Georges Karam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Georges Karam has a total of 57 co-authors. Here are the top co-authors by number of shared publications:
J P Soulillou
11 shared publicationsD Cantarovich
Service de Néphrologie, Nantes University Hospital, France
10 shared publicationsM Hourmant
9 shared publications- Olivier Bouchot
CHU de Nantes, place Ricordeau
9 shared publications J Dantal
7 shared publicationsJ Paineau
6 shared publications
Latest Publications
- 1 January 2011
- Published by Elsevier in Transplantation Proceedings
- Vol. 43 (1) , 387-390
Bladder Dysfunction Following Renal Transplantation Is It Predictable?
- 1 January 2011
- Published by Elsevier in Transplantation Proceedings
- Vol. 43 (1) , 387-390
Bladder Dysfunction Following Renal Transplantation Is It Predictable?
- 1 February 2008
- Published by JLE in Nephrologie & Therapeutique
- Vol. 4 (1) , 69-71
La transplantation à partir d’un donneur vivant. La chirurgie et ses complications
Although nephrectomy by open surgery is the most used technique for the extraction of kidney transplants in the living donor, nephrectomy under laparaoscopy is increasingly practiced. Laparoscopic nephrectomy is less invasive and performed under videoscopy control, after insufflation of the peritoneal cavity. Three to four incisions are done in order to enter the surgical instruments. The kidney is extracted through a horizontal sus-pubic incision. The exposition is either exclusively transperitoneal, retroperitoneal or hand assisted. The advantages of laparoscopy are esthetical, financial due to a shorter hospitalisation and a quicker recovery, as well a confort for the donor. The disadvantages are a longer warm ischemia time and possibly a higher risk of delayed graft function. Randomised studies having compared laparoscopy and open surgery in the living donor have not find any significant difference regarding the per- and perioperative in the complications.
- 1 February 2008
- Published by JLE in Nephrologie & Therapeutique
- Vol. 4 (1) , 69-71
La transplantation à partir d’un donneur vivant. La chirurgie et ses complications
Although nephrectomy by open surgery is the most used technique for the extraction of kidney transplants in the living donor, nephrectomy under laparaoscopy is increasingly practiced. Laparoscopic nephrectomy is less invasive and performed under videoscopy control, after insufflation of the peritoneal cavity. Three to four incisions are done in order to enter the surgical instruments. The kidney is extracted through a horizontal sus-pubic incision. The exposition is either exclusively transperitoneal, retroperitoneal or hand assisted. The advantages of laparoscopy are esthetical, financial due to a shorter hospitalisation and a quicker recovery, as well a confort for the donor. The disadvantages are a longer warm ischemia time and possibly a higher risk of delayed graft function. Randomised studies having compared laparoscopy and open surgery in the living donor have not find any significant difference regarding the per- and perioperative in the complications.
- 1 December 2007
- Published by Elsevier in Annales d'Urologie
- Vol. 41 (6) , 261-275
Complications chirurgicales de la transplantation rénale
- 1 December 2007
- Published by Elsevier in Annales d'Urologie
- Vol. 41 (6) , 261-275
Complications chirurgicales de la transplantation rénale
- Open Access
- 1 February 2006
- Published by Elsevier in American Journal of Transplantation
- Vol. 6 (2) , 352-356
Late Ureteral Stenosis Following Renal Transplantation: Risk Factors and Impact on Patient and Graft Survival
- 1 February 2006
- Published by Elsevier in American Journal of Transplantation
- Vol. 6 (2) , 352-356
Open AccessLate Ureteral Stenosis Following Renal Transplantation: Risk Factors and Impact on Patient and Graft Survival
- 1 February 2004
- Vol. 14 (1) , 19-23
[Results and surgical complications of pancreas transplantation with enteric exocrine drainage].
