PSPavai Sthaneshwar

Pavai Sthaneshwar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pavai Sthaneshwar has a total of 47 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Golgi Protein 73 and Laminin‐γ2 Monomer‐Based Score for the Diagnosis of Advanced Liver Fibrosis in Patients With Metabolic Dysfunction‐Associated Steatotic Liver Disease

    by Xin‐Tong Ng, Jin‐Ying Teh, Pavai Sthaneshwar, Izzatul Aliaa Badaruddin, Pavitratha Puspanathan, Nik Raihan Nik Mustapha, Sanjiv Mahadeva, Wah‐Kheong Chan

    Background: This study evaluated the diagnostic performance of Golgi protein 73 (GP73), laminin‐γ2 monomer (LG2m), and the GLAS score in detecting advanced fibrosis in patients with metabolic dysfunction‐associated steatotic liver disease (MASLD). Methods: This study included patients with MASLD who underwent liver biopsy. The performance of serum levels of GP73 and LG2m and the GLAS score to diagnose advanced fibrosis was evaluated using area under receiver operating characteristic curves (AUROC). Results: The data for 209 patients with MASLD were analyzed [median age 52 (42–58) years, 53.1% men, 71.3% had steatohepatitis, 18.1% had advanced fibrosis]. The serum levels of GP73 and LG2m and the GLAS score were significantly higher in patients with advanced fibrosis compared to patients without advanced fibrosis [GP73: 83 ± 50 ng/mL vs. 61 ± 35 ng/mL, p = 0.013; LG2m: 31 (14–48) pg/mL vs. 17 (12–23) pg/mL, p < 0.001; GLAS score: 0.89 (0.49–0.97) vs. 0.47 (0.15–0.78), p < 0.001]. The AUROC of serum levels of GP73 and LG2m and GLAS for diagnosing advanced fibrosis was 0.63 (0.52–0.74), 0.73 (0.62–0.83), and 0.72 (0.61–0.82), respectively. Using the optimal cut‐off of 27 pg/mL, the sensitivity, specificity, positive predictive value, and negative predictive value of LG2m for diagnosing advanced fibrosis were 60.5%, 86.0%, 48.9%, and 90.7%, respectively. Using the optimal cut‐off of 0.75, the corresponding values for the GLAS score were 65.8%, 73.7%, 35.7%, and 90.6%, respectively. Conclusion: Serum LG2m level and the GLAS score have fair accuracy for the diagnosis of advanced fibrosis in patients with MASLD.

  • Kidney failure risk equation (KFRE), A risk-based triage for nephrology referrals: A mixed-methods study at pre-implementation phase among healthcare providers

    by Nur Raziana Rozi, Christine Shamala Selvaraj, Jia-Kai Tan, Zhan-Foong Lim, Noor Wahidah Nordin, Nuqman Hakimi Mazhar, Haris Hafizal, Hooi-Chin Beh, Quan-Hziung Lim, Ying-Guat Ooi, et al.


  • Open Access

    A Machine Learning Approach to Reference Interval Estimation for Red Cell Parameters in a South and East Asian Population

    by Veera Sekaran Nadarajan, Pavai Sthaneshwar, Jia Qi Lim, Angeli Ambayya, Putri Junaidah Megat Yunus

    Veera Sekaran Nadarajan, M.B.B.S., Pavai Sthaneshwar, M.B.B.S., Jia Qi Lim, Ph.D., Angeli Ambayya, Ph.D., and Putri Junaidah Megat Yunus, M.Sc.. Ann Lab Med -0001;0:. https://doi.org/10.3343/alm.2025.0027


  • Open Access

    Validation of the Hepamet fibrosis score in a multi-ethnic Asian population

    by Shi-En Chong, Felicia Chang, Kee-Huat Chuah, Pavai Sthaneshwar, Nik Raihan Nik Mustapha, Sanjiv Mahadeva, Wah-Kheong Chan


  • Open Access

    Improvement in polycythaemia vera after parathyroidectomy for primary hyperparathyroidism

    by Pavai Sthaneshwar, Nadiah Mohamed Zainuddin, Jeyakantha Ratnasingam


  • Open Access

    Limited applicability of cathepsin D for the diagnosis and monitoring of non‐alcoholic steatohepatitis

    by Sivesh K Kamarajah, Stanley Khoo, Wah‐Kheong Chan, Pavai Sthaneshwar, Nik Raihan Nik Mustapha, Sanjiv Mahadeva

