Michael H. Bonnet
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael H. Bonnet has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Donna L. Arand
Dayton Department of Veterans Affairs Medical Center, Wright State University, and Kettering Medical Center, Dayton, OH
8 shared publicationsD L Arand
2 shared publicationsD. L. Arand
From the Dayton Department of Veterans Affairs Medical Center, Wright State University, Kettering Medical Center, and Wallace Kettering Neuroscience Institute, Dayton, OH, USA
2 shared publicationsAndrew L. Chesson
LSU Health Science Center — Shreveport, Department of Neurology and Office of the Dean, Shreveport, LA
1 shared publicationArthur S. Walters
Seton Hall University School of Graduate Medical Education, New Jersey Neuroscience Institute at JFK Medical Center, Edison, NJ
1 shared publicationEdward J. Stepanski
Rush University Medical Center, Chicago, IL
1 shared publication
Latest Publications
- 15 March 2007
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 3 (2) , 133-145
The Scoring of Arousal in Sleep: Reliability, Validity, and Alternatives
The reliability and validity of EEG arousals and other types of arousal are reviewed. Brief arousals during sleep had been observed for many years, but the evolution of sleep medicine in the 1980s directed new attention to these events. Early studies at that time in animals and humans linked brief EEG arousals and associated fragmentation of sleep to daytime sleepiness and degraded performance. Increasing interest in scoring of EEG arousals led the ASDA to publish a scoring manual in 1992. The current review summarizes numerous studies that have examined scoring reliability for these EEG arousals. Validity of EEG arousals was explored by review of studies that empirically varied arousals and found deficits similar to those found after total sleep deprivation depending upon the rate and extent of sleep fragmentation. Additional data from patients with clinical sleep disorders prior to and after effective treatment has also shown a continuing relationship between reduction in pathology-related arousals and improved sleep and daytime function. Finally, many suggestions have been made to refine arousal scoring to include additional elements (e.g., CAP), change the time frame, or focus on other physiological responses such as heart rate or blood pressure changes. Evidence to support the reliability and validity of these measures is presented. It was concluded that the scoring of EEG arousals has added much to our understanding of the sleep process but that significant work on the neurophysiology of arousal needs to be done. Additional refinement of arousal scoring will provide improved insight into sleep pathology and recovery.
- 15 March 2007
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 3 (2) , 133-145
The Scoring of Arousal in Sleep: Reliability, Validity, and Alternatives
The reliability and validity of EEG arousals and other types of arousal are reviewed. Brief arousals during sleep had been observed for many years, but the evolution of sleep medicine in the 1980s directed new attention to these events. Early studies at that time in animals and humans linked brief EEG arousals and associated fragmentation of sleep to daytime sleepiness and degraded performance. Increasing interest in scoring of EEG arousals led the ASDA to publish a scoring manual in 1992. The current review summarizes numerous studies that have examined scoring reliability for these EEG arousals. Validity of EEG arousals was explored by review of studies that empirically varied arousals and found deficits similar to those found after total sleep deprivation depending upon the rate and extent of sleep fragmentation. Additional data from patients with clinical sleep disorders prior to and after effective treatment has also shown a continuing relationship between reduction in pathology-related arousals and improved sleep and daytime function. Finally, many suggestions have been made to refine arousal scoring to include additional elements (e.g., CAP), change the time frame, or focus on other physiological responses such as heart rate or blood pressure changes. Evidence to support the reliability and validity of these measures is presented. It was concluded that the scoring of EEG arousals has added much to our understanding of the sleep process but that significant work on the neurophysiology of arousal needs to be done. Additional refinement of arousal scoring will provide improved insight into sleep pathology and recovery.
