Elmar T. Peuker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elmar T. Peuker has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Timm Joachim Filler
Heinrich-Heine-Universität (HHU) Düsseldorf
7 shared publications J Jerosch
Klinik für Orthopädie und Orthopädische Chirurgie, Johanna-Etienne-Krankenhaus Neuss
2 shared publicationsA Gevargez
1 shared publicationA. Weipert
1 shared publicationB. Brandenberg
1 shared publicationD. Gronemeyer
1 shared publication
Latest Publications
- Top Cited Papers
- 4 January 2002
- Published by Wiley in Clinical Anatomy
- Vol. 15 (1) , 35-37
The nerve supply of the human auricle
Knowledge of the innervation of the outer ear is crucial for surgery in this region. The aim of this study was to describe the system of the auricular nerve supply. On 14 ears of seven cadavers the complete course of the nerve supply was exposed and categorized. A heterogeneous distribution of two cranial branchial nerves and two somatic cervical nerves was found. At the lateral as well as the medial surface the great auricular nerve prevails. No region with triple innervation was found. Clin. Anat. 15:35–37, 2002.
- 4 January 2002
- Published by Wiley in Clinical Anatomy
- Vol. 15 (1) , 35-37
Top Cited PapersThe nerve supply of the human auricle
Knowledge of the innervation of the outer ear is crucial for surgery in this region. The aim of this study was to describe the system of the auricular nerve supply. On 14 ears of seven cadavers the complete course of the nerve supply was exposed and categorized. A heterogeneous distribution of two cranial branchial nerves and two somatic cervical nerves was found. At the lateral as well as the medial surface the great auricular nerve prevails. No region with triple innervation was found. Clin. Anat. 15:35–37, 2002.
- 1 July 2001
- Published by Wiley in Clinical Anatomy
- Vol. 14 (4) , 282-284
Entrapment of the lingual nerve due to an ossified pterygospinous ligament
During a routine dissection course at the University of Muenster (Germany) an unusual course of the lingual nerve was found with entrapment of the nerve between a widely ossified pterygospinous ligament and the medial pterygoid muscle. Furthermore, the nerve's mobility was restricted by a more distal anastomosis with the inferior alveolar nerve. Although incomplete or complete ossification of the pterygospinous ligament is not uncommon, the combination with a medial course of the lingual nerve has not been described before. Besides practical importance for surgeons and anesthetists, the entrapment of the lingual nerve may lead to lingual numbness and pain associated with speech impairment.
- 1 July 2001
- Published by Wiley in Clinical Anatomy
- Vol. 14 (4) , 282-284
Entrapment of the lingual nerve due to an ossified pterygospinous ligament
During a routine dissection course at the University of Muenster (Germany) an unusual course of the lingual nerve was found with entrapment of the nerve between a widely ossified pterygospinous ligament and the medial pterygoid muscle. Furthermore, the nerve's mobility was restricted by a more distal anastomosis with the inferior alveolar nerve. Although incomplete or complete ossification of the pterygospinous ligament is not uncommon, the combination with a medial course of the lingual nerve has not been described before. Besides practical importance for surgeons and anesthetists, the entrapment of the lingual nerve may lead to lingual numbness and pain associated with speech impairment.
- 1 March 2001
- Published by Springer Nature in Mund-,Kiefer- und Gesichtschirurgie
- Vol. 5 (2) , 141-143
Operative Verfahren der Mund-, Kiefer- und Gesichtschirurgie an nach Thiel fixierten Körperspenden
Zusammenfassung Ergebnisse: Die Eignung von nach Thiel fixierten Körperspenden als Modelle für Forschung und Lehre in der Mund-Kiefer-Gesichts-Chirurgie wurde untersucht. An Thiel-fixierten Körperspenden wurden verschiedene operative Zugangswege durchgeführt und die Verwendbarkeit der Präparate von Anatomen und Operateuren beurteilt. Diskussion: Es zeigte sich eine hohe Realitätsnähe in Farbe, Struktur und Konsistenz. Das verwendete Konservierungsverfahren eignet sich in besonderer Weise als Voraussetzung für Forschung und die ärztliche Aus-, Fort- und Weiterbildung.
- 1 March 2001
- Published by Springer Nature in Mund-,Kiefer- und Gesichtschirurgie
- Vol. 5 (2) , 141-143
Operative Verfahren der Mund-, Kiefer- und Gesichtschirurgie an nach Thiel fixierten Körperspenden
Zusammenfassung Ergebnisse: Die Eignung von nach Thiel fixierten Körperspenden als Modelle für Forschung und Lehre in der Mund-Kiefer-Gesichts-Chirurgie wurde untersucht. An Thiel-fixierten Körperspenden wurden verschiedene operative Zugangswege durchgeführt und die Verwendbarkeit der Präparate von Anatomen und Operateuren beurteilt. Diskussion: Es zeigte sich eine hohe Realitätsnähe in Farbe, Struktur und Konsistenz. Das verwendete Konservierungsverfahren eignet sich in besonderer Weise als Voraussetzung für Forschung und die ärztliche Aus-, Fort- und Weiterbildung.
