Darrah K. Sleeth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Darrah K. Sleeth has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Matthew Steven Thiese
From the Department of Family and Preventive Medicine, Rocky Mountain Center for Occupational and Environmental Health (M.S., A.P., M.S.T.); University of Utah, Salt Lake City, Utah
4 shared publications - Rodney R. Larson
Rocky Mountain Center for Occupational & Environmental Health, Department of Family & Preventive Medicine, University of Utah, Salt Lake City, UT 84108, USA
4 shared publications Leon F. Pahler
Rocky Mountain Center for Occupational & Environmental Health, Department of Family & Preventive Medicine, University of Utah , Salt Lake City , Utah
3 shared publications- Rachael M. Jones
Department of Environmental Health Sciences, Fielding School of Public Health, University of California , Los Angeles, CA
3 shared publications - Rod Handy
Department of Family & Preventive Medicine, University of Utah, Salt Lake City, UT 84108, USA
3 shared publications - Camie Schaefer
Division of Occupational and Environmental Health, Spencer Fox Eccles School of Medicine University of Utah Salt Lake City Utah USA
2 shared publications
Latest Publications
- 10 October 2026
- Published by Springer Nature in Current Environmental Health Reports
- Vol. 13 (1) , 45
Calibration of Low-Cost Particulate Matter Sensors for Exposure Assessment: A Critical Review
- 10 October 2026
- Published by Springer Nature in Current Environmental Health Reports
- Vol. 13 (1) , 45
Calibration of Low-Cost Particulate Matter Sensors for Exposure Assessment: A Critical Review
- 3 October 2026
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 23 (10) , 713-714
Introduction to the special issue collection of articles concerning aerosols
Aerosols in the workplace and other environments are important contributors to ill health. The articles in this special issue are a collection focusing on aerosols. These articles cover a wide rang...
- 3 October 2026
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 23 (10) , 713-714
Introduction to the special issue collection of articles concerning aerosols
Aerosols in the workplace and other environments are important contributors to ill health. The articles in this special issue are a collection focusing on aerosols. These articles cover a wide rang...
- Open Access
- 9 June 2026
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 23 (10) , 828-880
The basis for recommending the selection of samplers in determining occupational exposures to aerosols
Measurements are considered to be the basis of exposure assessments used to determine risks to workers. Inhalation exposure poses the greatest risk for most airborne chemicals, and measurements are based on collecting (sampling) and analyzing air samples. Samplers have been developed for more than 120 years. Each new design has been intended to address flaws perceived in earlier designs. Users are faced with a varied array of samplers from which to choose. Comparisons are difficult to make because tests of sampler performance were not standardized until recently and have not been applied consistently. The existing large body of work does allow some conclusions to be drawn regarding performance. Many samplers have been shown to work effectively with test aerosols under controlled conditions in the laboratory. Further testing in the field has shown that not all samplers perform equally well in every situation; for example, under different wind speeds and directions or with aerosols that maintain unusual physical characteristics. There is not one aerosol sampler that can be used for all situations. Further, the design of a sampler and how the sampler needs to be handled can have an enormous influence on the result. Quality of manufacture, material of construction, cost, reusability, ease of use, setting of flow rates, transportation issues, and wearer acceptability all have an impact on selecting from among different samplers with similar performance. The range of available samplers constitutes a toolkit from which the most appropriate sampler could be selected for a given specific situation. Common inhalable and respirable aerosol samplers are considered in respect of their history of design and manufacture, validated performance studies, environmental factors, and practical use. However, the impact of these considerations on sampler selection is minimized through generalized industry-specific or task-specific recommendations. An online web-based Sampler Selection Tool is under development. It will use the information presented in this Commentary to provide a ranked list of appropriate samplers to be used in specific situations.
- 9 June 2026
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 23 (10) , 828-880
Open AccessThe basis for recommending the selection of samplers in determining occupational exposures to aerosols
Measurements are considered to be the basis of exposure assessments used to determine risks to workers. Inhalation exposure poses the greatest risk for most airborne chemicals, and measurements are based on collecting (sampling) and analyzing air samples. Samplers have been developed for more than 120 years. Each new design has been intended to address flaws perceived in earlier designs. Users are faced with a varied array of samplers from which to choose. Comparisons are difficult to make because tests of sampler performance were not standardized until recently and have not been applied consistently. The existing large body of work does allow some conclusions to be drawn regarding performance. Many samplers have been shown to work effectively with test aerosols under controlled conditions in the laboratory. Further testing in the field has shown that not all samplers perform equally well in every situation; for example, under different wind speeds and directions or with aerosols that maintain unusual physical characteristics. There is not one aerosol sampler that can be used for all situations. Further, the design of a sampler and how the sampler needs to be handled can have an enormous influence on the result. Quality of manufacture, material of construction, cost, reusability, ease of use, setting of flow rates, transportation issues, and wearer acceptability all have an impact on selecting from among different samplers with similar performance. The range of available samplers constitutes a toolkit from which the most appropriate sampler could be selected for a given specific situation. Common inhalable and respirable aerosol samplers are considered in respect of their history of design and manufacture, validated performance studies, environmental factors, and practical use. However, the impact of these considerations on sampler selection is minimized through generalized industry-specific or task-specific recommendations. An online web-based Sampler Selection Tool is under development. It will use the information presented in this Commentary to provide a ranked list of appropriate samplers to be used in specific situations.