- Open Access
- 1 June 2005
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 28 (6) , 685-693
Performance and Cardiovascular Measures in Normal Adults with Extreme MSLT Scores and Subjective Sleepiness Levels
The purpose of this study was to determine the relationship of subjective and objective sleepiness across several nights. Extreme groups were chosen based upon both Multiple Sleep Latency Test (MSLT) findings and report of characteristic subjective sleepiness, and groups were compared across sleep, demographic, performance, and physiologic variables. Subjects spent 3 baseline nights and the following days in the laboratory. Standard polysomnographic recordings were made on each night. On each day, subjects had an MSLT, performance testing, and metabolic and heart rate observation periods. Participants were 50 adult normal sleepers. None. Those subjects with sleep latencies on the MSLT of more than 10 minutes following the adaptation night (Alert) were compared with 2 groups of subjects with sleep latencies on the MSLT of less than 7 minutes following the adaptation night. Subjects with MSLT < 7 were divided into those who reported subjective sleepiness during the day (subjective sleepiness > 1 SD above the mean for the entire group—Sleepy-Sleepy) and those who did not report subjective sleepiness (subjective sleepiness < 1 SD above the mean for the entire group—Sleepy-Alert). The Alert group maintained longer sleep latencies than the other groups and had improved performance on vigilance compared to the Sleepy-Sleepy group on all days and on some days compared to the Sleepy-Alert group. Vigilance was improved in the Sleepy-Alert group compared with the Sleepy-Sleepy group on all days. The Alert group had higher heart rate and increased low/high spectral heart rate power compared to both sleepy groups, and the Sleepy-Alert group had higher heart rate and increased low/high spectral heart rate power compared to the Sleepy-Sleepy group at some points. It was concluded that normal adults with short MSLT latencies differ from those with longer latencies on both cardiac and performance variables. Also, those individuals with short latencies can be divided into subgroups claiming subjective sleepiness or denying sleepiness. Those denying sleepiness have improved vigilance performance and greater heart rate and low/high spectral heart rate power compared to those with subjective sleepiness. Both the MSLT group differences and the subjective group differences imply that ability to maintain wakefulness and performance in sedentary situations may be related to innate ability to maintain physiologic arousal.
- 1 June 2005
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 28 (6) , 685-693
Open AccessPerformance and Cardiovascular Measures in Normal Adults with Extreme MSLT Scores and Subjective Sleepiness Levels
The purpose of this study was to determine the relationship of subjective and objective sleepiness across several nights. Extreme groups were chosen based upon both Multiple Sleep Latency Test (MSLT) findings and report of characteristic subjective sleepiness, and groups were compared across sleep, demographic, performance, and physiologic variables. Subjects spent 3 baseline nights and the following days in the laboratory. Standard polysomnographic recordings were made on each night. On each day, subjects had an MSLT, performance testing, and metabolic and heart rate observation periods. Participants were 50 adult normal sleepers. None. Those subjects with sleep latencies on the MSLT of more than 10 minutes following the adaptation night (Alert) were compared with 2 groups of subjects with sleep latencies on the MSLT of less than 7 minutes following the adaptation night. Subjects with MSLT < 7 were divided into those who reported subjective sleepiness during the day (subjective sleepiness > 1 SD above the mean for the entire group—Sleepy-Sleepy) and those who did not report subjective sleepiness (subjective sleepiness < 1 SD above the mean for the entire group—Sleepy-Alert). The Alert group maintained longer sleep latencies than the other groups and had improved performance on vigilance compared to the Sleepy-Sleepy group on all days and on some days compared to the Sleepy-Alert group. Vigilance was improved in the Sleepy-Alert group compared with the Sleepy-Sleepy group on all days. The Alert group had higher heart rate and increased low/high spectral heart rate power compared to both sleepy groups, and the Sleepy-Alert group had higher heart rate and increased low/high spectral heart rate power compared to the Sleepy-Sleepy group at some points. It was concluded that normal adults with short MSLT latencies differ from those with longer latencies on both cardiac and performance variables. Also, those individuals with short latencies can be divided into subgroups claiming subjective sleepiness or denying sleepiness. Those denying sleepiness have improved vigilance performance and greater heart rate and low/high spectral heart rate power compared to those with subjective sleepiness. Both the MSLT group differences and the subjective group differences imply that ability to maintain wakefulness and performance in sedentary situations may be related to innate ability to maintain physiologic arousal.
