Tracy L. Faber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tracy L. Faber has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Allen Tannenbaum
Department of Applied Mathematics and Statistics Stony Brook University Stony Brook NY
2 shared publications - Anthony Yezzi
Georgia Institute of Technology
2 shared publications - Arthur E. Stillman
Emory University School of Medicine
2 shared publications - Chesnal Arepalli
Department of Radiology, Emory University, Atlanta, GA, USA
2 shared publications - Eldad Haber
Department of Earth and Ocean Science The University of British Columbia Vancouver BC Canada
2 shared publications Ernest V. Garcia
Department of Radiology and Imaging Sciences, Emory University, Atlanta
2 shared publications
Latest Publications
- 16 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Image Processing
- Vol. 23 (3) , 1340-1351
A Complete System for Automatic Extraction of Left Ventricular Myocardium From CT Images Using Shape Segmentation and Contour Evolution
The left ventricular myocardium plays a key role in the entire circulation system and an automatic delineation of the myocardium is a prerequisite for most of the subsequent functional analysis. In this paper, we present a complete system for an automatic segmentation of the left ventricular myocardium from cardiac computed tomography (CT) images using the shape information from images to be segmented. The system follows a coarse-to-fine strategy by first localizing the left ventricle and then deforming the myocardial surfaces of the left ventricle to refine the segmentation. In particular, the blood pool of a CT image is extracted and represented as a triangulated surface. Then, the left ventricle is localized as a salient component on this surface using geometric and anatomical characteristics. After that, the myocardial surfaces are initialized from the localization result and evolved by applying forces from the image intensities with a constraint based on the initial myocardial surface locations. The proposed framework has been validated on 34-human and 12-pig CT images, and the robustness and accuracy are demonstrated.
- 16 January 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Image Processing
- Vol. 23 (3) , 1340-1351
A Complete System for Automatic Extraction of Left Ventricular Myocardium From CT Images Using Shape Segmentation and Contour Evolution
The left ventricular myocardium plays a key role in the entire circulation system and an automatic delineation of the myocardium is a prerequisite for most of the subsequent functional analysis. In this paper, we present a complete system for an automatic segmentation of the left ventricular myocardium from cardiac computed tomography (CT) images using the shape information from images to be segmented. The system follows a coarse-to-fine strategy by first localizing the left ventricle and then deforming the myocardial surfaces of the left ventricle to refine the segmentation. In particular, the blood pool of a CT image is extracted and represented as a triangulated surface. Then, the left ventricle is localized as a salient component on this surface using geometric and anatomical characteristics. After that, the myocardial surfaces are initialized from the localization result and evolved by applying forces from the image intensities with a constraint based on the initial myocardial surface locations. The proposed framework has been validated on 34-human and 12-pig CT images, and the robustness and accuracy are demonstrated.
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (10) , 2887-2895
Automatic Delineation of the Myocardial Wall From CT Images Via Shape Segmentation and Variational Region Growing
Prognosis and diagnosis of cardiac diseases frequently require quantitative evaluation of the ventricle volume, mass, and ejection fraction. The delineation of the myocardial wall is involved in all of these evaluations, which is a challenging task due to large variations in myocardial shapes and image quality. In this paper, we present an automatic method for extracting the myocardial wall of the left and right ventricles from cardiac CT images. In the method, the left and right ventricles are located sequentially, in which each ventricle is detected by first identifying the endocardium and then segmenting the epicardium. To this end, the endocardium is localized by utilizing its geometric features obtained on-line from a CT image. After that, a variational region-growing model is employed to extract the epicardium of the ventricles. In particular, the location of the endocardium of the left ventricle is determined via using an active contour model on the blood-pool surface. To localize the right ventricle, the active contour model is applied on a heart surface extracted based on the left ventricle segmentation result. The robustness and accuracy of the proposed approach is demonstrated by experimental results from 33 human and 12 pig CT images.
- 1 October 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 60 (10) , 2887-2895
Automatic Delineation of the Myocardial Wall From CT Images Via Shape Segmentation and Variational Region Growing
Prognosis and diagnosis of cardiac diseases frequently require quantitative evaluation of the ventricle volume, mass, and ejection fraction. The delineation of the myocardial wall is involved in all of these evaluations, which is a challenging task due to large variations in myocardial shapes and image quality. In this paper, we present an automatic method for extracting the myocardial wall of the left and right ventricles from cardiac CT images. In the method, the left and right ventricles are located sequentially, in which each ventricle is detected by first identifying the endocardium and then segmenting the epicardium. To this end, the endocardium is localized by utilizing its geometric features obtained on-line from a CT image. After that, a variational region-growing model is employed to extract the epicardium of the ventricles. In particular, the location of the endocardium of the left ventricle is determined via using an active contour model on the blood-pool surface. To localize the right ventricle, the active contour model is applied on a heart surface extracted based on the left ventricle segmentation result. The robustness and accuracy of the proposed approach is demonstrated by experimental results from 33 human and 12 pig CT images.