    Background and Aim: To date, there are limited data on the applicability of cathepsin D for the diagnosis and monitoring of non‐alcoholic steatohepatitis (NASH).Methods: This study included patients with biopsy‐proven non‐alcoholic fatty liver disease (NAFLD) diagnosed between November 2012 and October 2015. Serum cathepsin D levels were measured using the CatD enzyme‐linked immunosorbent assay (USCN Life Science, Wuhan, China) using stored samples collected on the same day of the liver biopsy procedure. The performance of cathepsin D in the diagnosis and monitoring of NASH was evaluated using receiver operating characteristic analysis.Results: Data for 216 liver biopsies and 34 healthy controls were analyzed. The mean cathepsin D level was not significantly different between NAFLD patients and controls; between NASH and non‐NASH patients; and across the different steatosis, lobular inflammation, and hepatocyte ballooning grades. The area under receiver operating characteristic curve (AUROC) of cathepsin D for the diagnosis of NAFLD and NASH was 0.62 and 0.52, respectively. The AUROC of cathepsin D for the diagnosis of the different steatosis, lobular inflammation, and hepatocyte ballooning grades ranged from 0.51 to 0.58. Of the 216 liver biopsies, 152 were paired liver biopsies from 76 patients who had a repeat liver biopsy after 48 weeks. There was no significant change in the cathepsin D level at follow‐up compared to baseline in patients who had histological improvement or worsening for steatosis, lobular inflammation, and hepatocyte ballooning grades. Cathepsin D was poor for predicting improvement or worsening of steatosis and hepatocyte ballooning, with AUROC ranging from 0.47 to 0.54. It was fair for predicting worsening (AUROC 0.73) but poor for predicting improvement (AUROC 0.54) of lobular inflammation.Conclusion: Cathepsin D was a poor biomarker for the diagnosis and monitoring of NASH in our cohort of Asian patients, somewhat inconsistent with previous observations in Caucasian patients. Further studies in different cohorts are needed to verify our observation.


  • Open Access

    Effect of sternal closure with biological bone adhesive on pain visual analogue score and serum cytokine

    by Shahrul Hashim, Leow Yeen Chin, Sivakumar Krishnasamy, Pavai Sthaneswar, Raja Amin Raja Mokhtar

    Recently a biocompatible bone adhesive was introduced in addition to the sternal wires to expedite sternal union and improve patient recovery. In this study we aim to objectively assess the biomarker of pain in patient who received the biocompatible bone adhesive. A total of 62 patients who underwent sternotomy were prospectively randomised to receive either conventional wire closure (CWC); 32 patients or adhesive enhanced closure in addition to sternal wire (AEC); 30 patients. Patients were monitored postoperatively at certain time intervals for incisional pain, serum Interleukin-6 (IL-6) level, analgesia used and postoperative complications. All patients were followed up for 4 weeks. The post-operative pain scores with coughing were significantly higher in the CWC group at 24 hours and 48 hours. The postoperative IL 6 levels were significantly higher in the CWC group in comparison with the AEC group at 6 hours, 24 hours, and 48 hours. There were no significant differences in term of additional analgesia used. No adverse events from adhesive bone cement were observed during follow up. Adhesive-enhanced sternal closure resulted in modest reduction of pain confirmed by reduction of pain biomarker. Justification of its routine use requires larger multicentre study.


  • Reference value for cardiac troponin I in a multi-ethnic group

    by Pavai Sthaneshwar, Farhi Ain Jamaluddin, Yap Sook Fan


    • 1 June 2010
      • Vol. 32  (1) , 21-6

    Comparing measured total carbon dioxide and calculated bicarbonate.

    by Nadzimah Mohd Nasir, Pavai Sthaneshwar, Putri Junaidah Megat Yunus, Sook-Fan Yap

    The objective of the study is to determine the level of agreement between measured total carbon dioxide (TCO2) and calculated bicarbonate (HCO3-) in our laboratory. TCO2 and HCO3- values of 1820 samples drawn at the same time from the patient were compared. TCO2 from venous samples was measured on Dimension RxL while HCO3- was obtained from arterial blood gas samples analyzed on Radiometer ABL 700. The TCO2 and HCO3- values correlated well (r = 0.977, p < 0.001), with the correlation given by the equation, y = 0.986x - 0.5335. Using Bland-Altman analysis, the bias was 0.87 mmol/L (SD 1.42 mmol/L), and the limits of agreement (LOA) were -1.92 to 3.67 mmol/L. Story and Poustie's criteria were applied to study the agreement between these two methods. Based on the first criterion that the bias between TCO2 and HCO3- should be less than +/- 1 mmol/L, the results for the two methods appear to be in good agreement. The second criterion requires that the LOA between the two methods should range between a bias of +/- 2 mmol/L or a total span of 4 mmol/L; the LOA was exceeded in our study. Using the total allowable error in the Bland Altman plot also showed that the two values cannot be used interchangeably especially at the lower values. TCO2 did not show good agreement with HCO3-. Clinicians should be aware of this discrepancy and hence should be cautious when using HCO3- for management of acid-base disorders.


    • 1 June 2010
      • Vol. 32  (1) , 43-7

    Urinary type IV collagen levels in diabetes mellitus.

    by Pavai Sthaneshwar, Siew-Pheng Chan

    Type IV collagen is the principal component of glomerular basement membrane and messangial matrix. Studies have shown increased levels of urinary type IV collagen (uIV) in diabetic patients compared to healthy controls. The concentration of uIV increases gradually as diabetic nephropathy progresses. This study was carried out to determine whether urinary type IV collagen (uIV) can serve as an indicator of diabetic nephropathy. Using a sandwich enzyme immunoassay technique, uIV excretion was determined in 30 type 2 diabetic patients with normoalbuminuria and 20 patients with microalbuminuria. uIV excretion was significantly increased in type 2 diabetics, in both normoalbuminuric and microalbuminuric patients, compared with healthy controls. The increase in urinary type IV collagen was well correlated with the amount of urinary albumin but not with HbA1C. Our findings that uIV is higher in those with microalbuminuria and correlates with albuminuria, support uIV as an indicator of diabetic nephropathy. Whether the increased uIV excretion would predict the impending renal failure needs further confirmation.