ABAuke Bogte

Auke Bogte

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Auke Bogte has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Growth rate of small pancreatic neuroendocrine tumors in multiple endocrine neoplasia type 1: results from an endoscopic ultrasound based cohort study

    by Wouter F. W. Kappelle, Gerlof D. Valk, Max Leenders, Leon M. G. Moons, Auke Bogte, Peter D. Siersema, Frank P. Vleggaar

    Background and aims In multiple endocrine neoplasia type 1 (MEN1), endoscopic ultrasound (EUS) is used for identification and follow-up of pancreatic neuroendocrine tumors (PNETs). The role of EUS in surveillance of small ( < 20 mm) PNETs is unclear, mostly because the natural course of these lesions is largely unknown. We aimed to determine annual growth and incidence rate of small PNETs in patients with MEN1 using EUS-based surveillance. Patients and methods Linear array EUS procedures in patients with MEN1 between 2002 and 2015 were identified. Number, size, and location of PNETs were recorded. Annual growth of PNETs < 20 mm identified at the initial EUS (“prevalent” PNETs) and during follow-up (“incident” PNETs) was calculated using mixed model linear regression analysis. Results A total of 54 patients were identified and 38 patients were included. In all, 226 PNETs were identified (median size 5.0 mm, interquartile range 3.7 – 7.5) of which 124 (55 %) were prevalent and 102 (45 %) were incident PNETs. Annual incidence rate was 0.79 PNETs/year (95 % confidence interval [CI] 0.73 to 0.87). Overall growth rate was 0.10 mm/year (95 %CI 0.02 to 0.19; P = 0.01); PNETs < 10 mm (n = 198) did not grow (P = 0.23), whereas PNETs ≥ 10 mm (n = 28) grew 0.44 mm/year (95 %CI 0.10 to 0.78; P = 0.01). Prevalent PNETs grew 0.21 mm/year (95 %CI 0.10 – 0.32; P < 0.001), whereas incident PNETs did not grow (P = 0.26). Conclusions The annual growth rate of small, solid PNETs in patients with MEN1 is lower than previously thought. Surveillance intervals could probably be prolonged without compromising safety.


  • Assessment of bolus transit with intraluminal impedance measurement in patients with esophageal motility disorders

    by A. Bogte, A. J. Bredenoord, J. Oors, P. D. Siersema, A. J. P. M. Smout

    Background: The clinical management of patients with non‐obstructive dysphagia is notoriously difficult. Esophageal impedance measurement can be used to measure esophageal bolus transit without the use of radiation exposure to patients. However, validation of measurement of bolus transit with impedance monitoring has only been performed in healthy subjects with normal motility and not in patients with dysphagia and esophageal motility disorders. The aim was, therefore, to investigate the relationship between transit of swallowed liquid boluses in healthy controls and in patients with dysphagia.Methods: Twenty healthy volunteers and 20 patients with dysphagia underwent concurrent impedance measurement and videofluoroscopy. Each subject swallowed five liquid barium boluses. The ability of detecting complete or incomplete bolus transit by means of impedance measurement was assessed, using radiographic bolus transit as the gold standard.Key Results: Impedance monitoring recognized stasis and transit in 80.5% of the events correctly, with 83.9% of bolus transit being recognized and 77.2% of stasis being recognized correctly. In controls 79.8% of all swallows were scored correctly, whereas in patients 81.3% of all swallows were scored correctly. Depending on the contractility pattern, between 77.0% and 94.3% of the swallows were scored correctly.Conclusions & Inferences: Impedance measurement can be used to assess bolus clearance patterns in healthy subjects, but can also be used to reliably assess bolus transit in patients with dysphagia and motility disorders.