- Open Access
- 7 April 2025
- Published by Elsevier in Building and Environment
- Vol. 278
Understanding the effect of outdoor pollution episodes and HVAC type on indoor air quality
- 7 April 2025
- Published by Elsevier in Building and Environment
- Vol. 278
Open AccessUnderstanding the effect of outdoor pollution episodes and HVAC type on indoor air quality
- 29 December 2023
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 68 (2) , 192-202
Aerosol and surface contamination assessment of a novel ventilated infectious aerosol containment device
Healthcare personnels (HCPs) are at risk of respiratory infectious diseases during patient care activities. HCPs rely primarily on personal protective equipment to prevent pathogen exposures, but there is a need to develop alternative, or complementary control strategies, including engineering controls. The objective of this study was to evaluate the ability of the 3 designs (denoted D1A, D1B, and D2) of the University of Utah Containment Ventilation for Exposure Reduction (U-COVER), a protective barrier enclosure device to contain respirable aerosols when placed over a simulated patient. The 2 primary performance metrics were the percent reduction in: (i) the concentration of respirable aerosols in the simulated breathing zone of an HCP, and (ii) surface contamination outside the device, which were tested using salt aerosols and fluorescein aerosols, respectively. Briefly, salt or fluorescein aerosols were generated as though expelled by a prone patient under 3 conditions: (i) no device (control), (ii) with the device but without exhaust ventilation, and (iii) with the device with exhaust ventilation. Device D2 was also tested under simulated use conditions, in which cardboard “arms” were placed inside the device ports. All 3 device designs showed the ability to reduce particle concentrations in the simulated HCP breathing zone and on surfaces by >99% with exhaust ventilation compared to the control condition. Without exhaust ventilation, device performance was lower and highly variable. Under simulated use conditions, device D2 reduced particle concentrations in the simulated HCP breathing zone by ≥91% and on surfaces by >99% relative to control for all combinations of “arms” tested. The U-COVER device demonstrates excellent aerosol containment and warrants further testing with dynamic simulated or actual use conditions.
- 29 December 2023
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 68 (2) , 192-202
Aerosol and surface contamination assessment of a novel ventilated infectious aerosol containment device
Healthcare personnels (HCPs) are at risk of respiratory infectious diseases during patient care activities. HCPs rely primarily on personal protective equipment to prevent pathogen exposures, but there is a need to develop alternative, or complementary control strategies, including engineering controls. The objective of this study was to evaluate the ability of the 3 designs (denoted D1A, D1B, and D2) of the University of Utah Containment Ventilation for Exposure Reduction (U-COVER), a protective barrier enclosure device to contain respirable aerosols when placed over a simulated patient. The 2 primary performance metrics were the percent reduction in: (i) the concentration of respirable aerosols in the simulated breathing zone of an HCP, and (ii) surface contamination outside the device, which were tested using salt aerosols and fluorescein aerosols, respectively. Briefly, salt or fluorescein aerosols were generated as though expelled by a prone patient under 3 conditions: (i) no device (control), (ii) with the device but without exhaust ventilation, and (iii) with the device with exhaust ventilation. Device D2 was also tested under simulated use conditions, in which cardboard “arms” were placed inside the device ports. All 3 device designs showed the ability to reduce particle concentrations in the simulated HCP breathing zone and on surfaces by >99% with exhaust ventilation compared to the control condition. Without exhaust ventilation, device performance was lower and highly variable. Under simulated use conditions, device D2 reduced particle concentrations in the simulated HCP breathing zone by ≥91% and on surfaces by >99% relative to control for all combinations of “arms” tested. The U-COVER device demonstrates excellent aerosol containment and warrants further testing with dynamic simulated or actual use conditions.
