TXTingfei Xi

Tingfei Xi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tingfei Xi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Regulation challenge of tissue engineering and regenerative medicine in China

    by Tingfei Xi, Liang Chen, Chunren Wang

    The current regulatory status in the USA, European Union (EU), Japan, and China, associated with the clinical application of tissue engineering and re


  • Concentration-dependent cytotoxicity of copper ions on mouse fibroblasts in vitro: effects of copper ion release from TCu380A vs TCu220C intra-uterine devices

    by Bianmei Cao, Yudong Zheng, Tingfei Xi, Chuanchuan Zhang, Wenhui Song, Krishna Burugapalli, Huai Yang, Yanxuan Ma

    Sustained release of copper (Cu) ions from Cu-containing intrauterine devices (CuIUD) is quite efficient for contraception. However, the tissue surrounding the CuIUD is exposed to toxic Cu ion levels. The objective for this study was to quantify the concentration dependent cytotoxic effects of Cu ions and correlate the toxicity due to Cu ion burst release for two popular T-shaped IUDs - TCu380A and TCu220C on L929 mouse fibroblasts. Fibroblasts were cultured in 98 well tissue culture plates and 3-(4,5-dimethylthiazol- 2-yl)-2,5-diphehyltetrazolium bromide (MTT) assay was used to determine their viability and proliferation as a function of time. For cell seeding numbers ranging from 10,000 to 100,000, a maximum culture time of 48 h was identified for fibroblasts without significant reduction in cell proliferation due to contact inhibition. Thus, for Cu cytotoxicity assays, a cell seeding density of 50,000 and a maximum culture time of 48 h in 96 well plates were used. 24 h after cell seeding, culture media were replaced with Cu ion containing media solutions of different concentrations, including 24 and 72 h extracts from TCuIUDs and incubated for a further 24 h. Cell viability decreased with increasing Cu ion concentration, with 30 % and 100 % reduction for 40 μg/ml and 100 μg/ml respectively at 24 h. The cytotoxic effects were further evaluated using light microscopy, apoptosis and cell cycle analysis assays. Fibroblasts became rounded and eventually detached from TCP surface due to Cu ion toxicity. A linear increase in apoptotic cell population with increasing Cu ion concentration was observed in the tested range of 0 to 50 μg/ml. Cell cycle analysis indicated the arrest of cell division for the tested 25 to 50 μg/ml Cu ion treatments. Among the TCuIUDs, TCu220C having 265 mm2 Cu surface area released 9.08 ± 0.16 and 26.02 ± 0.25 μg/ml, while TCu380A having 400 mm2 released 96.7 ± 0.11 and 159.3 ± 0.15 μg/ml respectively following 24 and 72 h extractions. The effects of TCuIUD extracts on viability, morphology, apoptosis and cell cycle assay on L929 mouse fibroblasts cells, were appropriate for their respective Cu ion concentrations. Thus, a concentration of about 46 μg/ml (~29 μM) was identified as the LD50 dose for L929 mouse fibroblasts when exposed for 24 h based on our MTT cell viability assay. The burst release of lethal concentration of Cu ions from TCu380A, especially at the implant site, is a cause of concern, and it is advisable to use TCuIUD designs that release Cu ions within cytotoxic limits yet therapeutic, similar to TCu220C.


    • 1 February 2011
      • Vol. 25  (2) , 129-32

    [Experimental study on constructing a tissue engineered epidermis for replacement of skin irritation in vitro].

    by Zhongliang Li, Jinjin Wu, Guihong Yang, Tingfei Xi, Chunren Wang, Liang Chen

    To investigate the method of constructing a tissue engineered epidermis with human epidermal cells and polycarbonate membrane, and to establish a tissue engineered epidermis with barrier function which is intended to be the replacing model in vitro of skin irritation test. The tissue engineered epidermis was constructed by using polycarbonate membrane as scaffold and stratified differentiated epidermis derived from human keratinocytes. The tissue engineered epidermis was cultured on an inert polycarbonate filter at the air-liquid interface. After 13 days of culture, the composition and structure of tissue engineered epidermis were observed by HE staining, immunofluorescence staining of keratin 10 (K10) & K13, K14, laminin, involucrin, and filaggrin, and transmission electronic microscope. The half maximal inhibitory concentration of a substance (IC50) of SDS was determined in the penetration test of tissue engineered epidermis cultured in the absence (control group) or the presence (experimental group) of lipid supplement for 18 hours. The constructed epidermis was similar to normal epidermis, which was consisted of a proliferating basal layer, differentiated spinous layer, granular layer, and stratum corneum. The IC50 values of tissue engineered epidermis cultured in the control group and experimental group were 0.072% (2.36 mmol/L) and 0.183% (6.00 mmol/L), respectively. The tissue engineered epidermis constructed on polycarbonate membrane has normal composition and structure and barrier function corresponding to the normal epidermis.