- Open Access
- 1 December 2003
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 26 (8) , 1029-1036
Situational Insomnia: Consistency, Predictors, and Outcomes
The purpose of this study was to determine the consistency of situational insomnia across several stressful conditions, including the first night in the sleep laboratory, phase advance of sleep time by 3 hours, phase advance of sleep time by 6 hours, and administration of 400 mg of caffeine. The impact of situational insomnia on alertness, metabolic rate, and cardiac measures on the following day was also measured. Subjects spent 5 to 7 nights and the following days in the laboratory. Standard polysomnographic recordings were made on each night. On each day, subjects had a Multiple Sleep Latency Test, performance testing, and metabolic and heart-rate observation periods. Fifty adult normal sleepers. Subjects had 1 night with their sleep phase advanced by 3 hours, 1 night with sleep phase advanced by 6 hours, and 1 night with the administration of 400 mg of caffeine 30 minutes prior to lights out. Sleep efficiency was reduced and variability was increased in each of the stressful conditions, as predicted. Those subjects with the greatest sleep efficiency on the adaptation night (top 25%) were compared with those subjects with the lowest sleep efficiency on the adaptation night (bottom 25%). Those subjects with the poorest sleep on the adaptation night (situational insomnia) had normal sleep on the baseline night that followed but had significantly reduced sleep efficiency when their sleep was advanced or they were given caffeine. Those same subjects had a significant decrease on their Multiple Sleep Latency Test on the day following the 6-hour advance and a significant increase in their Multiple Sleep Latency Test on the day following caffeine administration. The good sleepers had no significant change in their Multiple Sleep Latency Test during any of the study conditions. In terms of demographic variables, the situational insomnia group used less alcohol and tended to include a higher percentage of men. The situational insomnia group also had an elevated heart rate and increased low-frequency and decreased high-frequency electrocardiographic spectral power compared to the good sleepers. Significant differences were not found on personality or historical reports of poor sleep. Normal young adults have a consistent response to various types of situational stress. Those individuals who respond with poor sleep may display increased sleepiness associated with their poor sleep but may also be more sensitive to the effects of caffeine. These individuals have cardiac changes consistent with sympathetic nervous system activation, and they may be at risk for developing insomnia and other associated disorders.
- 1 December 2003
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 26 (8) , 1029-1036
Open AccessSituational Insomnia: Consistency, Predictors, and Outcomes
The purpose of this study was to determine the consistency of situational insomnia across several stressful conditions, including the first night in the sleep laboratory, phase advance of sleep time by 3 hours, phase advance of sleep time by 6 hours, and administration of 400 mg of caffeine. The impact of situational insomnia on alertness, metabolic rate, and cardiac measures on the following day was also measured. Subjects spent 5 to 7 nights and the following days in the laboratory. Standard polysomnographic recordings were made on each night. On each day, subjects had a Multiple Sleep Latency Test, performance testing, and metabolic and heart-rate observation periods. Fifty adult normal sleepers. Subjects had 1 night with their sleep phase advanced by 3 hours, 1 night with sleep phase advanced by 6 hours, and 1 night with the administration of 400 mg of caffeine 30 minutes prior to lights out. Sleep efficiency was reduced and variability was increased in each of the stressful conditions, as predicted. Those subjects with the greatest sleep efficiency on the adaptation night (top 25%) were compared with those subjects with the lowest sleep efficiency on the adaptation night (bottom 25%). Those subjects with the poorest sleep on the adaptation night (situational insomnia) had normal sleep on the baseline night that followed but had significantly reduced sleep efficiency when their sleep was advanced or they were given caffeine. Those same subjects had a significant decrease on their Multiple Sleep Latency Test on the day following the 6-hour advance and a significant increase in their Multiple Sleep Latency Test on the day following caffeine administration. The good sleepers had no significant change in their Multiple Sleep Latency Test during any of the study conditions. In terms of demographic variables, the situational insomnia group used less alcohol and tended to include a higher percentage of men. The situational insomnia group also had an elevated heart rate and increased low-frequency and decreased high-frequency electrocardiographic spectral power compared to the good sleepers. Significant differences were not found on personality or historical reports of poor sleep. Normal young adults have a consistent response to various types of situational stress. Those individuals who respond with poor sleep may display increased sleepiness associated with their poor sleep but may also be more sensitive to the effects of caffeine. These individuals have cardiac changes consistent with sympathetic nervous system activation, and they may be at risk for developing insomnia and other associated disorders.