- 2 August 2000
- Published by Springer Nature in Der Orthopäde
- Vol. 29 (7) , 0605-0613
Virtual simulation for optimizing the range of motion in hip alloarthroplasty using an adapted trust-plate prosthesis model
The purpose of the present study was to increase the free range of motion in conventional trust-plate prosthesis design and to optimize the trust-plate contact as well as the osteointegration area below the trust-plate. For the first part of the study, the two-dimensional geometry of the osteotomy plane was demonstrated in 25 CT-reconstructed femora after performing a virtual cut at a CCD angle of 135 degrees. In the second part, we constructed a prototype of an anatomic adapted trust-plate prosthesis (A-TPP) with an optimized trust-plate and corpus geometry based on the three-dimensional data of three human cadaveric femurs (age 67-75 years). In the final step, we documented the range of motion with computer-aided movement-mapping and compared the conventional TPP with the A-TPP. The results showed a wide variance in osteotomy geometry in the 12 femurs. With the A-TPP, we were able to obtain a much better fit in the trust plate surface. The movement-mapping showed a much higher range of motion in the A-TPP implant. With the A-TPP, the implant surface area for osteointegration could also be significantly increased.
- 2 August 2000
- Published by Springer Nature in Der Orthopäde
- Vol. 29 (7) , 0605-0613
Virtual simulation for optimizing the range of motion in hip alloarthroplasty using an adapted trust-plate prosthesis model
The purpose of the present study was to increase the free range of motion in conventional trust-plate prosthesis design and to optimize the trust-plate contact as well as the osteointegration area below the trust-plate. For the first part of the study, the two-dimensional geometry of the osteotomy plane was demonstrated in 25 CT-reconstructed femora after performing a virtual cut at a CCD angle of 135 degrees. In the second part, we constructed a prototype of an anatomic adapted trust-plate prosthesis (A-TPP) with an optimized trust-plate and corpus geometry based on the three-dimensional data of three human cadaveric femurs (age 67-75 years). In the final step, we documented the range of motion with computer-aided movement-mapping and compared the conventional TPP with the A-TPP. The results showed a wide variance in osteotomy geometry in the 12 femurs. With the A-TPP, we were able to obtain a much better fit in the trust plate surface. The movement-mapping showed a much higher range of motion in the A-TPP implant. With the A-TPP, the implant surface area for osteointegration could also be significantly increased.
- 22 March 2000
- Published by Wiley in The Journal of Pathology
- Vol. 190 (5) , 635-638
Reflection contrast microscopy (RCM): a forgotten technique?
- 22 March 2000
- Published by Wiley in The Journal of Pathology
- Vol. 190 (5) , 635-638
Reflection contrast microscopy (RCM): a forgotten technique?
- 1 January 2000
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 45 (9) , 228-237
Präzision und Vergleich von CT-, MR- und DL-gesteuerten Interventionen am Beispiel der lumbalen Facetteninfiltration - eine experimentelle Untersuchung - Precision and Comparison of CT-, MRI- and X-ray-guided Interventions in Lumbar Facet Infiltration - an Experimental Study
We evaluated the accuracy of the needle tip representation by different imaging techniques for the guidance of facet infiltrations. For visualisation of the lumbar facet joints we used a high-field magnetic resonance tomograph (MRT) with a 2.0 Tesla field and 3.5 mm slice thickness, an open low-field magnetic resonance tomography (MRT) with an 0.064 Tesla field and 9 mm slice thickness, and IMATRON electron beam computed tomograph (EBCT) with a slice thickness of 6 mm, and a mobile C-arm fluoroscope. The study was performed on 4 human cadaveric lumber spine preparations, each of which had 8 facet joints. Under imaging control, special injection needles were placed as close as possible to the facet joint space. Following placement of he needle, all specimens were scanned with the electron beam tomograph using a slice thickness of 1.5 mm. The thin-slice study served as the gold standard. The distance between the tip of the needle and the facet joint was measured in all the images. Comparison of the different modalities with the gold standard revealed the following results: 1) median values of the absolute differences were 1.25 mm for high-field MRI, 1.35 mm for 6 mm EBCT, 2.05 mm for low-field MRI, and 2.30 mm for X-ray fluoroscopy. 2) While there was no statistically significant difference in the accuracy of tip localization between high-field MRI and 6" EBCT (p = 0.293), both systems were more precise than low-field MRI (p = 0.04) and X-ray fluoroscopy (p = 0.009). When choosing the best imaging technique, such additional factors as radiation, costs and time, must also be considered. Provided necessary radiological precautions are taken, and assuming careful pre-interventional planning, CT. EBCT and X-ray fluoroscopy are currently more effective than the expensive, time-consuming and costly magnetic resonance tomography.
