radiation and expensive software packages for analysis of scans, can be used to quantify abdominal fat. The objective of this study is to measure abdominal fat with 3T MRI using free software for image analysis and to correlate these findings with anthropometric and laboratory parameters in adolescents. This prospective observational study included 24 overweight/obese and 33 healthy adolescents (mean age 16.55 years). All participants underwent abdominal MRI exams. Visceral and subcutaneous fat area and percentage were correlated with anthropometric parameters, lipid profile, glucose metabolism, and insulin resistance. Student’s t test and Mann-Whitney’s test was applied. Pearson’s chi-square test was used to compare proportions. To determine associations Pearson’s linear correlation or Spearman’s correlation were used. In both groups, waist circumference (WC) was associated with visceral fat area (P = 0.001 and P = 0.01 respectively), and triglycerides were associated with fat percentage (P = 0.046 and P = 0.071 respectively). In obese individuals, total cholesterol/HDL ratio was associated with visceral fat area (P = 0.03) and percentage (P = 0.09), and insulin and HOMA-IR were associated with visceral fat area (P = 0.001) and percentage (P = 0.005). 3T MRI can provide reliable and good quality images for quantification of visceral and subcutaneous fat by using a free software package. The results demonstrate that WC is a good predictor of visceral fat in obese adolescents and visceral fat area is associated with total cholesterol/HDL ratio, insulin and HOMA-IR.
- 27 January 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (1) , e0167625
Open AccessQuantification of Abdominal Fat in Obese and Healthy Adolescents Using 3 Tesla Magnetic Resonance Imaging and Free Software for Image Analysis
Computed tomography, which uses ionizing radiation and expensive software packages for analysis of scans, can be used to quantify abdominal fat. The objective of this study is to measure abdominal fat with 3T MRI using free software for image analysis and to correlate these findings with anthropometric and laboratory parameters in adolescents. This prospective observational study included 24 overweight/obese and 33 healthy adolescents (mean age 16.55 years). All participants underwent abdominal MRI exams. Visceral and subcutaneous fat area and percentage were correlated with anthropometric parameters, lipid profile, glucose metabolism, and insulin resistance. Student’s t test and Mann-Whitney’s test was applied. Pearson’s chi-square test was used to compare proportions. To determine associations Pearson’s linear correlation or Spearman’s correlation were used. In both groups, waist circumference (WC) was associated with visceral fat area (P = 0.001 and P = 0.01 respectively), and triglycerides were associated with fat percentage (P = 0.046 and P = 0.071 respectively). In obese individuals, total cholesterol/HDL ratio was associated with visceral fat area (P = 0.03) and percentage (P = 0.09), and insulin and HOMA-IR were associated with visceral fat area (P = 0.001) and percentage (P = 0.005). 3T MRI can provide reliable and good quality images for quantification of visceral and subcutaneous fat by using a free software package. The results demonstrate that WC is a good predictor of visceral fat in obese adolescents and visceral fat area is associated with total cholesterol/HDL ratio, insulin and HOMA-IR.
- 1 September 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 280 (3) , 978-979
In Search of a Rational Protocol for the Diagnosis of Acute Appendicitis
- 1 September 2016
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 280 (3) , 978-979
In Search of a Rational Protocol for the Diagnosis of Acute Appendicitis
- 26 April 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (5) , 1354-1359
Validation of PI‐RADS v.2 for prostate cancer diagnosis with MRI at 3T using an external phased‐array coil
Purpose: To date, few studies have validated the Prostate Imaging Reporting and Data System Version 2 (PI‐RADS v. 2) for the diagnosis of prostate cancer. Our aim was to validate PI‐RADS v.2 using 3 Tesla (T) MRI.Materials and Methods: This is a retrospective study of 54 consecutive patients who underwent 3T MRI with a body‐array coil for diagnostic confirmation of prostate cancer or cancer staging between June 2013 and June 2015. Sensitivity, specificity, and agreement were calculated based on a criterion of PI‐RADS score = 3. Inter‐examiner agreement was determined by the weighted kappa statistic.Results: Histological findings were positive for cancer in 33 patients and negative in 21 patients. Considering a PI‐RADS score of 3 as positive for cancer, the accuracy of each reader was 85.20% and 70.40%, respectively, and agreement coefficients were κ = 0.69 and κ = 0.35. Considering PI‐RADS 3 as absence of cancer, the accuracy of each reader was 77.80% and 77.80%, respectively, and agreement was κ = 0.55 and κ = 0.54. Inter‐reader agreement was moderate/good (weighted κ = 0.53; 95% confidence interval: 0.39–0.66; P = 0.038).Conclusion: High accuracy was obtained for the diagnosis of prostate cancer using 3T MRI with a body coil and the PI‐RADS v.2 score. J. Magn. Reson. Imaging 2016;44:1354–1359.
