Nicolas Cézard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nicolas Cézard has a total of 59 co-authors. Here are the top co-authors by number of shared publications:
Agnès Dolfi-Bouteyre
ONERA/DOTA, Université de Paris-Saclay, F- 91120 Palaiseau, France
6 shared publicationsDidier Goular
ONERA/DOTA, Université de Paris-Saclay, F- 91120 Palaiseau, France
5 shared publications- Julien Lahyani
ONERA/DOTA, Université de Paris-Saclay, F- 91120 Palaiseau, France
5 shared publications Christophe Planchat
ONERA/DOTA, Université de Paris-Saclay, F- 91120 Palaiseau, France
4 shared publicationsMatthieu Valla
ONERA/DOTA, Université de Paris-Saclay, F- 91120 Palaiseau, France
4 shared publications- William Patiño Rosas
ONERA/DOTA, Université de Paris-Saclay, F- 91120 Palaiseau, France
4 shared publications
Latest Publications
- Open Access
- 20 November 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-39
Comment on egusphere-2026-4286
Wind is an essential physical variable in atmospheric physics, and airborne Doppler lidars are valuable tools for profiling wind fields over wide areas. The paper reports on wind measurements performed with an airborne 1.5 µm coherent Doppler Lidar, during a campaign called MAGIC (Monitoring of Atmospheric composition and Greenhouse gases through multi-Instrument Campaigns) that took place in summer 2021 in France and in the Arctic. Vertical profiles of the horizontal wind (u and v components) are obtained with 150 m vertical resolution and a typical horizontal resolution of 2.5 km. Continuous wind profiling capability over vertical ranges up to 7.5 km is demonstrated. Two wind products are derived and compared, depending of the method used to correct for the aircraft speed. LGE-based wind product (Lidar Ground Echo) derives the aircraft speed from the Doppler shift measured by the lidar on the ground surface. FTI-based wind product (Flight Test Instrumentation) uses aircraft speed measurements by the navigation instruments. Through examples of lidar measurements realized during the campaign, advantages and limitations of LGE-based and FTI-based wind profiles are discussed. The LGE technique performs better over land and under clear weather, but the FTI technique, being independent of ground visibility and surface nature, is more generally usable. Yet it is found to exhibit some excess noise in the range of +0.6 to +0.8 m.s‑1 in standard deviation along zonal and meridional wind components, attributed to aircraft random vibrations. Lidar wind profiles are compared to radiosonde measurements and are shown to agree within an average standard deviation of 1.2 m.s‑1 in magnitude, over three datasets. They are also compared with independent wind data provided by the ECMWF Integrated Forecast System (IFS cycle 41r2). Both data sets agree within residual standard deviations in the range of 1.3–2 m.s‑1 for zonal and meridional components, over six different flights (~21 hours of measurements). This airborne lidar appears as a promising tool for future scientific campaigns dedicated to climate modelling and atmospheric dynamics.
- 20 November 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-39
Open AccessComment on egusphere-2026-4286
Wind is an essential physical variable in atmospheric physics, and airborne Doppler lidars are valuable tools for profiling wind fields over wide areas. The paper reports on wind measurements performed with an airborne 1.5 µm coherent Doppler Lidar, during a campaign called MAGIC (Monitoring of Atmospheric composition and Greenhouse gases through multi-Instrument Campaigns) that took place in summer 2021 in France and in the Arctic. Vertical profiles of the horizontal wind (u and v components) are obtained with 150 m vertical resolution and a typical horizontal resolution of 2.5 km. Continuous wind profiling capability over vertical ranges up to 7.5 km is demonstrated. Two wind products are derived and compared, depending of the method used to correct for the aircraft speed. LGE-based wind product (Lidar Ground Echo) derives the aircraft speed from the Doppler shift measured by the lidar on the ground surface. FTI-based wind product (Flight Test Instrumentation) uses aircraft speed measurements by the navigation instruments. Through examples of lidar measurements realized during the campaign, advantages and limitations of LGE-based and FTI-based wind profiles are discussed. The LGE technique performs better over land and under clear weather, but the FTI technique, being independent of ground visibility and surface nature, is more generally usable. Yet it is found to exhibit some excess noise in the range of +0.6 to +0.8 m.s‑1 in standard deviation along zonal and meridional wind components, attributed to aircraft random vibrations. Lidar wind profiles are compared to radiosonde measurements and are shown to agree within an average standard deviation of 1.2 m.s‑1 in magnitude, over three datasets. They are also compared with independent wind data provided by the ECMWF Integrated Forecast System (IFS cycle 41r2). Both data sets agree within residual standard deviations in the range of 1.3–2 m.s‑1 for zonal and meridional components, over six different flights (~21 hours of measurements). This airborne lidar appears as a promising tool for future scientific campaigns dedicated to climate modelling and atmospheric dynamics.