The objective of this study was to evaluate the results and surgical complications of total pancreas transplantation with enteric exocrine drainage since the beginning of our experience with this type of transplantation. From November 1999 to December 2002, 62 total pancreas transplantations were performed, consisting of 51 combined kidney-pancreas transplantations, 10 after renal transplantation and 1 pancreas-liver transplantation. Kidneys and pancreases were washed and stored in either Belzer solution or Celsior solution. Transplantation was performed via a midline transperitoneal incision with venous anastomosis at the root of the inferior vena cava (54 cases) or, more recently, in the superior mesenteric vein (8 cases). The arterial anastomosis was then performed in the right common iliac artery. Exocrine drainage was performed by side-to-side anastomosis between the donor duodenum and the recipient jejunum. The kidney was transplanted onto the left external iliac vessels and was extraperitonealised. The mean age of the recipients and donors was 41 +/- 9 years and 33 +/- 11 years, respectively. The mean cold ischaemia time was 14 +/- 5 hours. Four pancreases were lost due to venous thrombosis, 1 due to severe pancreatitis with haemodynamic collapse and venous thrombosis and another due to total necrosis of the duodenum. Seventeen patients (27%) were reoperated, including 10 during the first postoperative month and 7 during the first year. No cases of fistula of the gastrointestinal anastomosis were observed. All patients with a functional graft no longer required exogenous insulin. The actuarial patient and graft three-year survival was 96% and 86% respectively. Despite their high frequency, surgical complications did not have any harmful effects on either control of diabetes or graft and patient survival.
- 1 February 2004
- Vol. 14 (1) , 19-23
[Results and surgical complications of pancreas transplantation with enteric exocrine drainage].
The objective of this study was to evaluate the results and surgical complications of total pancreas transplantation with enteric exocrine drainage since the beginning of our experience with this type of transplantation. From November 1999 to December 2002, 62 total pancreas transplantations were performed, consisting of 51 combined kidney-pancreas transplantations, 10 after renal transplantation and 1 pancreas-liver transplantation. Kidneys and pancreases were washed and stored in either Belzer solution or Celsior solution. Transplantation was performed via a midline transperitoneal incision with venous anastomosis at the root of the inferior vena cava (54 cases) or, more recently, in the superior mesenteric vein (8 cases). The arterial anastomosis was then performed in the right common iliac artery. Exocrine drainage was performed by side-to-side anastomosis between the donor duodenum and the recipient jejunum. The kidney was transplanted onto the left external iliac vessels and was extraperitonealised. The mean age of the recipients and donors was 41 +/- 9 years and 33 +/- 11 years, respectively. The mean cold ischaemia time was 14 +/- 5 hours. Four pancreases were lost due to venous thrombosis, 1 due to severe pancreatitis with haemodynamic collapse and venous thrombosis and another due to total necrosis of the duodenum. Seventeen patients (27%) were reoperated, including 10 during the first postoperative month and 7 during the first year. No cases of fistula of the gastrointestinal anastomosis were observed. All patients with a functional graft no longer required exogenous insulin. The actuarial patient and graft three-year survival was 96% and 86% respectively. Despite their high frequency, surgical complications did not have any harmful effects on either control of diabetes or graft and patient survival.
- 1 June 2003
- Vol. 13 (3) , 523-6
[Endoscopic incision of uretero-vesical junction after renal transplantation].
Stenosis of the ureterovesical reimplantation is one of the most frequent urological complications after renal transplantation. It can be treated surgically or endoscopically (dilatation, ureteric stent or Acucise). The authors present the results of a new endoscopic electrode-scalpel incision technique used as first-line treatment in 9 patients with stenosis of the distal centimetre of the ureter.
- 1 June 2003
- Vol. 13 (3) , 523-6
[Endoscopic incision of uretero-vesical junction after renal transplantation].
Stenosis of the ureterovesical reimplantation is one of the most frequent urological complications after renal transplantation. It can be treated surgically or endoscopically (dilatation, ureteric stent or Acucise). The authors present the results of a new endoscopic electrode-scalpel incision technique used as first-line treatment in 9 patients with stenosis of the distal centimetre of the ureter.
- 1 February 2003
- Vol. 13 (1) , 46-9
[Safety of the use of Celsior in kidney-pancreas transplantation].
