Laurie E. Locascio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Laurie E. Locascio has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Michael Gaitan
Physical Measurement Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899, United States of America
2 shared publications Alyssa C. Henry
Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD, USA
1 shared publicationBruce Harper
National Institute of Standards and Technology, 100 Bureau Dr, Stop 8394, Gaithersburg, MD 20899
1 shared publicationCatherine E Perso
1 shared publicationCheng S Lee
1 shared publication- Elizabeth A. Strychalski
National Institute of Standards and Technology, Gaithersburg, MD 20899, USA
1 shared publication
Latest Publications
- 25 January 2012
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 45 (3) , 1602-1611
Quantitative Measurements of the Size Scaling of Linear and Circular DNA in Nanofluidic Slitlike Confinement
- 25 January 2012
- Published by American Chemical Society (ACS) in Macromolecules
- Vol. 45 (3) , 1602-1611
Quantitative Measurements of the Size Scaling of Linear and Circular DNA in Nanofluidic Slitlike Confinement
- 22 June 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (18) , 2707-2714
The microfluidic palette: A diffusive gradient generator with spatio-temporal control
This paper describes a new microfluidic device called the “microfluidic palette”, capable of generating multiple spatial chemical gradients simultaneously inside a microfluidic chamber. The unique aspect of this work is that chemical gradients are generated by diffusion, without convection, and can either be held constant over long periods, or modified dynamically. We characterized a representative device with a 1.5 mm circular chamber where diffusion takes place, and three access-ports for the delivery and removal of solutes. The gradient stabilizes in ≈ 15 min for small molecules and can be maintained constant indefinitely. We demonstrate overlapping gradients with different spatial location and a controlled rotation of a diffusive gradient around its centre. Finally, we demonstrate the applicability of this tool to study the chemotactic response of the bacteria P. aeruginosa to glucose.
- 22 June 2009
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 9 (18) , 2707-2714
The microfluidic palette: A diffusive gradient generator with spatio-temporal control
This paper describes a new microfluidic device called the “microfluidic palette”, capable of generating multiple spatial chemical gradients simultaneously inside a microfluidic chamber. The unique aspect of this work is that chemical gradients are generated by diffusion, without convection, and can either be held constant over long periods, or modified dynamically. We characterized a representative device with a 1.5 mm circular chamber where diffusion takes place, and three access-ports for the delivery and removal of solutes. The gradient stabilizes in ≈ 15 min for small molecules and can be maintained constant indefinitely. We demonstrate overlapping gradients with different spatial location and a controlled rotation of a diffusive gradient around its centre. Finally, we demonstrate the applicability of this tool to study the chemotactic response of the bacteria P. aeruginosa to glucose.
- 31 August 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (11) , 1567-1573
Using pattern homogenization of binary grayscale masks to fabricate microfluidic structures with 3D topography
Because fluids at the microscale form three dimensional interfaces and are subject to three dimensional forces, the ability to create microstructures with modulated topography over large areas could greatly improve control over microfluidic phenomena (e.g., capillarity and mass transport) and enable exciting novel microfluidic applications. Here, we report a method for the fabrication of three-dimensional relief microstructures, based on the emergence of smooth features when a photopolymer is exposed to UV light through a transparency mask with binary motifs. We show that homogeneous features emerge under certain critical conditions that are also common to other, apparently unrelated, phenomena such as the emergence of macroscopic continuum properties of composite materials and the rates of ligand binding to cell membrane receptors. This fabrication method is simple and inexpensive, and yet it allows for the fabrication of microstructures over large areas (centimetres) with topographic modulation of features with characteristic dimensions smaller than 100 micrometres.