- Open Access
- 6 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-24
Comment on egusphere-2026-4176
Understanding the global carbon cycle requires observation of carbon diffusivity within the convective boundary layer (CBL). In particular, observations of the vertical evolution of CO2 turbulent flux would enable the evaluation of the spatial representativeness of in situ flux measurements and the quantification of entrainment-flux impacts on such measurements. Coherent lidar is a promising technology for this purpose, as it can perform ground-based range-resolved measurements of CO2 mixing ratio and vertical wind speed along the height of the CBL. Still, achieving a sufficiently low statistical error in the CO2 mixing ratio measurement is a key challenge in CO2 turbulent flux measurements. For this purpose, a 2.05 µm coherent differential absorption lidar (CDIAL) has been developed. This lidar features a hybrid fiber/bulk amplification chain that provides 20 kHz high pulse repetition frequency and 1 mJ pulse energy. These characteristics allow for a random error of about 30 ppm in CO2 mixing ratio measurements and 0.01 m s-1 in wind velocity, with a spatiotemporal resolution of 13 s and 115 m, enabling turbulent flux measurements. This paper presents a performance assessment of CO2 turbulent flux measurements with this CDIAL lidar, under typical meteorological conditions of CO2 uptake by photosynthesis. A new expression for random error after spatial averaging is introduced, that is verified using Monte Carlo simulations and statistical analysis on experimental measurements. CO2 fluxes measured by the lidar are discussed with respect to flux measurements made by in situ instruments. The lidar enables flux measurements over the convective boundary layer height (around 1000 m), and achieves a minimum flux detection limit of 11 µmol m-2 s-1 at a spatiotemporal resolution of 350 m and 4 hours, making it well suited for future geophysical studies of CO2 turbulent fluxes.
- 6 October 2026
- Published by Copernicus GmbH
- Vol. 2026, 1-24
Open AccessComment on egusphere-2026-4176
Understanding the global carbon cycle requires observation of carbon diffusivity within the convective boundary layer (CBL). In particular, observations of the vertical evolution of CO2 turbulent flux would enable the evaluation of the spatial representativeness of in situ flux measurements and the quantification of entrainment-flux impacts on such measurements. Coherent lidar is a promising technology for this purpose, as it can perform ground-based range-resolved measurements of CO2 mixing ratio and vertical wind speed along the height of the CBL. Still, achieving a sufficiently low statistical error in the CO2 mixing ratio measurement is a key challenge in CO2 turbulent flux measurements. For this purpose, a 2.05 µm coherent differential absorption lidar (CDIAL) has been developed. This lidar features a hybrid fiber/bulk amplification chain that provides 20 kHz high pulse repetition frequency and 1 mJ pulse energy. These characteristics allow for a random error of about 30 ppm in CO2 mixing ratio measurements and 0.01 m s-1 in wind velocity, with a spatiotemporal resolution of 13 s and 115 m, enabling turbulent flux measurements. This paper presents a performance assessment of CO2 turbulent flux measurements with this CDIAL lidar, under typical meteorological conditions of CO2 uptake by photosynthesis. A new expression for random error after spatial averaging is introduced, that is verified using Monte Carlo simulations and statistical analysis on experimental measurements. CO2 fluxes measured by the lidar are discussed with respect to flux measurements made by in situ instruments. The lidar enables flux measurements over the convective boundary layer height (around 1000 m), and achieves a minimum flux detection limit of 11 µmol m-2 s-1 at a spatiotemporal resolution of 350 m and 4 hours, making it well suited for future geophysical studies of CO2 turbulent fluxes.