The objective of this prospective observation study was to evaluate the safety of use of Celsior extracellular solution, initially designed for cardiac preservation, in kidney-pancreas transplantation. From August 1999 to July 2000, 140 kidneys and 9 pancreases were harvested from 71 cadaveric donors with a mean age of 34 +/- 11 years, washed and preserved until transplantation with Celsior. One hundred and thirty one isolated renal transplantations and 9 combined kidney-pancreas transplantations were performed. The mean age of isolated kidney recipients and kidney-pancreas recipients was 42 +/- 13 years (range: 4-71 years) and 39 +/- 7 years (range: 31-52 years), respectively. The mean cold ischaemia time was 21 +/- 8 hours (range: 4-45) for kidneys and 11.43 +/- 2.9 hours (range: 6-15 hours) for pancreases. No cardiac or haemodynamic incidents were observed during organ revascularization. No electrolyte or haematological abnormalities were observed postoperatively. The one-year graft survival rate was 96% (range: 93%-99%) for kidneys and 89% (range: 55%-100%) for pancreases. Patient survival was 100%. Return of renal transplant function was delayed in 14% (8-20%) of patients, requiring dialysis during the first week. Mean serum creatinine at 3 months and at 1 year was 123 +/- 41 mumol/l and 118.5 +/- 33.8 mumol/l, respectively. One pancreas and one kidney were lost due to venous thrombosis on D2 and D4. Two patients in the kidney-pancreas group were reoperated.
- 1 February 2003
- Vol. 13 (1) , 46-9
[Safety of the use of Celsior in kidney-pancreas transplantation].
The objective of this prospective observation study was to evaluate the safety of use of Celsior extracellular solution, initially designed for cardiac preservation, in kidney-pancreas transplantation. From August 1999 to July 2000, 140 kidneys and 9 pancreases were harvested from 71 cadaveric donors with a mean age of 34 +/- 11 years, washed and preserved until transplantation with Celsior. One hundred and thirty one isolated renal transplantations and 9 combined kidney-pancreas transplantations were performed. The mean age of isolated kidney recipients and kidney-pancreas recipients was 42 +/- 13 years (range: 4-71 years) and 39 +/- 7 years (range: 31-52 years), respectively. The mean cold ischaemia time was 21 +/- 8 hours (range: 4-45) for kidneys and 11.43 +/- 2.9 hours (range: 6-15 hours) for pancreases. No cardiac or haemodynamic incidents were observed during organ revascularization. No electrolyte or haematological abnormalities were observed postoperatively. The one-year graft survival rate was 96% (range: 93%-99%) for kidneys and 89% (range: 55%-100%) for pancreases. Patient survival was 100%. Return of renal transplant function was delayed in 14% (8-20%) of patients, requiring dialysis during the first week. Mean serum creatinine at 3 months and at 1 year was 123 +/- 41 mumol/l and 118.5 +/- 33.8 mumol/l, respectively. One pancreas and one kidney were lost due to venous thrombosis on D2 and D4. Two patients in the kidney-pancreas group were reoperated.
- 1 February 2001
- Vol. 11 (1) , 127-31
[Accuracy of pressure measurements obtained with a new rectal balloon catheter].
The accuracy of measurements performed by a balloon catheter used to record abdominal pressure during urodynamic investigations was verified on a test bench. To study the accuracy and precision of the pressure measurements obtained with a new rectal balloon catheter (ref. 95018 Laboratoires Vermed), designed to record abdominal pressure during urodynamic assessments. The clinical value of this catheter, using air for pressure transmission, is its simplicity, as there is no contamination of the perfusion circuit or transducer, no purging of the circuit, and artefacts related to movements of the tubing are eliminated. The catheter was placed in a pressure chamber fitted with a precise, calibrated regulation system allowing programmed pressure variations from 10 to 150 cmH2O. Pressures recorded by the test catheter were compared to reference pressures applied to the chamber. The frequency of acquisition of pressure measurements was 100 Hertz and the resolution was 10 Hertz. This model was used to study the accuracy of pressure measurements and the response times of the catheter. Measurements were performed with a volume of 2 ml of air introduced into the catheter (volume recommended by the manufacturer), and the optimal volume was investigated by inflating the catheter until the best result was obtained. The evaluation was based on calculation of the mean difference observed between the two measurements and the scatter of the differences observed. When the catheter was filled with 2 ml of air, pressures measured by the catheter were overestimated an average of 1.1 cmH2O (standard deviation = 1), and 95% of the differences between the two measurements were within +/- 2.15 cmH2O. The optimal air volume was found to be 1.5 ml. With this air volume, no significant difference was observed between the two measurements. The mean observed difference was 0.2 cmH2O (SD = 1.2), which means that 95% of the differences were situated within the range of +/- 2.35 cmH2O. The pressure recording method with this new catheter is validated in terms of physical parameters.