- 31 August 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (11) , 1567-1573
Using pattern homogenization of binary grayscale masks to fabricate microfluidic structures with 3D topography
Because fluids at the microscale form three dimensional interfaces and are subject to three dimensional forces, the ability to create microstructures with modulated topography over large areas could greatly improve control over microfluidic phenomena (e.g., capillarity and mass transport) and enable exciting novel microfluidic applications. Here, we report a method for the fabrication of three-dimensional relief microstructures, based on the emergence of smooth features when a photopolymer is exposed to UV light through a transparency mask with binary motifs. We show that homogeneous features emerge under certain critical conditions that are also common to other, apparently unrelated, phenomena such as the emergence of macroscopic continuum properties of composite materials and the rates of ligand binding to cell membrane receptors. This fabrication method is simple and inexpensive, and yet it allows for the fabrication of microstructures over large areas (centimetres) with topographic modulation of features with characteristic dimensions smaller than 100 micrometres.
- Open Access
- 1 January 2007
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 90 (1) , 299-333
Standard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces: Collaborative Study
The draft ASTM Standard, Standard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces,’’ was validated in a collaborative study consisting of 6 teams comprised of Civil Support personnel and First Responders, 2 levels of Bacillus anthracis Sterne and Bacillus thuringiensis Kurstaki spores, and 7 nonporous surfaces. The sample collection standard includes collection of the bulk sample (Method A) using a dry swab to push the sample onto a collection card and collection of residual sample (Method B) using an onsite test kit followed by a wet swab intended for additional onsite testing. Method A is to be performed prior to Method B in order to preserve unadulterated sample as potential criminal evidence. While statistical differences were observed between surfaces, between teams, and the interaction of surfaces and teams for the various sample types collected, these differences are due to the very low variability of the data and a much more narrow distribution than an ideal normal distribution, rather than to any practical differences. The data demonstrate that from both the 1.0 and 0.01 g powder samples, high levels of spores (mean >106 CFU) are recovered from the 7 surfaces by both the dry swab used in bulk sample collection (Method A) and the wet swab (Method B) sampling of the residual powder after bulk sample collection. Thus, after bulk sample collection, there is a high level of residual spores remaining for onsite biological testing and both Methods A and B should be performed in the field.
- 1 January 2007
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 90 (1) , 299-333
Open AccessStandard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces: Collaborative Study
The draft ASTM Standard, Standard Practice for Bulk Sample Collection and Swab Sample Collection of Visible Powders Suspected of Being Biological Agents from Nonporous Surfaces,’’ was validated in a collaborative study consisting of 6 teams comprised of Civil Support personnel and First Responders, 2 levels of Bacillus anthracis Sterne and Bacillus thuringiensis Kurstaki spores, and 7 nonporous surfaces. The sample collection standard includes collection of the bulk sample (Method A) using a dry swab to push the sample onto a collection card and collection of residual sample (Method B) using an onsite test kit followed by a wet swab intended for additional onsite testing. Method A is to be performed prior to Method B in order to preserve unadulterated sample as potential criminal evidence. While statistical differences were observed between surfaces, between teams, and the interaction of surfaces and teams for the various sample types collected, these differences are due to the very low variability of the data and a much more narrow distribution than an ideal normal distribution, rather than to any practical differences. The data demonstrate that from both the 1.0 and 0.01 g powder samples, high levels of spores (mean >106 CFU) are recovered from the 7 surfaces by both the dry swab used in bulk sample collection (Method A) and the wet swab (Method B) sampling of the residual powder after bulk sample collection. Thus, after bulk sample collection, there is a high level of residual spores remaining for onsite biological testing and both Methods A and B should be performed in the field.