- Open Access
- 20 August 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-24
Performance of a 2.05 µm coherent DIAL-Doppler Lidar for CO 2 eddy-covariance turbulent flux measurements
Understanding the global carbon cycle requires observation of carbon diffusivity within the convective boundary layer (CBL). In particular, observations of the vertical evolution of CO2 turbulent flux would enable the evaluation of the spatial representativeness of in situ flux measurements and the quantification of entrainment-flux impacts on such measurements. Coherent lidar is a promising technology for this purpose, as it can perform ground-based range-resolved measurements of CO2 mixing ratio and vertical wind speed along the height of the CBL. Still, achieving a sufficiently low statistical error in the CO2 mixing ratio measurement is a key challenge in CO2 turbulent flux measurements. For this purpose, a 2.05 µm coherent differential absorption lidar (CDIAL) has been developed. This lidar features a hybrid fiber/bulk amplification chain that provides 20 kHz high pulse repetition frequency and 1 mJ pulse energy. These characteristics allow for a random error of about 30 ppm in CO2 mixing ratio measurements and 0.01 m s-1 in wind velocity, with a spatiotemporal resolution of 13 s and 115 m, enabling turbulent flux measurements. This paper presents a performance assessment of CO2 turbulent flux measurements with this CDIAL lidar, under typical meteorological conditions of CO2 uptake by photosynthesis. A new expression for random error after spatial averaging is introduced, that is verified using Monte Carlo simulations and statistical analysis on experimental measurements. CO2 fluxes measured by the lidar are discussed with respect to flux measurements made by in situ instruments. The lidar enables flux measurements over the convective boundary layer height (around 1000 m), and achieves a minimum flux detection limit of 11 µmol m-2 s-1 at a spatiotemporal resolution of 350 m and 4 hours, making it well suited for future geophysical studies of CO2 turbulent fluxes.
- 20 August 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-24
Open AccessPerformance of a 2.05 µm coherent DIAL-Doppler Lidar for CO 2 eddy-covariance turbulent flux measurements
Understanding the global carbon cycle requires observation of carbon diffusivity within the convective boundary layer (CBL). In particular, observations of the vertical evolution of CO2 turbulent flux would enable the evaluation of the spatial representativeness of in situ flux measurements and the quantification of entrainment-flux impacts on such measurements. Coherent lidar is a promising technology for this purpose, as it can perform ground-based range-resolved measurements of CO2 mixing ratio and vertical wind speed along the height of the CBL. Still, achieving a sufficiently low statistical error in the CO2 mixing ratio measurement is a key challenge in CO2 turbulent flux measurements. For this purpose, a 2.05 µm coherent differential absorption lidar (CDIAL) has been developed. This lidar features a hybrid fiber/bulk amplification chain that provides 20 kHz high pulse repetition frequency and 1 mJ pulse energy. These characteristics allow for a random error of about 30 ppm in CO2 mixing ratio measurements and 0.01 m s-1 in wind velocity, with a spatiotemporal resolution of 13 s and 115 m, enabling turbulent flux measurements. This paper presents a performance assessment of CO2 turbulent flux measurements with this CDIAL lidar, under typical meteorological conditions of CO2 uptake by photosynthesis. A new expression for random error after spatial averaging is introduced, that is verified using Monte Carlo simulations and statistical analysis on experimental measurements. CO2 fluxes measured by the lidar are discussed with respect to flux measurements made by in situ instruments. The lidar enables flux measurements over the convective boundary layer height (around 1000 m), and achieves a minimum flux detection limit of 11 µmol m-2 s-1 at a spatiotemporal resolution of 350 m and 4 hours, making it well suited for future geophysical studies of CO2 turbulent fluxes.