- 1 August 2003
- Published by Elsevier in Sleep Medicine Reviews
- Vol. 7 (4) , 297-310
Clinical effects of sleep fragmentation versus sleep deprivation
- 1 August 2003
- Published by Elsevier in Sleep Medicine Reviews
- Vol. 7 (4) , 297-310
Clinical effects of sleep fragmentation versus sleep deprivation
- 16 June 2003
- Published by Wiley in Journal of Internal Medicine
- Vol. 254 (1) , 23-31
Insomnia, metabolic rate and sleep restoration
: Bonnet MH, Arand DL (Wright State University, Kettering Medical Center, and Wallace Kettering Neuroscience Institute, Dayton, OH, USA). Insomnia, metabolic rate and sleep restoration (Minisymposium). J Intern Med 2003; 254:–.Studies have shown occasional evidence of increased physiological activity in patients with primary insomnia. We hypothesized that metabolic rate, as measured by overall oxygen use (), might be a more general index of increased physiological activity. An initial experiment found elevated both at night and during the day in patients with primary insomnia as compared with matched normal sleepers. A second experiment found significant but more modest increases in in patients with Sleep State Misperception Insomnia [who complain of poor sleep but who had normal sleep by electroencephalographic (EEG) criteria]. In a third experiment, normal young adults were given caffeine 400 mg three times per day (TID) for 1 week as a means of increasing and possibly producing other symptoms of insomnia. Participants developed many symptoms consistent with those seen in patients with primary insomnia (poor sleep, increased latency on the Multiple Sleep Latency Test, increasing fatigue despite physiological activation, and increased anxiety on the Minnesota Multiphasic Personality Inventory (MMPI)). In a final experiment, physiological arousal was again produced by caffeine to determine if sleep with elevated arousal would be less restorative. All subjects (Ss) slept for 3.5 h after being given 400 mg of caffeine. During 41 h of sleep deprivation that followed, there was no significant condition difference for the Multiple Sleep Latency Test or mood measures. The results provided only weak support for the idea that sleep is less restorative after physiological arousal.
- 16 June 2003
- Published by Wiley in Journal of Internal Medicine
- Vol. 254 (1) , 23-31
Insomnia, metabolic rate and sleep restoration
: Bonnet MH, Arand DL (Wright State University, Kettering Medical Center, and Wallace Kettering Neuroscience Institute, Dayton, OH, USA). Insomnia, metabolic rate and sleep restoration (Minisymposium). J Intern Med 2003; 254:–.Studies have shown occasional evidence of increased physiological activity in patients with primary insomnia. We hypothesized that metabolic rate, as measured by overall oxygen use (), might be a more general index of increased physiological activity. An initial experiment found elevated both at night and during the day in patients with primary insomnia as compared with matched normal sleepers. A second experiment found significant but more modest increases in in patients with Sleep State Misperception Insomnia [who complain of poor sleep but who had normal sleep by electroencephalographic (EEG) criteria]. In a third experiment, normal young adults were given caffeine 400 mg three times per day (TID) for 1 week as a means of increasing and possibly producing other symptoms of insomnia. Participants developed many symptoms consistent with those seen in patients with primary insomnia (poor sleep, increased latency on the Multiple Sleep Latency Test, increasing fatigue despite physiological activation, and increased anxiety on the Minnesota Multiphasic Personality Inventory (MMPI)). In a final experiment, physiological arousal was again produced by caffeine to determine if sleep with elevated arousal would be less restorative. All subjects (Ss) slept for 3.5 h after being given 400 mg of caffeine. During 41 h of sleep deprivation that followed, there was no significant condition difference for the Multiple Sleep Latency Test or mood measures. The results provided only weak support for the idea that sleep is less restorative after physiological arousal.
