Babu Kunadian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Babu Kunadian has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Mark A. de Belder
National Institute for Cardiovascular Outcomes Research (NICOR), Barts Health NHS Trust, London, UK
3 shared publications - James Anthony Hall
Indiana University School of Medicine & Indiana University School of Social Work
2 shared publications Kunadian Vijayalakshmi
Department of Cardiology, The James Cook University Hospital, Middlesbrough, United Kingdom
2 shared publicationsAndrew G.C. Sutton
Department of Cardiology, The James Cook University Hospital, Middlesbrough, United Kingdom
1 shared publicationAndrew R Thornley
1 shared publicationAndrew Sutton
1 shared publication
Latest Publications
- 23 March 2009
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 73 (5) , 589-594
Funnel plots for comparing performance of PCI performing hospitals and cardiologists: Demonstration of utility using the New York hospital mortality data
Background: The New York State Department of Health collects and reports outcome data on the hospitals and cardiologists who perform percutaneous coronary intervention (PCI) to allow them to examine their quality of care. Results are provided in tabular form. However funnel plots are the display method of choice for comparison of institutions and operators, using the principles of statistical process control (SPC). We aimed to demonstrate that funnel plots, which aid a meaningful interpretation of the results, can be derived from the New York PCI dataset. Methods: The risk‐adjusted mortality rates for 48 hospitals and cardiologists performing PCI were used for this analysis. Funnel plots (with control limits at 3 and 2 σ) of all hospitals and operators performing PCI procedures were generated. Separate plots for emergency and nonemergency PCI procedures were derived. Results: 149,888 patients underwent PCI procedures between January 1, 2002 and December 31, 2004. The 3‐year risk‐adjusted mortality rates for all PCI patients ranged from 0.00 to 1.37%. The funnel plots show risk‐adjusted mortality rates against the denominator for that percentage (number of cases), displayed as a scatter plot and compared with the binomial funnel plot calculated around the mean for all cases reported. The risk‐adjusted mortality rates of all hospitals were within 3 σ (99.8%) upper control limits. The risk‐adjusted mortality rates for three hospitals were above or on the upper warning limit (2 σ control limit, equating to the 95% confidence interval) and three hospitals had risk‐adjusted mortality rates below the 2 and 3 σ control limits. Conclusion: The SPC funnel plot is an easy‐to‐interpret, risk‐adjusted means of identifying units whose performance, in terms of mortality, diverges significantly from the population mean. Funnel plots may be applied to a complex dataset and allow a visual comparison of data derived from multiple healthcare units. Variation is readily identified permitting hospitals and cardiologists to appraise their practices so that effective quality improvement may take place.
- 23 March 2009
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 73 (5) , 589-594
Funnel plots for comparing performance of PCI performing hospitals and cardiologists: Demonstration of utility using the New York hospital mortality data
Background: The New York State Department of Health collects and reports outcome data on the hospitals and cardiologists who perform percutaneous coronary intervention (PCI) to allow them to examine their quality of care. Results are provided in tabular form. However funnel plots are the display method of choice for comparison of institutions and operators, using the principles of statistical process control (SPC). We aimed to demonstrate that funnel plots, which aid a meaningful interpretation of the results, can be derived from the New York PCI dataset. Methods: The risk‐adjusted mortality rates for 48 hospitals and cardiologists performing PCI were used for this analysis. Funnel plots (with control limits at 3 and 2 σ) of all hospitals and operators performing PCI procedures were generated. Separate plots for emergency and nonemergency PCI procedures were derived. Results: 149,888 patients underwent PCI procedures between January 1, 2002 and December 31, 2004. The 3‐year risk‐adjusted mortality rates for all PCI patients ranged from 0.00 to 1.37%. The funnel plots show risk‐adjusted mortality rates against the denominator for that percentage (number of cases), displayed as a scatter plot and compared with the binomial funnel plot calculated around the mean for all cases reported. The risk‐adjusted mortality rates of all hospitals were within 3 σ (99.8%) upper control limits. The risk‐adjusted mortality rates for three hospitals were above or on the upper warning limit (2 σ control limit, equating to the 95% confidence interval) and three hospitals had risk‐adjusted mortality rates below the 2 and 3 σ control limits. Conclusion: The SPC funnel plot is an easy‐to‐interpret, risk‐adjusted means of identifying units whose performance, in terms of mortality, diverges significantly from the population mean. Funnel plots may be applied to a complex dataset and allow a visual comparison of data derived from multiple healthcare units. Variation is readily identified permitting hospitals and cardiologists to appraise their practices so that effective quality improvement may take place.