- Open Access
- 31 July 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-39
Airborne Lidar measurements of wind profiles during the MAGIC-2021 campaign
Wind is an essential physical variable in atmospheric physics, and airborne Doppler lidars are valuable tools for profiling wind fields over wide areas. The paper reports on wind measurements performed with an airborne 1.5 µm coherent Doppler Lidar, during a campaign called MAGIC (Monitoring of Atmospheric composition and Greenhouse gases through multi-Instrument Campaigns) that took place in summer 2021 in France and in the Arctic. Vertical profiles of the horizontal wind (u and v components) are obtained with 150 m vertical resolution and a typical horizontal resolution of 2.5 km. Continuous wind profiling capability over vertical ranges up to 7.5 km is demonstrated. Two wind products are derived and compared, depending of the method used to correct for the aircraft speed. LGE-based wind product (Lidar Ground Echo) derives the aircraft speed from the Doppler shift measured by the lidar on the ground surface. FTI-based wind product (Flight Test Instrumentation) uses aircraft speed measurements by the navigation instruments. Through examples of lidar measurements realized during the campaign, advantages and limitations of LGE-based and FTI-based wind profiles are discussed. The LGE technique performs better over land and under clear weather, but the FTI technique, being independent of ground visibility and surface nature, is more generally usable. Yet it is found to exhibit some excess noise in the range of +0.6 to +0.8 m.s‑1 in standard deviation along zonal and meridional wind components, attributed to aircraft random vibrations. Lidar wind profiles are compared to radiosonde measurements and are shown to agree within an average standard deviation of 1.2 m.s‑1 in magnitude, over three datasets. They are also compared with independent wind data provided by the ECMWF Integrated Forecast System (IFS cycle 41r2). Both data sets agree within residual standard deviations in the range of 1.3–2 m.s‑1 for zonal and meridional components, over six different flights (~21 hours of measurements). This airborne lidar appears as a promising tool for future scientific campaigns dedicated to climate modelling and atmospheric dynamics.
- 31 July 2026
- Published by Copernicus GmbH in EGUsphere
- Vol. 2026, 1-39
Open AccessAirborne Lidar measurements of wind profiles during the MAGIC-2021 campaign
Wind is an essential physical variable in atmospheric physics, and airborne Doppler lidars are valuable tools for profiling wind fields over wide areas. The paper reports on wind measurements performed with an airborne 1.5 µm coherent Doppler Lidar, during a campaign called MAGIC (Monitoring of Atmospheric composition and Greenhouse gases through multi-Instrument Campaigns) that took place in summer 2021 in France and in the Arctic. Vertical profiles of the horizontal wind (u and v components) are obtained with 150 m vertical resolution and a typical horizontal resolution of 2.5 km. Continuous wind profiling capability over vertical ranges up to 7.5 km is demonstrated. Two wind products are derived and compared, depending of the method used to correct for the aircraft speed. LGE-based wind product (Lidar Ground Echo) derives the aircraft speed from the Doppler shift measured by the lidar on the ground surface. FTI-based wind product (Flight Test Instrumentation) uses aircraft speed measurements by the navigation instruments. Through examples of lidar measurements realized during the campaign, advantages and limitations of LGE-based and FTI-based wind profiles are discussed. The LGE technique performs better over land and under clear weather, but the FTI technique, being independent of ground visibility and surface nature, is more generally usable. Yet it is found to exhibit some excess noise in the range of +0.6 to +0.8 m.s‑1 in standard deviation along zonal and meridional wind components, attributed to aircraft random vibrations. Lidar wind profiles are compared to radiosonde measurements and are shown to agree within an average standard deviation of 1.2 m.s‑1 in magnitude, over three datasets. They are also compared with independent wind data provided by the ECMWF Integrated Forecast System (IFS cycle 41r2). Both data sets agree within residual standard deviations in the range of 1.3–2 m.s‑1 for zonal and meridional components, over six different flights (~21 hours of measurements). This airborne lidar appears as a promising tool for future scientific campaigns dedicated to climate modelling and atmospheric dynamics.