- 19 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2296-2302
Automatic Alignment of Myocardial Perfusion Images With Contrast-Enhanced Cardiac Computed Tomography
Explicit fusion of perfusion data from Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) with coronary artery anatomy from Computed Tomographic Coronary Angiography (CTA) has been shown to improve the diagnostic yield for coronary artery disease (CAD) compared to either modality alone. However, most clinically available methods were developed for multimodal scanners or require interactive alignment prior to display and analysis. A new approach was developed to register the two distributions obtained either from a single multimodal imager or from separate scanners, and a preliminary validation was undertaken to compare the automatic alignment to interactive alignment by two experts.
- 19 September 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 58 (5) , 2296-2302
Automatic Alignment of Myocardial Perfusion Images With Contrast-Enhanced Cardiac Computed Tomography
Explicit fusion of perfusion data from Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) with coronary artery anatomy from Computed Tomographic Coronary Angiography (CTA) has been shown to improve the diagnostic yield for coronary artery disease (CAD) compared to either modality alone. However, most clinically available methods were developed for multimodal scanners or require interactive alignment prior to display and analysis. A new approach was developed to register the two distributions obtained either from a single multimodal imager or from separate scanners, and a preliminary validation was undertaken to compare the automatic alignment to interactive alignment by two experts.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 2996-2997
Automatic alignment of myocardial perfusion images with contrast cardiac Tomography
Explicit fusion of perfusion data from Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) with coronary artery anatomy from Computed Tomographic Coronary Angiography (CTCA) has been shown to improve the diagnostic yield for coronary artery disease (CAD) compared to either modality alone. However, most clinically available methods were developed for multimodal scanners or require interactive alignment prior to display and analysis. A new approach was developed to register and display the two distributions obtained either from a single multimodal imager or from separate scanners, and a preliminary validation was undertaken using interactive alignment by experts.
- 1 October 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (10823654) , 2996-2997
Automatic alignment of myocardial perfusion images with contrast cardiac Tomography
Explicit fusion of perfusion data from Positron Emission Tomography (PET) or Single Photon Emission Computed Tomography (SPECT) with coronary artery anatomy from Computed Tomographic Coronary Angiography (CTCA) has been shown to improve the diagnostic yield for coronary artery disease (CAD) compared to either modality alone. However, most clinically available methods were developed for multimodal scanners or require interactive alignment prior to display and analysis. A new approach was developed to register and display the two distributions obtained either from a single multimodal imager or from separate scanners, and a preliminary validation was undertaken using interactive alignment by experts.
- 9 January 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (3) , 797-811
Motion correction of PET brain images through deconvolution: I. Theoretical development and analysis in software simulations
Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. Existing correction methods that use known patient motion obtained from tracking devices either require multi-frame acquisitions, detailed knowledge of the scanner, or specialized reconstruction algorithms. A deconvolution algorithm has been developed that alleviates these drawbacks by using the reconstructed image to estimate the original non-blurred image using maximum likelihood estimation maximization (MLEM) techniques. A high-resolution digital phantom was created by shape-based interpolation of the digital Hoffman brain phantom. Three different sets of 20 movements were applied to the phantom. For each frame of the motion, sinograms with attenuation and three levels of noise were simulated and then reconstructed using filtered backprojection. The average of the 20 frames was considered the motion blurred image, which was restored with the deconvolution algorithm. After correction, contrast increased from a mean of 2.0, 1.8 and 1.4 in the motion blurred images, for the three increasing amounts of movement, to a mean of 2.5, 2.4 and 2.2. Mean error was reduced by an average of 55% with motion correction. In conclusion, deconvolution can be used for correction of motion blur when subject motion is known.
- 9 January 2009
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (3) , 797-811
Motion correction of PET brain images through deconvolution: I. Theoretical development and analysis in software simulations
Image quality is significantly degraded even by small amounts of patient motion in very high-resolution PET scanners. Existing correction methods that use known patient motion obtained from tracking devices either require multi-frame acquisitions, detailed knowledge of the scanner, or specialized reconstruction algorithms. A deconvolution algorithm has been developed that alleviates these drawbacks by using the reconstructed image to estimate the original non-blurred image using maximum likelihood estimation maximization (MLEM) techniques. A high-resolution digital phantom was created by shape-based interpolation of the digital Hoffman brain phantom. Three different sets of 20 movements were applied to the phantom. For each frame of the motion, sinograms with attenuation and three levels of noise were simulated and then reconstructed using filtered backprojection. The average of the 20 frames was considered the motion blurred image, which was restored with the deconvolution algorithm. After correction, contrast increased from a mean of 2.0, 1.8 and 1.4 in the motion blurred images, for the three increasing amounts of movement, to a mean of 2.5, 2.4 and 2.2. Mean error was reduced by an average of 55% with motion correction. In conclusion, deconvolution can be used for correction of motion blur when subject motion is known.