Carlos Alberto Baldan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Carlos Alberto Baldan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Yujiro Shigue
University of São Paulo
7 shared publications - Ernesto Ruppert Filho
School of Electrical and Computer Engineering, University of Campinas, Campinas, Brazil
4 shared publications - Andre Avancini Bernardes
Department of Metallurgical and Materials Engineering Escola Politécnica – Universidade de São Paulo São Paulo Brazil
3 shared publications - Ivani de Souza Bott2 shared publications
- Jefferson Fabrício Cardoso Lins
Universidade Federal Fluminense, Brazil
2 shared publications Jérika S. Lamas
Department of Solid State Sciences, Ghent University, Ghent, Belgium
2 shared publications
Latest Publications
- 20 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Electrical and Thermal Characterization of YBCO Coated Conductors for Resistive Fault Current Limiter Applications
Electrical and thermal characteristics of Yttrium Barium Copper Oxide (YBCO) coated conductors (CCs) with different architectures, with and without stabilizer layers, in resistive fault current limiters (RSFCLs) have been widely studied. In this study, the recovery of the superconducting state under different conditions (no-load and under load) is analyzed for subsequent fault current limitation. Test of modular RSFCL using commercial coated conductor with and without the assistance of an air-core power reactor was carried out. Shunt-assisted quench tests were investigated and measurements have been performed in short samples employed in the construction of modular unit with 6 stacks of 0.7-m length of 12-mm width YBCO CC tapes. Using the pulsed current method (PCM), the quench current (from Ic up to 3 × Ic) for a time period from 16.6 to 80 ms was applied to evaluate the temperature and recovery time, by the power losses, generated after the second quench in sequence. The RSFCL operates in a distribution grid protected by a recloser switch with intervals of 300 ms, 900 ms, and 1.2 s. For these time intervals, it is necessary to verify if full recovery behavior happens.
- 20 January 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 25 (3) , 1-4
Electrical and Thermal Characterization of YBCO Coated Conductors for Resistive Fault Current Limiter Applications
Electrical and thermal characteristics of Yttrium Barium Copper Oxide (YBCO) coated conductors (CCs) with different architectures, with and without stabilizer layers, in resistive fault current limiters (RSFCLs) have been widely studied. In this study, the recovery of the superconducting state under different conditions (no-load and under load) is analyzed for subsequent fault current limitation. Test of modular RSFCL using commercial coated conductor with and without the assistance of an air-core power reactor was carried out. Shunt-assisted quench tests were investigated and measurements have been performed in short samples employed in the construction of modular unit with 6 stacks of 0.7-m length of 12-mm width YBCO CC tapes. Using the pulsed current method (PCM), the quench current (from Ic up to 3 × Ic) for a time period from 16.6 to 80 ms was applied to evaluate the temperature and recovery time, by the power losses, generated after the second quench in sequence. The RSFCL operates in a distribution grid protected by a recloser switch with intervals of 300 ms, 900 ms, and 1.2 s. For these time intervals, it is necessary to verify if full recovery behavior happens.
- 21 February 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 5603804
Fault Current Limiter Using Transformer and Modular Device of YBCO Coated Conductor
In this work, we report on the evaluation of a superconducting fault current limiter (SFCL). It is consisted of a modular superconducting device combined with a short-circuited transformer with a primary copper winding connected in series to the power line and the secondary side short-circuited by the superconducting device. The basic idea is adding a magnetic component to contribute to the current limitation by the impedance reflected to the line after transition of the superconducting device. The evaluation tests were performed with a prospective current up to 2 kA, with the short-circuited transformer of 2.5 kVA, 220 V/660 V connected to a test facility of 100 kVA power capacity. The resistive SFCL using a modular superconducting device was tested without degradation for a prospective fault current of 1.8 kA, achieving the limiting factor 2.78; the voltage achieved 282 V corresponding to an electric field of 11 V/m. The test performed with the combined SFCL ( superconducting device + transformer) using series and toroidal transformers showed current limiting factor of 3.1 and 2 times, respectively. The test results of the combined SFCL with short-circuited transformer showed undesirable influence of the transformer impedance, resulting in reduction of the fault current level.