- Open Access
- 9 April 2026
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 362
Multi-heterodyne differential absorption lidar based on dual-comb spectroscopy for simultaneous greenhouse gas and wind speed measurements
In a recent study [1], we demonstrated a multi-heterodyne differential absorption lidar (DIAL) for greenhouse gas monitoring utilizing solid targets. The multi-frequency absorption measurement was achieved using electro-optic dual-comb spectroscopy (DCS) with a minimal number of comb teeth to maximize the optical power per tooth. In this work, we examine the lidar's working principle and architecture. Additionally, we present measurements of atmospheric CO2 at 1572 nm over a 1.4 km optical path conducted in summer 2023. Furthermore, we show that, due to the high power per comb tooth, multi-frequency Doppler wind speed measurements can be performed using the DCS signal from aerosol backscattering. This enables simultaneous radial wind speed and path-average gas concentration measurements, offering promising prospects for novel concepts of tunable multi-frequency lidar systems capable of simultaneously monitoring wind speed and gas concentrations.
- 9 April 2026
- Published by EDP Sciences in EPJ Web of Conferences
- Vol. 362
Open AccessMulti-heterodyne differential absorption lidar based on dual-comb spectroscopy for simultaneous greenhouse gas and wind speed measurements
In a recent study [1], we demonstrated a multi-heterodyne differential absorption lidar (DIAL) for greenhouse gas monitoring utilizing solid targets. The multi-frequency absorption measurement was achieved using electro-optic dual-comb spectroscopy (DCS) with a minimal number of comb teeth to maximize the optical power per tooth. In this work, we examine the lidar's working principle and architecture. Additionally, we present measurements of atmospheric CO2 at 1572 nm over a 1.4 km optical path conducted in summer 2023. Furthermore, we show that, due to the high power per comb tooth, multi-frequency Doppler wind speed measurements can be performed using the DCS signal from aerosol backscattering. This enables simultaneous radial wind speed and path-average gas concentration measurements, offering promising prospects for novel concepts of tunable multi-frequency lidar systems capable of simultaneously monitoring wind speed and gas concentrations.
- 16 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 10562
UV electro-optic frequency comb hybrid fiber/bulk laser system for molecular wind lidar
This work deals with a 343 nm UV laser based on the frequency tripling of a 1030 nm hybrid fiber/bulk MOPA amplifier. The seed laser source is designed to suit the molecular wind lidar application: 25 ns pulses at 40 kHz repetition rate, spectrally shaped as a frequency-comb matched to the two-waves interferometer used as lidar receiver. The signal is amplified in single-mode and LMA fibers up to a peak power of 15 kW limited by stimulated Brillouin scattering. Then, the signal is amplified in an Yb:YAG free-space amplifier to reach 36 kW peak power. Afterward, the fundamental frequency comb is converted in the UV by frequency tripling using LBO crystals with a conversion efficiency of 26%, resulting in an average power of 9.2 W (230 µJ per pulse at a repetition frequency of 40 kHz). The effect of the nonlinear conversion on the comb and its compatibility with the lidar receiver is studied.
- 16 March 2026
- Published by Optica Publishing Group in Optics Express
- Vol. 34 (6) , 10562
UV electro-optic frequency comb hybrid fiber/bulk laser system for molecular wind lidar
This work deals with a 343 nm UV laser based on the frequency tripling of a 1030 nm hybrid fiber/bulk MOPA amplifier. The seed laser source is designed to suit the molecular wind lidar application: 25 ns pulses at 40 kHz repetition rate, spectrally shaped as a frequency-comb matched to the two-waves interferometer used as lidar receiver. The signal is amplified in single-mode and LMA fibers up to a peak power of 15 kW limited by stimulated Brillouin scattering. Then, the signal is amplified in an Yb:YAG free-space amplifier to reach 36 kW peak power. Afterward, the fundamental frequency comb is converted in the UV by frequency tripling using LBO crystals with a conversion efficiency of 26%, resulting in an average power of 9.2 W (230 µJ per pulse at a repetition frequency of 40 kHz). The effect of the nonlinear conversion on the comb and its compatibility with the lidar receiver is studied.