  • In vitro and in vivo changes to PLGA/sirolimus coating on drug eluting stents

    by Tingfei Xi, Runlin Gao, Bo Xu, Liang Chen, Tong Luo, Jing Liu, Yan Wei, Shengping Zhong


    • 1 October 2009
      • Vol. 26  (5) , 1162-6

    [Study and evaluation on hemocompatibility of biomaterials].

    by Lifeng Yang, Jianxia Xu, Tingfei Xi

    Hemocompatibility is an important component of biocompatibility; it reflects the degree of interaction between material and blood. Hemocompatibility is multifaceted, so that the material's impact on the blood and the underlying mechanism are very complicated. This article presents a review of researches probing the impact of material on blood via contact activation and plasma protein adsorption; via the platelet activated and the formation of thrombin; via the complement system activated and the activation of leukocytes as well as other mechanisms of hemolysis. The current methods for evaluation and the future trend of development are also introduced.


    • 1 February 2008
      • Vol. 25  (1) , 117-21

    [Effect of steam sterilization on poly(ether-ester)s copolymer and its vascular cell compatibility].

    by Wei Wang, Tingfei Xi, Liang Chen, Aiying Zhang, Liancai Wang

    The aim of this research was to evaluate the influence of steam sterilization on poly(ethylene glycol-terephthalate) and poly(butylene terephthalate) copolymer (PEGT/PBT) and its vascular cells compatibility, which was used as the scaffolds in vascular tissue engineering. Endothelial cells, smooth muscle cells and fibroblasts were cultured separately on the films after steam sterilization and after ultraviolet sterilization. These cells can grow well on the films after ultraviolet sterilization, while they can hardly adhere on steam sterilized films. Differential scanning calorimetry, static contact angle, X-ray photoelectron spectroscopy, surface carboxyl density quantity, H-nuclear magnetic resonance and scanning electronic microscope were employed to characterize the properties of poly(ether-esters) films before and after sterilization. These results showed that steam sterilization had little effect on the surface morphology and on the constitution of the copolymer, but the copolymer segments were redistributed during steam sterilization. The hydrophilic poly(ethylene glycol) (PEG) and the end carboxyl groups transferred from the bulk and enriched on the surface and the degree of crystallinity of hard segments increased slightly. Both the end carboxyl and PEG enriched on the surface can hinder the protein adhesion on the surface; so, lacking in receptor, the vascular cells cannot adhere on the films surfaces.

    • 1 November 2003
      • Vol. 17  (6) , 480-7

    [Supervision, administration and standard research related to tissue engineered medical products].

    by Ting-Fei Xi, Liang Chen, Peng Zhao

    Tissue engineering advance in supplying the reparative and reconstructive medicine with promising tissue engineered medical products(TEMPs) and the new therapy alternative. The related supervision and administration of TEMPs is being developed and the standard research of TEMPs is also in progress. The Food and Drug Administration(FDA) of the United States has treated TEMPs as combined products and supervised them according to the level of risk to patients. Lately, FDA has determined that the Center for Devices and Radiological Health (CDRH) should take charge of examination and approval of TEMPs, with the cooperation of the Center for Biological Evaluations and Research(CBER). The regulatory controls have been established respectively in European Union and Japan. In China, TEMPs are identified as medical devices combined with cells. The Department of Medical Device of the State Food and Drug Administration (SFDA) is responsible for the examination and approval of TEMPs, and National Institute for the Control of Pharmaceutical & Biological Products(NICPBP) is responsible for evaluation tests. The standards of TEMPs are formulated mainly by the American Society of Testing Materials(ASTM) and International Standardization Organization(ISO).