CLCecilia Eriksson Linsmeier

Cecilia Eriksson Linsmeier

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cecilia Eriksson Linsmeier has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Jens Schouenborg

    Neuronano Research Center, Department of Experimental Medical Science, Lund University, 221 84 Lund, Sweden

    4 shared publications
  • Lars Wallman

    Neuronano Research Center (NRC), Department of Experimental Medical Science, Lund University, Lund, Sweden

    2 shared publications
  • Nils Danielsen

    Neuronano Research Center, BMC F10, Lund University, SE-221 84 Lund, Sweden, and Division of Solid State Physics, Lund University, SE-221 00 Lund, Sweden

    2 shared publications
  • Anette Wolff

    Neuronano Research Center (NRC), Department of Experimental Medical Science, Lund University, Lund, Sweden

    1 shared publication
  • Christelle N. Prinz

    Neuronano Research Center, BMC F10, Lund University, SE-221 84 Lund, Sweden, and Division of Solid State Physics, Lund University, SE-221 00 Lund, Sweden

    1 shared publication
  • Christelle N. Prinz

    Department of Physics, Division of Solid State Physics, Lund University, Lund, Sweden, Sweden

    1 shared publication

Latest Publications

  • Open Access

    Impact of degradable nanowires on long-term brain tissue responses

    by Lina Gällentoft, Lina M. E. Pettersson, Nils Danielsen, Jens Schouenborg, Christelle N. Prinz, Cecilia Eriksson Linsmeier

    A promising approach to improve the performance of neural implants consists of adding nanomaterials, such as nanowires, to the surface of the implant. Nanostructured interfaces could improve the integration and communication stability, partly through the reduction of the cell-to-electrode distance. However, the safety issues of implanted nanowires in the brain need to be evaluated and understood before nanowires can be used on the surface of implants for long periods of time. To this end we here investigate whether implanted degradable nanowires offer any advantage over non-degradable nanowires in a long-term in vivo study (1 year) with respect to brain tissue responses. The tissue response after injection of degradable silicon oxide (SiOx)-coated gallium phosphide nanowires and biostable hafnium oxide-coated GaP nanowires into the rat striatum was compared. One year after nanowire injection, no significant difference in microglial or astrocytic response, as measured by staining for ED1 and glial fibrillary acidic protein, respectively, or in neuronal density, as measured by staining for NeuN, was found between degradable and biostable nanowires. Of the cells investigated, only microglia cells had engulfed the nanowires. The SiOx-coated nanowire residues were primarily seen in aggregated hypertrophic ED1-positive cells, possibly microglial cells that have fused to create multinucleated giant cells. Occasionally, degradable nanowires with an apparently intact shape were found inside single, small ED1-positive cells. The biostable nanowires were found intact in microglia cells of both phenotypes described. The present study shows that the degradable nanowires remain at least partly in the brain over long time periods, i.e. 1 year; however, no obvious bio-safety issues for this degradable nanomaterial could be detected.


  • Open Access

    Influence of Probe Flexibility and Gelatin Embedding on Neuronal Density and Glial Responses to Brain Implants

    by Per Köhler, Anette Wolff, Fredrik Ejserholm, Lars Wallman, Jens Schouenborg, Cecilia E Linsmeier

    To develop long-term high quality communication between brain and computer, a key issue is how to reduce the adverse foreign body responses. Here, the impact of probe flexibility and gelatine embedding on long-term (6w) tissue responses, was analyzed. Probes of same polymer material, size and shape, flexible mainly in one direction, were implanted in rat cerebral cortex (nimplants = 3 x 8) in two orientations with respect to the major movement direction of the brain relative to the skull: parallel to (flex mode) or transverse to (rigid mode). Flex mode implants were either embedded in gelatin or non-embedded. Neurons, activated microglia and astrocytes were visualized using immunohistochemistry. The astrocytic reactivity, but not microglial response, was significantly lower to probes implanted in flex mode as compared to rigid mode. The microglial response, but not astrocytic reactivity, was significantly smaller to gelatin embedded probes (flex mode) than non-embedded. Interestingly, the neuronal density was preserved in the inner zone surrounding gelatin embedded probes. This contrasts to the common reports of reduced neuronal density close to implanted probes. In conclusion, sheer stress appears to be an important factor for astrocytic reactivity to implanted probes. Moreover, gelatin embedding can improve the neuronal density and reduce the microglial response close to the probe.


  • Nanowire Biocompatibility in the Brain - Looking for a Needle in a 3D Stack

    by Cecilia Eriksson Linsmeier, Christelle N. Prinz, Lina M. E. Pettersson, Philippe Caroff, Lars Samuelson, Jens Schouenborg, Lars Montelius, Nils Danielsen

    We investigated the brain-tissue response to nanowire implantations in the rat striatum after 1, 6, and 12 weeks using immunohistochemistry. The nanowires could be visualized in the scar by confocal microscopy (through the scattered laser light). For the nanowire-implanted animals, there is a significant astrocyte response at week 1 compared to controls. The nanowires are phagocytized by ED1 positive microglia, and some of them are degraded and/or transported away from the brain.


  • Soft tissue reactions evoked by implanted gallium phosphide

    by Cecilia E. Linsmeier, Lars Wallman, Linda Faxius, Jens Schouenborg, Lars M. Bjursten, Nils Danielsen