  • Sensation of stasis is poorly correlated with impaired esophageal bolus transport

    by A. Bogte, A. J. Bredenoord, J. Oors, P. D. Siersema, A. J. P. M. Smout

    Background: It is common belief that symptoms of patients with non‐obstructive dysphagia are the result of impaired bolus clearance in the esophagus, usually caused by esophageal motility disorders. We therefore investigated the relationship between transit of swallowed boluses and the symptom dysphagia.Methods: Twenty healthy volunteers and 20 patients with dysphagia underwent videofluoroscopy. Success of bolus transport was graded on a 7‐point scale. Each subject swallowed five liquid and five solid barium boluses.Key Results: For liquids, patients reported dysphagia during 1 [0–3] of the five swallows, while controls reported no dysphagia (median 0 [0–0]; p = 0.003). For solids, patients reported dysphagia during 3 [2–4] of five swallows, while controls reported dysphagia in 0.5 [0–2] of five swallows (p = 0.001). When correlating dysphagia to ineffective clearance (score ≥3), in 3 [2–4] of five liquids, the subjects perception of clearance was related to the clearance result on fluoroscopy in patients and also 3 [1–5] were correctly perceived in controls (p = 0.6). For solids, in 4 [3–5] of five swallows, the subjects perception of clearance was related to the clearance result on fluoroscopy in patients, but only 2 [1–3] of five swallows were correctly perceived by controls, the difference being statistically significant.Conclusions & Inferences: Patients very frequently report dysphagia when bolus clearance is successful. Therefore, the major underlying problem in patients with non‐obstructive dysphagia is disordered perception and increased sensitivity to physiological bolus stasis. Treatment should therefore be directed at reducing increased sensitivity rather than at improving motility.


  • Normal values for esophageal high‐resolution manometry

    by A. Bogte, A. J. Bredenoord, J. Oors, P. D. Siersema, A. J. P. M. Smout

    Background: Esophageal high‐resolution manometry (HRM) is a novel method to assess esophageal motility. Several software and hardware systems are currently available. A set of normal values for HRM parameters was established in the US, using proprietary tactile‐sensing catheter technology (Given Imaging). We wished to determine normal values for HRM performed with another type of catheter (Unisensor).Methods: Fifty‐two healthy volunteers underwent supine HRM. Each subject swallowed 10 liquid water boluses. Esophageal contraction parameters were evaluated and normal values were calculated (defined as 5th and 95th percentile of values).Key Results: The normal range for the following parameters was calculated; distal contractile integral (mean 1319.44, with a 5–95th percentile range [185.65–3407.60]), contractile front velocity (mean 3.98, 5–95th percentile range [2.40–6.50]), Intrabolus pressure (mean 9.68, range [1.00–19.00]), contraction amplitude measured 5 cm above the esophagogastric junction (EGJ; mean 78.76, range [23.00–146.00]), contraction amplitude 15 cm above the EGJ (mean 43.66, range [3.60–96.00]), transition zone (TZ) length (mean 1.34, range [0.00–5.63]), upper esophageal sphincter (UES) pressure (mean 81.63, range [19.50–165.10]), EGJ length (mean 2.97, range [2.17–4.00]), EGJ resting pressure (mean 29.35, range [8.95–51.40]), EGJ relaxation pressure (mean 16.79, range [1.00–39.35]), IRPs4 (mean 13.42, range [2.59–28.28]), and gastric pressure (mean 5.06, range [0.00–9.46]).Conclusions & Inferences: Overall, the normal values of esophageal HRM parameters obtained with the Unisensor catheter resemble those of the previously published series. Marked differences in upper limits of normal were found for parameters related to the esophageal sphincters and TZ length. Users of HRM should be aware of these differences and define pathology based on comparison to appropriate normal values.


