Celso Darío Ramos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Celso Darío Ramos has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Elba Etchebehere
Division of Nuclear Medicine, University of Campinas (UNICAMP), Campinas, Brazil
2 shared publications A B Teixeira
Department of Radiology, Campinas State University, Brazil
1 shared publication- Allan Oliveira Santos
Universidade Estadual de Campinas, Brazil
1 shared publication Cleide Aparecida Moreira Silva
Campinas State University
1 shared publicationDenise Engelbrecht Zantut Wittmann
Campinas State University
1 shared publicationE E Camargo
1 shared publication
Latest Publications
- Open Access
- 1 March 2002
- Published by FapUNIFESP (SciELO) in Sao Paulo Medical Journal
- Vol. 120 (2) , 45-48
Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals
CONTEXT: Thyroid uptake and scintigraphy using 99mTc-pertechnetate has proven to be more advantageous than with 131I-iodide, since the images have better quality, the procedure is faster and the patient is submitted to a lower radiation dose. OBJECTIVE: The purpose of this study was to standardize a simple and fast methodology for performing thyroid uptake and scintigraphy and to determine the normal values for 99mTc- pertechnetate uptake. TYPE OF STUDY: Prospective, non-randomized. SETTING: Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas State University. PARTICIPANTS: The study consisted of 47 normal individuals, 30 women and 17 men, with ages ranging from 19 to 61 years (mean of 33 years). PROCEDURES: The laboratory assessment of thyroid function consisted of serum dosages of ultra-sensitive thyroxin and thyrotrophin. Twenty minutes after an intravenous injection of 10 mCi (370 MBq) of 99mTc-pertechnetate, the images were obtained on a computerized scintillation camera equipped with a low-energy high-resolution parallel hole collimator. RESULTS: All the individuals were euthyroid both on clinical and laboratory evaluation. The baseline thyroid 99mTc-pertechnetate uptake ranged from 0.4 to 1.7%. The uptake values obtained in these normal individuals showed that 95% presented a thyroid uptake that ranged from 0.4 to 1.5% of the injected dose. CONCLUSION: The assessment of thyroid structure and function using 99mTc-pertechnetate is a simple, fast and efficient method, which could easily become a part of the routine studies in nuclear medicine laboratories.
- 1 March 2002
- Published by FapUNIFESP (SciELO) in Sao Paulo Medical Journal
- Vol. 120 (2) , 45-48
Open AccessThyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals
CONTEXT: Thyroid uptake and scintigraphy using 99mTc-pertechnetate has proven to be more advantageous than with 131I-iodide, since the images have better quality, the procedure is faster and the patient is submitted to a lower radiation dose. OBJECTIVE: The purpose of this study was to standardize a simple and fast methodology for performing thyroid uptake and scintigraphy and to determine the normal values for 99mTc- pertechnetate uptake. TYPE OF STUDY: Prospective, non-randomized. SETTING: Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas State University. PARTICIPANTS: The study consisted of 47 normal individuals, 30 women and 17 men, with ages ranging from 19 to 61 years (mean of 33 years). PROCEDURES: The laboratory assessment of thyroid function consisted of serum dosages of ultra-sensitive thyroxin and thyrotrophin. Twenty minutes after an intravenous injection of 10 mCi (370 MBq) of 99mTc-pertechnetate, the images were obtained on a computerized scintillation camera equipped with a low-energy high-resolution parallel hole collimator. RESULTS: All the individuals were euthyroid both on clinical and laboratory evaluation. The baseline thyroid 99mTc-pertechnetate uptake ranged from 0.4 to 1.7%. The uptake values obtained in these normal individuals showed that 95% presented a thyroid uptake that ranged from 0.4 to 1.5% of the injected dose. CONCLUSION: The assessment of thyroid structure and function using 99mTc-pertechnetate is a simple, fast and efficient method, which could easily become a part of the routine studies in nuclear medicine laboratories.
- 1 March 2001
- Published by Rockefeller University Press
- Vol. 26 (3) , 193-7
Incidental focal thyroid uptake on FDG positron emission tomographic scans may represent a second primary tumor.
This article discusses the value of incidental thyroid uptake of fluorodeoxyglucose (FDG) on whole-body positron emission tomography (PET) scans performed in patients with cancer. This issue has been reported diversely in the literature. Whole-body PET scans of four patients with cancer (two of them women; age, 49 to 78 years) in whom focal thyroid uptake was visualized and subsequently correlated with thyroid carcinoma based on cytologic or histopathologic data were reviewed. The clinical outcomes of these patients were analyzed retrospectively. Maximum and average standardized uptake values (SUVs) of thyroid accumulation were recalculated in all patients. Two of the four patients referred for FDG PET scans had lung adenocarcinomas, one had prostate carcinoma, and one had an unknown primary tumor. Focal thyroid uptake was visualized, with maximum and average SUVs ranging from 3.7 and 2.3 to 53 and 34, respectively. These findings were correlated with cytologic (two patients) or histopathologic data (two patients) that indicated thyroid carcinoma. In two patients, their treatment was changed and total thyroidectomy was performed; in one of them the SUVs of the focal thyroid accumulation (maximum and average values of 7.9 and 4.8, respectively) were less than the cutoff values for thyroid cancer noted in the literature. The clinical condition of the other two patients did not permit additional investigation or treatment for thyroid carcinoma. Increased focal thyroid uptake on whole-body FDG PET scans should not be overlooked, even when it is not marked, and should prompt further investigation to rule out cancer.
- 1 March 2001
- Published by Rockefeller University Press
- Vol. 26 (3) , 193-7
Incidental focal thyroid uptake on FDG positron emission tomographic scans may represent a second primary tumor.
