HPHakan Pilge

Hakan Pilge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hakan Pilge has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Outcome after subtalar screw arthroereisis in children with flexible flatfoot depends on time of treatment: Midterm results of 95 cases

    by Hannes Kubo, Carina Lipp, Martin Hufeland, Martin Ruppert, Bettina Westhoff, Ruediger Krauspe, Hakan Pilge


  • Open Access

    Whole bone testing in small animals: systematic characterization of the mechanical properties of different rodent bones available for rat fracture models

    by Peter M. Prodinger, Peter Foehr, Dominik Bürklein, Oliver Bissinger, Hakan Pilge, Kilian Kreutzer, Rüdiger von Eisenhart-Rothe, Thomas Tischer

    Rat fracture models are extensively used to characterize normal and pathological bone healing. Despite, systematic research on inter- and intra-individual differences of common rat bones examined is surprisingly not available. Thus, we studied the biomechanical behaviour and radiological characteristics of the humerus, the tibia and the femur of the male Wistar rat—all of which are potentially available in the experimental situation—to identify useful or detrimental biomechanical properties of each bone and to facilitate sample size calculations. 40 paired femura, tibiae and humeri of male Wistar rats (10–38 weeks, weight between 240 and 720 g) were analysed by DXA, pQCT scan and three-point-bending. Bearing and loading bars of the biomechanical setup were adapted percentually to the bone’s length. Subgroups of light (skeletal immature) rats under 400 g (N = 11, 22 specimens of each bone) and heavy (mature) rats over 400 g (N = 9, 18 specimens of each bone) were formed and evaluated separately. Radiologically, neither significant differences between left and right bones, nor a specific side preference was evident. Mean side differences of the BMC were relatively small (1–3% measured by DXA and 2.5–5% by pQCT). Over all, bone mineral content (BMC) assessed by DXA and pQCT (TOT CNT, CORT CNT) showed high correlations between each other (BMC vs. TOT and CORT CNT: R2 = 0.94–0.99). The load–displacement diagram showed a typical, reproducible curve for each type of bone. Tibiae were the longest bones (mean 41.8 ± 4.12 mm) followed by femurs (mean 38.9 ± 4.12 mm) and humeri (mean 29.88 ± 3.33 mm). Failure loads and stiffness ranged from 175.4 ± 45.23 N / 315.6 ± 63.00 N/mm for the femurs, 124.6 ± 41.13 N / 260.5 ± 59.97 N/mm for the humeri to 117.1 ± 33.94 N / 143.8 ± 36.99 N/mm for the tibiae. Smallest interindividual differences were observed in failure loads of the femurs (CV% 8.6) and tibiae (CV% 10.7) of heavy animals, light animals showed good consistency in failure loads of the humeri (CV% 7.7). Most consistent results of both sides (left vs. right) in failure loads were provided by the femurs of light animals (mean difference 4.0 ± 2.8%); concerning stiffness, humeri of heavy animals were most consistent (mean difference of 6.2 ± 5%). In general, the failure loads showed strong correlations to the BMC (R2 = 0.85–0.88) whereas stiffness correlated only moderate, except for the humerus (BMC vs. stiffness: R2 = 0.79). Altogether, the rat’s femur of mature specimens showed the most accurate and consistent radiological and biomechanical results. In synopsis with the common experimental use enabling comparison among different studies, this bone offers ideal biomechanical conditions for three point bending experiments. This can be explained by the combination of a superior aspect ratio and a round and long, straight morphology, which satisfies the beam criteria more than other bones tested.


  • Function of the extensor mechanism of the knee after using the ‘patellar-loop technique’ to reconstruct the patellar tendon when replacing the proximal tibia for tumour

    by H. Pilge, B. M. Holzapfel, H. Rechl, P. M. Prodinger, R. Lampe, U. Saur, R. Eisenhart-Rothe, H. Gollwitzer

    The aim of this study was to analyse the gait pattern, muscle force and functional outcome of patients who had undergone replacement of the proximal tibia for tumour and alloplastic reconstruction of the extensor mechanism using the patellar-loop technique. Between February 1998 and December 2009, we carried out wide local excision of a primary sarcoma of the proximal tibia, proximal tibial replacement and reconstruction of the extensor mechanism using the patellar-loop technique in 18 patients. Of these, nine were available for evaluation after a mean of 11.6 years (0.5 to 21.6). The strength of the knee extensors was measured using an Isobex machine and gait analysis was undertaken in our gait assessment laboratory. Functional outcome was assessed using the American Knee Society (AKS) and Musculoskeletal Tumor Society (MSTS) scores. The gait pattern of the patients differed in ground contact time, flexion heel strike, maximal flexion loading response and total sagittal plane excursion. The mean maximum active flexion was 91° (30° to 110°). The overall mean extensor lag was 1° (0° to 5°). The mean extensor muscle strength was 25.8% (8.3% to 90.3%) of that in the non-operated leg (p < 0.001). The mean functional scores were 68.7% (43.4% to 83.3%) (MSTS) and 71.1 (30 to 90) (AKS functional score). In summary, the results show that reconstruction of the extensor mechanism using this technique gives good biomechanical and functional results. The patients’ gait pattern is close to normal, except for a somewhat stiff knee gait pattern. The strength of the extensor mechanism is reduced, but sufficient for walking. Cite this article: Bone Joint J 2015;97-B:1063–9.


  • Osteolysis after rotator cuff repair with bioabsorbable anchors

    by H. Pilge, J. Spang, T. Rose, H. Wolter, K. Woertler, A. B. Imhoff

    The current study was designed to evaluate the rate of osteolysis and the clinical and functional outcomes in patients who underwent mini-open rotator cuff repairs using first generation bioabsorbable suture anchors. Our hypothesis was that patients with osteolysis noted on post-repair MRI would have an accompanying decrease in functional and clinical patient outcomes when compared with patients who did not have osteolysis evident on post-repair MRI.


  • Nontraumatic Subluxation of the Atlanto-Axial Joint as Rare Form of Aquired Torticollis

    by Hakan Pilge, Peter M. Prodinger, Dominik Bürklein, Boris M. Holzapfel, Jochen Lauen

    Case report and review of the literature. We report a case of Grisel's syndrome with a delayed diagnosis. The patient's first presentation in our pediatric orthopedics department was 2 month after surgery (cochlea implantation) with a persistent torticollis. Radiographs revealed a subluxated atlantoaxial joint. We treated our patient with manual repositioning and calculated antibiotics, which lead to a restitutio ad integrum within a short time. Grisel's syndrome is synonymous with rare nontraumatic, rotational subluxation of the atlantoaxial joint (C1-C2). All formerly reported cases showed a clear association to infection or were related to head and neck surgery. Still, there is a lack of understanding about pathogenetic features and causative agents. In 1977 Fielding proposed a classification of the atlantoaxial subluxation and stage-related therapy was recommended. Our patient was a 11-year-old girl with a torticollis after insertion of a cochlea implant. After surgery, physiotherapy was performed because of her wryneck. As the symptoms did not improve, she was presented in our clinic. Our radiographs revealed a subluxated atlantoaxial joint. In general anesthesia we performed a manual repositioning and she was temporarily immobilized with a cervical collar for 2 weeks. In addition, we administered calculated antibiotics, although CRP and leukocytes were not elevated. The follow up showed a good repositioning within a short time. At least in this case, our treatment led to shorter recovery and avoidance of halo fixation. Our new therapeutic approach to patients with Grisel's syndrome might lead to a shorter recovery.


  • Arthroscopic shoulder stabilization

    by H. Pilge, A.B. Imhoff