Robert T. Kell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Robert T. Kell has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
Yagesh Bhambhani
5 shared publicationsMamdouh Farag
University of Alberta
1 shared publication
Latest Publications
- 1 October 2006
- Published by Wolters Kluwer Health in Spine
- Vol. 31 (22) , 2630-2637
In Vivo Erector Spinae Muscle Blood Volume and Oxygenation Measures During Repetitive Incremental Lifting and Lowering in Chronic Low Back Pain Participants
A case control study. Using metabolic gas analysis and near infrared spectroscopy, a comparison was made between healthy controls and chronic low back pain (LBP) participants on cardiorespiratory, erector spinae muscle blood volume, and oxygenation responses, and these variables were used to determine factors that best predict peak oxygen consumption (VO2peak). To date, it is unknown how the cardiorespiratory and erector spinae muscles of chronic LBP persons respond to repetitive incremental lifting and lowering. With the advent of near infrared spectroscopy technology, it is now possible to noninvasively examine erector spinae muscle oxygen supply and utilization in vivo. Thus, by using metabolic gas analysis and near infrared spectroscopy technology simultaneously, it is now possible to compare the cardiorespiratory and erector spinae muscle responses of chronic LBP participants to that of healthy controls (no history of LBP) during incremental work to volitional fatigue. Thirty-four participants with chronic LBP and 34 healthy controls completed the repetitive incremental lifting and lowering (2.25 kg · min−1) protocol from floor to table (height 76 cm) at 10 lifts · min−1 to voluntary fatigue. The healthy controls had significantly greater VO2peak (mL · kg−1 · min−1) and VO2peak (mL · kgLBM−1 · min−1), peak mass lifted, test duration, and breathing frequency. Furthermore, healthy controls showed significantly greater change in muscle oxygenation and faster one-half recovery times. Multiple regression analysis indicated that approximately 97% of the variance in absolute VO2peak was predicted by cardiorespiratory variables in both groups, while muscle oxygenation aided in predicting VO2peak relative in the LBP participants. The results indicated that the chronic LBP participants demonstrated a reduced cardiorespiratory and erector spinae muscle response during repetitive incremental lifting and lowering to volitional fatigue as compared to the healthy controls.
- 1 October 2006
- Published by Wolters Kluwer Health in Spine
- Vol. 31 (22) , 2630-2637
In Vivo Erector Spinae Muscle Blood Volume and Oxygenation Measures During Repetitive Incremental Lifting and Lowering in Chronic Low Back Pain Participants
A case control study. Using metabolic gas analysis and near infrared spectroscopy, a comparison was made between healthy controls and chronic low back pain (LBP) participants on cardiorespiratory, erector spinae muscle blood volume, and oxygenation responses, and these variables were used to determine factors that best predict peak oxygen consumption (VO2peak). To date, it is unknown how the cardiorespiratory and erector spinae muscles of chronic LBP persons respond to repetitive incremental lifting and lowering. With the advent of near infrared spectroscopy technology, it is now possible to noninvasively examine erector spinae muscle oxygen supply and utilization in vivo. Thus, by using metabolic gas analysis and near infrared spectroscopy technology simultaneously, it is now possible to compare the cardiorespiratory and erector spinae muscle responses of chronic LBP participants to that of healthy controls (no history of LBP) during incremental work to volitional fatigue. Thirty-four participants with chronic LBP and 34 healthy controls completed the repetitive incremental lifting and lowering (2.25 kg · min−1) protocol from floor to table (height 76 cm) at 10 lifts · min−1 to voluntary fatigue. The healthy controls had significantly greater VO2peak (mL · kg−1 · min−1) and VO2peak (mL · kgLBM−1 · min−1), peak mass lifted, test duration, and breathing frequency. Furthermore, healthy controls showed significantly greater change in muscle oxygenation and faster one-half recovery times. Multiple regression analysis indicated that approximately 97% of the variance in absolute VO2peak was predicted by cardiorespiratory variables in both groups, while muscle oxygenation aided in predicting VO2peak relative in the LBP participants. The results indicated that the chronic LBP participants demonstrated a reduced cardiorespiratory and erector spinae muscle response during repetitive incremental lifting and lowering to volitional fatigue as compared to the healthy controls.
- 1 November 2005
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 96 (3) , 241-248
Relationship between erector spinae static endurance and muscle oxygenation-blood volume changes in healthy and low back pain subjects
The purposes of this study were to: (1) compare the muscle blood volume (Mbv) and oxygenation (Mox) responses on the right and left side erector spinae during the Biering-Sorensen muscle endurance (BSME) test between healthy, low back pain active (LBP-A) and LBP-sedentary (LBP-S) subjects using near infrared spectroscopy (NIRS), and (2) determine the relationships between the BSME time and Mbv and Mox. Informed consent was obtained from 30 healthy and 30 chronic LBP subjects. The latter group was subdivided into an active (LBP-A; n=18) and sedentary (LBP-S; n=12) subgroups based on physical activity patterns. The groups were age and sex matched. The NIRS probes were placed bilaterally on the erector spinae muscle at the level of the third lumbar vertebrae. The testing protocol was: 2-min resting baseline, BSME to voluntary fatigue, and 4-min recovery. During the BSME Mbv immediately increased for ~30–60 s, then showed an asymptote, and a steady decline towards the baseline at termination. Mox demonstrated either an initial increase followed by a systematic decrease until the termination of the BSME, or a systematic decrease throughout the BSME until termination. The LBP-S subjects showed a reduced Mox-range and slower Mox ½ recovery time on the left side suggesting a reduced aerobic capacity of the erector spinae muscle in this group. Significant correlations were noted between BSME time and the pooled values of Mox-delta and-range only in the LBP-A group. These observations suggest that factors other than erector spinae aerobic capacity can influence BSME performance.
