Indu Ayappa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Indu Ayappa has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Robert G. Norman
Division of Pulmonary and Critical Care Medicine, NYU School of Medicine, New York, NY
4 shared publications- David M. Rapoport
David M. Rapoport Sleep Research Laboratory, Division of Pulmonary, Critical Care and Sleep Medicine, Department of Medicine, Icahn School of Medicine at Mount Sinai , New York, NY
3 shared publications David M. Rapoport
Division of Pulmonary and Critical Care Medicine, NYU School of Medicine, New York, NY
2 shared publications- Kenneth I. Berger
Division of Pulmonary, Critical Care and Sleep Medicine, NYU Grossman School of Medicine, and the André Cournand Pulmonary Physiology Laboratory, Bellevue Hospital, New York, USA
2 shared publications - Roberta M. Goldring
Department of Medicine, New York University School of Medicine, New York, NY, USA
2 shared publications Albert H. W. Tsai
Division of Pulmonary and Critical Care Medicine, NYU School of Medicine, New York, NY
1 shared publication
Latest Publications
- Open Access
- 1 January 2009
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 32 (1) , 99-104
Irregular Respiration as a Marker of Wakefulness During Titration of CPAP
Regularity of respiration is characteristic of stable sleep without sleep disordered breathing. Appearance of respiratory irregularity may indicate onset of wakefulness. The present study examines whether one can detect transitions from sleep to wakefulness using only the CPAP flow signal and automate this recognition. Prospective study with blinded analysis Sleep disorder center, academic institution. 74 subjects with obstructive sleep apnea/hypopnea syndrome (OSAHS) n/a 74 CPAP titration polysomnograms in patients with OSAHS were examined. First we visually identified characteristic patterns of ventilatory irregularity on the airflow signal and tested their relation to conventional detection of EEG defined wake or arousal. To automate recognition of sleep-wake transitions we then developed an artificial neural network (ANN) whose inputs were parameters derived exclusively from the airflow signal. This ANN was trained to identify the visually detected ventilatory irregularities. Finally, we prospectively determined the accuracy of the ANN detection of wake or arousal against EEG sleep/wake transitions. A visually identified irregular respiratory pattern (IrREG) was highly predictive of appearance of EEG wakefulness (Positive Predictive Value [PPV] = 0.89 to 0.98 across subjects). Furthermore, we were able to automate identification of this irregularity with an ANN which was highly predictive for wakefulness by EEG (PPV 0.66 to 0.86). Despite not detecting all wakefulness, the high positive predictive value suggests that analysis of the respiration signal alone may be a useful indicator of CNS state with potential utility in the control of CPAP in OSAHS. The present study demonstrates the feasibility of automating the detection of IrREG.
- 1 January 2009
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 32 (1) , 99-104
Open AccessIrregular Respiration as a Marker of Wakefulness During Titration of CPAP
Regularity of respiration is characteristic of stable sleep without sleep disordered breathing. Appearance of respiratory irregularity may indicate onset of wakefulness. The present study examines whether one can detect transitions from sleep to wakefulness using only the CPAP flow signal and automate this recognition. Prospective study with blinded analysis Sleep disorder center, academic institution. 74 subjects with obstructive sleep apnea/hypopnea syndrome (OSAHS) n/a 74 CPAP titration polysomnograms in patients with OSAHS were examined. First we visually identified characteristic patterns of ventilatory irregularity on the airflow signal and tested their relation to conventional detection of EEG defined wake or arousal. To automate recognition of sleep-wake transitions we then developed an artificial neural network (ANN) whose inputs were parameters derived exclusively from the airflow signal. This ANN was trained to identify the visually detected ventilatory irregularities. Finally, we prospectively determined the accuracy of the ANN detection of wake or arousal against EEG sleep/wake transitions. A visually identified irregular respiratory pattern (IrREG) was highly predictive of appearance of EEG wakefulness (Positive Predictive Value [PPV] = 0.89 to 0.98 across subjects). Furthermore, we were able to automate identification of this irregularity with an ANN which was highly predictive for wakefulness by EEG (PPV 0.66 to 0.86). Despite not detecting all wakefulness, the high positive predictive value suggests that analysis of the respiration signal alone may be a useful indicator of CNS state with potential utility in the control of CPAP in OSAHS. The present study demonstrates the feasibility of automating the detection of IrREG.
- 15 February 2008
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 4 (1) , 26-37
Validation of a Self-Applied Unattended Monitor for Sleep Disordered Breathing
Study Objectives:To evaluate the validity of the Apnea Risk Evaluation System (ARES™) Unicorder, a self-applied, limited-channel portable monitoring device for the evaluation of sleep disordered br...
- 15 February 2008
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 4 (1) , 26-37
Validation of a Self-Applied Unattended Monitor for Sleep Disordered Breathing
Study Objectives:To evaluate the validity of the Apnea Risk Evaluation System (ARES™) Unicorder, a self-applied, limited-channel portable monitoring device for the evaluation of sleep disordered br...