  • Relationship between esophageal contraction patterns and clearance of swallowed liquid and solid boluses in healthy controls and patients with dysphagia

    by A. Bogte, A. J. Bredenoord, J. Oors, P. D. Siersema, A. J. P. M. Smout

    Background Non-obstructive dysphagia patients prove to be a difficult category for clinical management. Esophageal high-resolution manometry (HRM) is a novel method, used to analyze dysphagia. However, it is not yet clear how findings on HRM relate to bolus transport through the esophagus. Methods Twenty healthy volunteers and 20 patients with dysphagia underwent HRM and videofluoroscopy in a supine position. Each subject swallowed five liquid and five solid barium boluses. Esophageal contraction parameters and bolus transport were evaluated with HRM and concurrent videofluoroscopy. Key Results Stasis of liquid and solid barium boluses occurred in patients and in healthy volunteers in 64% and 41% and in 84% and 82% of the swallows, respectively. Overall, 70% of the liquid and 72% of the solid bolus swallows were followed by a peristaltic contraction, the difference not being statistically significant. Statistically significant associations were found for transition zone length of liquid and solid boluses, and for DCI and distal contraction amplitudes for liquid stasis. No correlation was found between the degree of stasis and other manometric parameters. Conclusions & Inferences Stasis of both liquid and solid boluses occurs frequently in patients and in controls and can be regarded as physiological. Motility patterns can predict the effectiveness of bolus transit and level of stasis to some degree but the relationship between esophageal motility and transit is complex and far from perfect. Esophageal manometry is therefore currently deemed unfit to be used for the prediction of bolus transit, and should rather be used for the identification of treatable esophageal motility disorders.


  • Sa1367 Sensation of Stasis is Poorly Correlated to Impaired Esophageal Bolus Transport

    by Auke Bogte, Albert J. Bredenoord, Jac Oors, Peter D. Siersema, Andreas J. Smout


  • 137a Inter-Observer Agreement for Manometry Classification of Individual Swallows and Diagnoses Using High-Resolution Manometry (HRM) With Esophageal Pressure Topography (EPT): Results of Web-Based Studies With High Participation

    by Mark R. Fox, John E. Pandolfino, Jafar Jafari, Dieter Menne, Ana T. Abreu, Auke Bogte, Alessandra Elvevi, Antonio Ruiz de Leon, Boudewijn Ff Kessing, Lubomyr Boris, et al.


  • Reproducibility of esophageal high-resolution manometry

    by A. Bogte, A. J. Bredenoord, J. Oors, P. D. Siersema, A. J. P. M. Smout

    Esophageal high-resolution manometry (HRM) is a novel method for esophageal function testing that has prompted the development of new parameters for quantitative analysis of esophageal function. Until now, the reproducibility of these parameters has not been investigated. Twenty healthy volunteers underwent HRM on two separate days. Standard HRM parameters were measured. In addition, in conventional (virtual) line tracings, lower esophageal sphincter (LES) resting pressure, relaxation pressure, and relative relaxation pressure were measured. Firstly, for each variable, the mean percentage of covariation (100×SD/mean: %COV) was derived as a measure of inter- and intra-individual variation. Secondly, Kendall's coefficients of concordance (W values) were calculated. Thirdly, Bland-Altman plots were used to express concordance graphically. Statistically significant concordance values were found for upper esophageal sphincter (UES) pressure (W=0.90, P=0.02), transition zone length (W=0.92, P=0.01), LES length (W=0.81, P=0.04), LES pressure (W=0.75, P=0.05), LES relaxation pressure (W=0.75, P=0.03), relative LES relaxation pressure (W=0.78, P=0.05), gastric pressure (W=0.81, P=0.04), and contraction amplitude 5cm above the LES (W=0.86, P=0.03). In conventional setting, only LES resting pressure (W=0.835, P=0.03) proved significant. In HRM tracings, concordance values for contraction wave parameters, and in conventional line tracings, LES relaxation pressure and relative relaxation pressure did not reach levels of statistical significance. Esophageal HRM yields reproducible results. Parameters that represent anatomic structures show better reproducibility than contraction wave parameters. The reproducibility of LES resting and relaxation pressure assessed with HRM is better than with conventional manometry and further supports the clinical use of HRM.