- 28 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (8) , 13614-13627
Greenhouse gas monitoring using an IPDA lidar based on a dual-comb spectrometer
We present the development of a multi-spectral, integrated-path differential absorption (IPDA) lidar based on a dual-comb spectrometer for greenhouse gas monitoring. The system uses the lidar returns from topographic targets and does not require retroreflectors. The two frequency combs are generated by electro-optic modulation of a single continuous-wave laser diode. One of the combs is pulsed, amplified, and transmitted into the atmosphere, while the other acts as a local oscillator for coherent detection. We discuss the physical principles of the measurement, outline a performance model including speckle effects, and detail the fiber-based lidar architecture and signal processing. A maximum likelihood algorithm is used to estimate simultaneously the gas concentration and the central frequency of the comb, allowing the system to work without frequency locking. H2O (at 1544 nm) and CO2 (at 1572 nm) concentrations are monitored with a precision of 3% and 5%, respectively, using a non-cooperative target at 700 m. In addition, the measured water vapor concentrations are in excellent agreement with in-situ measurements obtained from nearby weather stations. To our knowledge, this is the first complete experimental demonstration and performance assessment of greenhouse gas monitoring with a dual-comb spectrometer using lidar echoes from topographic targets.
- 28 March 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (8) , 13614-13627
Greenhouse gas monitoring using an IPDA lidar based on a dual-comb spectrometer
We present the development of a multi-spectral, integrated-path differential absorption (IPDA) lidar based on a dual-comb spectrometer for greenhouse gas monitoring. The system uses the lidar returns from topographic targets and does not require retroreflectors. The two frequency combs are generated by electro-optic modulation of a single continuous-wave laser diode. One of the combs is pulsed, amplified, and transmitted into the atmosphere, while the other acts as a local oscillator for coherent detection. We discuss the physical principles of the measurement, outline a performance model including speckle effects, and detail the fiber-based lidar architecture and signal processing. A maximum likelihood algorithm is used to estimate simultaneously the gas concentration and the central frequency of the comb, allowing the system to work without frequency locking. H2O (at 1544 nm) and CO2 (at 1572 nm) concentrations are monitored with a precision of 3% and 5%, respectively, using a non-cooperative target at 700 m. In addition, the measured water vapor concentrations are in excellent agreement with in-situ measurements obtained from nearby weather stations. To our knowledge, this is the first complete experimental demonstration and performance assessment of greenhouse gas monitoring with a dual-comb spectrometer using lidar echoes from topographic targets.
- 12 February 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (4) , 969-972
Hybrid fiber/bulk laser source designed for CO2 and wind measurements at 2.05 µm
We present a hybrid fiber/bulk laser source designed for CO2 and wind monitoring using differential absorption LIDAR (DIAL) and coherent detection at 2.05 µm. This source features a master oscillator power amplifier (MOPA) architecture made of four fiber stages and one single-pass, end-pumped, bulk amplifier. This Letter focuses on the single-pass bulk amplifier performance and on the hybrid architecture benefits for DIAL and coherent detection. The bulk material is a holmium-doped YLF crystal that provides high efficiency amplification at 2.05 µm. This laser offers an energy breakthrough as compared to the classical stimulated Brillouin scattering (SBS) limit encountered in a fiber laser without compromising robustness, thanks to very few free-space optical elements and a small optical path. It delivers pulse energy and repetition frequency of 9.0 mJ/1 kHz or 1.2 mJ/20 kHz with 200 ns quasi Fourier-transform limited pulses.
- 12 February 2024
- Published by Optica Publishing Group in Optics Letters
- Vol. 49 (4) , 969-972
Hybrid fiber/bulk laser source designed for CO2 and wind measurements at 2.05 µm
We present a hybrid fiber/bulk laser source designed for CO2 and wind monitoring using differential absorption LIDAR (DIAL) and coherent detection at 2.05 µm. This source features a master oscillator power amplifier (MOPA) architecture made of four fiber stages and one single-pass, end-pumped, bulk amplifier. This Letter focuses on the single-pass bulk amplifier performance and on the hybrid architecture benefits for DIAL and coherent detection. The bulk material is a holmium-doped YLF crystal that provides high efficiency amplification at 2.05 µm. This laser offers an energy breakthrough as compared to the classical stimulated Brillouin scattering (SBS) limit encountered in a fiber laser without compromising robustness, thanks to very few free-space optical elements and a small optical path. It delivers pulse energy and repetition frequency of 9.0 mJ/1 kHz or 1.2 mJ/20 kHz with 200 ns quasi Fourier-transform limited pulses.