- 1 June 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 379 (3) , 325-327
Microfluidic mixing
- 1 June 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 379 (3) , 325-327
Microfluidic mixing
- 18 June 2002
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 2 (3) , 135-140
Characterization and optimization of slanted well designs for microfluidic mixing under electroosmotic flow
Recently, a series of slanted wells on the floor of a microfluidic channel were experimentally shown to successfully induce off-axis transport and mixing of two confluent streams when operating under electroosmotic (EO) flow. This paper will further explore, through numerical simulations, the parameters that affect off-axis transport under EO flow with an emphasis on optimizing the mixing rate of (a) two confluent streams in steady-state or (b) the transient scenario of two confluent plugs of material, which simulates mixing after an injection. For the steady-state scenario, the degree of mixing was determined to increase by changing any of the following parameters: (1) increasing the well depth, (2) decreasing the well angle relative to the axis of the channel, and (3) increasing the EO mobility of the well walls relative to the mobility of the main channel. Also, it will be shown that folding of the fluid can occur when the well angle is sufficiently reduced and/or when the EO mobility of the wells is increased relative to the channel. The optimum configuration for the transient problem of mixing two confluent plugs includes shallow wells to minimize the well residence time, and an increased EO mobility of the well walls relative to the main channel as well as small well angles to maximize off-axis transport. The final design reported here for the transient study reduces the standard deviation of the concentration across the channel by 72% while only increasing the axial dispersion of the injected plug by 8.6 % when compared to a plug injected into a channel with no wells present. These results indicate that a series of slanted wells on the wall of a microchannel provides a means for controlling and achieving a high degree of off-axis transport and mixing in a passive manner for micro total analysis system (μTAS) devices that are driven by electroosmosis.
- 18 June 2002
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 2 (3) , 135-140
Characterization and optimization of slanted well designs for microfluidic mixing under electroosmotic flow
Recently, a series of slanted wells on the floor of a microfluidic channel were experimentally shown to successfully induce off-axis transport and mixing of two confluent streams when operating under electroosmotic (EO) flow. This paper will further explore, through numerical simulations, the parameters that affect off-axis transport under EO flow with an emphasis on optimizing the mixing rate of (a) two confluent streams in steady-state or (b) the transient scenario of two confluent plugs of material, which simulates mixing after an injection. For the steady-state scenario, the degree of mixing was determined to increase by changing any of the following parameters: (1) increasing the well depth, (2) decreasing the well angle relative to the axis of the channel, and (3) increasing the EO mobility of the well walls relative to the mobility of the main channel. Also, it will be shown that folding of the fluid can occur when the well angle is sufficiently reduced and/or when the EO mobility of the wells is increased relative to the channel. The optimum configuration for the transient problem of mixing two confluent plugs includes shallow wells to minimize the well residence time, and an increased EO mobility of the well walls relative to the main channel as well as small well angles to maximize off-axis transport. The final design reported here for the transient study reduces the standard deviation of the concentration across the channel by 72% while only increasing the axial dispersion of the injected plug by 8.6 % when compared to a plug injected into a channel with no wells present. These results indicate that a series of slanted wells on the wall of a microchannel provides a means for controlling and achieving a high degree of off-axis transport and mixing in a passive manner for micro total analysis system (μTAS) devices that are driven by electroosmosis.
- 7 March 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (5) , 799-804
Liposomes as signal amplification reagents for bioassays in microfluidic channels
- 7 March 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (5) , 799-804
Liposomes as signal amplification reagents for bioassays in microfluidic channels
- 7 March 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (5) , 791-798
Control of electroosmotic flow in laser-ablated and chemically modified hot imprinted poly(ethylene terephthalate glycol) microchannels
- 7 March 2002
- Published by Wiley in Electrophoresis
- Vol. 23 (5) , 791-798
Control of electroosmotic flow in laser-ablated and chemically modified hot imprinted poly(ethylene terephthalate glycol) microchannels
- 1 October 1999
- Published by Elsevier in Journal of Chromatography A
- Vol. 857 (1-2) , 275-284
Measurement of electroosmotic flow in plastic imprinted microfluid devices and the effect of protein adsorption on flow rate
- 1 October 1999
- Published by Elsevier in Journal of Chromatography A
- Vol. 857 (1-2) , 275-284
Measurement of electroosmotic flow in plastic imprinted microfluid devices and the effect of protein adsorption on flow rate