B. Clasbrummel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
B. Clasbrummel has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
G. Muhr
Hospital „Bergmannsheil”, University of Bochum, Bochum, Germany
6 shared publicationsG Muhr
3 shared publicationsA. Dávid
2 shared publicationsM. Hahn
2 shared publicationsM. Raschke
2 shared publicationsA Dàvid
1 shared publication
Latest Publications
- 1 January 2004
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 13 (2) , 105-109
Pressure sensors for the monitoring of diseases in surgical care
Microtechnology components are already pointing the way forwards in minimally invasive diagnosis, therapy and therapy monitoring, in implants and medication dosage systems. The latest developments show a wide range of new possible uses for microtechnology in medical applications. The world market in physical pressure, temperature and acceleration sensors was worth several hundred billion euros in 2003. Given the extreme miniaturisation now possible through micro- and nanotechnology, such sensors readily suggest themselves for medical applications. If physical sensors are linked to a telemetric unit for wireless data transmission, are biocompatibly packaged or are implanted in a minimally invasive procedure, then bodily functions such as the acceleration of vessel walls, blood pressure, temperature or nerve streams can be measured permanently and wirelessly. Regarding pressure sensors, surgical diagnosis is yielding a range of possibilities extending from pressure measurements in the brain following a trauma, compartment pressure measurements in the abdomen, organs or extremities through to bladder pressure measurements for injury patients with compartment syndrome. The present work gives a surgery-based overview of the latest developments and trends in this high technology field.
- 1 January 2004
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 13 (2) , 105-109
Pressure sensors for the monitoring of diseases in surgical care
Microtechnology components are already pointing the way forwards in minimally invasive diagnosis, therapy and therapy monitoring, in implants and medication dosage systems. The latest developments show a wide range of new possible uses for microtechnology in medical applications. The world market in physical pressure, temperature and acceleration sensors was worth several hundred billion euros in 2003. Given the extreme miniaturisation now possible through micro- and nanotechnology, such sensors readily suggest themselves for medical applications. If physical sensors are linked to a telemetric unit for wireless data transmission, are biocompatibly packaged or are implanted in a minimally invasive procedure, then bodily functions such as the acceleration of vessel walls, blood pressure, temperature or nerve streams can be measured permanently and wirelessly. Regarding pressure sensors, surgical diagnosis is yielding a range of possibilities extending from pressure measurements in the brain following a trauma, compartment pressure measurements in the abdomen, organs or extremities through to bladder pressure measurements for injury patients with compartment syndrome. The present work gives a surgery-based overview of the latest developments and trends in this high technology field.
- 1 January 2002
- p. 641-3
[Error assessment of color management in digital images in telemedicine].
- 1 January 2001
- Published by Springer Nature
- p. 20-33
Experimentelle Unfallchirurgie
- 1 January 1997
- p. 521-2
[Time-dependent mechanical stimulation of enchondral fracture healing in the sheep].
- 1 January 1997
- p. 521-2
[Time-dependent mechanical stimulation of enchondral fracture healing in the sheep].
- 1 January 1997
- Published by Springer Nature
- p. 1094-1095
Abhängigkeit von Fragmentdislokationen vom Nageldesign bei proximalen und distalen Tibiafragmenten nach ungebohrter Marknagelung
- 1 January 1997
- Published by Springer Nature
- p. 1094-1095
Abhängigkeit von Fragmentdislokationen vom Nageldesign bei proximalen und distalen Tibiafragmenten nach ungebohrter Marknagelung
- 1 January 1997
- Published by Springer Nature
- p. 520-521
Der Kniegelenksinfekt: Eine Analyse von 80 infizierten Kniegelenken
- 1 January 1997
- Published by Springer Nature
- p. 520-521
Der Kniegelenksinfekt: Eine Analyse von 80 infizierten Kniegelenken
- 1 January 1994
- Vol. 119 (8) , 538-44
[Sports fitness after functional conservative versus surgical treatment of acute Achilles tendon ruptures].
Acute Achilles tendon ruptures are mostly related to recreational activities. Therefore, these patients intend to return to sports as soon as possible with no functional deficiency. This is the first study, comparing functional results after functional treatment to those after surgery. According to sonographic examinations of the tendon gap, primary functional treatment with heel supported shoes or surgery were suggested. Between 2/1991 and 12/1992, 22 patients with acute Achilles tendon rupture were treated without operation (group 1) and in 10 patient the rupture was sutured (group 2). 6 months later, 27 patients underwent standardized clinical examination: one leg standing for one minute, measurement of the circumference of the calf. The actual activities were assigned to Tegner Activity Score. 19 patients had isokinetic cybex testing with 60 degrees/s. There were 3 re-ruptures in group 1 and no comparable complications in group 2. At this time, clinical examination and Tegner Activity Score showed no relevant differences. Force of flexion was 30.4% lowered in group 1 and 2.4% in group 2. Additional training of the calf muscles improved the results after 6 weeks in group 1. We concluded that individual management of acute Achilles tendon rupture is possible according to sonographic tendon gap. Functional treatment is effective, but the rate of re-ruptures has to be reduced by careful selection of patients (rupture gap < or = 2 mm, high cooperation).
- 1 January 1994
- Vol. 119 (8) , 538-44
[Sports fitness after functional conservative versus surgical treatment of acute Achilles tendon ruptures].
Acute Achilles tendon ruptures are mostly related to recreational activities. Therefore, these patients intend to return to sports as soon as possible with no functional deficiency. This is the first study, comparing functional results after functional treatment to those after surgery. According to sonographic examinations of the tendon gap, primary functional treatment with heel supported shoes or surgery were suggested. Between 2/1991 and 12/1992, 22 patients with acute Achilles tendon rupture were treated without operation (group 1) and in 10 patient the rupture was sutured (group 2). 6 months later, 27 patients underwent standardized clinical examination: one leg standing for one minute, measurement of the circumference of the calf. The actual activities were assigned to Tegner Activity Score. 19 patients had isokinetic cybex testing with 60 degrees/s. There were 3 re-ruptures in group 1 and no comparable complications in group 2. At this time, clinical examination and Tegner Activity Score showed no relevant differences. Force of flexion was 30.4% lowered in group 1 and 2.4% in group 2. Additional training of the calf muscles improved the results after 6 weeks in group 1. We concluded that individual management of acute Achilles tendon rupture is possible according to sonographic tendon gap. Functional treatment is effective, but the rate of re-ruptures has to be reduced by careful selection of patients (rupture gap < or = 2 mm, high cooperation).
- 1 January 1994
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 39 (s1) , 145-146
Abhängigkeit von Fragmentdislokationen vom Nageldesign bei proximalen und distalen Tibiafragmenten nach ungebohrter Marknagelung
- 1 January 1994
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 39 (s1) , 145-146
Abhängigkeit von Fragmentdislokationen vom Nageldesign bei proximalen und distalen Tibiafragmenten nach ungebohrter Marknagelung