- Open Access
A Comparison of Ambient Air Ethylene Oxide Modeling Estimates from Facility Stack and Fugitive Emissions to Canister-Based Ambient Air Measurements in Salt Lake City
Ethylene oxide (EtO) is a colorless, flammable gas at room temperature produced by the catalytic oxidation of ethylene. EtO is widely used by medical sterilization facilities to clean medical supplies and equipment. Recent epidemiological studies showed that EtO is a more potent carcinogen than previously documented, leading the Environmental Protection Agency (EPA) to update, in December 2016, the inhalation unit risk estimate for EtO. This resulted in the identification of EtO as a potential health concern in several areas across the US, including the state of Utah. The geography surrounding Salt Lake Valley creates a bowl, which is ideal for collecting air pollution emissions. The region often experiences inversion episodes which inhibit vertical mixing and cause an accumulation of air pollutants, leading to unhealthy pollution levels. Using the EPA’s dispersion modeling software, AERMOD, this study estimated EtO concentrations through facility stack and fugitive emissions modeling results. These values were compared with those of canister-based concentrations from ambient air samples taken near a medical device sterilization facility in Salt Lake Valley. Stainless steel whole-air passivated canisters were used to collect 24 h ambient concentration samples of EtO. Eight locations surrounding a Salt Lake Valley medical device sterilization facility and four background sites were chosen to measure the ambient concentrations. Accounting for potential atmospheric impacts on EtO, measurements were sampled in winter 2022 (January–March) and summer 2022 (July–September). The modeled EtO concentrations were adjusted to account for background values associated with the winter or summer data. Then, the two methodologies were compared using a Wilcoxon signed-ranked paired test. The statistical analysis resulted in six of the eight sample locations surrounding the sterilization facility being significantly different when comparing the canister-based measurements of ambient EtO to modeled estimates. Canister-based measurements taken at sites one, three, and four were statistically greater than the modeled estimates, while sites two, five, and seven were statistically less than the modeled estimates. Also, the summer background value calculated was almost 2.5 times greater than the winter one. The results do not suggest whether one method is more or less conservative than the other. In conclusion, the five of the closest sites and site seven were statistically different when comparing measured and modeled ambient concentrations of EtO. The comparison results do not clearly indicate if a correction factor could be derived for future human exposure to cancer risk assessment modeling. However, it is reasonable that the closer to the sterilization facility, the more total EtO exposure will be realized.
Open AccessA Comparison of Ambient Air Ethylene Oxide Modeling Estimates from Facility Stack and Fugitive Emissions to Canister-Based Ambient Air Measurements in Salt Lake City
Ethylene oxide (EtO) is a colorless, flammable gas at room temperature produced by the catalytic oxidation of ethylene. EtO is widely used by medical sterilization facilities to clean medical supplies and equipment. Recent epidemiological studies showed that EtO is a more potent carcinogen than previously documented, leading the Environmental Protection Agency (EPA) to update, in December 2016, the inhalation unit risk estimate for EtO. This resulted in the identification of EtO as a potential health concern in several areas across the US, including the state of Utah. The geography surrounding Salt Lake Valley creates a bowl, which is ideal for collecting air pollution emissions. The region often experiences inversion episodes which inhibit vertical mixing and cause an accumulation of air pollutants, leading to unhealthy pollution levels. Using the EPA’s dispersion modeling software, AERMOD, this study estimated EtO concentrations through facility stack and fugitive emissions modeling results. These values were compared with those of canister-based concentrations from ambient air samples taken near a medical device sterilization facility in Salt Lake Valley. Stainless steel whole-air passivated canisters were used to collect 24 h ambient concentration samples of EtO. Eight locations surrounding a Salt Lake Valley medical device sterilization facility and four background sites were chosen to measure the ambient concentrations. Accounting for potential atmospheric impacts on EtO, measurements were sampled in winter 2022 (January–March) and summer 2022 (July–September). The modeled EtO concentrations were adjusted to account for background values associated with the winter or summer data. Then, the two methodologies were compared using a Wilcoxon signed-ranked paired test. The statistical analysis resulted in six of the eight sample locations surrounding the sterilization facility being significantly different when comparing the canister-based measurements of ambient EtO to modeled estimates. Canister-based measurements taken at sites one, three, and four were statistically greater than the modeled estimates, while sites two, five, and seven were statistically less than the modeled estimates. Also, the summer background value calculated was almost 2.5 times greater than the winter one. The results do not suggest whether one method is more or less conservative than the other. In conclusion, the five of the closest sites and site seven were statistically different when comparing measured and modeled ambient concentrations of EtO. The comparison results do not clearly indicate if a correction factor could be derived for future human exposure to cancer risk assessment modeling. However, it is reasonable that the closer to the sterilization facility, the more total EtO exposure will be realized.
