Philippe Hernigou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Philippe Hernigou has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Poignard
Université Paris-Est, Faculté de médecine, Laboratoire de "Bioingénierie cellulaire, tissulaire et sanguine", EA3952, 5 rue Gustave Eiffel, 94000, Créteil, France.
2 shared publications Ali De Moura
1 shared publicationAnis Chouk
1 shared publicationFrançoise Beaujean
1 shared publicationG Deschamps
1 shared publicationGilles Mathieu
1 shared publication
Latest Publications
- Open Access
- 17 March 2011
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 3 (1) , 2
Enlarged transacromial superior approach with reverse shoulder arthroplasty for fractures
The authors describe a step-by-step technique for reverse total shoulder arthroplasty using arthrotomy via the enlarged transacromial superior approach. This technique seems ideal for reinsertion of the tuberosities and to ensure adequate postoperative tensional balance of the infraspinatus and the subscapularis, which is critical for the rotator cuffs to function properly and to achieve optimal arthroplasty stability. Reviewing these different steps helps understanding each rotator cuff individual component's contribution to achieve optimal arthroplasty stability and external rotation with a reverse shoulder arthroplasty.
- 17 March 2011
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 3 (1) , 2
Open AccessEnlarged transacromial superior approach with reverse shoulder arthroplasty for fractures
The authors describe a step-by-step technique for reverse total shoulder arthroplasty using arthrotomy via the enlarged transacromial superior approach. This technique seems ideal for reinsertion of the tuberosities and to ensure adequate postoperative tensional balance of the infraspinatus and the subscapularis, which is critical for the rotator cuffs to function properly and to achieve optimal arthroplasty stability. Reviewing these different steps helps understanding each rotator cuff individual component's contribution to achieve optimal arthroplasty stability and external rotation with a reverse shoulder arthroplasty.
- 1 November 2007
- Published by Elsevier in Revue de Chirurgie Orthopedique Et Reparatrice de L'appareil Moteur
- Vol. 93 (7) , 133-134
244 Histoire naturelle de l’inégalité de longueur après prothèse totale de hanche durant la première année
- 1 November 2007
- Published by Elsevier in Revue de Chirurgie Orthopedique Et Reparatrice de L'appareil Moteur
- Vol. 93 (7) , 133-134
244 Histoire naturelle de l’inégalité de longueur après prothèse totale de hanche durant la première année
- 1 June 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 423 (423) , 161-165
Alignment Influences Wear in the Knee after Medial Unicompartmental Arthroplasty
Failure of a medial unicompartmental arthroplasty may be related to wear of the cartilage in the opposite compartment or to wear in the polyethylene tibial implant. Limb alignment influences both of these factors in the long term. Fifty-eight knees with medial unicompartmental arthroplasties in patients alive at least 10 years postoperatively were evaluated for radiographic changes at their most recent followup. The average duration of clinical and radiographic followups for these patients was 15 years (range, 10–20 years). Alignment was measured preoperatively and postoperatively as the hip-knee-ankle angle on radiographs of the entire limb. An overcorrection in valgus of the preoperative deformity (hip-knee-ankle angle > 180°) was associated with an increased risk of degenerative changes in the opposite compartment. Severe undercorrection in varus of the deformity (hip-knee-ankle angle < 170°) was associated with increased wear in the tibial component and recurrence of the deformity which was indicative of polyethylene wear. For medial implants that were implanted in moderate varus (hip-knee-ankle angle of 171° to 179°) the rate of wear of the polyethylene was less than in knees with severe undercorrection and the risk of degenerative changes in the opposite compartment was low.