- 26 April 2016
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 44 (5) , 1354-1359
Validation of PI‐RADS v.2 for prostate cancer diagnosis with MRI at 3T using an external phased‐array coil
Purpose: To date, few studies have validated the Prostate Imaging Reporting and Data System Version 2 (PI‐RADS v. 2) for the diagnosis of prostate cancer. Our aim was to validate PI‐RADS v.2 using 3 Tesla (T) MRI.Materials and Methods: This is a retrospective study of 54 consecutive patients who underwent 3T MRI with a body‐array coil for diagnostic confirmation of prostate cancer or cancer staging between June 2013 and June 2015. Sensitivity, specificity, and agreement were calculated based on a criterion of PI‐RADS score = 3. Inter‐examiner agreement was determined by the weighted kappa statistic.Results: Histological findings were positive for cancer in 33 patients and negative in 21 patients. Considering a PI‐RADS score of 3 as positive for cancer, the accuracy of each reader was 85.20% and 70.40%, respectively, and agreement coefficients were κ = 0.69 and κ = 0.35. Considering PI‐RADS 3 as absence of cancer, the accuracy of each reader was 77.80% and 77.80%, respectively, and agreement was κ = 0.55 and κ = 0.54. Inter‐reader agreement was moderate/good (weighted κ = 0.53; 95% confidence interval: 0.39–0.66; P = 0.038).Conclusion: High accuracy was obtained for the diagnosis of prostate cancer using 3T MRI with a body coil and the PI‐RADS v.2 score. J. Magn. Reson. Imaging 2016;44:1354–1359.
- Open Access
- 1 October 2014
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 59 (4) , e37
Appendiceal Intussusception
- 1 October 2014
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 59 (4) , e37
Open AccessAppendiceal Intussusception
- Open Access
- 1 November 2013
- Published by Elsevier in Jornal de Pediatria (Versão em Português)
- Vol. 89 (6) , 554-558
Cow's milk allergy: color Doppler ultrasound findings in infants with hematochezia
- 1 November 2013
- Published by Elsevier in Jornal de Pediatria (Versão em Português)
- Vol. 89 (6) , 554-558
Open AccessCow's milk allergy: color Doppler ultrasound findings in infants with hematochezia
- 1 April 2013
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 19 (3) , 144-147
A Low Cost Method of Digitizing Radiographs Using a Photo Light Box
We evaluated a low cost device for digitizing X-ray films. It consisted of a locally-made wooden box and a readily-available digital camera. Two experienced paediatric radiologists interpreted the original X-ray films (the reference standard) and the corresponding images obtained in the photo light box. Ninety paediatric chest X-ray films were used (30 were normal chest radiographs, 30 showed pneumonic-consolidation and 30 had interstitial infiltrates). The presence or absence of the three signs most frequently found in acute respiratory pathologies were evaluated: normal pulmonary transparency, pneumonic consolidation and interstitial infiltration. There was very good agreement between the X-ray films and the digitized images, with kappa values from 0.86 to 0.98. There was good agreement between the two observers, with kappa values from 0.67 to 0.90. The low-cost photo light box represents an accessible and low-cost approach to transmitting X-ray images, allowing findings or a second opinion from a specialist radiologist to be obtained from a distance.
- 1 April 2013
- Published by SAGE Publications in Journal of Telemedicine and Telecare
- Vol. 19 (3) , 144-147
A Low Cost Method of Digitizing Radiographs Using a Photo Light Box
We evaluated a low cost device for digitizing X-ray films. It consisted of a locally-made wooden box and a readily-available digital camera. Two experienced paediatric radiologists interpreted the original X-ray films (the reference standard) and the corresponding images obtained in the photo light box. Ninety paediatric chest X-ray films were used (30 were normal chest radiographs, 30 showed pneumonic-consolidation and 30 had interstitial infiltrates). The presence or absence of the three signs most frequently found in acute respiratory pathologies were evaluated: normal pulmonary transparency, pneumonic consolidation and interstitial infiltration. There was very good agreement between the X-ray films and the digitized images, with kappa values from 0.86 to 0.98. There was good agreement between the two observers, with kappa values from 0.67 to 0.90. The low-cost photo light box represents an accessible and low-cost approach to transmitting X-ray images, allowing findings or a second opinion from a specialist radiologist to be obtained from a distance.