Sukho Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sukho Park has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Byungkyu Kim
Department of Mechanical and Aerospace Engineering, Korea Aerospace University, 200-1 Hwajeon dong, Deogyang-gu, Goyang-city, Gyeonggi-do, 412-791, Korea
3 shared publications Jeongeun Baek
Nano-Bio Research Center, Korea Institute of Science and Technology, Korea
3 shared publications- Jungyul Park
Department of Mechanical Engineering, Sogang University, 35 Baekbeom-ro (Sinsu-dong), Mapo-gu, Seoul 04107, Republic of Korea
3 shared publications Byungkyu Kim
Nano-Bio Research Center, Korea Institute of Science and Technology, Korea
2 shared publicationsJinseok Kim
Nano-Bio Research Center, Korea Institute of Science and Technology, Korea
2 shared publications- Jong-Oh Park
School of Mechanical Systems Engineering, Chonnam National University, Korea
2 shared publications
Latest Publications
- 19 November 2012
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 227 (9) , 1915-1926
Position-based compensation of electromagnetic fields interference for electromagnetic locomotive microrobot
Recently, the locomotion of a microrobot wirelessly actuated by electromagnetic actuation systems has been studied in many ways. Because of the inherent characteristics of an electromagnetic field, however, the magnetic field of each coil in the electromagnetic actuation system induces magnetic field interferences, which can distort the desired electromagnetic field, preventing the microrobot from following the desired path. In this article, we used two pairs of Helmholtz coils and two pairs of Maxwell coils in a two-dimensional electromagnetic actuation system. Generally, the two pairs of Helmholtz coils generate the torque for the rotation of the microrobot and the two pairs of Maxwell coils generate the propulsion force of the microrobot. Both pairs of Helmholtz and Maxwell coils have to work to simultaneously align and propel the microrobot in a desired direction. In this situation, however, the electromagnetic fields produced by the Helmholtz coils can interfere with those produced by the Maxwell coils. This interference is closely dependent on the position of the microrobot in the region of interest inside the electromagnetic coils system. This means that the alignment direction and propulsion force of the microrobot can be distorted according to the position of the microrobot. Therefore, we propose a compensation algorithm for the electromagnetic field interference using the position information of the microrobot to correct the magnetic field interferences. First, the interference of an electromagnetic field obeying the Biot–Savart law is analyzed by numerical analysis. Second, a position-based compensation algorithm for the locomotion of a microrobot is proposed. Various locomotion tests of a microrobot verified that the proposed compensation algorithm could reduce the normalized average tracking error from 5.25% to 1.92%.
- 19 November 2012
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
- Vol. 227 (9) , 1915-1926
Position-based compensation of electromagnetic fields interference for electromagnetic locomotive microrobot
Recently, the locomotion of a microrobot wirelessly actuated by electromagnetic actuation systems has been studied in many ways. Because of the inherent characteristics of an electromagnetic field, however, the magnetic field of each coil in the electromagnetic actuation system induces magnetic field interferences, which can distort the desired electromagnetic field, preventing the microrobot from following the desired path. In this article, we used two pairs of Helmholtz coils and two pairs of Maxwell coils in a two-dimensional electromagnetic actuation system. Generally, the two pairs of Helmholtz coils generate the torque for the rotation of the microrobot and the two pairs of Maxwell coils generate the propulsion force of the microrobot. Both pairs of Helmholtz and Maxwell coils have to work to simultaneously align and propel the microrobot in a desired direction. In this situation, however, the electromagnetic fields produced by the Helmholtz coils can interfere with those produced by the Maxwell coils. This interference is closely dependent on the position of the microrobot in the region of interest inside the electromagnetic coils system. This means that the alignment direction and propulsion force of the microrobot can be distorted according to the position of the microrobot. Therefore, we propose a compensation algorithm for the electromagnetic field interference using the position information of the microrobot to correct the magnetic field interferences. First, the interference of an electromagnetic field obeying the Biot–Savart law is analyzed by numerical analysis. Second, a position-based compensation algorithm for the locomotion of a microrobot is proposed. Various locomotion tests of a microrobot verified that the proposed compensation algorithm could reduce the normalized average tracking error from 5.25% to 1.92%.