- 1 January 2008
- Published by Springer Nature
- Vol. 605, 431-436
Potential Mechanism for Transition Between Acute Hypercapnia During Sleep to Chronic Hypercapnia During Wakefulness in Obstructive Sleep Apnea
This paper presents a series of experiments, both in patients and computer models, investigating the transition from acute to chronic hypercapnia in OSA. The data demonstrate that acute hypercapnia during periodic breathing occurs due to either reduction in magnitude of inter-event ventilation and/or reduction in interevent ventilatory duration relative to duration of the preceding event. The transition between acute hypercapnia during sleep and chronic sustained hypercapnia during wakefulness may be determined by an interaction between respiratory control and renal handling of HCO3 ‒
- 1 January 2008
- Published by Springer Nature
- Vol. 605, 431-436
Potential Mechanism for Transition Between Acute Hypercapnia During Sleep to Chronic Hypercapnia During Wakefulness in Obstructive Sleep Apnea
This paper presents a series of experiments, both in patients and computer models, investigating the transition from acute to chronic hypercapnia in OSA. The data demonstrate that acute hypercapnia during periodic breathing occurs due to either reduction in magnitude of inter-event ventilation and/or reduction in interevent ventilatory duration relative to duration of the preceding event. The transition between acute hypercapnia during sleep and chronic sustained hypercapnia during wakefulness may be determined by an interaction between respiratory control and renal handling of HCO3 ‒
- 1 March 2005
- Published by Elsevier in Sleep Medicine
- Vol. 6 (2) , 123-130
Immediate consequences of respiratory events in sleep disordered breathing
- 1 March 2005
- Published by Elsevier in Sleep Medicine
- Vol. 6 (2) , 123-130
Immediate consequences of respiratory events in sleep disordered breathing
- 15 October 2002
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 166 (8) , 1112-1115
Hypercapnia and Ventilatory Periodicity in Obstructive Sleep Apnea Syndrome
Prevention of acute hypercapnia during obstructive events in obstructive sleep apnea requires a balance between carbon dioxide (CO2) loading during the event and CO2 unloading in the interevent period. Earlier studies have demonstrated that acute CO2 retention may occur despite high interevent ventilation when the interevent duration is short relative to the duration of the preceding event. The present study examines the relationship between apnea and interapnea durations and relates this assessment of ventilatory periodicity to the degree of chronic hypercapnia in subjects with severe sleep apnea. A total of 18 subjects with sleep apnea (> 40 apnea/hour; chronic awake PaCO2 36–62 mm Hg) and without underlying lung disease underwent polysomnography. For each event, apnea duration, interapnea duration, and apnea/interapnea duration ratio were determined. No relationship was observed between chronic PaCO2 and mean apnea or interapnea duration (p > 0.1). However, PaCO2 was directly related to apnea/interapnea duration ratio (r = 0.48; p < 0.05) such that with increasing chronic hypercapnia the interapnea duration shortens relative to the apnea duration. The present study suggests that control of the interapnea ventilatory duration relative to the duration of the preceding apnea, is an important component of the integrated ventilatory response to CO2 loading during apnea and may contribute toward the development and/or maintenance of chronic hypercapnia in obstructive sleep apnea/hypopnea syndrome.
- 15 October 2002
- Published by Oxford University Press (OUP) in American Journal of Respiratory and Critical Care Medicine
- Vol. 166 (8) , 1112-1115
Hypercapnia and Ventilatory Periodicity in Obstructive Sleep Apnea Syndrome
Prevention of acute hypercapnia during obstructive events in obstructive sleep apnea requires a balance between carbon dioxide (CO2) loading during the event and CO2 unloading in the interevent period. Earlier studies have demonstrated that acute CO2 retention may occur despite high interevent ventilation when the interevent duration is short relative to the duration of the preceding event. The present study examines the relationship between apnea and interapnea durations and relates this assessment of ventilatory periodicity to the degree of chronic hypercapnia in subjects with severe sleep apnea. A total of 18 subjects with sleep apnea (> 40 apnea/hour; chronic awake PaCO2 36–62 mm Hg) and without underlying lung disease underwent polysomnography. For each event, apnea duration, interapnea duration, and apnea/interapnea duration ratio were determined. No relationship was observed between chronic PaCO2 and mean apnea or interapnea duration (p > 0.1). However, PaCO2 was directly related to apnea/interapnea duration ratio (r = 0.48; p < 0.05) such that with increasing chronic hypercapnia the interapnea duration shortens relative to the apnea duration. The present study suggests that control of the interapnea ventilatory duration relative to the duration of the preceding apnea, is an important component of the integrated ventilatory response to CO2 loading during apnea and may contribute toward the development and/or maintenance of chronic hypercapnia in obstructive sleep apnea/hypopnea syndrome.