MTMasakazu Teragaki

Masakazu Teragaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Masakazu Teragaki has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Miction-induced Hypertension Disclosed by Home Blood Pressure Measurement in a Patient with Small Paraganglioma

    by Masakazu Teragaki, Takayuki Yamamoto, Kota Hosomi, Youhei Tada, Keiko Maeda, Daisuke Nishiya, Chinami Miyazaki, Yasuhiro Takagi, Yuji Sakanoue, Yukio Nishida, et al.

    A 46-year-old woman complained of a 10-year history of headache, nausea, a precordial oppressive feeling and shortness of breath on miction. She had noted a marked elevation in her blood pressure after miction using home blood pressure measurement. Her catecholamine levels were less than twice the value of the normal upper limit. Several imaging modalities detected a urinary bladder tumor, and 123I- metaiodobenzylguanidine (MIBG) scintigraphy showed positive accumulation. The diagnosis of urinary bladder paraganglioma was confirmed by partial cystectomy. We must keep in mind that paroxysms and hypertension associated with miction are important diagnostic clues of pheochromocytoma/paraganglioma. Home blood pressure measurement was very useful for detecting hypertension in this case.


  • Open Access

    A Case of Warfarin-induced Eosinophilia

    by Masakazu Teragaki, Hitomi Kawano, Ryojiro Makino, Keisuke Inoue, Yoshinori Sai, Mitsuharu Hosono, Shigefumi Suehiro, Mikio Okamura

    Warfarin is widely used in clinical practice all over the world. We report a man in whom prominent eosinophilia appeared after the initiation of warfarin administration following aortic valve replacement. Laboratory data following the administration and discontinuation of warfarin suggested that this drug was responsible for the eosinophilia. It is important to recognize the possibility of warfarin-induced hypereosinophilia as a latent adverse effect even when there are no clinical signs or symptoms.


  • Quadricuspid Aortic Valve: Report of Three Cases

    by Masakazu Teragaki, Yosuke Sakai, Koichiro Asawa, Ryo Matsumoto, Noriaki Kasayuki, Koji Nakayama, Shinichi Tanizawa, Nobuyuki Tanaka, Shigefumi Suehiro, Junichi Yoshikawa


  • Detecting Viable Myocardium and Predicting Functional Improvement-Comparisons of Positron Emission Tomography, Rest-Redistribution Thallium-201 Single-Photon Emission Computed Tomography (SPECT), Exercise Thallium-201 Reinjection SPECT, I-123 BMIPP SPECT and Dobutamine Stress Echocardiography-

    by Tomoko Tani, Masakazu Teragaki, Hiroyuki Watanabe, Takashi Muro, Hiroyuki Yamagishi, Kaname Akioka, Minoru Yoshiyama, Kazuhide Takeuchi, Junichi Yoshikawa

    Low-dose dobutamine stress echocardiography (LDDE) has become a useful and safe method for identifying hibernating or stunned myocardium and for predicting improvement in wall motion after coronary revascularization. In the present study, fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET), rest-redistribution thallium-201 ((201)Tl) single-photon emission computed tomography (RR-Tl SPECT), (123)I-15-(p-iodophenyl)-3-(R,S)-methyl pentadecanoic acid (BMIPP) and LDDE were performed in 30 patients with acute myocardial infarction (AMI) at 10+/-3 days after the onset of AMI. Also, exercise (201)Tl reinjection SPECT (RI-Tl SPECT) was performed at 14+/-2 days. Follow-up echocardiography was performed 5+/-3 months later in all patients after interventional therapy for the assessment of functional recovery. Of the 390 segments analyzed by echocardiography, 110 (28%) had abnormal wall motion. There were no significant differences between RR-Tl SPECT and LDDE in sensitivity, specificity, positive predictive value and negative predictive value using the chi(2)-test; however, in akinetic segments, there was a significant difference in sensitivity. Among FDG-PET, RI-Tl SPECT, BMIPP and LDDE, there were significant differences in 3 variables. In akinetic segments, LDDE is superior to RR-Tl SPECT in sensitivity and to FDG-PET in specificity. In hypokinetic segments, LDDE is superior to RI-Tl SPECT and BMIPP in sensitivity, and to FDG-PET and BMIPP in specificity. LDDE could detect functional recovery of viable myocardium in the early period of AMI and can be performed easily and safely.