- 1 October 2001
- Published by Elsevier in Physiology & Behavior
- Vol. 74 (3) , 291-298
Impact of activity and arousal upon spectral EEG parameters
- 1 October 2001
- Published by Elsevier in Physiology & Behavior
- Vol. 74 (3) , 291-298
Impact of activity and arousal upon spectral EEG parameters
- Open Access
- 1 June 2001
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 24 (4) , 441-447
Arousal Components Which Differentiate the MWT from the MSLT*
The purpose of this study was to determine the relative contribution of the instruction to maintain wakefulness versus posture change as major components determining sleep latency in the MWT as compared to the MSLT. After adaptation, subjects spent 3 nights and the following days in the laboratory. On each day, Ss had eight sleep latency measurements including four sleep latency tests from two of the following conditions: Lay down and Sleep (MSLT); Lay down and stay Awake; Sit up and Sleep; Sit up and stay Awake (MWT); and sit in a chair in front of a Computer and stay awake. Participants were 14 young adult normal sleepers. NA Significant differences in sleep latency were found for each condition with respect to all of the others except that the Computer condition did not differ from the Sit-Awake condition. Means for conditions were: Lay-Sleep - 11.1 minutes; Sit-Sleep — 17.7 minutes; Lay-Awake — 21.7 minutes; Sit-Awake — 29.0 minutes; Computer — 30.1 minutes. Correlations between conditions declined as subjects sat up. The MWT differs from the MSLT by taking advantage of the arousal system (motivation and posture) to maintain alertness (i.e., increase sleep latency). These arousal effects are additive. MSLT results may not always correlate well with MWT results because the MWT measures the combined effects of the sleep and arousal systems while the MSLT, in ideal situations, measures only sleepiness.
- 1 June 2001
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 24 (4) , 441-447
Open AccessArousal Components Which Differentiate the MWT from the MSLT*
The purpose of this study was to determine the relative contribution of the instruction to maintain wakefulness versus posture change as major components determining sleep latency in the MWT as compared to the MSLT. After adaptation, subjects spent 3 nights and the following days in the laboratory. On each day, Ss had eight sleep latency measurements including four sleep latency tests from two of the following conditions: Lay down and Sleep (MSLT); Lay down and stay Awake; Sit up and Sleep; Sit up and stay Awake (MWT); and sit in a chair in front of a Computer and stay awake. Participants were 14 young adult normal sleepers. NA Significant differences in sleep latency were found for each condition with respect to all of the others except that the Computer condition did not differ from the Sit-Awake condition. Means for conditions were: Lay-Sleep - 11.1 minutes; Sit-Sleep — 17.7 minutes; Lay-Awake — 21.7 minutes; Sit-Awake — 29.0 minutes; Computer — 30.1 minutes. Correlations between conditions declined as subjects sat up. The MWT differs from the MSLT by taking advantage of the arousal system (motivation and posture) to maintain alertness (i.e., increase sleep latency). These arousal effects are additive. MSLT results may not always correlate well with MWT results because the MWT measures the combined effects of the sleep and arousal systems while the MSLT, in ideal situations, measures only sleepiness.