- 1 November 2005
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 96 (3) , 241-248
Relationship between erector spinae static endurance and muscle oxygenation-blood volume changes in healthy and low back pain subjects
The purposes of this study were to: (1) compare the muscle blood volume (Mbv) and oxygenation (Mox) responses on the right and left side erector spinae during the Biering-Sorensen muscle endurance (BSME) test between healthy, low back pain active (LBP-A) and LBP-sedentary (LBP-S) subjects using near infrared spectroscopy (NIRS), and (2) determine the relationships between the BSME time and Mbv and Mox. Informed consent was obtained from 30 healthy and 30 chronic LBP subjects. The latter group was subdivided into an active (LBP-A; n=18) and sedentary (LBP-S; n=12) subgroups based on physical activity patterns. The groups were age and sex matched. The NIRS probes were placed bilaterally on the erector spinae muscle at the level of the third lumbar vertebrae. The testing protocol was: 2-min resting baseline, BSME to voluntary fatigue, and 4-min recovery. During the BSME Mbv immediately increased for ~30–60 s, then showed an asymptote, and a steady decline towards the baseline at termination. Mox demonstrated either an initial increase followed by a systematic decrease until the termination of the BSME, or a systematic decrease throughout the BSME until termination. The LBP-S subjects showed a reduced Mox-range and slower Mox ½ recovery time on the left side suggesting a reduced aerobic capacity of the erector spinae muscle in this group. Significant correlations were noted between BSME time and the pooled values of Mox-delta and-range only in the LBP-A group. These observations suggest that factors other than erector spinae aerobic capacity can influence BSME performance.
- 1 May 2005
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 37 (Supplement) , S26-S27
Cardiorespiratory And Muscle Oxygenation Responses During Work In Healthy And Low Back Pain Subjects
- 1 May 2005
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 37 (Supplement) , S26-S27
Cardiorespiratory And Muscle Oxygenation Responses During Work In Healthy And Low Back Pain Subjects
- 1 May 2005
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 37 (Supplement) , S26???S27
Cardiorespiratory And Muscle Oxygenation Responses During Work In Healthy And Low Back Pain Subjects
- 1 May 2005
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 37 (Supplement) , S26???S27
Cardiorespiratory And Muscle Oxygenation Responses During Work In Healthy And Low Back Pain Subjects
- 1 May 2004
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 91 (5-6) , 499-507
Reliability of erector spinae oxygenation and blood volume responses using near-infrared spectroscopy in healthy males
The purpose of this investigation was to (1) describe the trends in oxygenation (OXY) and blood volume (BV) of the right and left paraspinal muscles during the Biering-Sorensen muscle endurance (BSME) test using near infrared spectroscopy (NIRS), and (2) assess the test-retest reliability of OXY and BV changes during the BSME in healthy males. Seventeen healthy males [age=28.4 (9.8) years, height=1.75 (0.05) m, body mass=82.7 (9.1) kg; mean (SD)] completed two BSME trials within 1 week. NIRS probes were placed bilaterally at lumbar 3. The test was performed with the subject in the prone position using the following protocol: 2 min baseline, BSME, and 4 min recovery. The delta and range values of OXY and BV were used for analysis. Acceptable intra-class correlations were observed for endurance time and all the NIRS variables at the point of fatigue and at each 10% segment of the BSME during the two trials. Bland-Altman plots confirmed the reproducibility of the bilateral NIRS responses of the paravertebral muscles. The BV responses were more reliable than the OXY responses during the two trials. The OXY and BV responses of the paravertebral muscles during static contractions can be measured reliably using NIRS. Future studies should focus primarily on BV for analysis.
- 1 May 2004
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 91 (5-6) , 499-507
Reliability of erector spinae oxygenation and blood volume responses using near-infrared spectroscopy in healthy males
The purpose of this investigation was to (1) describe the trends in oxygenation (OXY) and blood volume (BV) of the right and left paraspinal muscles during the Biering-Sorensen muscle endurance (BSME) test using near infrared spectroscopy (NIRS), and (2) assess the test-retest reliability of OXY and BV changes during the BSME in healthy males. Seventeen healthy males [age=28.4 (9.8) years, height=1.75 (0.05) m, body mass=82.7 (9.1) kg; mean (SD)] completed two BSME trials within 1 week. NIRS probes were placed bilaterally at lumbar 3. The test was performed with the subject in the prone position using the following protocol: 2 min baseline, BSME, and 4 min recovery. The delta and range values of OXY and BV were used for analysis. Acceptable intra-class correlations were observed for endurance time and all the NIRS variables at the point of fatigue and at each 10% segment of the BSME during the two trials. Bland-Altman plots confirmed the reproducibility of the bilateral NIRS responses of the paravertebral muscles. The BV responses were more reliable than the OXY responses during the two trials. The OXY and BV responses of the paravertebral muscles during static contractions can be measured reliably using NIRS. Future studies should focus primarily on BV for analysis.