Uffe Bernchou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Uffe Bernchou has a total of 224 co-authors. Here are the top co-authors by number of shared publications:
- Carsten Brink
Laboratory of Radiation Physics, Odense University Hospital, Odense, Denmark
44 shared publications - Olfred Hansen
Department of Oncology, Odense University Hospital, Odense, Denmark
25 shared publications - Faisal Mahmood
Department of Clinical Research, University of Southern Denmark, Odense, Denmark; Laboratory of Radiation Physics, Department of Oncology, Odense University Hospital, Odense, Denmark
14 shared publications A. Bertelsen
Laboratory of Radiation Physics, Odense University Hospital, Denmark
13 shared publicationsTine Schytte
11 shared publications- Christian Rønn Hansen
Laboratory of Radiation Physics, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark; Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
10 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 225, 111790
Stereotactic MRI-guided adaptive radiation therapy (SMART) for locally advanced pancreatic cancer: A prospective single-center cohort study
- 1 October 2026
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 225, 111790
Open AccessStereotactic MRI-guided adaptive radiation therapy (SMART) for locally advanced pancreatic cancer: A prospective single-center cohort study
- Open Access
- 15 February 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 37
Balancing dose preservation and treatment efficiency in motion-managed magnetic resonance image-guided radiotherapy of pancreatic cancer
- 15 February 2026
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 37
Open AccessBalancing dose preservation and treatment efficiency in motion-managed magnetic resonance image-guided radiotherapy of pancreatic cancer
- Open Access
- 11 December 2025
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 37, 100368
Optimising acute toxicity monitoring in prostate MR-guided radiotherapy workflow: Results from a prospective study using multiple electronic PRO assessments
- 11 December 2025
- Published by Elsevier in Technical Innovations & Patient Support in Radiation Oncology
- Vol. 37, 100368
Open AccessOptimising acute toxicity monitoring in prostate MR-guided radiotherapy workflow: Results from a prospective study using multiple electronic PRO assessments
- Open Access
- 10 September 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 1185-1193
Feasibility of a reduced gadolinium dose protocol for MRI-guided radiotherapy in glioblastoma
Background and purpose: Magnetic resonance imaging-guided radiotherapy (MRIgRT) enables precise tumour targeting through adaptive planning, which is particularly relevant for glioblastoma due to its dynamic morphology. Gadolinium-based contrast agents (GBCAs) enhance tumour visibility, but frequent use during MRIgRT raises safety concerns related to cumulative gadolinium exposure. This study investigated the feasibility of a reduced GBCA dose protocol for patients with glioblastoma undergoing MRIgRT, aiming to balance tumour conspicuity with minimisation of GBCA-related risks. Patient/material and methods: Nine patients with glioblastoma received hypo-fractionated MRI-Linac radiotherapy (10 × 3.4 Gy) with MRI performed with either full-dose, half-dose or no GBCA enhancement. Online gross tumour volume (GTV) delineation was performed by radiation oncologists, while offline GTV delineation was independently conducted by an expert neuroradiologist on GBCA-enhanced scans. Objective assessment using automatic thresholding and a structured Likert-scale evaluation were also performed. Results: During online adaptation, GTV volumes generally remained stable or increased, whereas offline expert assessments revealed a general volume reduction and systematic volume underestimation with half-dose scans (~18%). Relative delineation volume discrepancies were most pronounced in small tumours. Structured radiologist feedback reported lower confidence, tumour conspicuity and image quality in half-dose scans, particularly for small lesions. Otsu’s thresholding revealed reduced edge definition with decreasing contrast dose. No signs of GBCA retention were observed between fractions. Interpretation: Reduced-dose GBCA-protocols are feasible. Full-dose contrast is recommended at key fractions (e.g. baseline and mid-treatment) and for small tumours, with half-dose imaging reserved for selected intervals or larger tumours. This hybrid approach may balance safety and imaging precision in adaptive MRIgRT.
- 10 September 2025
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 64, 1185-1193
Open AccessFeasibility of a reduced gadolinium dose protocol for MRI-guided radiotherapy in glioblastoma
Background and purpose: Magnetic resonance imaging-guided radiotherapy (MRIgRT) enables precise tumour targeting through adaptive planning, which is particularly relevant for glioblastoma due to its dynamic morphology. Gadolinium-based contrast agents (GBCAs) enhance tumour visibility, but frequent use during MRIgRT raises safety concerns related to cumulative gadolinium exposure. This study investigated the feasibility of a reduced GBCA dose protocol for patients with glioblastoma undergoing MRIgRT, aiming to balance tumour conspicuity with minimisation of GBCA-related risks. Patient/material and methods: Nine patients with glioblastoma received hypo-fractionated MRI-Linac radiotherapy (10 × 3.4 Gy) with MRI performed with either full-dose, half-dose or no GBCA enhancement. Online gross tumour volume (GTV) delineation was performed by radiation oncologists, while offline GTV delineation was independently conducted by an expert neuroradiologist on GBCA-enhanced scans. Objective assessment using automatic thresholding and a structured Likert-scale evaluation were also performed. Results: During online adaptation, GTV volumes generally remained stable or increased, whereas offline expert assessments revealed a general volume reduction and systematic volume underestimation with half-dose scans (~18%). Relative delineation volume discrepancies were most pronounced in small tumours. Structured radiologist feedback reported lower confidence, tumour conspicuity and image quality in half-dose scans, particularly for small lesions. Otsu’s thresholding revealed reduced edge definition with decreasing contrast dose. No signs of GBCA retention were observed between fractions. Interpretation: Reduced-dose GBCA-protocols are feasible. Full-dose contrast is recommended at key fractions (e.g. baseline and mid-treatment) and for small tumours, with half-dose imaging reserved for selected intervals or larger tumours. This hybrid approach may balance safety and imaging precision in adaptive MRIgRT.