- 25 April 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (10) , 15963-15977
Electro-optic frequency comb based IPDA lidar: assessment of speckle issues
We present a theoretical, numerical and experimental assessment of the impact of speckle on a dual electro-optic frequency comb (EOFC) based system for integrated path differential absorption (IPDA) measurements. The principle of gas concentration measurements in a dual EOFC configuration in the absence of speckle is first briefly reviewed and experimentally illustrated using a C2H2 gas cell. A numerical simulation of the system performance in the presence of speckle is then outlined. The speckle-related error in the concentration estimate is found to be an increasing function of the product between the roughness of the backscattering surface and the EOFC line-spacing. As this product increases, the speckle-induced power fluctuations in the comb lines are no longer correlated to each other. To confirm this, concentration measurements are conducted using backscattered light from two different surfaces. Experiment results are in very good agreement with numerical simulations. Though detrimental for IPDA measurements, it is finally shown that decorrelation of speckle noise can be advantageously exploited for surface characterization in a dual EOFC configuration.
- 25 April 2022
- Published by Optica Publishing Group in Optics Express
- Vol. 30 (10) , 15963-15977
Electro-optic frequency comb based IPDA lidar: assessment of speckle issues
We present a theoretical, numerical and experimental assessment of the impact of speckle on a dual electro-optic frequency comb (EOFC) based system for integrated path differential absorption (IPDA) measurements. The principle of gas concentration measurements in a dual EOFC configuration in the absence of speckle is first briefly reviewed and experimentally illustrated using a C2H2 gas cell. A numerical simulation of the system performance in the presence of speckle is then outlined. The speckle-related error in the concentration estimate is found to be an increasing function of the product between the roughness of the backscattering surface and the EOFC line-spacing. As this product increases, the speckle-induced power fluctuations in the comb lines are no longer correlated to each other. To confirm this, concentration measurements are conducted using backscattered light from two different surfaces. Experiment results are in very good agreement with numerical simulations. Though detrimental for IPDA measurements, it is finally shown that decorrelation of speckle noise can be advantageously exploited for surface characterization in a dual EOFC configuration.
- 8 March 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (15) , C12-C19
2.05-µm all-fiber laser source designed for CO2and wind coherent lidar measurement
This work reports on an all-fiber pulsed laser source for simultaneous remote sensing ofconcentration and wind velocity in the 2.05 µm region. The source is based on a polarization-maintaining master oscillator power amplifier (MOPA) architecture. Two narrow-linewidth master oscillators for ON-line/OFF-linedifferential absorption lidar operation alternately seed a four-stage amplifier chain at a fast switching rate up to 20 kHz. The MOPA architecture delivers laser pulses of 120 µJ energy, 200 ns duration (600 W peak power) at 20 kHz pulse repetition rate (2.4 W average power). The output linewidth is lower than 5 MHz, close to the pulse Fourier transform limit, and the beam quality factor is. The source also provides a pre-amplified 20 mW local oscillator with a relative intensity noise ofthat ensures optimal performance for future coherent detection.- 8 March 2021
- Published by Optica Publishing Group in Applied Optics
- Vol. 60 (15) , C12-C19
2.05-µm all-fiber laser source designed for CO2and wind coherent lidar measurement
This work reports on an all-fiber pulsed laser source for simultaneous remote sensing ofconcentration and wind velocity in the 2.05 µm region. The source is based on a polarization-maintaining master oscillator power amplifier (MOPA) architecture. Two narrow-linewidth master oscillators for ON-line/OFF-linedifferential absorption lidar operation alternately seed a four-stage amplifier chain at a fast switching rate up to 20 kHz. The MOPA architecture delivers laser pulses of 120 µJ energy, 200 ns duration (600 W peak power) at 20 kHz pulse repetition rate (2.4 W average power). The output linewidth is lower than 5 MHz, close to the pulse Fourier transform limit, and the beam quality factor is. The source also provides a pre-amplified 20 mW local oscillator with a relative intensity noise ofthat ensures optimal performance for future coherent detection.