William R. Barfield
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
William R. Barfield has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Langdon A. Hartsock
Department of Orthopaedics and Physical Medicine, Medical University of South Carolina, Charleston, South Carolina
2 shared publications Douglas S. Schultz
1 shared publicationFrank Armocida
Department of Orthopaedic Surgery, Medical University of South Carolina, Charleston, SC 29425, USA
1 shared publicationHarry A. Demos
1 shared publicationHenry M. Gass
1 shared publicationJohn A. Leupold
Department of Orthopaedic Surgery, Medical University of South Carolina, Charleston, SC 29425, USA
1 shared publication
Latest Publications
- 1 January 2018
- Published by Data Trace Publishing Company in Journal of Surgical Orthopaedic Advances
- Vol. 27 (01)
2018
- 1 January 2018
- Published by Data Trace Publishing Company in Journal of Surgical Orthopaedic Advances
- Vol. 27 (01)
2018
- 1 January 2009
- Vol. 18 (4) , 163-9
Conventional plate fixation of periarticular fractures.
Over the last few years, locking plates have become increasingly popular for the treatment of a variety of periarticular fractures. Despite the popularity of these new implants, older implants have a long track record of success and are still appropriate for a variety of periarticular fractures. This article reviews some of the current literature on locking plates and compares results for general fracture types to conventional plate fixation. The question of whether a locking plate or conventional plate is best for the patient, easier for the surgeon to use, and cost-effective is discussed.
- 1 January 2009
- Vol. 18 (4) , 163-9
Conventional plate fixation of periarticular fractures.
Over the last few years, locking plates have become increasingly popular for the treatment of a variety of periarticular fractures. Despite the popularity of these new implants, older implants have a long track record of success and are still appropriate for a variety of periarticular fractures. This article reviews some of the current literature on locking plates and compares results for general fracture types to conventional plate fixation. The question of whether a locking plate or conventional plate is best for the patient, easier for the surgeon to use, and cost-effective is discussed.
- 28 April 2006
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 79B (2) , 292-297
A comparison of ProOsteon, DBX, and collagraft in a rabbit model
Many bone graft substitutes (BGSs) have been developed and are commercially available. These products differ in the tailoring of their properties, including size, form, osteoconductivity, osteoinductivity, and resorption kinetics. Differential enhancement of these properties may optimize the performance of these materials for varying applications. BGSs offer an opportunity to lessen morbidity of harvesting and use of autogenous and/or allograft bone. The purpose of this study is to quantitatively compare the magnitude of bony ingrowth and biodegradation of different commercially available BGS materials in a rabbit femoral defect model. BGSs from each of three classes (ceramic (ProOsteon), demineralized bone matrix (DBX), and composite (Collagraft)) were implanted in cylindrical defects in bilateral femoral condyles of 12 adult New Zealand White rabbits. Each of the three BGS materials and the empty controls were compared. The specimens were harvested at 3 months postimplantation for radiographic and histologic evaluation. Histomorphometry yielded resorption of graft material remaining in the index defect. Magnitude of bony ingrowth was assessed based on an 8‐bit 256 densitometry model. Histomorphometric analysis of the data demonstrated statistical differences in the resorption and magnitude of bony ingrowth of the three BGS materials. The three BGS were significantly different for ingrowth (p = 0.046) when using the Wilcoxon Test. The ceramic graft material averaged 47% bony ingrowth. Rabbit‐based DBX material showed extensive osseous ingrowth (35%) and the composite graft material demonstrated significant bony ingrowth (56%). The control, as anticipated, showed the least amount of bony ingrowth (29%). Fisher's Exact Test yielded statistical differences (p = 0.0003) when comparisons for resorption were conducted. An ideal BGS material should be biocompatible, be able to withstand the local load environment for a given application, degrade in concert with bony replacement, and be both osteoinductive and osteoconductive. This in‐vivo, head‐to‐head comparison of three commercially available BGS materials in an animal model compares these characteristics and demonstrates differences between them, which may act as a guide in the use of these products in human applications. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
- 28 April 2006
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 79B (2) , 292-297
A comparison of ProOsteon, DBX, and collagraft in a rabbit model
Many bone graft substitutes (BGSs) have been developed and are commercially available. These products differ in the tailoring of their properties, including size, form, osteoconductivity, osteoinductivity, and resorption kinetics. Differential enhancement of these properties may optimize the performance of these materials for varying applications. BGSs offer an opportunity to lessen morbidity of harvesting and use of autogenous and/or allograft bone. The purpose of this study is to quantitatively compare the magnitude of bony ingrowth and biodegradation of different commercially available BGS materials in a rabbit femoral defect model. BGSs from each of three classes (ceramic (ProOsteon), demineralized bone matrix (DBX), and composite (Collagraft)) were implanted in cylindrical defects in bilateral femoral condyles of 12 adult New Zealand White rabbits. Each of the three BGS materials and the empty controls were compared. The specimens were harvested at 3 months postimplantation for radiographic and histologic evaluation. Histomorphometry yielded resorption of graft material remaining in the index defect. Magnitude of bony ingrowth was assessed based on an 8‐bit 256 densitometry model. Histomorphometric analysis of the data demonstrated statistical differences in the resorption and magnitude of bony ingrowth of the three BGS materials. The three BGS were significantly different for ingrowth (p = 0.046) when using the Wilcoxon Test. The ceramic graft material averaged 47% bony ingrowth. Rabbit‐based DBX material showed extensive osseous ingrowth (35%) and the composite graft material demonstrated significant bony ingrowth (56%). The control, as anticipated, showed the least amount of bony ingrowth (29%). Fisher's Exact Test yielded statistical differences (p = 0.0003) when comparisons for resorption were conducted. An ideal BGS material should be biocompatible, be able to withstand the local load environment for a given application, degrade in concert with bony replacement, and be both osteoinductive and osteoconductive. This in‐vivo, head‐to‐head comparison of three commercially available BGS materials in an animal model compares these characteristics and demonstrates differences between them, which may act as a guide in the use of these products in human applications. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006
- 1 December 2004
- Published by SAGE Publications in Perceptual and Motor Skills
- Vol. 99 (3) , 811-2
Comment: “Role of Perceptual and Motor Abilities in Instep Kicking Performance of Young Soccer Players” by Zisi, Derri, and Hatzitaki
Comments and suggestions concern an article in 2003 by Zisi, Derri, & Hatzitaki.
- 1 December 2004
- Published by SAGE Publications in Perceptual and Motor Skills
- Vol. 99 (3) , 811-2
Comment: “Role of Perceptual and Motor Abilities in Instep Kicking Performance of Young Soccer Players” by Zisi, Derri, and Hatzitaki
Comments and suggestions concern an article in 2003 by Zisi, Derri, & Hatzitaki.