- Open Access
- 27 January 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 205, 110748
1-year efficacy results after MR-guided risk-adapted stereotactic radiotherapy of infra-diaphragmatic oligometastases in a multicenter phase II trial
- 27 January 2025
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 205, 110748
Open Access1-year efficacy results after MR-guided risk-adapted stereotactic radiotherapy of infra-diaphragmatic oligometastases in a multicenter phase II trial
- Open Access
- 11 September 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065010
Impact of geometric correction on echo-planar imaging-based apparent diffusion coefficient maps for abdominal radiotherapy
Objective. The apparent diffusion coefficient (ADC) extracted from diffusion-weighted magnetic resonance imaging (DWI) is a potential biomarker in radiotherapy (RT). DWI is often implemented with an echo-planar imaging (EPI) read-out due to speed, but unfortunately low geometric accuracy follows. This study aimed to investigate the influence of geometric distortions on the ADCs extracted from the gross tumor volume (GTV) and on the shape of the GTV in abdominal EPI-DWI. Approach. Twenty-one patients had EPI-DWI scans on a 1.5 T MRI sim before treatment and on a 1.5 T MRI-Linac at one of the first treatment fractions. Off-resonance correction with and without eddy current correction were applied to ADC maps. The clinical GTVs were deformed based on the same (but inverted) corrections to assess the local-regional geometric influence of distortions. Mean surface distance (MSD), Hausdorff distance (HD), and Dice similarity coefficient (DSC) were calculated to compare the original and distorted GTVs, and ADC values were calculated based on a mono-exponential model. Phantom measurements were performed to validate the applied correction method. Main results. The median (range) ADC change within the GTV after full distortion correction was 1.3% (0.02%–6.9%) for MRI-Sim and 1.5% (0.1%–6.4%) for MRI-Linac. The additional effect of the eddy current correction was small in both systems. The median (range) MSD, HD, and DSC comparing the original and off-resonance distorted GTVs for all patients were 0.43 mm (0.11–0.94 mm), 4.00 mm (1.00–7.81 mm) and 0.93 (0.82–0.99), respectively. Significance. Overall effect of distortion correction was small in terms of derived ADC values, indicating that distortion correction is unimportant for prediction of outcomes based on ADC. However, large local geometric changes occurred after off-resonance distortion correction for some patients, suggesting that if the spatial information from ADC maps is to be used for dose painting strategies, corrections should be applied.
- 11 September 2024
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 10 (6) , 065010
Open AccessImpact of geometric correction on echo-planar imaging-based apparent diffusion coefficient maps for abdominal radiotherapy
Objective. The apparent diffusion coefficient (ADC) extracted from diffusion-weighted magnetic resonance imaging (DWI) is a potential biomarker in radiotherapy (RT). DWI is often implemented with an echo-planar imaging (EPI) read-out due to speed, but unfortunately low geometric accuracy follows. This study aimed to investigate the influence of geometric distortions on the ADCs extracted from the gross tumor volume (GTV) and on the shape of the GTV in abdominal EPI-DWI. Approach. Twenty-one patients had EPI-DWI scans on a 1.5 T MRI sim before treatment and on a 1.5 T MRI-Linac at one of the first treatment fractions. Off-resonance correction with and without eddy current correction were applied to ADC maps. The clinical GTVs were deformed based on the same (but inverted) corrections to assess the local-regional geometric influence of distortions. Mean surface distance (MSD), Hausdorff distance (HD), and Dice similarity coefficient (DSC) were calculated to compare the original and distorted GTVs, and ADC values were calculated based on a mono-exponential model. Phantom measurements were performed to validate the applied correction method. Main results. The median (range) ADC change within the GTV after full distortion correction was 1.3% (0.02%–6.9%) for MRI-Sim and 1.5% (0.1%–6.4%) for MRI-Linac. The additional effect of the eddy current correction was small in both systems. The median (range) MSD, HD, and DSC comparing the original and off-resonance distorted GTVs for all patients were 0.43 mm (0.11–0.94 mm), 4.00 mm (1.00–7.81 mm) and 0.93 (0.82–0.99), respectively. Significance. Overall effect of distortion correction was small in terms of derived ADC values, indicating that distortion correction is unimportant for prediction of outcomes based on ADC. However, large local geometric changes occurred after off-resonance distortion correction for some patients, suggesting that if the spatial information from ADC maps is to be used for dose painting strategies, corrections should be applied.