- 1 February 2001
- Vol. 11 (1) , 127-31
[Accuracy of pressure measurements obtained with a new rectal balloon catheter].
The accuracy of measurements performed by a balloon catheter used to record abdominal pressure during urodynamic investigations was verified on a test bench. To study the accuracy and precision of the pressure measurements obtained with a new rectal balloon catheter (ref. 95018 Laboratoires Vermed), designed to record abdominal pressure during urodynamic assessments. The clinical value of this catheter, using air for pressure transmission, is its simplicity, as there is no contamination of the perfusion circuit or transducer, no purging of the circuit, and artefacts related to movements of the tubing are eliminated. The catheter was placed in a pressure chamber fitted with a precise, calibrated regulation system allowing programmed pressure variations from 10 to 150 cmH2O. Pressures recorded by the test catheter were compared to reference pressures applied to the chamber. The frequency of acquisition of pressure measurements was 100 Hertz and the resolution was 10 Hertz. This model was used to study the accuracy of pressure measurements and the response times of the catheter. Measurements were performed with a volume of 2 ml of air introduced into the catheter (volume recommended by the manufacturer), and the optimal volume was investigated by inflating the catheter until the best result was obtained. The evaluation was based on calculation of the mean difference observed between the two measurements and the scatter of the differences observed. When the catheter was filled with 2 ml of air, pressures measured by the catheter were overestimated an average of 1.1 cmH2O (standard deviation = 1), and 95% of the differences between the two measurements were within +/- 2.15 cmH2O. The optimal air volume was found to be 1.5 ml. With this air volume, no significant difference was observed between the two measurements. The mean observed difference was 0.2 cmH2O (SD = 1.2), which means that 95% of the differences were situated within the range of +/- 2.35 cmH2O. The pressure recording method with this new catheter is validated in terms of physical parameters.
- 1 December 1997
- Vol. 7 (6) , 948-52
[Outcome of nephrogenic metaplasia of the bladder in kidney transplant recipients].
To evaluate the risk of recurrence and malignant degeneration of vesical nephrogenic metaplasia in renal transplant recipients. Fourteen patients with known nephrogenic metaplasia were systematically followed. Vesical biopsies were performed with a resector, stained with eosin haemalun saffron, analysed and compared to initial results. Labelling by anti-EBV and anti-CMV monoclonal antibodies was performed in 5 cases of intense inflammatory reactions. All patients were males, with a median age of 39 years. Nephrogenic metaplasia had been diagnosed 7 to 80 months after renal transplantation (median = 37.8). Twelve patients were reviewed 5 to 116 months after the initial diagnosis (median = 52). Relapse was observed in 83% of cases, but without any malignant degeneration. Nephrogenic metaplasia is therefore a benign recurrent disease. The importance of the initial blood supply and fibrosis in the case of recurrence suggest a disorder of the blood supply, probably traumatic in origin. Only symptomatic patients are currently followed.
- 1 December 1997
- Vol. 7 (6) , 948-52
[Outcome of nephrogenic metaplasia of the bladder in kidney transplant recipients].
To evaluate the risk of recurrence and malignant degeneration of vesical nephrogenic metaplasia in renal transplant recipients. Fourteen patients with known nephrogenic metaplasia were systematically followed. Vesical biopsies were performed with a resector, stained with eosin haemalun saffron, analysed and compared to initial results. Labelling by anti-EBV and anti-CMV monoclonal antibodies was performed in 5 cases of intense inflammatory reactions. All patients were males, with a median age of 39 years. Nephrogenic metaplasia had been diagnosed 7 to 80 months after renal transplantation (median = 37.8). Twelve patients were reviewed 5 to 116 months after the initial diagnosis (median = 52). Relapse was observed in 83% of cases, but without any malignant degeneration. Nephrogenic metaplasia is therefore a benign recurrent disease. The importance of the initial blood supply and fibrosis in the case of recurrence suggest a disorder of the blood supply, probably traumatic in origin. Only symptomatic patients are currently followed.
- 1 April 1994
- Vol. 26 (2) , 416
Five-year experience with segmental duct-occluded pancreatic grafts.