- 1 June 2004
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 423 (423) , 161-165
Alignment Influences Wear in the Knee after Medial Unicompartmental Arthroplasty
Failure of a medial unicompartmental arthroplasty may be related to wear of the cartilage in the opposite compartment or to wear in the polyethylene tibial implant. Limb alignment influences both of these factors in the long term. Fifty-eight knees with medial unicompartmental arthroplasties in patients alive at least 10 years postoperatively were evaluated for radiographic changes at their most recent followup. The average duration of clinical and radiographic followups for these patients was 15 years (range, 10–20 years). Alignment was measured preoperatively and postoperatively as the hip-knee-ankle angle on radiographs of the entire limb. An overcorrection in valgus of the preoperative deformity (hip-knee-ankle angle > 180°) was associated with an increased risk of degenerative changes in the opposite compartment. Severe undercorrection in varus of the deformity (hip-knee-ankle angle < 170°) was associated with increased wear in the tibial component and recurrence of the deformity which was indicative of polyethylene wear. For medial implants that were implanted in moderate varus (hip-knee-ankle angle of 171° to 179°) the rate of wear of the polyethylene was less than in knees with severe undercorrection and the risk of degenerative changes in the opposite compartment was low.
- Top Cited Papers
- 1 December 2002
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 405 (405) , 14-23
Treatment of Osteonecrosis With Autologous Bone Marrow Grafting
Core decompression with bone graft is used frequently in the treatment of osteonecrosis of the femoral head. Many different techniques have been described. In the current series, grafting was done with autologous bone marrow obtained from the iliac crest of patients operated on for osteonecrosis of the hip. The results of a prospective study of 189 hips in 116 patients treated with core decompression and autologous bone marrow grafting are reported. Patients were followed up from 5 to 10 years. The outcome was determined by the changes in the Harris hip score, by progression in radiographic stages, and by the need for hip replacement. The bone marrow was harvested with the patient under general anesthesia. The usual sites were the anterior iliac crests. The aspirated marrow was reduced in volume by concentration and injected into the femoral head after core decompression with a small trocar. When patients were operated on before collapse (Stage I and Stage II), hip replacement was done in nine of the 145 hips. Total hip replacement was necessary in 25 hips among the 44 hips operated on after collapse (Stage III and Stage IV). To measure the number of progenitor cells transplanted, the fibroblast colony forming unit was used as an indicator of the stroma cell activity. Patients who had the greater number of progenitor cells transplanted in their hips had better outcomes.
- 1 December 2002
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 405 (405) , 14-23
Top Cited PapersTreatment of Osteonecrosis With Autologous Bone Marrow Grafting
Core decompression with bone graft is used frequently in the treatment of osteonecrosis of the femoral head. Many different techniques have been described. In the current series, grafting was done with autologous bone marrow obtained from the iliac crest of patients operated on for osteonecrosis of the hip. The results of a prospective study of 189 hips in 116 patients treated with core decompression and autologous bone marrow grafting are reported. Patients were followed up from 5 to 10 years. The outcome was determined by the changes in the Harris hip score, by progression in radiographic stages, and by the need for hip replacement. The bone marrow was harvested with the patient under general anesthesia. The usual sites were the anterior iliac crests. The aspirated marrow was reduced in volume by concentration and injected into the femoral head after core decompression with a small trocar. When patients were operated on before collapse (Stage I and Stage II), hip replacement was done in nine of the 145 hips. Total hip replacement was necessary in 25 hips among the 44 hips operated on after collapse (Stage III and Stage IV). To measure the number of progenitor cells transplanted, the fibroblast colony forming unit was used as an indicator of the stroma cell activity. Patients who had the greater number of progenitor cells transplanted in their hips had better outcomes.
- 1 January 2002
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 73 (2) , 140-143
Unrecognized shoulder joint penetration during fixation of proximal fractures of the humerus
In osteosynthesis of proximal humerus fractures, the screws frequently penetrate the joint. Using orthogonal frontal and lateral radiographs, we found unrecognized pin penetration in 8 of 30 patients during fixation of unstable neck fractures of the humerus.
- 1 January 2002
- Published by Medical Journals Sweden AB in Acta Orthopaedica
- Vol. 73 (2) , 140-143
Unrecognized shoulder joint penetration during fixation of proximal fractures of the humerus
In osteosynthesis of proximal humerus fractures, the screws frequently penetrate the joint. Using orthogonal frontal and lateral radiographs, we found unrecognized pin penetration in 8 of 30 patients during fixation of unstable neck fractures of the humerus.