Hiroyuki Inoue
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hiroyuki Inoue has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Kenji Tsujikawa
National Research Institute of Police Science
15 shared publicationsYuko T. Iwata
National Research Institute of Police Science
13 shared publications- Tatsuyuki Kanamori
Third Department of Forensic Science National Research Institute of Police Science Kashiwa Chiba Japan
7 shared publications - Kenji Kuwayama
Third Department of Forensic Science National Research Institute of Police Science Kashiwa Chiba Japan
6 shared publications Tatsuyuki Kanamori
National Research Institute of Police Science, Kashiwa, Japan
6 shared publicationsKenji Kuwayama
National Research Institute of Police Science, Kashiwa, Japan
5 shared publications
Latest Publications
- 1 January 2017
- Published by Japanese Association of Forensic Science and Technology in Japanese Journal of Forensic Science and Technology
- Vol. 22 (1) , 9-24
Evaluation of drug identification and discrimination ability of portable spectrometers
We have evaluated the identification and differentiation abilities of three portable spectrometers (TruNarc: Raman spectrometer, Target-ID: infrared spectrometer, NIRSCAN-MKII: near-infrared spectrometer) for on-site drug screening. Identification abilities were evaluated using samples containing methamphetamine (MA) and cocaine (COC), including case samples and mixtures of these drugs with diluents. Differentiation ability was evaluated using case samples that did not contain MA or COC and compounds having similar chemical structures to MA and α-pyrrolidinovalerophenone (α-PVP). All three spectrometers commonly showed acceptable true-positive rates (93.2% to 96.6%) for the MA-containing case samples. In addition, their true-positive rates for the 25:75 mixtures of MA hydrochloride and diluents were within 47% to 67%. On the other hand, these spectrometers gave lower true-positive rates (76% to 88%) for the COC-containing case samples than those for the MA-containing case samples. NIRSCAN-MKII showed obviously lower true-positive rates for the 25:75 mixtures of COC hydrochloride and diluents than the other spectrometers (NIRSCAN-MKII: 10%; Target-ID: 90%; TruNarc: 52%). Moreover, all three spectrometers gave false-positives to the compounds similar to MA and α-PVP. By implementing strict criteria for positive identification, the false positives from Target-ID and NIRSCAN-MKII were prevented but consequentially allowed an increase of false negatives. This increase of false negatives by NIRSCAN-MKII was suppressed by adding the spectra of the COC hydrochloride and diluent mixtures to the spectrum library. For TruNarc, the false positives may be caused by the mixture analysis algorithm. Excluding some spectra from the spectrum library or from the target of the mixture analysis prevented identification of these compounds; however, it inhibited the false positives with minimum increase of false negatives for MA-containing and COC-containing samples. We concluded that i) without improvements, all three spectrometers had a high risk of false positives, ii) improvement of software would lower the identification range but diminish the risk of false positives, and iii) all three spectrometers were applicable to on-site screening, specifically for MA-containing and COC-containing samples after the improvement.
- 1 January 2017
- Published by Japanese Association of Forensic Science and Technology in Japanese Journal of Forensic Science and Technology
- Vol. 22 (1) , 9-24
Evaluation of drug identification and discrimination ability of portable spectrometers
We have evaluated the identification and differentiation abilities of three portable spectrometers (TruNarc: Raman spectrometer, Target-ID: infrared spectrometer, NIRSCAN-MKII: near-infrared spectrometer) for on-site drug screening. Identification abilities were evaluated using samples containing methamphetamine (MA) and cocaine (COC), including case samples and mixtures of these drugs with diluents. Differentiation ability was evaluated using case samples that did not contain MA or COC and compounds having similar chemical structures to MA and α-pyrrolidinovalerophenone (α-PVP). All three spectrometers commonly showed acceptable true-positive rates (93.2% to 96.6%) for the MA-containing case samples. In addition, their true-positive rates for the 25:75 mixtures of MA hydrochloride and diluents were within 47% to 67%. On the other hand, these spectrometers gave lower true-positive rates (76% to 88%) for the COC-containing case samples than those for the MA-containing case samples. NIRSCAN-MKII showed obviously lower true-positive rates for the 25:75 mixtures of COC hydrochloride and diluents than the other spectrometers (NIRSCAN-MKII: 10%; Target-ID: 90%; TruNarc: 52%). Moreover, all three spectrometers gave false-positives to the compounds similar to MA and α-PVP. By implementing strict criteria for positive identification, the false positives from Target-ID and NIRSCAN-MKII were prevented but consequentially allowed an increase of false negatives. This increase of false negatives by NIRSCAN-MKII was suppressed by adding the spectra of the COC hydrochloride and diluent mixtures to the spectrum library. For TruNarc, the false positives may be caused by the mixture analysis algorithm. Excluding some spectra from the spectrum library or from the target of the mixture analysis prevented identification of these compounds; however, it inhibited the false positives with minimum increase of false negatives for MA-containing and COC-containing samples. We concluded that i) without improvements, all three spectrometers had a high risk of false positives, ii) improvement of software would lower the identification range but diminish the risk of false positives, and iii) all three spectrometers were applicable to on-site screening, specifically for MA-containing and COC-containing samples after the improvement.