- Open Access
- 28 May 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 197, 110347
Adaptive MRI-guided stereotactic body radiation therapy for locally advanced pancreatic cancer – A phase II study
- 28 May 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 197, 110347
Open AccessAdaptive MRI-guided stereotactic body radiation therapy for locally advanced pancreatic cancer – A phase II study
- Open Access
- 18 May 2024
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 47, 100797
Treatment planning for MR-guided SBRT of pancreatic tumors on a 1.5 T MR-Linac: A global consensus protocol
- 18 May 2024
- Published by Elsevier in Clinical and Translational Radiation Oncology
- Vol. 47, 100797
Open AccessTreatment planning for MR-guided SBRT of pancreatic tumors on a 1.5 T MR-Linac: A global consensus protocol
- Open Access
- 17 May 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 30, 100588
A multi-institutional comparison of retrospective deformable dose accumulation for online adaptive magnetic resonance-guided radiotherapy
- 17 May 2024
- Published by Elsevier in Physics and Imaging in Radiation Oncology
- Vol. 30, 100588
Open AccessA multi-institutional comparison of retrospective deformable dose accumulation for online adaptive magnetic resonance-guided radiotherapy
- 10 October 2023
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 62 (11) , 1551-1560
Geometric distortions in clinical MRI sequences for radiotherapy: insights gained from a multicenter investigation
As magnetic resonance imaging (MRI) becomes increasingly integrated into radiotherapy (RT) for enhanced treatment planning and adaptation, the inherent geometric distortion in acquired MR images pose a potential challenge to treatment accuracy. This study aimed to evaluate the geometric distortion levels in the clinical MRI protocols used across Danish RT centers and discuss influence of specific sequence parameters. Based on the variety in geometric performance across centers, we assess if harmonization of MRI sequences is a relevant measure. Nine centers participated with 12 MRI scanners and MRI-Linacs (MRL). Using a travelling phantom approach, a reference MRI sequence was used to assess variation in baseline distortion level between scanners. The phantom was also scanned with local clinical MRI sequences for brain, head/neck (H/N), abdomen, and pelvis. The influence of echo time, receiver bandwidth, image weighting, and 2D/3D acquisition was investigated. We found a large variation in geometric accuracy across 93 clinical sequences examined, exceeding the baseline variation found between MRI scanners (σ = 0.22 mm), except for abdominal sequences where the variation was lower. Brain and abdominal sequences showed lowest distortion levels ([0.22, 2.26] mm), and a large variation in performance was found for H/N and pelvic sequences ([0.19, 4.07] mm). Post hoc analyses revealed that distortion levels decreased with increasing bandwidth and a less clear increase in distortion levels with increasing echo time. 3D MRI sequences had lower distortion levels than 2D (median of 1.10 and 2.10 mm, respectively), and in DWI sequences, the echo-planar imaging read-out resulted in highest distortion levels. There is a large variation in the geometric distortion levels of clinical MRI sequences across Danish RT centers, and between anatomical sites. The large variation observed makes harmonization of MRI sequences across institutions and adoption of practices from well-performing anatomical sites, a relevant measure within RT.
- 10 October 2023
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 62 (11) , 1551-1560
Geometric distortions in clinical MRI sequences for radiotherapy: insights gained from a multicenter investigation
As magnetic resonance imaging (MRI) becomes increasingly integrated into radiotherapy (RT) for enhanced treatment planning and adaptation, the inherent geometric distortion in acquired MR images pose a potential challenge to treatment accuracy. This study aimed to evaluate the geometric distortion levels in the clinical MRI protocols used across Danish RT centers and discuss influence of specific sequence parameters. Based on the variety in geometric performance across centers, we assess if harmonization of MRI sequences is a relevant measure. Nine centers participated with 12 MRI scanners and MRI-Linacs (MRL). Using a travelling phantom approach, a reference MRI sequence was used to assess variation in baseline distortion level between scanners. The phantom was also scanned with local clinical MRI sequences for brain, head/neck (H/N), abdomen, and pelvis. The influence of echo time, receiver bandwidth, image weighting, and 2D/3D acquisition was investigated. We found a large variation in geometric accuracy across 93 clinical sequences examined, exceeding the baseline variation found between MRI scanners (σ = 0.22 mm), except for abdominal sequences where the variation was lower. Brain and abdominal sequences showed lowest distortion levels ([0.22, 2.26] mm), and a large variation in performance was found for H/N and pelvic sequences ([0.19, 4.07] mm). Post hoc analyses revealed that distortion levels decreased with increasing bandwidth and a less clear increase in distortion levels with increasing echo time. 3D MRI sequences had lower distortion levels than 2D (median of 1.10 and 2.10 mm, respectively), and in DWI sequences, the echo-planar imaging read-out resulted in highest distortion levels. There is a large variation in the geometric distortion levels of clinical MRI sequences across Danish RT centers, and between anatomical sites. The large variation observed makes harmonization of MRI sequences across institutions and adoption of practices from well-performing anatomical sites, a relevant measure within RT.