Didier Lemosse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Didier Lemosse has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Souza de Cursi
Département Mécanique, Institut National des Sciences Appliquées de Rouen , Saint-Etienne du Rouvray CEDEX 76801, France
5 shared publications - Younes Aoues
Laboratory of Mechanics of Normandy (LMN), INSA Rouen Normandie, 76000 Rouen, France
3 shared publications - Chao Ren
University of Stavanger , Stavanger, Norway
2 shared publications - Emmanuel Pagnacco
INSA Rouen Normandie, Normandie Univ, LMN UR 3828, F-76000 Rouen, France
2 shared publications - Christophe Gautrelet
Normandie Université, Laboratoire de Mécanique de Normandie (LMN)/INSA ROUEN Normandie
1 shared publication - Corentin Lothode
LMRS UMR 6085 CNRS Université de Rouen) Avenue de l'Université 76800 Saint-Étienne du Rouvray France
1 shared publication
Latest Publications
- 3 August 2022
- Published by Elsevier in Ocean Engineering
- Vol. 261
Investigation of blade-mast fluid-structure interaction of a tidal turbine
- 3 August 2022
- Published by Elsevier in Ocean Engineering
- Vol. 261
Investigation of blade-mast fluid-structure interaction of a tidal turbine
- Open Access
Investigation of blade-mast fluid-structure interaction of a tidal turbine
In this article, we investigate the movement and vibrations of a blade due to the presence of the mast. When the blade goes past the mast, a sudden pressure spike induces vibrations in the blade. To study the influence of the stiffness, two different structures have been investigated. We present our numerical methodology concerning solving the flow, the structure behavior and the coupling of the two systems. Then, we validate two methods against an experiment (Bahaj et al., 2007). In a third section, we present fluid-structure interaction cases. Several structures are setup by modifying the stiffness of the material. Their steady open-water (without a mast) behaviors are compared. And finally, two dynamic fluid-structure are performed to compare the behavior of an elastic blade passing next to a mast. For all the cases, we use K-FSI developed by K-Epsilon to solve the fluid-structure interaction (FSI) effects.
Open AccessInvestigation of blade-mast fluid-structure interaction of a tidal turbine
In this article, we investigate the movement and vibrations of a blade due to the presence of the mast. When the blade goes past the mast, a sudden pressure spike induces vibrations in the blade. To study the influence of the stiffness, two different structures have been investigated. We present our numerical methodology concerning solving the flow, the structure behavior and the coupling of the two systems. Then, we validate two methods against an experiment (Bahaj et al., 2007). In a third section, we present fluid-structure interaction cases. Several structures are setup by modifying the stiffness of the material. Their steady open-water (without a mast) behaviors are compared. And finally, two dynamic fluid-structure are performed to compare the behavior of an elastic blade passing next to a mast. For all the cases, we use K-FSI developed by K-Epsilon to solve the fluid-structure interaction (FSI) effects.
- Top Cited Papers
- 24 January 2022
- Published by Elsevier in Structural Safety
- Vol. 96
Ensemble of surrogates combining Kriging and Artificial Neural Networks for reliability analysis with local goodness measurement
- 24 January 2022
- Published by Elsevier in Structural Safety
- Vol. 96
Top Cited PapersEnsemble of surrogates combining Kriging and Artificial Neural Networks for reliability analysis with local goodness measurement
- Open Access
- 11 November 2021
- Published by MDPI AG in Infrastructures
- Vol. 6 (11) , 162
Design of an Active Damping System for Vibration Control of Wind Turbine Towers
The vibration of wind turbine towers is relevant to the reliability of the wind turbine structure and the quality of power production. It produces both ultimate loads and fatigue loads threatening structural safety. This paper aims to reduce vibration in wind turbine towers using an active damper named the twin rotor damper (TRD). A single degree of freedom (SDOF) oscillator with the TRD is used to approximate the response of wind turbines under a unidirectional gusty wind with loss of the electrical network. The coincidence between the wind gust and the grid loss is studied to involve the maximum loading on the structure. The performance of the proposed damping system under the maximum loading is then evaluated on the state-of-the-art wind turbine NREL 5 MW. The effectiveness of the TRD is compared to a passive tuned mass damper (TMD) designed with similar requirements. The numerical results reveal that, at the 1st natural mode, the TRD outperforms the passive TMD by three to six times. Moreover, the results show that the TRD is effective in reducing ultimate loads on wind turbine towers.
