Fred H. M. Wittkampf
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fred H. M. Wittkampf has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Arthur A. M. Wilde
From the Heart Lung Institute (F.H.M.W., E.F.D.W., R.D., H.R., R.N.W.H., E.O.R.d.M.), Department of Cardiology, University Hospital Utrecht, Utrecht, Netherlands, and Department of Cardiology (A.A.M.W.), Academic Medical Center, Amsterdam, Netherlands
1 shared publicationEric F. D. Wever
From the Heart Lung Institute (F.H.M.W., E.F.D.W., R.D., H.R., R.N.W.H., E.O.R.d.M.), Department of Cardiology, University Hospital Utrecht, Utrecht, Netherlands, and Department of Cardiology (A.A.M.W.), Academic Medical Center, Amsterdam, Netherlands
1 shared publicationEric F.D. Wever
Departments of Cardiology and Radiology, Heart Lung Center Utrecht, The Netherlands
1 shared publicationEtienne O. Robles DE Medina
Departments of Cardiology and Radiology, Heart Lung Center Utrecht, The Netherlands
1 shared publicationEtienne O. Robles de Medina
From the Heart Lung Institute (F.H.M.W., E.F.D.W., R.D., H.R., R.N.W.H., E.O.R.d.M.), Department of Cardiology, University Hospital Utrecht, Utrecht, Netherlands, and Department of Cardiology (A.A.M.W.), Academic Medical Center, Amsterdam, Netherlands
1 shared publicationHemanth Ramanna
From the Heart Lung Institute (F.H.M.W., E.F.D.W., R.D., H.R., R.N.W.H., E.O.R.d.M.), Department of Cardiology, University Hospital Utrecht, Utrecht, Netherlands, and Department of Cardiology (A.A.M.W.), Academic Medical Center, Amsterdam, Netherlands
1 shared publication
Latest Publications
- 1 November 2000
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 23 (11) , 1638-1644
Reduction of Radiation Exposure in the Cardiac Electrophysiology Laboratory
WITTKAMPF, F.H.M., et al. Reduction of Radiation Exposure in the Cardiac Electrophysiology Laboratory. The purpose of this study was to determine the effects of various protective measures on patient and operator radiation dose levels in catheter ablation procedures. Catheter ablation procedures are associated with significant radiation levels. The patient's skin and operator radiation levels were measured (1) at baseline, (2) after primary beam filtration by 0.3‐mm copper sheet and 2‐mm aluminium plate and implementation of the LocaLisa system, and (3) after reduction of the left anterior oblique fluoroscopic pulse rate and installation of a lead glass screen. Additionally, a comparative analysis of radiation exposure levels was performed in the seven Dutch catheter ablation centers. Filtration of both primary beams resulted in a more than two‐fold reduction in patient skin dose. Together with the LocaLisa system, this resulted in a six‐fold reduction in patient and operator dose. As expected, lowering of the left anterior oblique pulse rate from 25 to 12.5 Hz reduced the corresponding patient skin dose with a factor 2 while the leadglass protection caused an extra factor 2 reduction for the operator. Large differences were observed between fluoroscopy systems used for catheter ablation in the Netherlands. Depending on patient body mass and fluoroscopy system, patient skin dose varied between 0.2 and 8.4 Gy/hour. Proper measures may allow for a significant reduction of patient and operator radiation exposure in catheter ablation procedures. The large influence of body mass and equipment on patient's skin dose requires a more direct monitoring of skin dose than total fluoroscopy time.
