Nedim Sarifakioglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nedim Sarifakioglu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Ahmet Terzioglu
Ankara Training and Research Hospital, Plastic and Reconstructive Surgery Department, Ankara, Turkey
2 shared publicationsGurcan Aslan
Ankara Training and Research Hospital, Plastic and Reconstructive Surgery Department, Ankara, Turkey
2 shared publicationsA. Terzioglu
Ankara Training and Research Hospital
1 shared publicationBulent Cigsar
Ankara Training and Research Hospital, Plastic and Reconstructive Surgery Department, Ankara, Turkey
1 shared publicationEvren Sarifakioglu
1 shared publicationF. Bingul
Ankara Training and Research Hospital
1 shared publication
Latest Publications
- 1 March 2006
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 117 (3) , 1043
The All-Purpose Towel Clamp: Old Toy, New Tasks!
- 1 March 2006
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 117 (3) , 1043
The All-Purpose Towel Clamp: Old Toy, New Tasks!
- 1 April 2005
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 115 (4) , 1087-1094
The Fate of Transplanted Fibrous Capsule as an Autogenous Graft
Background: In reconstructive and aesthetic surgery, several autogenous graft materials and biomaterials are available for soft-tissue augmentation, but none has all the properties of the ideal filler material. The common problem is that heterogeneous material is reactive, and the problem for the autogenous grafts is resorption. Methods: In this experimental study, the authors examined the transformation that the autogenous graft undergoes in a different location when it is used as a capsule tissue in place of silicone. Whole/diced capsule and fat grafts were evaluated at 3, 6, 9, and 12 months for their volume, weight, and histopathologic and statistical bases. Results: The capsule graft was observed at month 12 as a dense collagen bulk. When it had decreased by 25.6 percent in volume at the end of the 12-month period, the decrease in weight was found to be 20 percent. The resorption rates in diced capsule grafts were 14 percent of volume and 8.6 percent of weight. The volume-based rate of resorption was even lower (63 percent) for the capsule than for the fat, and the weight-based rate of resorption was even lower (70 percent) for the capsule. Conclusions: The low rate of resorption in capsule grafts was attributed to the environmental conditions that triggered the potential cause of resorption, such as inflammation in the localization conditions when it is was carried from the region where it was formed. The results indicate that in the new localization of the capsule tissue that is developed against silicone, it behaves as an autogenous graft that it is resorbed at a lower rate.
- 1 April 2005
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 115 (4) , 1087-1094
The Fate of Transplanted Fibrous Capsule as an Autogenous Graft
Background: In reconstructive and aesthetic surgery, several autogenous graft materials and biomaterials are available for soft-tissue augmentation, but none has all the properties of the ideal filler material. The common problem is that heterogeneous material is reactive, and the problem for the autogenous grafts is resorption. Methods: In this experimental study, the authors examined the transformation that the autogenous graft undergoes in a different location when it is used as a capsule tissue in place of silicone. Whole/diced capsule and fat grafts were evaluated at 3, 6, 9, and 12 months for their volume, weight, and histopathologic and statistical bases. Results: The capsule graft was observed at month 12 as a dense collagen bulk. When it had decreased by 25.6 percent in volume at the end of the 12-month period, the decrease in weight was found to be 20 percent. The resorption rates in diced capsule grafts were 14 percent of volume and 8.6 percent of weight. The volume-based rate of resorption was even lower (63 percent) for the capsule than for the fat, and the weight-based rate of resorption was even lower (70 percent) for the capsule. Conclusions: The low rate of resorption in capsule grafts was attributed to the environmental conditions that triggered the potential cause of resorption, such as inflammation in the localization conditions when it is was carried from the region where it was formed. The results indicate that in the new localization of the capsule tissue that is developed against silicone, it behaves as an autogenous graft that it is resorbed at a lower rate.
- 1 December 2004
- Published by Elsevier in British Journal of Plastic Surgery
- Vol. 57 (8) , 769-772
The influence of sildenafil on random skin flap survival in rats: an experimental study
- 1 December 2004
- Published by Elsevier in British Journal of Plastic Surgery
- Vol. 57 (8) , 769-772
The influence of sildenafil on random skin flap survival in rats: an experimental study
- 1 December 2004
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 53 (6) , 543-546
Evaluating the Effects of Ice Application on the Pain Felt During Botulinum Toxin Type-A Injections
The pain felt during botulinum toxin type-A injections and the troubled and distressed treatment it induces is common and well known for the patient and the doctor applying the treatment. This problem is further intensified on the patients who have needle phobia. The effect of ice application on the treatment zone before botulinum toxin type-A treatment on the pain felt during injections is investigated. Totally, 24 patients who underwent botulinum toxin type-A treatment in upper face region for esthetic purposes are included in the study. Ice was applied 5 minutes before the injections on the right lateral orbital zones (crow's feet area) of the patients, whereas on their left sides, toxin was injected without applying any ice. All the drugs were diluted by normal saline; 5 U of active botulinum toxin type-A was used in each diziem (0.1 mL). Total injection number was determined both in right and left areas as 8. Visual analog scale (VAS) was used for pain intensity and evaluation. On the side where ice was applied, the treatment was completed in 1 session and lasted shorter when compared with that of the control side. However, the average VAS values defining the pain that the patients felt in their right and left sides were found as 1.1 and 5.9, respectively. The clinical findings obtained indicated that pain is significantly reduced on the side where ice is applied. The statistical significance of the test results were evaluated by Student's t test, and the difference between VAS values was found statistically significant (P = 0.000).