  • Prevalence of hepatitis C virus infection among patients with hypertrophic cardiomyopathy

    by Masakazu Teragaki, Shuhei Nishiguchi, Kazuhide Takeuchi, Minoru Yoshiyama, Kaname Akioka, Junichi Yoshikawa


  • Coronary flow reserve correlates left ventricular diastolic dysfunction in patients with dilated cardiomyopathy

    by Masakazu Teragaki, Shiro Yanagi, Iku Toda, Kazuo Sakamoto, Kazuyoshi Hirota, Kazuhide Takeuchi, Junichi Yoshikawa


  • Open Access

    New applications of intracardiac echocardiography: assessment of coronary blood flow by colour and pulsed Doppler imaging in dogs

    by M Teragaki, I Toda, M Takagi, S Fukuda, K Ujino, K Takeuchi, J Yoshikawa

    Objective: To explore the application of a new 10 French intracardiac echocardiography (ICE) catheter with phased array and Doppler capable transducer for the assessment of epicardial and intramyocardial coronary blood flow. Methods: The coronary arteries were detected by cross sectional imaging in seven closed chest dogs, and coronary blood flow visualised by colour Doppler. Blood flow velocities were recorded by pulsed Doppler at baseline for reproducibility of repeated measurements, and during hyperaemia for coronary flow reserve measurements. Comparisons were made with Doppler guide wire data obtained simultaneously. Intramyocardial coronary artery blood flow was assessed by colour flow mapping, and the blood flow velocities recorded using pulsed Doppler at baseline and during hyperaemia. Results: Seven left main, six left anterior descending, seven left circumflex, and five right coronary arteries were visualised in the seven animals by cross sectional or colour Doppler imaging. Repeated measurements of coronary flow velocity showed a good correlation (mean diastolic velocity, r = 0.93, n = 22, p < 0.0001; peak diastolic velocity, r = 0.96, n = 22, p < 0.0001, respectively). Intraobserver/interobserver variability was satisfactorily low. Coronary flow reserve from ICE correlated highly with the value obtained from the Doppler guide wire (r = 0.90, n = 26, p < 0.0001). Intramyocardial coronary blood flow was identified in all seven dogs, and flow velocities were recorded at baseline and during hyperaemia in four animals. Conclusions: This new ICE catheter provides high quality diagnostic resolution. It is useful for coronary blood flow assessment.


    • 1 April 2002
      • Vol. 43  (4) , 443-50

    Incremental value of assessment of regional wall motion for detection of multivessel coronary artery disease in exercise (201)Tl gated myocardial perfusion imaging.

    by Naoya Shirai, Hiroyuki Yamagishi, Minoru Yoshiyama, Masakazu Teragaki, Kaname Akioka, Kazuhide Takeuchi, Junichi Yoshikawa, Hironobu Ochi

    Assessment of reversible perfusion defects in exercise (201)Tl perfusion SPECT has low sensitivity and high specificity for detection of multivessel coronary artery disease (CAD). The goal of this study was to evaluate whether worsening of left ventricular regional wall motion assessed by an automated algorithm in exercise (201)Tl electrocardiography-gated SPECT had incremental diagnostic value over perfusion data for detection of multivessel CAD. Two hundred one patients underwent exercise (201)Tl gated SPECT. Software that automatically analyzes left ventricular function was used to assess exercise and rest regional wall motion. Regional wall motion on initial images was compared with that on rest images, that is, delayed images for patients without reinjection images and reinjection images for patients with reinjection images. The left ventricle was divided into 9 segments, with individual segments assigned to 3 coronary territories. Worsening of wall motion was defined as worsening in any segment on initial images compared with rest images. Of 73 patients with multivessel CAD, 20 (27.4%) had reversible perfusion defects in multiple coronary territories, 26 (35.6%) exhibited worsening of regional wall motion in multiple territories, and 37 (50.7%) had reversible perfusion defects or worsening of regional wall motion in multiple territories. The sensitivity of the combination of reversible perfusion defect and worsening of regional wall motion was significantly higher than that of reversible perfusion defect alone for detection of multivessel CAD (50.7% vs. 27.4%, P < 0.05). The specificity of the combination of reversible perfusion defect and worsening of regional wall motion for detecting multivessel CAD did not differ from that of reversible perfusion defect alone and that of worsening of regional wall motion alone (94.5% vs. 99.2% and 97.7%, respectively, P = not statistically significant). Combined assessment of worsening of left ventricular regional wall motion by exercise and perfusion data in exercise (201)Tl gated myocardial SPECT was more sensitive, with acceptable specificity, than was assessment with perfusion data alone for detection of multivessel CAD.