This article discusses the value of incidental thyroid uptake of fluorodeoxyglucose (FDG) on whole-body positron emission tomography (PET) scans performed in patients with cancer. This issue has been reported diversely in the literature. Whole-body PET scans of four patients with cancer (two of them women; age, 49 to 78 years) in whom focal thyroid uptake was visualized and subsequently correlated with thyroid carcinoma based on cytologic or histopathologic data were reviewed. The clinical outcomes of these patients were analyzed retrospectively. Maximum and average standardized uptake values (SUVs) of thyroid accumulation were recalculated in all patients. Two of the four patients referred for FDG PET scans had lung adenocarcinomas, one had prostate carcinoma, and one had an unknown primary tumor. Focal thyroid uptake was visualized, with maximum and average SUVs ranging from 3.7 and 2.3 to 53 and 34, respectively. These findings were correlated with cytologic (two patients) or histopathologic data (two patients) that indicated thyroid carcinoma. In two patients, their treatment was changed and total thyroidectomy was performed; in one of them the SUVs of the focal thyroid accumulation (maximum and average values of 7.9 and 4.8, respectively) were less than the cutoff values for thyroid cancer noted in the literature. The clinical condition of the other two patients did not permit additional investigation or treatment for thyroid carcinoma. Increased focal thyroid uptake on whole-body FDG PET scans should not be overlooked, even when it is not marked, and should prompt further investigation to rule out cancer.
- 1 February 2001
- Published by Rockefeller University Press
- Vol. 26 (2) , 162
Scintigraphic findings of dysplasia epiphysealis hemimelica: a case report.
- 1 February 2001
- Published by Rockefeller University Press
- Vol. 26 (2) , 162
Scintigraphic findings of dysplasia epiphysealis hemimelica: a case report.
- 1 February 2001
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 28 (2) , 155-164
FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection
Filtered back-projection (FBP) is the most commonly used reconstruction method for PET images, which are usually noisy. The iterative reconstruction segmented attenuation correction (IRSAC) algorithm improves image quality without reducing image resolution. The standardized uptake value (SUV) is the most clinically utilized quantitative parameter of [fluorine-18]fluoro-2-deoxy-D-glucose (FDG) accumulation. The objective of this study was to obtain a table of SUVs for several normal anatomical structures from both routinely used FBP and IRSAC reconstructed images and to compare the data obtained with both methods. Twenty whole-body PET scans performed in consecutive patients with proven or suspected non-small cell lung cancer were retrospectively analyzed. Images were processed using both IRSAC and FBP algorithms. Nonquantitative or gaussian filters were used to smooth the transmission scan when using FBP or IRSAC algorithms, respectively. A phantom study was performed to evaluate the effect of different filters on SUV. Maximum and average SUVs (SUVmax and SUVavg) were calculated in 28 normal anatomical structures and in one pathological site. The phantom study showed that the use of a nonquantitative smoothing filter in the transmission scan results in a less accurate quantification and in a 20% underestimation of the actual measurement. Most anatomical structures were identified in all patients using the IRSAC images. On average, SUVavg and SUVmax measured on IRSAC images using a gaussian filter in the transmission scan were respectively 20% and 8% higher than the SUVs calculated from conventional FBP images. Scatterplots of the data values showed an overall strong relationship between IRSAC and FBP SUVs. Individual scatterplots of each site demonstrated a weaker relationship for lower SUVs and for SUVmax than for higher SUVs and SUVavg. A set of reference values was obtained for SUVmax and SUVavg of normal anatomical structures, calculated with both IRSAC and FBP image reconstruction algorithms. The use of IRSAC and a gaussian filter for the transmission scan seems to give more accurate SUVs than are obtained from conventional FBP images using a nonquantitative filter for the transmission scan.
- 1 February 2001
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 28 (2) , 155-164
FDG-PET standardized uptake values in normal anatomical structures using iterative reconstruction segmented attenuation correction and filtered back-projection
Filtered back-projection (FBP) is the most commonly used reconstruction method for PET images, which are usually noisy. The iterative reconstruction segmented attenuation correction (IRSAC) algorithm improves image quality without reducing image resolution. The standardized uptake value (SUV) is the most clinically utilized quantitative parameter of [fluorine-18]fluoro-2-deoxy-D-glucose (FDG) accumulation. The objective of this study was to obtain a table of SUVs for several normal anatomical structures from both routinely used FBP and IRSAC reconstructed images and to compare the data obtained with both methods. Twenty whole-body PET scans performed in consecutive patients with proven or suspected non-small cell lung cancer were retrospectively analyzed. Images were processed using both IRSAC and FBP algorithms. Nonquantitative or gaussian filters were used to smooth the transmission scan when using FBP or IRSAC algorithms, respectively. A phantom study was performed to evaluate the effect of different filters on SUV. Maximum and average SUVs (SUVmax and SUVavg) were calculated in 28 normal anatomical structures and in one pathological site. The phantom study showed that the use of a nonquantitative smoothing filter in the transmission scan results in a less accurate quantification and in a 20% underestimation of the actual measurement. Most anatomical structures were identified in all patients using the IRSAC images. On average, SUVavg and SUVmax measured on IRSAC images using a gaussian filter in the transmission scan were respectively 20% and 8% higher than the SUVs calculated from conventional FBP images. Scatterplots of the data values showed an overall strong relationship between IRSAC and FBP SUVs. Individual scatterplots of each site demonstrated a weaker relationship for lower SUVs and for SUVmax than for higher SUVs and SUVavg. A set of reference values was obtained for SUVmax and SUVavg of normal anatomical structures, calculated with both IRSAC and FBP image reconstruction algorithms. The use of IRSAC and a gaussian filter for the transmission scan seems to give more accurate SUVs than are obtained from conventional FBP images using a nonquantitative filter for the transmission scan.