- 1 January 2000
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 45 (9) , 228-237
Präzision und Vergleich von CT-, MR- und DL-gesteuerten Interventionen am Beispiel der lumbalen Facetteninfiltration - eine experimentelle Untersuchung - Precision and Comparison of CT-, MRI- and X-ray-guided Interventions in Lumbar Facet Infiltration - an Experimental Study
We evaluated the accuracy of the needle tip representation by different imaging techniques for the guidance of facet infiltrations. For visualisation of the lumbar facet joints we used a high-field magnetic resonance tomograph (MRT) with a 2.0 Tesla field and 3.5 mm slice thickness, an open low-field magnetic resonance tomography (MRT) with an 0.064 Tesla field and 9 mm slice thickness, and IMATRON electron beam computed tomograph (EBCT) with a slice thickness of 6 mm, and a mobile C-arm fluoroscope. The study was performed on 4 human cadaveric lumber spine preparations, each of which had 8 facet joints. Under imaging control, special injection needles were placed as close as possible to the facet joint space. Following placement of he needle, all specimens were scanned with the electron beam tomograph using a slice thickness of 1.5 mm. The thin-slice study served as the gold standard. The distance between the tip of the needle and the facet joint was measured in all the images. Comparison of the different modalities with the gold standard revealed the following results: 1) median values of the absolute differences were 1.25 mm for high-field MRI, 1.35 mm for 6 mm EBCT, 2.05 mm for low-field MRI, and 2.30 mm for X-ray fluoroscopy. 2) While there was no statistically significant difference in the accuracy of tip localization between high-field MRI and 6" EBCT (p = 0.293), both systems were more precise than low-field MRI (p = 0.04) and X-ray fluoroscopy (p = 0.009). When choosing the best imaging technique, such additional factors as radiation, costs and time, must also be considered. Provided necessary radiological precautions are taken, and assuming careful pre-interventional planning, CT. EBCT and X-ray fluoroscopy are currently more effective than the expensive, time-consuming and costly magnetic resonance tomography.
- 1 November 1999
- Published by CLOCKSS Archive in Archives of Family Medicine
- Vol. 8 (6) , 553-558
Traumatic Complications of Acupuncture: Therapists Need to Know Human Anatomy
To review the traumatic injuries that have been associated with acupuncture and to discuss how these adverse effects may be reduced by increased awareness of normal anatomy and anatomical variations. Literature search accompanied by postmortem anatomical studies. Traumatic lesions after acupuncture have been described in thoracic and abdominal viscera, in the peripheral and central nervous systems, and in blood vessels. Deaths have been recorded from pneumothorax and cardiac tamponade. The anatomical structure of the body at several acupuncture points is such that needles can reach vulnerable structures. While the frequency of adverse effects of acupuncture is unknown and they may be rare, knowledge of normal anatomy and anatomical variations is essential for safe practice and should be reviewed by regulatory bodies and those responsible for training courses.
- 1 November 1999
- Published by CLOCKSS Archive in Archives of Family Medicine
- Vol. 8 (6) , 553-558
Traumatic Complications of Acupuncture: Therapists Need to Know Human Anatomy
To review the traumatic injuries that have been associated with acupuncture and to discuss how these adverse effects may be reduced by increased awareness of normal anatomy and anatomical variations. Literature search accompanied by postmortem anatomical studies. Traumatic lesions after acupuncture have been described in thoracic and abdominal viscera, in the peripheral and central nervous systems, and in blood vessels. Deaths have been recorded from pneumothorax and cardiac tamponade. The anatomical structure of the body at several acupuncture points is such that needles can reach vulnerable structures. While the frequency of adverse effects of acupuncture is unknown and they may be rare, knowledge of normal anatomy and anatomical variations is essential for safe practice and should be reviewed by regulatory bodies and those responsible for training courses.
- 1 January 1998
- Vol. 120 (9) , 471-3
[Possibilities of multimedia online teaching in medical education].
The local independence of students and teachers is accepted to be one of the main advantages of teleteaching. New techniques allow to use the Internet protocol similar to video conferences, thus giving premises to link specialties which have to operate in different environments. Synchronous communication can be established with students even over long-distances. In a pilot study a three-directional lecture between an operating theatre, the dissection laboratory of the institute of anatomy, and a lecture hall was given. During the lesson students discussed problems with any lecturer. We were able to demonstrate a sufficient transmission capability for this real-time application provided by the available internet technology. On the other hand, great technical and personnel effort for this computer aided MOT is necessary. However, although it is often difficult to reconcile the timetable of surgeries and lectures MOT provides new potentialities in interdisciplinary medical education.
- 1 January 1998
- Vol. 120 (9) , 471-3
[Possibilities of multimedia online teaching in medical education].
The local independence of students and teachers is accepted to be one of the main advantages of teleteaching. New techniques allow to use the Internet protocol similar to video conferences, thus giving premises to link specialties which have to operate in different environments. Synchronous communication can be established with students even over long-distances. In a pilot study a three-directional lecture between an operating theatre, the dissection laboratory of the institute of anatomy, and a lecture hall was given. During the lesson students discussed problems with any lecturer. We were able to demonstrate a sufficient transmission capability for this real-time application provided by the available internet technology. On the other hand, great technical and personnel effort for this computer aided MOT is necessary. However, although it is often difficult to reconcile the timetable of surgeries and lectures MOT provides new potentialities in interdisciplinary medical education.