- 1 January 2016
- Published by Japanese Association of Forensic Science and Technology in Japanese Journal of Forensic Science and Technology
- Vol. 21 (2) , 139-147
Simultaneous analysis of 18 compounds of fentanyl and its analogues by TLC, GC/MS and LC/MS
- 1 January 2016
- Published by Japanese Association of Forensic Science and Technology in Japanese Journal of Forensic Science and Technology
- Vol. 21 (2) , 139-147
Simultaneous analysis of 18 compounds of fentanyl and its analogues by TLC, GC/MS and LC/MS
- 1 January 2016
- Published by Japanese Association of Forensic Science and Technology in Japanese Journal of Forensic Science and Technology
- Vol. 21 (2) , 109-124
Study of cannabis discrimination by hierarchical cluster analysis
- 1 January 2016
- Published by Japanese Association of Forensic Science and Technology in Japanese Journal of Forensic Science and Technology
- Vol. 21 (2) , 109-124
Study of cannabis discrimination by hierarchical cluster analysis
- Open Access
- 14 November 2015
- Published by Springer Nature in Forensic Toxicology
- Vol. 34 (1) , 125-132
Differentiation of ring-substituted bromoamphetamine analogs by gas chromatography–tandem mass spectrometry
There has been a rapid increase over the last decade in the appearance of new non-controlled psychoactive substances. Minor changes in the chemical structures of these compounds, such as the extension of an alkyl residue or replacement of a single substituent, are regularly made to avoid regulatory control, leading to the manufacture of many new potentially dangerous drugs. Bromoamphetamine analogs (bromoamphetamine [Br-AP] and bromomethamphetamine (Br-MA]) are ring-substituted amphetamines that can behave as stimulants, as well as exhibiting inhibitory activity towards monoamine oxidases in the same way as amphetamines. Gas chromatography–tandem mass spectrometry (GC–MS–MS) was used in this study to differentiate ring-substituted bromoamphetamine analogs. Free bases, trifluoroacetyl derivatives, and trimethylsilyl (TMS) derivatives of six analytes were successfully separated using DB-1ms and DB-5ms columns. Electron ionization MS–MS analysis of the TMS derivatives allowed for the differentiation of three regioisomers. TMS derivatives of 2-positional isomers provided significant product ions. The spectral patterns of 3- and 4-positional isomers were different. Chemical ionization MS–MS analysis of free bases for [M+H–HBr]+ions atm/z134 and 148 allowed for differentiation of the regioisomers. The spectra of 2-positional isomers contained characteristic product ions formed by dehydrogenation atm/z132 andm/z146 for 2Br-AP and 2Br-MA, respectively. The spectra of 3-positional isomers contained α-cleaved iminium cations as the base peaks. The spectra of 4-positional isomers showed a tropylium cation atm/z91 as the base peak. These results demonstrate that GC–MS–MS can be used for the differentiation of regioisomeric Br-AP analogs in forensic practice.
- 14 November 2015
- Published by Springer Nature in Forensic Toxicology
- Vol. 34 (1) , 125-132
Open AccessDifferentiation of ring-substituted bromoamphetamine analogs by gas chromatography–tandem mass spectrometry
There has been a rapid increase over the last decade in the appearance of new non-controlled psychoactive substances. Minor changes in the chemical structures of these compounds, such as the extension of an alkyl residue or replacement of a single substituent, are regularly made to avoid regulatory control, leading to the manufacture of many new potentially dangerous drugs. Bromoamphetamine analogs (bromoamphetamine [Br-AP] and bromomethamphetamine (Br-MA]) are ring-substituted amphetamines that can behave as stimulants, as well as exhibiting inhibitory activity towards monoamine oxidases in the same way as amphetamines. Gas chromatography–tandem mass spectrometry (GC–MS–MS) was used in this study to differentiate ring-substituted bromoamphetamine analogs. Free bases, trifluoroacetyl derivatives, and trimethylsilyl (TMS) derivatives of six analytes were successfully separated using DB-1ms and DB-5ms columns. Electron ionization MS–MS analysis of the TMS derivatives allowed for the differentiation of three regioisomers. TMS derivatives of 2-positional isomers provided significant product ions. The spectral patterns of 3- and 4-positional isomers were different. Chemical ionization MS–MS analysis of free bases for [M+H–HBr]+ions atm/z134 and 148 allowed for differentiation of the regioisomers. The spectra of 2-positional isomers contained characteristic product ions formed by dehydrogenation atm/z132 andm/z146 for 2Br-AP and 2Br-MA, respectively. The spectra of 3-positional isomers contained α-cleaved iminium cations as the base peaks. The spectra of 4-positional isomers showed a tropylium cation atm/z91 as the base peak. These results demonstrate that GC–MS–MS can be used for the differentiation of regioisomeric Br-AP analogs in forensic practice.