- Open Access
- 18 December 2000
- Published by Wiley in Journal of Sleep Research
- Vol. 9 (4) , 403-404
Differentiating sleep continuity effects from sleep stage effects
- 18 December 2000
- Published by Wiley in Journal of Sleep Research
- Vol. 9 (4) , 403-404
Open AccessDifferentiating sleep continuity effects from sleep stage effects
- 1 December 2000
- Published by Elsevier in Physiology & Behavior
- Vol. 71 (5) , 485-492
The impact of music upon sleep tendency as measured by the multiple sleep latency test and maintenance of wakefulness test
- 1 December 2000
- Published by Elsevier in Physiology & Behavior
- Vol. 71 (5) , 485-492
The impact of music upon sleep tendency as measured by the multiple sleep latency test and maintenance of wakefulness test
- Open Access
- 1 January 2000
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 23 (2) , 1-8
Activity, Arousal, and the MSLT in Patients with Insomnia
It has recently been shown that physiological arousal following walking increased sleep latencies during daytime naps as compared to sleep latencies following TV viewing. Patients with insomnia have been shown to have increased physiological arousal and to also have longer MSLT latencies. It was hypothesized that insomnia patients, who are at a higher state of physiological arousal, would be unable to relax while lying in bed and watching TV and therefore would have relatively longer sleep latencies in naps following TV watching (due to inability to relax) as compared to walking. Twelve patients with psychophysiological insomnia took Multiple Sleep Latency Tests after either watching television for 15 minutes or after a 5-minute walk following baseline, sleep deprivation, and recovery sleep conditions. Sleep Laboratory Twelve patients with psychophysiological insomnia Manipulation of state arousal and sleep deprivation Sleep latencies were significantly longer following the walk as compared to watching TV (11.9 vs. 6.9 min. respectively). Sleep latencies were 13.4 and 3.8 min. following baseline and sleep deprivation conditions. Heart period, used as a measure of physiological arousal, was significantly elevated throughout naps following the walk as compared to naps following TV viewing. Heart period was also significantly correlated with nap sleep latency. The insomnia patients in this study had significantly increased arousal, as measured by heart rate, and significantly longer sleep latencies after walking as compared to resting. The magnitude of these changes was similar to that seen in normal subjects in a previous study. These data, in concert with previous work, support the contention that measured sleep tendency is a combination of sleep drive and level of central nervous system arousal, where arousal has both state and trait components.
- 1 January 2000
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 23 (2) , 1-8
Open AccessActivity, Arousal, and the MSLT in Patients with Insomnia
It has recently been shown that physiological arousal following walking increased sleep latencies during daytime naps as compared to sleep latencies following TV viewing. Patients with insomnia have been shown to have increased physiological arousal and to also have longer MSLT latencies. It was hypothesized that insomnia patients, who are at a higher state of physiological arousal, would be unable to relax while lying in bed and watching TV and therefore would have relatively longer sleep latencies in naps following TV watching (due to inability to relax) as compared to walking. Twelve patients with psychophysiological insomnia took Multiple Sleep Latency Tests after either watching television for 15 minutes or after a 5-minute walk following baseline, sleep deprivation, and recovery sleep conditions. Sleep Laboratory Twelve patients with psychophysiological insomnia Manipulation of state arousal and sleep deprivation Sleep latencies were significantly longer following the walk as compared to watching TV (11.9 vs. 6.9 min. respectively). Sleep latencies were 13.4 and 3.8 min. following baseline and sleep deprivation conditions. Heart period, used as a measure of physiological arousal, was significantly elevated throughout naps following the walk as compared to naps following TV viewing. Heart period was also significantly correlated with nap sleep latency. The insomnia patients in this study had significantly increased arousal, as measured by heart rate, and significantly longer sleep latencies after walking as compared to resting. The magnitude of these changes was similar to that seen in normal subjects in a previous study. These data, in concert with previous work, support the contention that measured sleep tendency is a combination of sleep drive and level of central nervous system arousal, where arousal has both state and trait components.