- 7 October 2009
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 115 (3) , 1306-1314
Electrical, dielectric, and electromagnetic shielding properties of polypropylene‐graphite composites
The conducting polymer composite material is desired to have a high dielectric constant and high dissipation factor in low and high frequency ranges, so that it can be used in charge storing devices, decoupling capacitors, and electromagnetic interference (EMI) shielding applications. Currently, on‐going research is trying to enhance the dielectric constant of ceramic powder‐polymer, metal powder‐polymer, and nanotube‐polymer composites in the low frequency region. In this article, we present the dielectric properties of polypropylene (PP)‐graphite (Gr) composites in low and radio frequency ranges. Furthermore, the EMI shielding properties of these composites are examined in the radio frequency range. The PP‐Gr composites were prepared by mixing and the hot compression mold technique. The electrical conductivity and dielectric constant of PP‐Gr composites with graphite volume fraction follow the power law model of percolation theory. The percolation threshold of the composites is estimated to be 0.0257 (∼ 5wt % of Gr). The current of PP‐Gr composites as a function of voltage shows a nearly ohmic behavior above the percolation threshold. Shore‐D hardness of the composites is decreased with the addition of conducting filler. The PP‐Gr composites exhibit a high dielectric constant and high dissipation factor with the addition of graphite in low frequency and radio frequency regions, so they can be used in the proposed applications. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2010
- 7 October 2009
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 115 (3) , 1306-1314
Electrical, dielectric, and electromagnetic shielding properties of polypropylene‐graphite composites
The conducting polymer composite material is desired to have a high dielectric constant and high dissipation factor in low and high frequency ranges, so that it can be used in charge storing devices, decoupling capacitors, and electromagnetic interference (EMI) shielding applications. Currently, on‐going research is trying to enhance the dielectric constant of ceramic powder‐polymer, metal powder‐polymer, and nanotube‐polymer composites in the low frequency region. In this article, we present the dielectric properties of polypropylene (PP)‐graphite (Gr) composites in low and radio frequency ranges. Furthermore, the EMI shielding properties of these composites are examined in the radio frequency range. The PP‐Gr composites were prepared by mixing and the hot compression mold technique. The electrical conductivity and dielectric constant of PP‐Gr composites with graphite volume fraction follow the power law model of percolation theory. The percolation threshold of the composites is estimated to be 0.0257 (∼ 5wt % of Gr). The current of PP‐Gr composites as a function of voltage shows a nearly ohmic behavior above the percolation threshold. Shore‐D hardness of the composites is decreased with the addition of conducting filler. The PP‐Gr composites exhibit a high dielectric constant and high dissipation factor with the addition of graphite in low frequency and radio frequency regions, so they can be used in the proposed applications. © 2009 Wiley Periodicals, Inc. J Appl Polym Sci, 2010
- 10 August 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (11) , 1504-1508
Establishment of a fabrication method for a long-term actuated hybrid cell robot
We developed a novel method to fabricate a crab-like microrobot that can actuate for a long period in a physiological condition. The microrobot backbone was built with a biocompatible and elastic material—polydimethylsiloxane (PDMS)—by using a specially designed 3D molding aligner, and consisted of three strips of PDMS “legs” connected across a “body.” Cardiomyocytes were then plated on the grooved top surface of the backbone, resulting in a high concentration of pulsating cells. These key techniques enabled the microrobot to walk continuously for over ten days. The performance of our crab-like microrobot was measured at an average velocity of 100 µm s−1, and the estimated total distance it travelled was 50 m over a one-week period. Thus, we have demonstrated for the first time a walking robot that exhibited reliable and long-term actuation performances.
- 10 August 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (11) , 1504-1508
Establishment of a fabrication method for a long-term actuated hybrid cell robot
We developed a novel method to fabricate a crab-like microrobot that can actuate for a long period in a physiological condition. The microrobot backbone was built with a biocompatible and elastic material—polydimethylsiloxane (PDMS)—by using a specially designed 3D molding aligner, and consisted of three strips of PDMS “legs” connected across a “body.” Cardiomyocytes were then plated on the grooved top surface of the backbone, resulting in a high concentration of pulsating cells. These key techniques enabled the microrobot to walk continuously for over ten days. The performance of our crab-like microrobot was measured at an average velocity of 100 µm s−1, and the estimated total distance it travelled was 50 m over a one-week period. Thus, we have demonstrated for the first time a walking robot that exhibited reliable and long-term actuation performances.
- 20 July 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (10) , 1367-1370
Micro pumping with cardiomyocyte–polymer hybrid
This paper presents a hybrid micropump actuated by the up–down motion of a dome shaped cell-polymer membrane composite. The contractile force induced from self-beating cardiomyocytes cultured on the membrane causes shrinkage and relaxation of a microchamber, leading to a flow in a microchannel. Flow direction is controlled by the geometry of diffuser/nozzle in the microchannel. The fabrication process is noninvasive to cells, thus, cardiomyocytes can robustly maintain their activity for a long time. The fluid motion in the microchannel was monitored by tracking 2 µm polystyrene beads. A net flow rate of 0.226 nl min−1 was obtained in our microscale device. Our device demonstrates a unique performance of a cell–microdevice hybrid lab-on-a-chip that does not require any external power source, preventing electrical or heat shock to analytes.
