TTToyohiko Tanaka

Toyohiko Tanaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Toyohiko Tanaka has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Newly Developed Biodegradable Stents for Benign Gastrointestinal Tract Stenoses: A Preliminary Clinical Trial

    by Toyohiko Tanaka, Masashi Takahashi, Norihisa Nitta, Akira Furukawa, Akira Andoh, Yasuharu Saito, Yoshihide Fujiyama, Kiyoshi Murata

    We developed an Ultraflex-type stent by knitting polylactic acid monofilaments. The purpose of this study was to evaluate the stent’s clinical usefulness for treating benign stenoses in the gastrointestinal tract. The radial force of the biodegradable stent was compared with those of commercially available metallic stents. The measured radial force of the new biodegradable stent was higher than that of commercially available metallic stents. The biodegradable stents were applied in 2 patients with benign gastrointestinal stenoses. The first patient was a 19-year-old female with esophageal stenosis, due to drinking of caustic potash in an attempt to commit suicide. The second patient was a 75-year-old male who had a stenosis at the anastomotic site after esophageal cancer resection. In both cases, the placement of the stent was performed successfully, and the patients’ complaints improved immediately after stent placement. There were no complications during stent placement. The stenosis had not recurred at the six-month follow-up examination. In conclusion, the newly developed biodegradable stents were useful in treating benign stenoses of the alimentary tract.


  • The First Trial of Phase Contrast Imaging for Digital Full-Field Mammography Using a Practical Molybdenum X-Ray Tube

    by Toyohiko Tanaka, Chika Honda, Satoru Matsuo, Kazuo Noma, Hiromu Oohara, Norihisa Nitta, Shinichi Ota, Keiko Tsuchiya, Yoko Sakashita, Aya Yamada, et al.

    The image quality of a newly developed full-field digital phase contrast mammography (PCM) system and of a conventional screen-film (SF) mammography system were compared via images of a phantom and receiver operating characteristic (ROC) analysis of clinical images. Magnified (1.75×) PCM images were scanned (sampling rate, 43.75 μm) and then reduced to original-sized, 25-micron pixel images printed on photothermographic film. Along with corresponding SF images, the phantom images were evaluated subjectively, and the clinical images of 38 patients were subjected to ROC analysis of mass and microcalcification. In the image quality of a phantom, the PCM exceeded the SF. In both mass and microcalcification, the ROC analysis Az values of the PCM clinical images surpassed those of the SF images. The PCM provides better images than the SF. Clinical trials suggest superior detection of both mass and microcalcification by full-field digital PCM over conventional SF mammography.