- Open Access
- 19 May 2015
- Published by Springer Nature in Forensic Toxicology
- Vol. 33 (2) , 338-347
Differentiation of regioisomeric chloroamphetamine analogs using gas chromatography–chemical ionization-tandem mass spectrometry
In recent years, a large number of clandestinely synthesized new psychoactive substances with high structural variety have been detected in forensic samples. Analytical differentiation of regioisomers is a significant issue in forensic drug analysis, because, in most cases, legal controls are placed on only one or two of the conceivable isomers. In this study, gas chromatography–tandem mass spectrometry (GC–MS–MS) was used to differentiate the regioisomers of chloroamphetamine analogs (chloroamphetamines and chloromethamphetamines) synthesized in the authors′ laboratories. Free bases, trifluoroacetyl derivatives, and trimethylsilyl derivatives were subjected to GC–MS–MS using DB-1ms, DB-5ms, and DB-17ms capillary columns, respectively. The regioisomers of chloroamphetamine analogs in all forms were well separated on the DB-5ms column. The electron ionization mass spectra of the chloroamphetamine analogs gave very little structural information for differentiation among these analogs, even after trifluoroacetyl and trimethylsilyl derivatization of the analytes. Characteristic product ions of the 2-positional isomers were observed by electron ionization-MS–MS. In contrast, chemical ionization-MS–MS of the free bases provided more structural information about chloride position on the aromatic ring when [M+H–HCl]+was selected as a precursor ion. The results suggest that a combination of chromatographic analysis and MS–MS supports differentiation for regioisomers of chloroamphetamine analogs.
- 19 May 2015
- Published by Springer Nature in Forensic Toxicology
- Vol. 33 (2) , 338-347
Open AccessDifferentiation of regioisomeric chloroamphetamine analogs using gas chromatography–chemical ionization-tandem mass spectrometry
In recent years, a large number of clandestinely synthesized new psychoactive substances with high structural variety have been detected in forensic samples. Analytical differentiation of regioisomers is a significant issue in forensic drug analysis, because, in most cases, legal controls are placed on only one or two of the conceivable isomers. In this study, gas chromatography–tandem mass spectrometry (GC–MS–MS) was used to differentiate the regioisomers of chloroamphetamine analogs (chloroamphetamines and chloromethamphetamines) synthesized in the authors′ laboratories. Free bases, trifluoroacetyl derivatives, and trimethylsilyl derivatives were subjected to GC–MS–MS using DB-1ms, DB-5ms, and DB-17ms capillary columns, respectively. The regioisomers of chloroamphetamine analogs in all forms were well separated on the DB-5ms column. The electron ionization mass spectra of the chloroamphetamine analogs gave very little structural information for differentiation among these analogs, even after trifluoroacetyl and trimethylsilyl derivatization of the analytes. Characteristic product ions of the 2-positional isomers were observed by electron ionization-MS–MS. In contrast, chemical ionization-MS–MS of the free bases provided more structural information about chloride position on the aromatic ring when [M+H–HCl]+was selected as a precursor ion. The results suggest that a combination of chromatographic analysis and MS–MS supports differentiation for regioisomers of chloroamphetamine analogs.
- 1 March 2015
- Published by Elsevier in Forensic Science International
- Vol. 248, 48-54
Instability of the hydrochloride salts of cathinone derivatives in air
- 1 March 2015
- Published by Elsevier in Forensic Science International
- Vol. 248, 48-54
Instability of the hydrochloride salts of cathinone derivatives in air
- 1 January 2014
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 63 (3) , 221-231
Profiling of Methamphetamine
- 1 January 2014
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 63 (3) , 221-231
Profiling of Methamphetamine
- 11 September 2013
- Published by Springer Nature in Forensic Toxicology
- Vol. 32 (1) , 154-161
Simultaneous determination of tryptamine analogues in designer drugs using gas chromatography–mass spectrometry and liquid chromatography–tandem mass spectrometry
- 11 September 2013
- Published by Springer Nature in Forensic Toxicology
- Vol. 32 (1) , 154-161
Simultaneous determination of tryptamine analogues in designer drugs using gas chromatography–mass spectrometry and liquid chromatography–tandem mass spectrometry
- 3 April 2013
- Published by Springer Nature in Forensic Toxicology
- Vol. 31 (2) , 241-250
Differentiation of regioisomeric fluoroamphetamine analogs by gas chromatography–mass spectrometry and liquid chromatography–tandem mass spectrometry
- 3 April 2013
- Published by Springer Nature in Forensic Toxicology
- Vol. 31 (2) , 241-250
Differentiation of regioisomeric fluoroamphetamine analogs by gas chromatography–mass spectrometry and liquid chromatography–tandem mass spectrometry