    • 1 February 2002
      • Vol. 43  (2) , 131-9

    Incremental value of left ventricular ejection fraction for detection of multivessel coronary artery disease in exercise (201)Tl gated myocardial perfusion imaging.

    by Hiroyuki Yamagishi, Naoya Shirai, Minoru Yoshiyama, Masakazu Teragaki, Kaname Akioka, Kazuhide Takeuchi, Junichi Yoshikawa, Hironobu Ochi

    Assessment of reversible defects in exercise (201)Tl perfusion SPECT has low sensitivity and high specificity for detection of multivessel coronary artery disease (CAD). The goal of this study was to evaluate whether the left ventricular ejection fraction (LVEF) in exercise (201)Tl gated SPECT had incremental diagnostic value over perfusion data for detection of multivessel CAD. One hundred eighty-two patients underwent exercise (201)Tl gated SPECT. Automated LV function analysis software was used for calculation of the postexercise and the rest LVEF. The best threshold between 0- to 1-vessel CAD and 2- to 3-vessel CAD was determined as the cutoff that on receiver-operating-characteristic analysis resulted in the best sensitivity for detection of multivessel CAD with an associated specificity of >90%. Only 18 (26.9%) of 67 patients with multivessel CAD had reversible defects in multiple territories. Sensitivities of the postexercise and the rest LVEF and the worsening of the LVEF by exercise did not differ from those of perfusion data alone. Sensitivities of the combination of perfusion data and the postexercise and rest LVEF did not differ from those of perfusion data alone, whereas the sensitivity of the combination of perfusion data and worsening of the LVEF (i.e., reversible defects in multiple territories or worsening of the LVEF >5.6% [or both]) was significantly greater than that of perfusion data alone (43.3% vs. 26.9%; P < 0.05), with an acceptable level of specificity (90.4%). The worsening of the LVEF by exercise has the potential to detect patients with multivessel CAD among those without multivessel patterns of reversible defects.


  • Prediction of Functional Recovery in Patients With Myocardial Infarction After Revascularization

    by Tomoko Tani, Masakazu Teragaki, Hiroyuki Watanabe, Takashi Muro, Hiroyuki Yamagishi, Kaname Akioka, Kazuhide Takeuchi, Junichi Yoshikawa

    The present study investigated the agreement between low-dose dobutamine stress echocardiography (LDDSE) and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and compared each technique's ability to detect myocardial viability and predict functional recovery in 30 patients. All patients underwent revascularization, followed by echocardiography 5+/-3 months. Of the 390 segments analyzed by echocardiography before revascularization, 110 (28%) had abnormal wall motion. LDDSE showed viability in 66 sites of the 110 dyssynergic segments and 58 of these viable segments recovered their wall motion. With FDG-PET, 78 of the 110 dyssynergic segments were diagnosed as viable and 62 of these showed improvement of the wall motion. The sensitivities for LDDSE and FDG-PET to assess functional recovery were 84% and 90%, respectively; specificities were 80% and 64%, respectively. Positive predictive values for LDDSE and FDG-PET were 88% and 79%; negative predictive values were 75% and 78%, respectively. Both methods had good sensitivity for detecting improvement in regional function after revascularization, but LDDSE had a higher specificity for detecting viability and a better positive predictive value for left ventricular functional recovery.