- 1 August 2007
- Vol. 19 (8) , 339-46
Intra-aortic counterpulsation does not improve coronary flow early after PCI in a high-risk group of patients: observations from a randomized trial to explore its mode of action.
The intra-aortic balloon pump (IABP) is the most commonly used temporary cardiac assist device. The precise role and the mechanism of any benefit in high-risk patients undergoing percutaneous coronary intervention (PCI) have not been fully determined. We hypothesized that the use of an IABP following PCI in high-risk non-shocked patients would immediately increase coronary blood flow, tissue perfusion and hence preserve left ventricular function. Predefined high-risk, but non-shocked, patients were randomized to either an IABP or no IABP following PCI. Angiography was performed pre-PCI, immediately post-PCI and 10 minutes after the completion of the procedure. TIMI flow grade (TFG), TIMI frame count (TFC) and myocardial blush grade (MBG) were measured. Echocardiographic wall motion index (WMI) was measured on days 1 and 30 following PCI. Of 33 patients, 17 received IABP and 16 did not. At final angiography, the TFG was 2.8 +/- 0.7 and 2.9 +/- 0.3 (p = 0.6), the TFC was 19.9 +/- 23 and 16.9 +/- 16.9 (p = 0.7), and the MBG was 2.5 +/- 0.9 and 2.5 +/- 0.7 (p = 0.9) in the IABP and the no-IABP arms. The WMI on day 1 was 1.7 +/- 0.4 and 1.7 +/- 0.4 (p = 0.7), and on day 30, it was 1.5 +/- 0.4 and 1.5 +/- 0.4 (p = 0.9). There was no difference in the total sum of ST-segment elevation prior to PCI (12.6 +/- 7.7 vs. 13.5 +/- 7.9; p = 0.8), nor in the summed ST change in subsequent electrocardiograms (ECGs) to 48 hours in both of the groups. Whether an IABP is of any benefit in non-shocked, but high-risk, patients undergoing PCI remains to be established, but any potential benefit does not appear to be associated with early improvement in coronary flow. Whether the insertion of an IABP improves coronary flow beyond 10 minutes is not known. However, the IABP did not significantly affect subsequent left ventricular wall motion index or ECG ST-segment resolution in this study.
- 1 August 2007
- Vol. 19 (8) , 339-46
Intra-aortic counterpulsation does not improve coronary flow early after PCI in a high-risk group of patients: observations from a randomized trial to explore its mode of action.
The intra-aortic balloon pump (IABP) is the most commonly used temporary cardiac assist device. The precise role and the mechanism of any benefit in high-risk patients undergoing percutaneous coronary intervention (PCI) have not been fully determined. We hypothesized that the use of an IABP following PCI in high-risk non-shocked patients would immediately increase coronary blood flow, tissue perfusion and hence preserve left ventricular function. Predefined high-risk, but non-shocked, patients were randomized to either an IABP or no IABP following PCI. Angiography was performed pre-PCI, immediately post-PCI and 10 minutes after the completion of the procedure. TIMI flow grade (TFG), TIMI frame count (TFC) and myocardial blush grade (MBG) were measured. Echocardiographic wall motion index (WMI) was measured on days 1 and 30 following PCI. Of 33 patients, 17 received IABP and 16 did not. At final angiography, the TFG was 2.8 +/- 0.7 and 2.9 +/- 0.3 (p = 0.6), the TFC was 19.9 +/- 23 and 16.9 +/- 16.9 (p = 0.7), and the MBG was 2.5 +/- 0.9 and 2.5 +/- 0.7 (p = 0.9) in the IABP and the no-IABP arms. The WMI on day 1 was 1.7 +/- 0.4 and 1.7 +/- 0.4 (p = 0.7), and on day 30, it was 1.5 +/- 0.4 and 1.5 +/- 0.4 (p = 0.9). There was no difference in the total sum of ST-segment elevation prior to PCI (12.6 +/- 7.7 vs. 13.5 +/- 7.9; p = 0.8), nor in the summed ST change in subsequent electrocardiograms (ECGs) to 48 hours in both of the groups. Whether an IABP is of any benefit in non-shocked, but high-risk, patients undergoing PCI remains to be established, but any potential benefit does not appear to be associated with early improvement in coronary flow. Whether the insertion of an IABP improves coronary flow beyond 10 minutes is not known. However, the IABP did not significantly affect subsequent left ventricular wall motion index or ECG ST-segment resolution in this study.
