Marco Rainer Kesting
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Marco Rainer Kesting has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Lars Steinstraesser
Klinikum Bergmannsheil, Ruhr University Bochum
2 shared publications- Thomas Mücke
Department of Oral and Maxillofacial Surgery, Malteser Kliniken Rhein-Ruhr, Krefeld-Uerdingen, Germany
2 shared publications Cedric Demtroeder
Department of Oral and Maxillofacial Surgery, Klinikum Rechts der Isar der Technischen Universität München, 81675 München, Germany
1 shared publicationCraig Wales
Southern General Hospital
1 shared publicationDenys John Loeffelbein
Burn Unit, Department of Plastic Surgery, BG-Universitätsklinikum ‘‘Bergmannsheil,’’ Ruhr-Universität Bochum, 44789 Bochum, Germany
1 shared publicationFrank Hölzle
Technische Universität München
1 shared publication
Latest Publications
- 11 February 2011
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 18 (7) , 1988-1994
Microsurgical Reconstruction of the Oral Cavity with Free Flaps from the Anterolateral Thigh and the Radial Forearm: A Comparison of Perioperative Data from 161 Cases
Free flaps are commonly used for reconstruction of extensive tumor resection defects in the oral cavity. The radial forearm free flap (RFFF) is the most frequent choice. However, a major problem of RFFF is a limitation in its size. The anterolateral thigh free flap (ALTFF) has become popular as an alternative donor site in maxillofacial surgery. We have compared patient data after reconstructions of the oral cavity using the RFFF or ALTFF. Perioperative data of 161 oral cancer patients with ALTFF (45) or RFFF (116) reconstructions were reviewed and statistically analyzed for the following characteristics: sex, histology, primary tumor localization, defect type, American Society of Anesthesiology score, success rates, revisions, wound healing disorders, fistula rates, type of reconstruction, prolonged stay in an intensive care unit (ICU) and in hospital, donor site, flap size, length of operation, and number of follow-up visits. Flap success was 97.8% (44 of 45) in the ALTFF group and 97.4% (113 of 116) for RFFF. The mean size was higher in ALTFF than in RFFF (110 vs. 29 cm2; P < 0.001). ALTFF needed less postoperative care and developed fewer wound healing disorders (P = 0.005 and P = 0.035). Operative time was significantly shorter in RFFF reconstructions (P = 0.020). Intraoperative arterial spasm was the most significant complication in ALTF and postoperative venous thrombosis in RFFF. ALTFF has distinct advantages over RFFF with respect to intraoral reconstruction. However, the RFFF remains as a very reliable flap because of the minimal variability in its anatomy.
- 11 February 2011
- Published by Springer Nature in Annals of Surgical Oncology
- Vol. 18 (7) , 1988-1994
Microsurgical Reconstruction of the Oral Cavity with Free Flaps from the Anterolateral Thigh and the Radial Forearm: A Comparison of Perioperative Data from 161 Cases
Free flaps are commonly used for reconstruction of extensive tumor resection defects in the oral cavity. The radial forearm free flap (RFFF) is the most frequent choice. However, a major problem of RFFF is a limitation in its size. The anterolateral thigh free flap (ALTFF) has become popular as an alternative donor site in maxillofacial surgery. We have compared patient data after reconstructions of the oral cavity using the RFFF or ALTFF. Perioperative data of 161 oral cancer patients with ALTFF (45) or RFFF (116) reconstructions were reviewed and statistically analyzed for the following characteristics: sex, histology, primary tumor localization, defect type, American Society of Anesthesiology score, success rates, revisions, wound healing disorders, fistula rates, type of reconstruction, prolonged stay in an intensive care unit (ICU) and in hospital, donor site, flap size, length of operation, and number of follow-up visits. Flap success was 97.8% (44 of 45) in the ALTFF group and 97.4% (113 of 116) for RFFF. The mean size was higher in ALTFF than in RFFF (110 vs. 29 cm2; P < 0.001). ALTFF needed less postoperative care and developed fewer wound healing disorders (P = 0.005 and P = 0.035). Operative time was significantly shorter in RFFF reconstructions (P = 0.020). Intraoperative arterial spasm was the most significant complication in ALTF and postoperative venous thrombosis in RFFF. ALTFF has distinct advantages over RFFF with respect to intraoral reconstruction. However, the RFFF remains as a very reliable flap because of the minimal variability in its anatomy.
- 13 May 2009
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 90B (2) , 930-938
A bioartificial surgical patch from multilayered human amniotic membrane—In vivo investigations in a rat model
The study was performed to evaluate the suitability of glycerol‐cryopreserved human amniotic membrane (HAM) as a surgical patch, far from its common use in ophthalmic surgery. In vivo experiments in rat models were performed to study the degradation patterns, biocompatibility, postoperative tissue formation and its suitability for abdominal wall closure. Degradation and thickness of the membranes were assessed over a period of 60 days after subdermal implantation of monolayer and multilayer HAM in 96 immunocompetent and immunosuppressed rats. The tissue response was mild, and histological analysis evaluated that multilayer application and immunosuppression prolonged graft survival significantly. In a second rat model, another 18 animals were monitored over a period of 28 days after abdominal wall reconstruction with multilayered HAM. Polypropylene mesh (Prolene®) and polyglactin910/polydioxanon patches (Ethisorb®) served as controls. Gross examination and histological analysis proved that multilayer HAM was a sufficient material for abdominal wall closure in comparison with the polypropylene mesh and was superior to the polyglactin910/polydioxanon patch. Additionally, significantly reduced postoperative intraabdominal adhesions were observed when compared to the polyglactin910/polydioxanon patch. This study demonstrates that HAM is a biocompatible, resorbable surgical patch in a rat xenotransplantation model and serves as a mechanically sufficient material for abdominal wall closure in a small animal model. These findings are encouraging and justify further research for the use of cryopreserved human amniotic membrane in soft tissue repair. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009
- 13 May 2009
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 90B (2) , 930-938
A bioartificial surgical patch from multilayered human amniotic membrane—In vivo investigations in a rat model
The study was performed to evaluate the suitability of glycerol‐cryopreserved human amniotic membrane (HAM) as a surgical patch, far from its common use in ophthalmic surgery. In vivo experiments in rat models were performed to study the degradation patterns, biocompatibility, postoperative tissue formation and its suitability for abdominal wall closure. Degradation and thickness of the membranes were assessed over a period of 60 days after subdermal implantation of monolayer and multilayer HAM in 96 immunocompetent and immunosuppressed rats. The tissue response was mild, and histological analysis evaluated that multilayer application and immunosuppression prolonged graft survival significantly. In a second rat model, another 18 animals were monitored over a period of 28 days after abdominal wall reconstruction with multilayered HAM. Polypropylene mesh (Prolene®) and polyglactin910/polydioxanon patches (Ethisorb®) served as controls. Gross examination and histological analysis proved that multilayer HAM was a sufficient material for abdominal wall closure in comparison with the polypropylene mesh and was superior to the polyglactin910/polydioxanon patch. Additionally, significantly reduced postoperative intraabdominal adhesions were observed when compared to the polyglactin910/polydioxanon patch. This study demonstrates that HAM is a biocompatible, resorbable surgical patch in a rat xenotransplantation model and serves as a mechanically sufficient material for abdominal wall closure in a small animal model. These findings are encouraging and justify further research for the use of cryopreserved human amniotic membrane in soft tissue repair. © 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2009