- Open Access
- 25 May 2023
- Published by MDPI AG in Preprints.org
A Comparison of Ambient Air Ethylene Oxide Modeling Estimates from Facility Stack and Fugitive Emissions to Canister-based Ambient Air Measurements in the Salt Lake City
Ethylene Oxide (EtO) is a colorless, flammable gas at room temperature, produced by the catalytic oxidation of ethylene. EtO is widely used by medical sterilization facilities to clean medical supplies and equipment. Recent epidemiological studies showed that EtO is a more potent carcinogen than previously documented, leading the Environmental Protection Agency (EPA) to update, in December 2016, the inhalation unit risk estimate for EtO. This resulted in the identification of EtO as a potential health concern in several areas across the US, including the state of Utah. The geography surrounding Salt Lake Valley creates a bowl; ideal for collecting air pollution emissions. The region often experiences inversion episodes which inhibit vertical mixing and cause an accumulation of air pollutants, leading to unhealthy pollution levels. Using the EPA's dispersion modeling software, AERMOD, this study estimated EtO concentrations through facility stack and fugitive emissions modeling results. These values were compared with those of canister-based concentrations from ambient air samples taken near a medical device sterilization facility in the Salt Lake Valley. Stainless steel, whole-air passivated canisters were used to collect 24-hour ambient concentration samples of EtO. Eight locations surrounding a Salt Lake Valley medical device sterilization facility and four background sites were chosen to measure the ambient concentrations. Accounting for potential atmospheric impacts on EtO, measurements were sampled in winter 2022 (January-March) and summer 2022 (July-September). The modeled EtO concentrations were adjusted to account for background values associated with the winter or summer data. Then the two methodologies were compared using a Wilcoxon Sign-ranked, paired test. The statistical analysis resulted in six of the eight sample locations surrounding the sterilization facility being significantly different when comparing canister-based measurements of ambient EtO to modeled estimates. Canister-based measurements taken at sites one, three, and four were statistically greater than the modeled estimates, while sites two, five, and seven were statistically less than the modeled estimates. Also, the summer background value calculated was almost 2.5 times greater than the winter. The results do not suggest whether one method is more or less conservative than the other. In conclusion, the five of the closest sites and site seven were statistically different when comparing measured and modeled ambient concentrations of EtO. The comparison results do not clearly indicate if a correction factor could be derived for future human exposure to cancer risk assessment modeling. However, it is reasonable that the closer to the sterilization facility, the more total EtO exposure will be realized.
- 25 May 2023
- Published by MDPI AG in Preprints.org
Open AccessA Comparison of Ambient Air Ethylene Oxide Modeling Estimates from Facility Stack and Fugitive Emissions to Canister-based Ambient Air Measurements in the Salt Lake City
Ethylene Oxide (EtO) is a colorless, flammable gas at room temperature, produced by the catalytic oxidation of ethylene. EtO is widely used by medical sterilization facilities to clean medical supplies and equipment. Recent epidemiological studies showed that EtO is a more potent carcinogen than previously documented, leading the Environmental Protection Agency (EPA) to update, in December 2016, the inhalation unit risk estimate for EtO. This resulted in the identification of EtO as a potential health concern in several areas across the US, including the state of Utah. The geography surrounding Salt Lake Valley creates a bowl; ideal for collecting air pollution emissions. The region often experiences inversion episodes which inhibit vertical mixing and cause an accumulation of air pollutants, leading to unhealthy pollution levels. Using the EPA's dispersion modeling software, AERMOD, this study estimated EtO concentrations through facility stack and fugitive emissions modeling results. These values were compared with those of canister-based concentrations from ambient air samples taken near a medical device sterilization facility in the Salt Lake Valley. Stainless steel, whole-air passivated canisters were used to collect 24-hour ambient concentration samples of EtO. Eight locations surrounding a Salt Lake Valley medical device sterilization facility and four background sites were chosen to measure the ambient concentrations. Accounting for potential atmospheric impacts on EtO, measurements were sampled in winter 2022 (January-March) and summer 2022 (July-September). The modeled EtO concentrations were adjusted to account for background values associated with the winter or summer data. Then the two methodologies were compared using a Wilcoxon Sign-ranked, paired test. The statistical analysis resulted in six of the eight sample locations surrounding the sterilization facility being significantly different when comparing canister-based measurements of ambient EtO to modeled estimates. Canister-based measurements taken at sites one, three, and four were statistically greater than the modeled estimates, while sites two, five, and seven were statistically less than the modeled estimates. Also, the summer background value calculated was almost 2.5 times greater than the winter. The results do not suggest whether one method is more or less conservative than the other. In conclusion, the five of the closest sites and site seven were statistically different when comparing measured and modeled ambient concentrations of EtO. The comparison results do not clearly indicate if a correction factor could be derived for future human exposure to cancer risk assessment modeling. However, it is reasonable that the closer to the sterilization facility, the more total EtO exposure will be realized.
