JZJoseph A. Zuclich

Joseph A. Zuclich

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Joseph A. Zuclich has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Bruce E. Stuck

    Northrop Grumman Information Technology, 4241 Woodcock Drive, Suite B-100, San Antonio, TX 78228-1330; † U.S. Army Medical Research Detachment, 7965 Dave Erwin Drive, Brooks City-Base, TX 78235-5108

    5 shared publications
  • David J. Lund

    Northrop Grumman Information Technology, 4241 Woodcock Drive, Suite B-100, San Antonio, TX 78228-1330; † U.S. Army Medical Research Detachment, 7965 Dave Erwin Drive, Brooks City-Base, TX 78235-5108

    4 shared publications
  • Harry Zwick

    USA Medical Research Detachment, Brooks AFB, Texas 78235-5138

    2 shared publications
  • Paul K. Kennedy

    Air Force Research Lab. (United States)

    2 shared publications
  • Peter R. Edsall

    Northrop Grumman Corp. (United States)

    2 shared publications
  • Richard C. Hollins

    Defense Science and Technology Lab. (United Kingdom)

    2 shared publications

Latest Publications

  • WAVELENGTH DEPENDENCE OF OCULAR DAMAGE THRESHOLDS IN THE NEAR-IR TO FAR-IR TRANSITION REGION: PROPOSED REVISIONS TO MPES

    by Joseph A. Zuclich, David J. Lund, Bruce E. Stuck

    This report summarizes the results of a series of infrared (IR) laser-induced ocular damage studies conducted over the past decade. The studies examined retinal, lens, and corneal effects of laser exposures in the near-IR to far-IR transition region (wavelengths from 1.3–1.4 μm with exposure durations ranging from Q-switched to continuous wave). The corneal and retinal damage thresholds are tabulated for all pulsewidth regimes, and the wavelength dependence of the IR thresholds is discussed and contrasted to laser safety standard maximum permissible exposure limits. The analysis suggests that the current maximum permissible exposure limits could be beneficially revised to (1) relax the IR limits over wavelength ranges where unusually high safety margins may unintentionally hinder applications of recently developed military and telecommunications laser systems; (2) replace step-function discontinuities in the IR limits by continuously varying analytical functions of wavelength and pulsewidth which more closely follow the trends of the experimental retinal (for point-source laser exposures) and corneal ED50 threshold data; and (3) result in an overall simplification of the permissible exposure limits over the wavelength range from 1.2–2.6 μm. A specific proposal for amending the IR maximum permissible exposure limits over this wavelength range is presented.


  • Laser-induced retinal damage thresholds for annular retinal beam profiles

    by Paul K. Kennedy, Joseph A. Zuclich, David J. Lund, Peter R. Edsall, Stephen Till, Bruce E. Stuck, Richard C. Hollins

    The dependence of retinal damage thresholds on laser spot size, for annular retinal beam profiles, was measured in vivo for 3 μs, 590 nm pulses from a flashlamp-pumped dye laser. Minimum Visible Lesion (MVL)ED50 thresholds in rhesus were measured for annular retinal beam profiles covering 5, 10, and 20 mrad of visual field; which correspond to outer beam diameters of roughly 70, 160, and 300 μm, respectively, on the primate retina. Annular beam profiles at the retinal plane were achieved using a telescopic imaging system, with the focal properties of the eye represented as an equivalent thin lens, and all annular beam profiles had a 37% central obscuration. As a check on experimental data, theoretical MVL-ED50 thresholds for annular beam exposures were calculated using the Thompson-Gerstman granular model of laser-induced thermal damage to the retina. Threshold calculations were performed for the three experimental beam diameters and for an intermediate case with an outer beam diameter of 230 μm. Results indicate that the threshold vs. spot size trends, for annular beams, are similar to the trends for top hat beams determined in a previous study; i.e., the threshold dose varies with the retinal image area for larger image sizes. The model correctly predicts the threshold vs. spot size trends seen in the biological data, for both annular and top hat retinal beam profiles.


  • Variation of laser induced retinal-damage threshold with retinal image size

    by Joseph A. Zuclich, Peter R. Edsall, David J. Lund, Bruce E. Stuck, Richard C. Hollins, Stephen Till, Peter A. Smith, Leon N. Mclin, Paul K. Kennedy


  • Ophthalmoscopic and pathologic description of ocular damage induced by infrared laser radiation

    by Joseph A. Zuclich, Harry Zwick, Steven T. Schuschereba, Bruce E. Stuck, Frank E. Cheney

    This study compares ocular damage effects induced by infrared (IR) lasers in the “eye-safe” wavelength range to those observed following visible wavlength laser exposures. In addition to routine fundus camera and slit-lamp observations, exposed subjects were examined via confocal scanning laser ophthalmoscopy. Histopathologic evaluation was conducted on eyes with both visible and IR laser induced focal lesions. IR laser exposure parameters which resulted in corneal, lenticular and/or retinal damage will be detailed. Unique aspects of the IR laser–tissue interaction will be discussed, including concurrent lesion formation in several tissues and secondary responses such as delayed inflammatory reactions. This latter effect may involve tissue not directly irradiated during the laser insult. Finally, implications for laser safety standards will be suggested.


  • Confocal scanning laser ophthalmoscopic imaging resolution of secondary retinal effects induced by laser radiation

    by Harry Zwick, David J. Lund, Bruce E. Stuck, Joseph A. Zuclich, Rowe Elliot, Steven T. Schuschereba, Donald A. Gagliano, M. Belkin, Randolph D. Glickman

    We have evaluated secondary laser induced retinal effects in non-human primates with a Rodenstock confocal scanning laser ophthalmoscope. A small eye animal model, the Garter snake, was employed to evaluate confocal numerical aperture effects in imaging laser retinal damage in small eyes vs. large eyes. Results demonstrate that the confocal image resolution in the Rhesus monkey eye is sufficient to differentiate deep retinal scar formation from retinal nerve fiber layer (NFL) damage and to estimate the depth of the NFL damage. The best comparison with histological depth was obtained for the snake retina, yielding a ratio close to 1:1 compared to 2:1 for the Rhesus. Resolution in the Garter snake allows imaging the photoreceptor matrix and therefore, evaluation of the interrelationship between the primary damage site (posterior retina), the photoreceptor matrix, and secondary sites in the anterior retina such as the NFL and the epiretinal vascular system. Alterations in both the retinal NFL and epiretinal blood flow rate were observed within several minutes post Argon laser exposure. Unique aspects of the snake eye such as high tissue transparency and inherently high contrast cellular structures, contribute to the confocal image quality. Such factors may be nearly comparable in primate eyes suggesting that depth of resolution can be improved by smaller confocal apertures and more sensitive signal processing techniques.