- 1 November 2000
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 23 (11) , 1638-1644
Reduction of Radiation Exposure in the Cardiac Electrophysiology Laboratory
WITTKAMPF, F.H.M., et al. Reduction of Radiation Exposure in the Cardiac Electrophysiology Laboratory. The purpose of this study was to determine the effects of various protective measures on patient and operator radiation dose levels in catheter ablation procedures. Catheter ablation procedures are associated with significant radiation levels. The patient's skin and operator radiation levels were measured (1) at baseline, (2) after primary beam filtration by 0.3‐mm copper sheet and 2‐mm aluminium plate and implementation of the LocaLisa system, and (3) after reduction of the left anterior oblique fluoroscopic pulse rate and installation of a lead glass screen. Additionally, a comparative analysis of radiation exposure levels was performed in the seven Dutch catheter ablation centers. Filtration of both primary beams resulted in a more than two‐fold reduction in patient skin dose. Together with the LocaLisa system, this resulted in a six‐fold reduction in patient and operator dose. As expected, lowering of the left anterior oblique pulse rate from 25 to 12.5 Hz reduced the corresponding patient skin dose with a factor 2 while the leadglass protection caused an extra factor 2 reduction for the operator. Large differences were observed between fluoroscopy systems used for catheter ablation in the Netherlands. Depending on patient body mass and fluoroscopy system, patient skin dose varied between 0.2 and 8.4 Gy/hour. Proper measures may allow for a significant reduction of patient and operator radiation exposure in catheter ablation procedures. The large influence of body mass and equipment on patient's skin dose requires a more direct monitoring of skin dose than total fluoroscopy time.
- 16 March 1999
- Published by Wolters Kluwer Health in Circulation
- Vol. 99 (10) , 1312-1317
LocaLisa
Background —Estimation of the 3-dimensional (3D) position of ablation electrodes from fluoroscopic images is inadequate if a systematic lesion pattern is required in the treatment of complex arrhythmogenic substrates. Methods and Results —We developed a new technique for online 3D localization of intracardiac electrodes. Regular catheter electrodes are used as sensors for a high-frequency transthoracic electrical field, which is applied via standard skin electrodes. We investigated localization accuracy within the right atrium, right ventricle, and left ventricle by comparing measured and true interelectrode distances of a decapolar catheter. Long-term stability was analyzed by localization of the most proximal His bundle before and after slow pathway ablation. Electrogram recordings were unaffected by the applied electrical field. Localization data from 3 catheter positions, widely distributed within the right atrium, right ventricle, or left ventricle, were analyzed in 10 patients per group. The relationship between measured and true electrode positions was highly linear, with an average correlation coefficient of 0.996, 0.997, and 0.999 for the right atrium, right ventricle, and left ventricle, respectively. Localization accuracy was better than 2 mm, with an additional scaling error of 8% to 14%. After 2 hours, localization of the proximal His bundle was reproducible within 1.4±1.1 mm. Conclusions —This new technique enables accurate and reproducible real-time localization of electrode positions in cardiac mapping and ablation procedures. Its application does not distort the quality of electrograms and can be applied to any electrode catheter.
- 16 March 1999
- Published by Wolters Kluwer Health in Circulation
- Vol. 99 (10) , 1312-1317
LocaLisa
Background —Estimation of the 3-dimensional (3D) position of ablation electrodes from fluoroscopic images is inadequate if a systematic lesion pattern is required in the treatment of complex arrhythmogenic substrates. Methods and Results —We developed a new technique for online 3D localization of intracardiac electrodes. Regular catheter electrodes are used as sensors for a high-frequency transthoracic electrical field, which is applied via standard skin electrodes. We investigated localization accuracy within the right atrium, right ventricle, and left ventricle by comparing measured and true interelectrode distances of a decapolar catheter. Long-term stability was analyzed by localization of the most proximal His bundle before and after slow pathway ablation. Electrogram recordings were unaffected by the applied electrical field. Localization data from 3 catheter positions, widely distributed within the right atrium, right ventricle, or left ventricle, were analyzed in 10 patients per group. The relationship between measured and true electrode positions was highly linear, with an average correlation coefficient of 0.996, 0.997, and 0.999 for the right atrium, right ventricle, and left ventricle, respectively. Localization accuracy was better than 2 mm, with an additional scaling error of 8% to 14%. After 2 hours, localization of the proximal His bundle was reproducible within 1.4±1.1 mm. Conclusions —This new technique enables accurate and reproducible real-time localization of electrode positions in cardiac mapping and ablation procedures. Its application does not distort the quality of electrograms and can be applied to any electrode catheter.