- 21 February 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 23 (3) , 5603804
Fault Current Limiter Using Transformer and Modular Device of YBCO Coated Conductor
In this work, we report on the evaluation of a superconducting fault current limiter (SFCL). It is consisted of a modular superconducting device combined with a short-circuited transformer with a primary copper winding connected in series to the power line and the secondary side short-circuited by the superconducting device. The basic idea is adding a magnetic component to contribute to the current limitation by the impedance reflected to the line after transition of the superconducting device. The evaluation tests were performed with a prospective current up to 2 kA, with the short-circuited transformer of 2.5 kVA, 220 V/660 V connected to a test facility of 100 kVA power capacity. The resistive SFCL using a modular superconducting device was tested without degradation for a prospective fault current of 1.8 kA, achieving the limiting factor 2.78; the voltage achieved 282 V corresponding to an electric field of 11 V/m. The test performed with the combined SFCL ( superconducting device + transformer) using series and toroidal transformers showed current limiting factor of 3.1 and 2 times, respectively. The test results of the combined SFCL with short-circuited transformer showed undesirable influence of the transformer impedance, resulting in reduction of the fault current level.
- 16 January 2013
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 26 (5) , 2089-2092
Electrical and Superconducting Properties in Lap Joints for YBCO Tapes
- 16 January 2013
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 26 (5) , 2089-2092
Electrical and Superconducting Properties in Lap Joints for YBCO Tapes
- 20 December 2012
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 26 (4) , 1241-1245
Prototype Fault Current Limiter Using Transformer and a Modular Device of YBCO Coated Conductor
- 20 December 2012
- Published by Springer Nature in Journal of Superconductivity and Novel Magnetism
- Vol. 26 (4) , 1241-1245
Prototype Fault Current Limiter Using Transformer and a Modular Device of YBCO Coated Conductor
- 13 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1242-1245
Test of a Modular Fault Current Limiter for 220 V Line Using YBCO Coated Conductor Tapes With Shunt Protection
A modular superconducting fault current limiter (SFCL) consisting of 16 elements was constructed and tested in a 220 V line for a fault current between 1 kA to 7.4 kA. The elements are made up of second generation (2G) YBCO-coated conductor tapes with stainless steel reinforcement. For each element four tapes were electrically connected in parallel with effective length of 0.4 m per element, totaling 16 elements connected in series. The evaluation of SFCL performance was carried out under DC and AC tests. The DC test was performed through pulsed current tests and its recovery characteristics under load current were analysed by changing the shunt resistor value. The AC test performed using a 3 MVA/220 V/60 Hz transformer has shown the current limiting ratio achieved a factor higher than 10 during fault of up to five cycles without conductor degradation. The measurement of the voltage for each element during the AC test showed that in this modular SFCL the quench is homogeneous and the transition occurs similarly in all the elements.
- 13 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 21 (3) , 1242-1245
Test of a Modular Fault Current Limiter for 220 V Line Using YBCO Coated Conductor Tapes With Shunt Protection
A modular superconducting fault current limiter (SFCL) consisting of 16 elements was constructed and tested in a 220 V line for a fault current between 1 kA to 7.4 kA. The elements are made up of second generation (2G) YBCO-coated conductor tapes with stainless steel reinforcement. For each element four tapes were electrically connected in parallel with effective length of 0.4 m per element, totaling 16 elements connected in series. The evaluation of SFCL performance was carried out under DC and AC tests. The DC test was performed through pulsed current tests and its recovery characteristics under load current were analysed by changing the shunt resistor value. The AC test performed using a 3 MVA/220 V/60 Hz transformer has shown the current limiting ratio achieved a factor higher than 10 during fault of up to five cycles without conductor degradation. The measurement of the voltage for each element during the AC test showed that in this modular SFCL the quench is homogeneous and the transition occurs similarly in all the elements.
- Open Access
- 1 August 2009
- Published by Editora Edgard Blucher, Ltda.