- 11 November 2021
- Published by MDPI AG in Infrastructures
- Vol. 6 (11) , 162
Open AccessDesign of an Active Damping System for Vibration Control of Wind Turbine Towers
The vibration of wind turbine towers is relevant to the reliability of the wind turbine structure and the quality of power production. It produces both ultimate loads and fatigue loads threatening structural safety. This paper aims to reduce vibration in wind turbine towers using an active damper named the twin rotor damper (TRD). A single degree of freedom (SDOF) oscillator with the TRD is used to approximate the response of wind turbines under a unidirectional gusty wind with loss of the electrical network. The coincidence between the wind gust and the grid loss is studied to involve the maximum loading on the structure. The performance of the proposed damping system under the maximum loading is then evaluated on the state-of-the-art wind turbine NREL 5 MW. The effectiveness of the TRD is compared to a passive tuned mass damper (TMD) designed with similar requirements. The numerical results reveal that, at the 1st natural mode, the TRD outperforms the passive TMD by three to six times. Moreover, the results show that the TRD is effective in reducing ultimate loads on wind turbine towers.
- 15 June 2019
- Published by Springer Nature
- p. 1001-1010
Sensitivity Analysis of Load Application Methods for Shell Finite Element Models
- 15 June 2019
- Published by Springer Nature
- p. 1001-1010
Sensitivity Analysis of Load Application Methods for Shell Finite Element Models
- 15 June 2019
- Published by Springer Nature
- p. 567-576
Uncertainty Quantification in Serviceability of Impacted Steel Pipe
- 15 June 2019
- Published by Springer Nature
- p. 567-576
Uncertainty Quantification in Serviceability of Impacted Steel Pipe
- Open Access
- 1 December 2006
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 28 (4) , 467-473
Dedicated procedures for temporal identification in a flexible multi-body system
- 1 December 2006
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 28 (4) , 467-473
Open AccessDedicated procedures for temporal identification in a flexible multi-body system
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 121-126
Optical Metrology Testing and Numerical Model Validation of Static Deformations and Stress Concentrations of Piezoelectric Actuators
Piezoelectric actuators are electro-mechanical devices widely used in mechatronics, robotics, vibro-acoustics, optics, active structures. Spatial and car industries are long-date users. They may be used in complex measurement systems for producing precisely controlled micro-displacements or for dynamic excitation of the structure whose response is studied. The axial compression mode multilayer actuator has several piezoelectric plates, usually of thickness 0.1 - 0.2 mm, separated by metallic electrodes. They are placed between thicker, protecting blocks placed at each end and also in intermediate positions. The active elements are electrically connected in parallel, and mechanically in series. The assembly may be pre-stressed in a metallic housing or just resin-protected. Any mechanical stressing of the actuator with the exception of its compression may lead to its destruction. Available data about the static use of such assemblies describe their deformation as being an elongation along the axial direction, characterized by a simple translation of the end face. In fact, the hybrid, experimental-numerical study presented here shows that when applying a DC voltage, even with no mechanical load for the actuator, its strain state is complex and is accompanied by the apparition of internal stress concentrations. The actuator structural integrity may be affected and the force applied to the external mechanical load may deviate from the axial direction
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 121-126
Optical Metrology Testing and Numerical Model Validation of Static Deformations and Stress Concentrations of Piezoelectric Actuators
Piezoelectric actuators are electro-mechanical devices widely used in mechatronics, robotics, vibro-acoustics, optics, active structures. Spatial and car industries are long-date users. They may be used in complex measurement systems for producing precisely controlled micro-displacements or for dynamic excitation of the structure whose response is studied. The axial compression mode multilayer actuator has several piezoelectric plates, usually of thickness 0.1 - 0.2 mm, separated by metallic electrodes. They are placed between thicker, protecting blocks placed at each end and also in intermediate positions. The active elements are electrically connected in parallel, and mechanically in series. The assembly may be pre-stressed in a metallic housing or just resin-protected. Any mechanical stressing of the actuator with the exception of its compression may lead to its destruction. Available data about the static use of such assemblies describe their deformation as being an elongation along the axial direction, characterized by a simple translation of the end face. In fact, the hybrid, experimental-numerical study presented here shows that when applying a DC voltage, even with no mechanical load for the actuator, its strain state is complex and is accompanied by the apparition of internal stress concentrations. The actuator structural integrity may be affected and the force applied to the external mechanical load may deviate from the axial direction
- 22 April 2006
- Published by Springer Nature in Structural and Multidisciplinary Optimization
- Vol. 31 (6) , 488-496
A computationally efficient approach to swimming monofin optimization
- 22 April 2006
- Published by Springer Nature in Structural and Multidisciplinary Optimization
- Vol. 31 (6) , 488-496
A computationally efficient approach to swimming monofin optimization