- Open Access
Aerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation
Increasing concern over air pollution has led to the development of low-cost sensors suitable for wide-scale deployment and use by citizen scientists. This project investigated the AirU low-cost particle sensor using two methods: (1) a comparison of pre- and post-deployment calibration equations for 24 devices following use in a field study, and (2) an in-home comparison between 3 AirUs and a reference instrument, the GRIMM 1.109. While differences (and therefore some sensor degradation) were found in the pre- and post-calibration equation comparison, absolute value changes were small and unlikely to affect the quality of results. Comparison tests found that while the AirU did tend to underestimate minimum and overestimate maximum concentrations of particulate matter, ~88% of results fell within ±1 μg/m3 of the GRIMM. While these tests confirm that low-cost sensors such as the AirU do experience some sensor degradation over multiple months of use, they remain a valuable tool for exposure assessment studies. Further work is needed to examine AirU performance in different environments for a comprehensive survey of capability, as well as to determine the source of sensor degradation.
Open AccessAerosol Measurement Degradation in Low-Cost Particle Sensors Using Laboratory Calibration and Field Validation
Increasing concern over air pollution has led to the development of low-cost sensors suitable for wide-scale deployment and use by citizen scientists. This project investigated the AirU low-cost particle sensor using two methods: (1) a comparison of pre- and post-deployment calibration equations for 24 devices following use in a field study, and (2) an in-home comparison between 3 AirUs and a reference instrument, the GRIMM 1.109. While differences (and therefore some sensor degradation) were found in the pre- and post-calibration equation comparison, absolute value changes were small and unlikely to affect the quality of results. Comparison tests found that while the AirU did tend to underestimate minimum and overestimate maximum concentrations of particulate matter, ~88% of results fell within ±1 μg/m3 of the GRIMM. While these tests confirm that low-cost sensors such as the AirU do experience some sensor degradation over multiple months of use, they remain a valuable tool for exposure assessment studies. Further work is needed to examine AirU performance in different environments for a comprehensive survey of capability, as well as to determine the source of sensor degradation.
- Open Access
- 5 April 2022
- Published by Annual Reviews in Annual Review of Public Health
- Vol. 43 (1) , 311-330
Transmission of Respiratory Viral Diseases to Health Care Workers: COVID-19 as an Example
Health care workers (HCWs) can acquire infectious diseases, including coronavirus disease 2019 (COVID-19), from patients. Herein, COVID-19 is used with the source–pathway–receptor framework as an example to assess evidence for the roles of aerosol transmission and indirect contact transmission in viral respiratory infectious diseases. Evidence for both routes is strong for COVID-19 and other respiratory viruses, but aerosol transmission is likely dominant for COVID-19. Key knowledge gaps about transmission processes and control strategies include the distribution of viable virus among respiratory aerosols of different sizes, the mechanisms and efficiency by which virus deposited on the facial mucous membrane moves to infection sites inside the body, and the performance of source controls such as face coverings and aerosol containment devices. To ensure that HCWs are adequately protected from infection, guidelines and regulations must be updated to reflect the evidence that respiratory viruses are transmitted via aerosols.
- 5 April 2022
- Published by Annual Reviews in Annual Review of Public Health
- Vol. 43 (1) , 311-330
Open AccessTransmission of Respiratory Viral Diseases to Health Care Workers: COVID-19 as an Example
Health care workers (HCWs) can acquire infectious diseases, including coronavirus disease 2019 (COVID-19), from patients. Herein, COVID-19 is used with the source–pathway–receptor framework as an example to assess evidence for the roles of aerosol transmission and indirect contact transmission in viral respiratory infectious diseases. Evidence for both routes is strong for COVID-19 and other respiratory viruses, but aerosol transmission is likely dominant for COVID-19. Key knowledge gaps about transmission processes and control strategies include the distribution of viable virus among respiratory aerosols of different sizes, the mechanisms and efficiency by which virus deposited on the facial mucous membrane moves to infection sites inside the body, and the performance of source controls such as face coverings and aerosol containment devices. To ensure that HCWs are adequately protected from infection, guidelines and regulations must be updated to reflect the evidence that respiratory viruses are transmitted via aerosols.