Selma Schenkl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Selma Schenkl has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Iris Riemann
Fraunhofer Institute of Biomedical Technologies, Department of Laser Medicine, St. Ingbert, Germany
2 shared publicationsDaniel Sauer
Fraunhofer Institute of Biomedical Technologies, Department of Laser Medicine, St. Ingbert, Germany
1 shared publicationEike C. Weiss
Fraunhofer Institute of Biomedical Technologies, Department of Biomedical Ultrasound Research, St. Ingbert, Germany
1 shared publicationEike Weiss
Fraunhofer Institute of Biomedical Technology (Germany)
1 shared publicationFrank Stracke
Fraunhofer Institute of Biomedical Technologies, Department of Laser Medicine, St. Ingbert, Germany
1 shared publication- Frank Stracke
Fraunhofer Institut Biomedizinische Technik IBMT, St. Ingbert, Germany
1 shared publication
Latest Publications
- 22 March 2007
- Published by Wiley in Microscopy Research and Technique
- Vol. 70 (5) , 476-480
In‐vivo observation of cells with a combined high‐resolution multiphoton–acoustic scanning microscope
We present a combined multiphoton–acoustic microscope giving collocated access to the local morphological as well as mechanical properties of living cells. Both methods relay on intrinsic contrast mechanisms and dispense with the need of staining. In the acoustic part of the microscope, a gigahertz ultrasound wave is generated by an acoustic lens and the reflected sound energy is detected by the identical lens in a confocal setup. The achieved lateral resolution is in the range of 1 μm. Contrast in the images arises mainly from the local absorption of sound in the cells related to viscose damping. Additionally, acoustic microscopy can access the sound speed as well as the acoustic impedance of the cell membrane and the cell shape, as it is an intrinsic volume scanning technique. The multiphoton image formation bases on the detection of autofluorescence due to endogenous fluorophores. The nonlinearity of two‐photon absorption provides submicron lateral and axial resolution without the need of confocal optical detection. In addition, in the near‐IR cell damages are drastically reduced in comparison with direct excitation in the visible or UV. The presented setup was aligned with a dedicated procedure to ensure identical image areas. Combined multiphoton/acoustic images of living myoblast cells are discussed focusing on the reliability of the method. Microsc. Res. Tech., 2007.
- 22 March 2007
- Published by Wiley in Microscopy Research and Technique
- Vol. 70 (5) , 476-480
In‐vivo observation of cells with a combined high‐resolution multiphoton–acoustic scanning microscope
We present a combined multiphoton–acoustic microscope giving collocated access to the local morphological as well as mechanical properties of living cells. Both methods relay on intrinsic contrast mechanisms and dispense with the need of staining. In the acoustic part of the microscope, a gigahertz ultrasound wave is generated by an acoustic lens and the reflected sound energy is detected by the identical lens in a confocal setup. The achieved lateral resolution is in the range of 1 μm. Contrast in the images arises mainly from the local absorption of sound in the cells related to viscose damping. Additionally, acoustic microscopy can access the sound speed as well as the acoustic impedance of the cell membrane and the cell shape, as it is an intrinsic volume scanning technique. The multiphoton image formation bases on the detection of autofluorescence due to endogenous fluorophores. The nonlinearity of two‐photon absorption provides submicron lateral and axial resolution without the need of confocal optical detection. In addition, in the near‐IR cell damages are drastically reduced in comparison with direct excitation in the visible or UV. The presented setup was aligned with a dedicated procedure to ensure identical image areas. Combined multiphoton/acoustic images of living myoblast cells are discussed focusing on the reliability of the method. Microsc. Res. Tech., 2007.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6437, 64372A-64372
Imaging living cells with a combined high-resolution multi-photon-acoustic microscope
With increasing demand for in-vivo observation of living cells, microscope techniques that do not need staining become more and more important. In this talk we present a combined multi-photon-acoustic microscope with the possibility to measure synchronously properties addressed by ultrasound and two-photon fluorescence. Ultrasound probes the local mechanical properties of a cell, while the high resolution image of the two-photon fluorescence delivers insight in cell morphology and activity. In the acoustic part of the microscope an ultrasound wave, with a frequency of GHz, is focused by an acoustic sapphire lens and detected by a piezo electric transducer assembled to the lens. The achieved lateral resolution is in the range of 1&mgr;m. Contrast in the images arises mainly from the local absorption of sound in the cells, related to properties, such as mass density, stiffness and viscose damping. Additionally acoustic microscopy can access the cell shape and the state of the cell membrane as it is a intrinsic volume scanning technique.The optical part bases on the emission of fluorescent biomolecules naturally present in cells (e.g. NAD(P)H, protophorphyrin IX, lipofuscin, melanin). The nonlinear effect of two-photon absorption provides a high lateral and axial resolution without the need of confocal detection. In addition, in the near-IR cell damages are drastically reduced in comparison to direct excitation in the visible or UV. Both methods can be considered as minimal invasive, as they relay on intrinsic contrast mechanisms and dispense with the need of staining. First results on living cells are presented and discussed.
- 8 February 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6437, 64372A-64372
Imaging living cells with a combined high-resolution multi-photon-acoustic microscope
With increasing demand for in-vivo observation of living cells, microscope techniques that do not need staining become more and more important. In this talk we present a combined multi-photon-acoustic microscope with the possibility to measure synchronously properties addressed by ultrasound and two-photon fluorescence. Ultrasound probes the local mechanical properties of a cell, while the high resolution image of the two-photon fluorescence delivers insight in cell morphology and activity. In the acoustic part of the microscope an ultrasound wave, with a frequency of GHz, is focused by an acoustic sapphire lens and detected by a piezo electric transducer assembled to the lens. The achieved lateral resolution is in the range of 1&mgr;m. Contrast in the images arises mainly from the local absorption of sound in the cells, related to properties, such as mass density, stiffness and viscose damping. Additionally acoustic microscopy can access the cell shape and the state of the cell membrane as it is a intrinsic volume scanning technique.The optical part bases on the emission of fluorescent biomolecules naturally present in cells (e.g. NAD(P)H, protophorphyrin IX, lipofuscin, melanin). The nonlinear effect of two-photon absorption provides a high lateral and axial resolution without the need of confocal detection. In addition, in the near-IR cell damages are drastically reduced in comparison to direct excitation in the visible or UV. Both methods can be considered as minimal invasive, as they relay on intrinsic contrast mechanisms and dispense with the need of staining. First results on living cells are presented and discussed.