- Vol. 64 (64) , 309-322
AVALIAÇÃO DA CINÉTICA DE RECRISTALIZAÇÃO DE UM AÇO MICROLIGADO AO NIÓBIO PROCESSADO VIA ARB E RECOZIDO DA 600oC
PDF | Este trabalho teve por objetivo reportar a cinética de recristalização de um aço microligado estabilizado ao nióbio processado via ARB e posteriormente recozido a 600oC por meio do modelo cinético Johnson, Mehl, Avrami e Kolmogorov (JMAK). O processo foi conduzido num único ciclo de deformação a 500°C. A etapa de recozimento foi realizada a 600oC entre 5 min e 60 min. A caracterização microestrutural das amostras utilizou as técnicas de MO e metalografia quantitativa. Concluiu-se que o modelo cinético Johnson, Mehl, Avrami e Kolmogorov (JMAK) não indicou a forma de nucleação da recristalização para o aço microligado deformado severamente.
- 1 August 2009
- Published by Editora Edgard Blucher, Ltda.
- Vol. 64 (64) , 309-322
Open AccessAVALIAÇÃO DA CINÉTICA DE RECRISTALIZAÇÃO DE UM AÇO MICROLIGADO AO NIÓBIO PROCESSADO VIA ARB E RECOZIDO DA 600oC
PDF | Este trabalho teve por objetivo reportar a cinética de recristalização de um aço microligado estabilizado ao nióbio processado via ARB e posteriormente recozido a 600oC por meio do modelo cinético Johnson, Mehl, Avrami e Kolmogorov (JMAK). O processo foi conduzido num único ciclo de deformação a 500°C. A etapa de recozimento foi realizada a 600oC entre 5 min e 60 min. A caracterização microestrutural das amostras utilizou as técnicas de MO e metalografia quantitativa. Concluiu-se que o modelo cinético Johnson, Mehl, Avrami e Kolmogorov (JMAK) não indicou a forma de nucleação da recristalização para o aço microligado deformado severamente.
- 5 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 1810-1813
Fault Current Limiter Using YBCO Coated Conductor—The Limiting Factor and Its Recovery Time
A fault current limiter (FCL) based on an arrangement of parallel connected high temperature superconducting tapes constituting a limiter element was designed and tested in 220 V line for a fault current peak between 1 kA to 2 kA. The limiter employed second generation (2G) HTS tapes of YBCO coated conductor reinforced with stainless steel. Four tapes were electrically connected in parallel with 0.4 m effective length per element wherein 16 elements connected in series constitutes a single-phase unit. The FCL performance was evaluated through over-current and current fault tests. Its recovery characteristics were used to design the shunt protection. The designed limiting ratio is 4 for 16 elements and the experimental result for one element showed a 20% limiting ratio. For the fault current test one element can withstand five cycles of fault without degradation. It was observed recovery times below 0.5 s under nominal load using a shunt resistance of 173 mOmega.
- 5 June 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 19 (3) , 1810-1813
Fault Current Limiter Using YBCO Coated Conductor—The Limiting Factor and Its Recovery Time
A fault current limiter (FCL) based on an arrangement of parallel connected high temperature superconducting tapes constituting a limiter element was designed and tested in 220 V line for a fault current peak between 1 kA to 2 kA. The limiter employed second generation (2G) HTS tapes of YBCO coated conductor reinforced with stainless steel. Four tapes were electrically connected in parallel with 0.4 m effective length per element wherein 16 elements connected in series constitutes a single-phase unit. The FCL performance was evaluated through over-current and current fault tests. Its recovery characteristics were used to design the shunt protection. The designed limiting ratio is 4 for 16 elements and the experimental result for one element showed a 20% limiting ratio. For the fault current test one element can withstand five cycles of fault without degradation. It was observed recovery times below 0.5 s under nominal load using a shunt resistance of 173 mOmega.
- Open Access
- 1 August 2008
- Published by Editora Edgard Blucher, Ltda.
