CZChristian Zwiener

Christian Zwiener

*This is an algorithmically generated author record based on publicly available information.

Christian Zwiener has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Fritz H. Frimmel

    Engler-Bunte-Institute, Universitaet Karlsruhe, Karlsruhe, Germany, National Exposure Research Laboratory, U.S. Environmental Protection Agency, Athens, Georgia, Environmental Carcinogenesis Division, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina, and Federal Environmental Agency, Bad Elster, Germany

    3 shared publications
  • T. Glauner

    Engler-Bunte-Institut, Water Chemistry, Universität Karlsruhe (TH), Engler-Bunte-Ring 1, D-76131 Karlsruhe, Germany

    3 shared publications
  • F. Frimmel

    Engler-Bunte-Institute, Water Chemistry, University of Karlsruhe (TH), 76131 Karlsruhe, Germany

    2 shared publications
  • David M. De Marini

    Engler-Bunte-Institute, Universitaet Karlsruhe, Karlsruhe, Germany, National Exposure Research Laboratory, U.S. Environmental Protection Agency, Athens, Georgia, Environmental Carcinogenesis Division, U.S. Environmental Protection Agency, Research Triangle Park, North Carolina, and Federal Environmental Agency, Bad Elster, Germany

    1 shared publication
  • F Frimmel

    Engler-Bunte-Institut, Water Chemistry, Universität Karlsruhe (TH), Engler-Bunte-Ring 1, D-76131 Karlsruhe, Germany

    1 shared publication
  • F.H. Frimmel

    Engler-Bunte-Institut, Water Chemistry, Universität Karlsruhe (TH), Engler-Bunte-Ring 1, D-76131 Karlsruhe, Germany

    1 shared publication

Latest Publications

  • Drowning in Disinfection Byproducts? Assessing Swimming Pool Water

    by Christian Zwiener, Susan D. Richardson, David M. De Marini, Tamara Grummt, Thomas Glauner, Fritz H. Frimmel

    Disinfection is mandatory for swimming pools: public pools are usually disinfected by gaseous chlorine or sodium hypochlorite and cartridge filters; home pools typically use stabilized chlorine. These methods produce a variety of disinfection byproducts (DBPs), such as trihalomethanes (THMs), which are regulated carcinogenic DBPs in drinking water that have been detected in the blood and breath of swimmers and of nonswimmers at indoor pools. Also produced are halogenated acetic acids (HAAs) and haloketones, which irritate the eyes, skin, and mucous membranes; trichloramine, which is linked with swimming-pool-associated asthma; and halogenated derivatives of UV sun screens, some of which show endocrine effects. Precursors of DBPs include human body substances, chemicals used in cosmetics and sun screens, and natural organic matter. Analytical research has focused also on the identification of an additional portion of unknown DBPs using gas chromatography (GC)/mass spectrometry (MS) and liquid chromatography (LC)/MS/MS with derivatization. Children swimmers have an increased risk of developing asthma and infections of the respiratory tract and ear. A 1.6−2.0-fold increased risk for bladder cancer has been associated with swimming or showering/bathing with chlorinated water. Bladder cancer risk from THM exposure (all routes combined) was greatest among those with the GSTT1-1 gene. This suggests a mechanism involving distribution of THMs to the bladder by dermal/inhalation exposure and activation there by GSTT1-1 to mutagens. DBPs may be reduced by engineering and behavioral means, such as applying new oxidation and filtration methods, reducing bromide and iodide in the source water, increasing air circulation in indoor pools, and assuring the cleanliness of swimmers. The positive health effects gained by swimming can be increased by reducing the potential adverse health risks.


  • LC-MS analysis in the aquatic environment and in water treatment technology ? a critical review

    by Christian Zwiener, Fritz H. Frimmel

    Environmental contaminants of recent concern are pharmaceuticals, estrogens and other endocrine disrupting chemicals (EDC) such as degradation products of surfactants, algal and cyanobacterial toxins, disinfection by-products (DBPs) and metalloids. In addition, pesticides (especially their transformation products), microorganisms, and humic substances (HS), in their function as vehicles for contaminants and as precursors for by-products in water treatment, traditionally play an important role. The present status of the application of LC-MS techniques for these water constituents are discussed and examples of application are given. Solid-phase extraction with various non-selective materials in combination with liquid chromatography (LC) on reversed-phase columns have been the most widely used methods for sample preconcentration and separation for different compound classes like pesticides, pharmaceuticals or estrogens. Electrospray ionization (ESI) and atmospheric pressure ionization (APCI) are the most frequently used ionization techniques for polar and ionic compounds, as well as for less polar non-ionic ones. The facilities of LC-MS have been successfully demonstrated for different compound classes. Polar compounds from pharmaceuticals used as betablockers, iodinated X-ray contrast media, or estrogens have been determined without derivatization down to ultratrace concentrations. LC-MS can be viewed as a prerequisite for the determination of algal and cyanobacterial toxins and the homologues and oligomers of alkylphenol ethoxylates and their metabolites. Tandem mass spectrometric techniques and the use of diagnostic ions reveal their usefulness for compound-class specific screening and unknown identification, and are also valid for the analysis of pesticides and especially for their transformation products. Structural information has been gained by the application of LC-MS methods to organometallic species. New insights into the structural variety of humic substances have been made possible by FT-ICR-MS due to its ultrahigh mass resolution. Finally, exciting possibilities for rapid detection and identification of microorganisms have been made possible by MALDI and LC-MS methods.