- 20 July 2007
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 7 (10) , 1367-1370
Micro pumping with cardiomyocyte–polymer hybrid
This paper presents a hybrid micropump actuated by the up–down motion of a dome shaped cell-polymer membrane composite. The contractile force induced from self-beating cardiomyocytes cultured on the membrane causes shrinkage and relaxation of a microchamber, leading to a flow in a microchannel. Flow direction is controlled by the geometry of diffuser/nozzle in the microchannel. The fabrication process is noninvasive to cells, thus, cardiomyocytes can robustly maintain their activity for a long time. The fluid motion in the microchannel was monitored by tracking 2 µm polystyrene beads. A net flow rate of 0.226 nl min−1 was obtained in our microscale device. Our device demonstrates a unique performance of a cell–microdevice hybrid lab-on-a-chip that does not require any external power source, preventing electrical or heat shock to analytes.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 3377-3382
Paddling based Microrobot for Capsule Endoscopes
Recently, the capsule endoscope can be widely used for the diagnosis of digestive organs. It is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. As a solution of these problems, therefore, a locomotive mechanism of capsule endoscopes has being developed. Our proposed capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. By the novel kinematic relation between the legs and the mobile cylinders, the microrobot can easily move forward in the gastro-intestine. For the feasibility test of the proposed locomotive mechanism, a series of experiments were carried out including in-vitro and in-vivo tests. Based on the experimental results, we conclude that the proposed locomotive mechanism is not only easy to be used for micro capsule endoscopes but also effective to move inside of intestinal tract.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (cat. No.01ch37164)
- No. 10504729,p. 3377-3382
Paddling based Microrobot for Capsule Endoscopes
Recently, the capsule endoscope can be widely used for the diagnosis of digestive organs. It is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. As a solution of these problems, therefore, a locomotive mechanism of capsule endoscopes has being developed. Our proposed capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. By the novel kinematic relation between the legs and the mobile cylinders, the microrobot can easily move forward in the gastro-intestine. For the feasibility test of the proposed locomotive mechanism, a series of experiments were carried out including in-vitro and in-vivo tests. Based on the experimental results, we conclude that the proposed locomotive mechanism is not only easy to be used for micro capsule endoscopes but also effective to move inside of intestinal tract.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 797-800
Cell Migration Driven by a Mechanical Stiffness Gradient
This paper reports the migration of cells along the gradient of mechanical stiffness when the cells are cultured on a flexible substrate with variable rigidity. The thickness difference of PDMS layer was used to create a stiffness gradient between a stiff (7 mum) and a soft (2 mum) region. A fabrication process was developed to minimize the effect of other factors such as height difference and surface chemistry variation that can affect the pattern of cell migration. A cultured embryonic carcinoma cells on the flexible substrate coated with fibronectin, and observed that most of cells were accumulated on the stiffer region. Patterns in various shapes and sizes with stiffness difference were tested to investigate the migratory behavior of the cells. The results suggest that our approach provides a key technology to study the mechanism of cell migration by durotaxis.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 797-800
Cell Migration Driven by a Mechanical Stiffness Gradient
This paper reports the migration of cells along the gradient of mechanical stiffness when the cells are cultured on a flexible substrate with variable rigidity. The thickness difference of PDMS layer was used to create a stiffness gradient between a stiff (7 mum) and a soft (2 mum) region. A fabrication process was developed to minimize the effect of other factors such as height difference and surface chemistry variation that can affect the pattern of cell migration. A cultured embryonic carcinoma cells on the flexible substrate coated with fibronectin, and observed that most of cells were accumulated on the stiffer region. Patterns in various shapes and sizes with stiffness difference were tested to investigate the migratory behavior of the cells. The results suggest that our approach provides a key technology to study the mechanism of cell migration by durotaxis.
- 1 November 2006
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 20 (11) , 1914-1919
Investigation of generative contactile force of frog muscle under electrical stimulation
- 1 November 2006
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 20 (11) , 1914-1919
Investigation of generative contactile force of frog muscle under electrical stimulation
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 470-473
Design and Application of a DEP-based Cell Sorter, for Efficiently Separating Two Types of Human MCF Cells
This paper presents the development of a novel dielectrophoresis (DEP)-activated cell sorter (DACS) that has 3D-asymmeritc microelectrodes. The DACS conventionally utilizes relative strength between the DEP and drag forces. While the conventional cell separators usually depend on different size of cells, the new system differentiates similarly-sized cells by the difference of the electrical properties among cells. It distinguished different types of cells by their differences in electrical properties, conductivity and permittivity. Thus, continuously varying DEP forces generated by the system enabled us to separate MCF10A cells (normal cells derived from human breast epithelium) and MCF7 cells (human breast cancer cells) that have similar sizes. Applying the newly-developed system to separate two different cells, it was possible to separate cancer cells among normal cells.
- 1 October 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 470-473
Design and Application of a DEP-based Cell Sorter, for Efficiently Separating Two Types of Human MCF Cells
This paper presents the development of a novel dielectrophoresis (DEP)-activated cell sorter (DACS) that has 3D-asymmeritc microelectrodes. The DACS conventionally utilizes relative strength between the DEP and drag forces. While the conventional cell separators usually depend on different size of cells, the new system differentiates similarly-sized cells by the difference of the electrical properties among cells. It distinguished different types of cells by their differences in electrical properties, conductivity and permittivity. Thus, continuously varying DEP forces generated by the system enabled us to separate MCF10A cells (normal cells derived from human breast epithelium) and MCF7 cells (human breast cancer cells) that have similar sizes. Applying the newly-developed system to separate two different cells, it was possible to separate cancer cells among normal cells.