- 1 December 2006
- Vol. 18 (12) , E302-4
Percutaneous treatment of a large coronary aneurysm with a ball thrombus: an interventional challenge.
- 1 December 2006
- Vol. 18 (12) , E302-4
Percutaneous treatment of a large coronary aneurysm with a ball thrombus: an interventional challenge.
- 1 June 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 67 (6) , 879-886
Successful thrombus extraction with the Rescue™ thrombus management system during acute percutaneous coronary intervention improves flow but does not necessarily restore optimal myocardial tissue perfusion
We determined the effectiveness of the Rescue™ device in restoring flow and achieving optimal tissue perfusion during percutaneous coronary intervention (PCI) in thrombus‐laden coronary arteries. Methods: A total of 30 patients with an acute coronary syndrome underwent PCI using the Rescue device. Results: The mean age was 65.5 ± 9.8 years. Although the Rescue device could not be passed across the lesion in 6 (20%) cases, debris was aspirated in 26 (87%). The uncorrected TIMI frame count improved following the use of the Rescue device and improved further at the completion of PCI (92.2 ± 23.9 pre‐PCI vs. 38.7 ± 31.3 post‐Rescue vs. 21.96 ± 24 post‐PCI, P < 0.0001). The thrombus score improved from 4 ± 0 to 2.2 ± 1.29 to 0.86 ± 1.4 (P < 0.0001). TIMI flow grade (TFG) 3 was restored in 60% of cases following the Rescue device and in 87% after PCI. Myocardial blush grade 3 occurred in only 13% of patients following the Rescue device and 37% of patients after PCI. Conclusion: These data suggest that the Rescue device can aspirate considerable amounts of debris in the majority of patients and significantly improves the angiographic epicardial coronary blood flow. How effective such a device is in improving tissue perfusion and, thereby, clinical outcomes for patients remains to be seen. © 2006 Wiley‐Liss Inc.
- 1 June 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 67 (6) , 879-886
Successful thrombus extraction with the Rescue™ thrombus management system during acute percutaneous coronary intervention improves flow but does not necessarily restore optimal myocardial tissue perfusion
We determined the effectiveness of the Rescue™ device in restoring flow and achieving optimal tissue perfusion during percutaneous coronary intervention (PCI) in thrombus‐laden coronary arteries. Methods: A total of 30 patients with an acute coronary syndrome underwent PCI using the Rescue device. Results: The mean age was 65.5 ± 9.8 years. Although the Rescue device could not be passed across the lesion in 6 (20%) cases, debris was aspirated in 26 (87%). The uncorrected TIMI frame count improved following the use of the Rescue device and improved further at the completion of PCI (92.2 ± 23.9 pre‐PCI vs. 38.7 ± 31.3 post‐Rescue vs. 21.96 ± 24 post‐PCI, P < 0.0001). The thrombus score improved from 4 ± 0 to 2.2 ± 1.29 to 0.86 ± 1.4 (P < 0.0001). TIMI flow grade (TFG) 3 was restored in 60% of cases following the Rescue device and in 87% after PCI. Myocardial blush grade 3 occurred in only 13% of patients following the Rescue device and 37% of patients after PCI. Conclusion: These data suggest that the Rescue device can aspirate considerable amounts of debris in the majority of patients and significantly improves the angiographic epicardial coronary blood flow. How effective such a device is in improving tissue perfusion and, thereby, clinical outcomes for patients remains to be seen. © 2006 Wiley‐Liss Inc.