- Vol. 63 (63) , 3032-3041
CARACTERIZAÇÃO MICROESTRUTURAL DE UM AÇO MICROLIGADO AO NIÓBIO PROCESSADO VIA ARB E POSTERIORMENTE RECOZIDO A 600oC
PDF | Este trabalho teve por objetivo reportar a evolução da microestrutura de um aço microligado estabilizado ao nióbio processado via ARB e posteriormente recozido. O processo foi conduzido num único ciclo de deformação a 500 °C. A etapa de recozimento foi realizada a 600 oC entre 5 e 60 min. A caracterização microestrutural das amostras utilizou as técnicas de MO, MEV e dureza Vickers. O material deformado apresentou uma microestrutura bastante refinada devido à presença de ferrita acicular e bainita.
- 1 August 2008
- Published by Editora Edgard Blucher, Ltda.
- Vol. 63 (63) , 3032-3041
Open AccessCARACTERIZAÇÃO MICROESTRUTURAL DE UM AÇO MICROLIGADO AO NIÓBIO PROCESSADO VIA ARB E POSTERIORMENTE RECOZIDO A 600oC
PDF | Este trabalho teve por objetivo reportar a evolução da microestrutura de um aço microligado estabilizado ao nióbio processado via ARB e posteriormente recozido. O processo foi conduzido num único ciclo de deformação a 500 °C. A etapa de recozimento foi realizada a 600 oC entre 5 e 60 min. A caracterização microestrutural das amostras utilizou as técnicas de MO, MEV e dureza Vickers. O material deformado apresentou uma microestrutura bastante refinada devido à presença de ferrita acicular e bainita.
- 1 March 2007
- Published by FapUNIFESP (SciELO) in Rem: Revista Escola de Minas
- Vol. 60 (1) , 117-122
Recristalização do aço AISI 430 com estrutura colunar de grãos
O recozimento de materiais com grãos grosseiros permite observar importantes efeitos de orientação na recristalização. Amostras do aço inoxidável ferrítico AISI 430 estabilizado ao nióbio e com estrutura colunar de grãos foram deformadas até reduções de 50 e 80% e recozidas em temperaturas variando de 300 a 1100°C para avaliação do amolecimento e da cinética de recristalização. As amostras compreendem a seção longitudinal de uma placa obtida via lingotamento contínuo. A laminação foi realizada a morno (» 480°C), numa configuração na qual os grãos colunares permaneceram alinhados com a direção normal (contornos de grão paralelos à DN). A caracterização microestrutural das amostras utilizou microscopia eletrônica de varredura (MEV) no modo de elétrons retroespalhados. Os resultados mostram que o tamanho de grão recristalizado varia localmente de região para região, indicando efeitos de orientação importantes.
- 1 March 2007
- Published by FapUNIFESP (SciELO) in Rem: Revista Escola de Minas
- Vol. 60 (1) , 117-122
Recristalização do aço AISI 430 com estrutura colunar de grãos
O recozimento de materiais com grãos grosseiros permite observar importantes efeitos de orientação na recristalização. Amostras do aço inoxidável ferrítico AISI 430 estabilizado ao nióbio e com estrutura colunar de grãos foram deformadas até reduções de 50 e 80% e recozidas em temperaturas variando de 300 a 1100°C para avaliação do amolecimento e da cinética de recristalização. As amostras compreendem a seção longitudinal de uma placa obtida via lingotamento contínuo. A laminação foi realizada a morno (» 480°C), numa configuração na qual os grãos colunares permaneceram alinhados com a direção normal (contornos de grão paralelos à DN). A caracterização microestrutural das amostras utilizou microscopia eletrônica de varredura (MEV) no modo de elétrons retroespalhados. Os resultados mostram que o tamanho de grão recristalizado varia localmente de região para região, indicando efeitos de orientação importantes.
- 1 July 1994
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 30 (4) , 1931-1933
Design and test of a 7 T split-pair magnet for magnetic separation
- 1 July 1994
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 30 (4) , 1931-1933
Design and test of a 7 T split-pair magnet for magnetic separation