  • LC-MS analysis in the aquatic environment and in water treatment ? a critical review

    by Christian Zwiener, Fritz H. Frimmel

    LC-MS has become an invaluable technique for trace analysis of polar compounds in aqueous samples of the environment and in water treatment. LC-MS is of particular importance due to the impetus it has provided for research into the occurrence and fate of polar contaminants, and of their even more polar transformation products. Mass spectrometric detection and identification is most widely used in combination with sample preconcentration, chromatographic separation and atmospheric pressure ionization (API). The focus of the first part of this review is directed particularly toward instruments and method development with respect to their applications for detecting emerging contaminants, microorganisms and humic substances (HS). The current status and future perspectives of 1) mass analyzers, 2) ionization techniques to interface liquid chromatography (LC) with mass spectrometry (MS), 3) methods for preconcentration and separation with respect to their application for water analysis are discussed and examples of applications are given. Quadrupole and ion trap mass analyzers with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) are already applied in routine analysis. Time-of-flight (TOF) mass spectrometers are of particular interest for accurate mass measurements for identification of unknowns. For non-polar compounds, different ionization approaches have been described, such as atmospheric pressure photoionization (APPI), electrochemistry with ESI, or electron capture ionization with APCI. In sample preconcentration and separation, solid phase extraction (SPE) with different non-selective sorbent materials and HPLC on reversed-phase materials (RP-HPLC) play the dominant role. In addition, various on-line and miniaturized approaches for sample extraction and sample introduction into the MS have been used. Ion chromatography (IC), size-exclusion chromatography (SEC), and capillary electrophoresis (CE) are alternative separation techniques. Furthermore, the issues of compound identification, matrix effects on quantitation, development of mass spectral libraries and the topic of connecting analysis and toxicity bioassays are addressed.


  • LC-ESI/MS/MS analysis with derivatization applied to polar disinfection by-products in water treatment

    by C. Zwiener, T. Glauner, F.H. Frimmel

    Chlorination and ozonation experiments under conditions close to drinking water treatment were carried out with two different tap waters with low DOC content and water from a bog lake with high natural organic matter content. THM formation was low and in the range of 10 μg/L. Derivatization with dinitrophenylhydrazine and HPLC/tandem mass spectrometry were applied to measure carbonyl DBPs by precursor ion scans at m/z 163 for aldehydes and at m/z 182 for dicarbonyls. Formaldehyde, acetaldehyde, glyoxal, and methylglyoxal were formed by chlorination and ozonation. Ozonation produced the highest levels of carbonyls, in particular in the tap water samples. A strategy for structure suggestion and identification of unknown compounds on the basis of collision-induced dissociation (CID) mass spectra (MS) is given. The resulting structures are carbonyls with additional hydroxy and carboxy groups and serve for choice or synthesis of standard compounds for further identification. The possibilities and limits of compound identification are discussed.


  • Method optimization for the determination of carbonyl compounds in disinfected water by DNPH derivatization and LC–ESI–MS–MS

    by C. Zwiener, T. Glauner, F. Frimmel

    A method has been developed for quantitative determination of carbonyl disinfection by-products (DBP) from aqueous samples by derivatization with 2,4-dinitrophenylhydrazine combined with high-performance liquid chromatography (HPLC) and electrospray ionization (ESI) tandem mass spectrometry (MS–MS). The effect of excess of derivatization reagent and derivatization time, the effect of buffer and dry-gas temperature in the ESI process, and the effect of focus potential and collision energy in MS measurement are shown. Major fragment ions for compound identification on the basis of collision-induced dissociation (CID) mass spectra (MS) are given, as are common fragments for screening analyses by MS experiments such as the use of precursor ion scans. Detection limits in the µg L–1 range could be achieved by selected ion monitoring measurements without sample preconcentration. Solid-phase extraction improved the sensitivity by a factor of 25 to 250. The applicability of the method is illustrated by DBP analyses of samples from outdoor swimming pools after chlorination. Several carbonyl compounds, e.g. aldehydes, ketones, hydroxybenzaldehyde, and dicarbonyl compounds were identified.


  • Metabolites from the biodegradation of pharmaceutical residues of ibuprofen in biofilm reactors and batch experiments

    by C. Zwiener, S. Seeger, T. Glauner, F. Frimmel

    The three metabolites hydroxyibuprofen (OH-Ibu), carboxyibuprofen (CA-Ibu), and carboxyhydratropic acid (CA-HA), also known from human metabolism of ibuprofen, could be identified in biodegradation experiments. Identification was based on EI mass spectra and comparison with literature data. Detection was performed by selective MS–MS measurements by GC–ion-trap MS and online methylation. Ibuprofen (Ibu), OH-Ibu, and CA-Ibu could be detected with a signal-to-noise ratio of 10:1 at a concentration of 2 nmol L–1, CA-HA at 0.5 nmol L–1. Degradation experiments in both biofilm reactors (BFR) and batch experiments with activated sludge (BAS) reveal OH-Ibu as the major metabolite under oxic conditions, and CA-HA under anoxic conditions. CA-Ibu was found under oxic and anoxic conditions almost only in the BAS. The metabolites together do not account for more than 10% of the initial concentration of Ibu.


  • Determination of the strong mutagen 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) and its analogues by GC–ITD–MS–MS

    by C. Zwiener, L. Kronberg

    A new analytical method has been developed for the determination of chlorinated and brominated hydroxyfuranones. The method is based on separation by GC and selective determination of the compounds by use of an ion-trap mass detector. MS–MS fragmentation in an ion-trap detector can be regarded as an alternative to high-resolution mass spectrometry. Unique precursor ions were selected from the EI mass spectra and product-ion patterns were studied for a variety of collision energies. From these data, abundant mass transitions were selected for quantification and confirmation of compound identity. The method was applied to a spiked sample of chlorine-disinfected drinking water and it was found that the GC–MS–MS procedure is at least as sensitive and selective as previously published methods.