- 1 December 2004
- Published by Wolters Kluwer Health in Annals of Plastic Surgery
- Vol. 53 (6) , 543-546
Evaluating the Effects of Ice Application on the Pain Felt During Botulinum Toxin Type-A Injections
The pain felt during botulinum toxin type-A injections and the troubled and distressed treatment it induces is common and well known for the patient and the doctor applying the treatment. This problem is further intensified on the patients who have needle phobia. The effect of ice application on the treatment zone before botulinum toxin type-A treatment on the pain felt during injections is investigated. Totally, 24 patients who underwent botulinum toxin type-A treatment in upper face region for esthetic purposes are included in the study. Ice was applied 5 minutes before the injections on the right lateral orbital zones (crow's feet area) of the patients, whereas on their left sides, toxin was injected without applying any ice. All the drugs were diluted by normal saline; 5 U of active botulinum toxin type-A was used in each diziem (0.1 mL). Total injection number was determined both in right and left areas as 8. Visual analog scale (VAS) was used for pain intensity and evaluation. On the side where ice was applied, the treatment was completed in 1 session and lasted shorter when compared with that of the control side. However, the average VAS values defining the pain that the patients felt in their right and left sides were found as 1.1 and 5.9, respectively. The clinical findings obtained indicated that pain is significantly reduced on the side where ice is applied. The statistical significance of the test results were evaluated by Student's t test, and the difference between VAS values was found statistically significant (P = 0.000).
- 1 October 2004
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 114 (5) , 1355-1356
A PROTECTIVE, SECURE ALTERNATIVE IN SURGICAL OPERATIONS BRINGS EASE TO THE SURGEON: THE TEMPORARY USE OF STERILE, SEMIELASTIC, TEXTURED GLOVES
- 1 October 2004
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 114 (5) , 1355-1356
A PROTECTIVE, SECURE ALTERNATIVE IN SURGICAL OPERATIONS BRINGS EASE TO THE SURGEON: THE TEMPORARY USE OF STERILE, SEMIELASTIC, TEXTURED GLOVES
- 10 March 2004
- Published by Springer Nature in European Journal of Plastic Surgery
- Vol. 27 (1) , 46
Reappraisal of Penrose drain stabilization
- 10 March 2004
- Published by Springer Nature in European Journal of Plastic Surgery
- Vol. 27 (1) , 46
Reappraisal of Penrose drain stabilization
- 5 March 2004
- Published by Wolters Kluwer Health in Dermatologic Surgery
- Vol. 30 (3) , 395-398
EMLA and Ear Surgery: Is It Possible to Achieve Full-Thickness Anesthesia With EMLA?
Background. Topical local anesthetic applications offer painless, effective analgesia with slow onset but prolonged duration and minimal side effects. EMLA (Eczacibasi Pharmaceuticals, Istanbul, Turkey) is the most universally used topical local anesthetic. Objective. The aim of this prospective, randomized, double‐blind study is to evaluate the efficacy of EMLA on total anesthesia of the external ear. Methods. Twenty‐two patients with helical lesions were divided into two groups. Group A received EMLA on both the anterior and posterior surfaces of the ear, and group B received EMLA on only one side of the ear. After 120 minutes of occlusive dressing, the surgery was performed. The short form of the McGill Pain Questionnaire and a numerical visual analog scale were used to measure overall pain quality and intensity during and at the end of surgery. Results. Visual analog scale scores (four for group A and six for group B6) between two groups using Student's t‐test (p=0210) and concerning McGill Pain Questionnaire scores with Wilcoxon signed ranks test (p=0.058) between two groups showed no statistical significant difference. Conclusion. It seems that EMLA cream is not a good and first option for achieving full anesthesia on the ear because of its poor anesthetic effect. We do not consider EMLA cream to be clinically useful for major surgical attempt on the ear.
- 5 March 2004
- Published by Wolters Kluwer Health in Dermatologic Surgery
- Vol. 30 (3) , 395-398
EMLA and Ear Surgery: Is It Possible to Achieve Full-Thickness Anesthesia With EMLA?
Background. Topical local anesthetic applications offer painless, effective analgesia with slow onset but prolonged duration and minimal side effects. EMLA (Eczacibasi Pharmaceuticals, Istanbul, Turkey) is the most universally used topical local anesthetic. Objective. The aim of this prospective, randomized, double‐blind study is to evaluate the efficacy of EMLA on total anesthesia of the external ear. Methods. Twenty‐two patients with helical lesions were divided into two groups. Group A received EMLA on both the anterior and posterior surfaces of the ear, and group B received EMLA on only one side of the ear. After 120 minutes of occlusive dressing, the surgery was performed. The short form of the McGill Pain Questionnaire and a numerical visual analog scale were used to measure overall pain quality and intensity during and at the end of surgery. Results. Visual analog scale scores (four for group A and six for group B6) between two groups using Student's t‐test (p=0210) and concerning McGill Pain Questionnaire scores with Wilcoxon signed ranks test (p=0.058) between two groups showed no statistical significant difference. Conclusion. It seems that EMLA cream is not a good and first option for achieving full anesthesia on the ear because of its poor anesthetic effect. We do not consider EMLA cream to be clinically useful for major surgical attempt on the ear.
- 1 December 2003
- Published by Elsevier in British Journal of Plastic Surgery
- Vol. 56 (8) , 797-803
A hidden donor site for resurfacing finger tip defects: the ‘ring graft’
- 1 December 2003
- Published by Elsevier in British Journal of Plastic Surgery
- Vol. 56 (8) , 797-803
A hidden donor site for resurfacing finger tip defects: the ‘ring graft’